Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Determinants of Toxicity, Patterns of Failure, and Outcome Among Adult Patients With Soft Tissue Sarcomas of the Extremity and Superficial Trunk Treated With Greater Than Conventional Doses of Perioperative High-Dose-Rate Brachytherapy and External Beam Radiotherapy

Purpose: The present study was undertaken to determine factors predictive of toxicity, patterns of failure, and survival in 60 adult patients with soft tissue sarcomas of the extremity and superficial trunk treated with combined perioperative high-dose-rate brachytherapy and external beam radiotherapy. Methods and Materials: The patients were treated with surgical resection and perioperative high-dose-rate brachytherapy (16 or 24 Gy) for negative and close/microscopically positive resection margins, respectively. External beam radiotherapy (45 Gy) was added postoperatively to reach a 2-Gy equivalent dose of 62.9 and 72.3 Gy, respectively. Adjuvant chemotherapy with ifosfamide and doxorubicin was given to patients with advanced high-grade tumors. Results: Grade 3 toxic events were observed in 18 patients (30%) and Grade 4 events in 6 patients (10%). No Grade 5 events were observed. A location in the lower limb was significant for Grade 3 or greater toxic events on multivariate analysis (p = .013), and the tissue volume encompassed by the 150% isodose line showed a trend toward statistical significance (p = .086). The local control, locoregional control, and distant control rate at 9 years was 77.4%, 69.5%, and 63.8%, respectively. On multivariate analysis, microscopically involved margins correlated with local control (p = .036) and locoregional control (p = .007) and tumor size correlated with distant metastases (p = .004). The 9-year disease-free survival and overall survival rate was 47.0% and 61.5%, respectively. Multivariate analysis showed poorer disease-free survival rates for patients with tumors >6 cm (p = .005) and microscopically involved margins (p = .043), and overall survival rates decreased with increasing tumor size (p = .011). Conclusions: Grade 3 or greater wound complications can probably be decreased using meticulous treatment planning to decrease the tissue volume encompassed by the 150% isodose line, especially in lower limb locations. Microscopically involved margins remain a predictor of local and locoregional failure, despite radiation doses >70 Gy. Patients with tumors {>=}6 cm and microscopically involved margins are at high risk of treatment failure and death from the development of distant metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics and chemistry from parsimonious representations: image analysis via invariant variational autoencoders

Electron, optical, and scanning probe microscopy methods are generating ever increasing volume of image data containing information on atomic and mesoscale structures and functionalities. This necessitates the development of the machine learning methods for discovery of physical and chemical phenomena from the data, such as manifestations of symmetry breaking phenomena in electron and scanning tunneling microscopy images, or variability of the nanoparticles. Variational autoencoders (VAEs) are emerging as a powerful paradigm for the unsupervised data analysis, allowing to disentangle the factors of variability and discover optimal parsimonious representation. Here, we summarize recent developments in VAEs, covering the basic principles and intuition behind the VAEs. The invariant VAEs are introduced as an approach to accommodate scale and translation invariances present in imaging data and separate known factors of variations from the ones to be discovered. We further describe the opportunities enabled by the control over VAE architecture, including conditional, semi-supervised, and joint VAEs. Several case studies of VAE applications for toy models and experimental datasets in Scanning Transmission Electron Microscopy are discussed, emphasizing the deep connection between VAE and basic physical principles. Python codes and datasets discussed in this article are available at https://github.com/saimani5/VAE-tutorials and can be used by researchers as an application guide when applying these to their own datasets.

36 MATERIALS SCIENCE↗

SU-F-T-615: Comparison of Plan Quality for Linac-Based Stereotactic Radiosurgery (SRS) Using Single- and Multi-Isocenter Techniques

Purpose: To compare the plan quality of linear accelerator (linac)-based stereotactic radiosurgery (SRS) using single-isocenter volumetric arc therapy (SI-VMAT), restricted single-isocenter dynamic-arc (RSI-DARC), and multi-isocenter DARC (MI-DARC) techniques. Methods: Fifteen SRS cases were randomly selected and re-planned using the SI-VMAT (Pinnacle), RSI-DARC (iPlanNet) and MI-DARC (iPlanNet). The number of planning target volumes (PTVs) for each plan ranged from 1 to 6. For SI-VMAT, a single isocenter and 3-4 VMAT beams are used for all PTVs, while for MI-DARC, each PTV has its own isocetner with 3 DARC beams. RSI-DARC uses one isocnter with 3-6 DARC beams to irradiate all PTVs within 2.5-cm radius. Both SI-DARC and RSI-DARC plans were optimized manually. The prescription dose was 20 Gy to each PTV. The maximal dose was 25 Gy for RSI-DARC and MI-DARC, but could not be controlled for SI-VMAT due to the nature of VMAT planning. Plan quality indexes including PTV coverage, mean dose of PTV (PTVmean) and tissue (Tmean), V12Gy, conformity index (CI), and V10Gy/VPTV were calculated and compared. Results: Full PTV coverage was achieved for all three techniques. Using the MI-DARC plans as the gold standard, the PTVmean of the SI-VMAT plans was 12.5%±8.3% (mean±standard deviation) higher, in comparison to 0.7%±1.4% for the RSI-DARC plans. Similar trend was observed for other indexes including V12Gy (39.4%±27.3% vs. 9.3%±7.8%), Tmean (35.0%±26.8% vs. 2.8%±3.4%), and V10Gy/VPTV (42.2%±31.5% vs. 9.9%±8.2%). CI is comparable (6.2%±14.2% vs. 6.3%±7.2%). Assuming the treatment time is proportional to the number of isocenters, the reduction of the treatment time in comparison to MI-DARC was 70% for SI-VMAT and 42% for RSI-DARC. Conclusion: Although the SI-VMAT can save a considerable amount of treatment time, the plan indexes also significantly deviates from the gold standard, MI-DARC. RSI-DARC, on the other hand, provides a good compromise between the treatment time and plan quality.

60 APPLIED LIFE SCIENCES↗

Advanced Remedial Methods for Metals and Radionuclides in Vadose Zone Environments

Functionally, the methods for addressing contamination must remove and/or reduce transport or toxicity of contaminants. This problem is particularly challenging in arid environments where the vadose zone can be up to hundreds of feet thick, rendering transitional excavation methods exceedingly costly and ineffective. Delivery of remedial amendments is one of the most challenging and critical aspects for all remedy-based approaches. The conventional approach for delivery is through injection of aqueous remedial solutions. However, heterogeneous vadose zone environments present hydrologic and geochemical challenges that limit the effectiveness. Because the flow of solution infiltration is dominantly controlled by gravity and suction, injected liquid preferentially percolates through highly permeable pathways, bypassing low-permeability zones which frequently contain the majority of the contamination. Moreover, the wetting front can readily mobilize and enhance contaminant transport to underlying aquifers prior to stabilization. Development of innovative, in-situ technologies may be the only way to meet remedial action objectives and long-term stewardship goals. Shear-thinning fluids (i.e., surfactants) can be used to lower the liquid surface tension and create stabile foams, which readily penetrate low permeability zones. Although surfactant foams have been utilized for subsurface mobilization efforts in the oil and gas industry, so far, the concept of using foams as a delivery mechanism for transporting reactive remedial amendments into deep vadose zone environments to stabilize metal and long-lived radionuclide contaminants has not been explored. Foam flow can be directed by pressure gradients rather than being dominated by gravity, and, foam delivery mechanisms limit the volume of water (< 20% vol.) required for remedy delivery and emplacement, thus mitigating contaminant mobilization. We will present the results of an integrated laboratory- / intermediate-scale investigation to simulate, develop, demonstrate, and monitor (using advanced geophysical techniques and natural marker monitoring) foam-based delivery of remedial amendments to stabilize metals and radionuclides in vadose zone environments.

Foam Delivery↗

Design Concepts for an Outage Control Center Information Dashboard

The nuclear industry, and the business world in general, is facing a rapidly increasing amount of data to be dealt with on a daily basis. In the last two decades, the steady improvement of data storage devices and means to create and collect data along the way influenced the manner in which we deal with information. Most data is still stored without filtering and refinement for later use. Many functions at a nuclear power plant generate vast amounts of data, with scheduled and unscheduled outages being a prime example of a source of some of the most complex data sets at the plant. To make matters worse, modern information and communications technology is making it possible to collect and store data faster than our ability to use it for making decisions. However, in most applications, especially outages, raw data has no value in itself; instead, managers, engineers and other specialists want to extract the information contained in it. The complexity and sheer volume of data could lead to information overload, resulting in getting lost in data that may be irrelevant to the task at hand, processed in an inappropriate way, or presented in an ineffective way. To prevent information overload, many data sources are ignored so production opportunities are lost because utilities lack the ability to deal with the enormous data volumes properly. Decision-makers are often confronted with large amounts of disparate, conflicting and dynamic information, which are available from multiple heterogeneous sources. Information and communication technologies alone will not solve this problem. Utilities need effective methods to exploit and use the hidden opportunities and knowledge residing in unexplored data resources. Superior performance before, during and after outages depends upon the right information being available at the right time to the right people. Acquisition of raw data is the easy part; instead, it is the ability to use advanced analytical, data processing and data visualization methods to turn the data into reliable information and comprehensible, actionable information. Techniques like data mining, filtering and analysis only work reliably for well-defined and well-understood problems. The path from data to decision is more complex. The ability to communicate knowledge during outages and emergent issues is crucial. This paper presents an approach to turn the unused data into an opportunity: applying principles from semiotics, human factors and visual analytics to transform the traditional way of processing outage data into media that will improve the collective situation awareness, knowledge, decisions, actions and overall performance of the entire outage team, and also support the reliability, quality and overall effectiveness of maintenance work. The application of the proposed visualization methods will become the medium of a semi-automated analytical process where humans and machines cooperate using their respective, distinct capabilities for the most effective results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Radiotherapy Dose and Volume on Relapse in Merkel Cell Cancer of the Skin

Purpose: To assess the effect of radiotherapy (RT) dose and volume on relapse patterns in patients with Stage I-III Merkel cell carcinoma (MCC). Patients and Methods: This was a retrospective analysis of 112 patients diagnosed with MCC between January 2000 and December 2005 and treated with curative-intent RT. Results: Of the 112 evaluable patients, 88% had RT to the site of primary disease for gross (11%) or subclinical (78%) disease. Eighty-nine percent of patients had RT to the regional lymph nodes; in most cases (71%) this was for subclinical disease in the adjuvant or elective setting, whereas 21 patients (19%) were treated with RT to gross nodal disease. With a median follow-up of 3.7 years, the 2-year and 5-year overall survival rates were 72% and 53%, respectively, and the 2-year locoregional control rate was 75%. The in-field relapse rate was 3% for primary disease, and relapse was significantly lower for patients receiving {>=}50Gy (hazard ratio [HR] = 0.22; 95% confidence interval [CI], 0.06-0.86). Surgical margins did not affect the local relapse rate. The in-field relapse rate was 11% for RT to the nodes, with dose being significant for nodal gross disease (HR = 0.24; 95% CI, 0.07-0.87). Patients who did not receive elective nodal RT had a much higher rate of nodal relapse compared with those who did (HR = 6.03; 95% CI, 1.34-27.10). Conclusion: This study indicates a dose-response for subclinical and gross MCC. Doses of {>=}50Gy for subclinical disease and {>=}55Gy for gross disease should be considered. The draining nodal basin should be treated in all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer Tumors Greater Than 5 cm: Safety and Efficacy

Purpose: The purpose of this study was to determine outcomes of patients with node-negative medically inoperable non-small cell lung cancer (NSCLC) whose primary tumors exceeded 5 cm and were treated with stereotactic body radiation therapy (SBRT). Methods and Materials: We surveyed our institutional prospective lung SBRT registry to identify treated patients with tumors >5 cm. Treatment outcomes for local control (LC), locoregional control (LRC), disease-free survival (DFS), and overall survival (OS) were assessed by Kaplan-Meier estimates. Toxicities were graded according to Common Terminology Criteria for Adverse Events version 4. Mean pretreatment pulmonary function test values were compared to mean posttreatment values. Results: From December 2003 to July 2014, 40 patients met study criteria. Median follow-up was 10.8 months (range: 0.4-70.3 months). Median age was 76 years (range: 56-90 years), median body mass index was 24.3 (range: 17.7-37.2), median Karnofsky performance score was 80 (range: 60-90), and median Charlson comorbidity index score was 2 (range: 0-5). Median forced expiratory volume in 1 second (FEV1) was 1.41 L (range: 0.47-3.67 L), and median diffusion capacity (DLCO) was 47% of predicted (range: 29%-80%). All patients were staged by fluorodeoxyglucose-positron emission tomography/computed tomography staging, and 47.5% underwent mediastinal staging by endobronchial ultrasonography. Median tumor size was 5.6 cm (range: 5.1-10 cm), median SBRT dose was 50 Gy (range: 30-60 Gy) in 5 fractions (range: 3-10 fractions). Eighteen-month LC, LRC, DFS, and OS rates were 91.2%, 64.4%, 34.6%, and 59.7%, respectively. Distant failure was the predominant pattern of failure (32.5%). Three patients (7.5%) experienced grade 3 or higher toxicity. Mean posttreatment FEV1 was not significantly reduced (P=.51), but a statistically significant absolute 6.5% (P=.03) reduction in DLCO was observed. Conclusions: Lung SBRT for medically inoperable node-negative NSCLC with primary tumors larger than 5 cm is safe and provides excellent local control with limited toxicity. The predominant pattern of failure in this population was distant failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Study of Pseudoprogression After Spine Stereotactic Body Radiation Therapy

Purpose: To determine the incidence of pseudoprogression (PP) after spine stereotactic body radiation therapy based on a detailed and quantitative assessment of magnetic resonance imaging (MRI) morphologic tumor alterations, and to identify predictive factors distinguishing PP from local recurrence (LR). Methods and Materials: A retrospective analysis of 35 patients with 49 spinal segments treated with spine stereotactic body radiation therapy, from 2009 to 2014, was conducted. The median number of follow-up MRI studies was 4 (range, 2-7). The gross tumor volumes (GTVs) within each of the 49 spinal segments were contoured on the pretreatment and each subsequent follow-up T1- and T2-weighted MRI sagittal sequence. T2 signal intensity was reported as the mean intensity of voxels constituting each volume. LR was defined as persistent GTV enlargement on ≥2 serial MRI studies for ≥6 months or on pathologic confirmation. PP was defined as a GTV enlargement followed by stability or regression on subsequent imaging within 6 months. Kaplan-Meier analysis was used for estimation of actuarial local control, disease-free survival, and overall survival. Results: The median follow-up was 23 months (range, 1-39 months). PP was identified in 18% of treated segments (9 of 49) and LR in 29% (14 of 49). Earlier volume enlargement (5 months for PP vs 15 months for LR, P=.005), greater GTV to reference nonirradiated vertebral body T2 intensity ratio (+30% for PP vs −10% for LR, P=.005), and growth confined to 80% of the prescription isodose line (80% IDL) (8 of 9 PP cases vs 1 of 14 LR cases, P=.002) were associated with PP on univariate analysis. Multivariate analysis confirmed an earlier time to volume enlargement and growth within the 80% IDL as significant predictors of PP. LR involved the epidural space in all but 1 lesion, whereas PP was confined to the vertebral body in 7 of 9 cases. Conclusions: PP was observed in 18% of treated spinal segments. Tumor growth confined to the 80% IDL and earlier time to tumor enlargement were predictive for PP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-9A-02: BEST IN PHYSICS (THERAPY) - 4D IMRT Planning Using Highly- Parallelizable Particle Swarm Optimization

Purpose: We present a particle swarm optimization (PSO)-based 4D IMRT planning technique designed for dynamic MLC tracking delivery to lung tumors. The key idea is to utilize the temporal dimension as an additional degree of freedom rather than a constraint in order to achieve improved sparing of organs at risk (OARs). Methods: The target and normal structures were manually contoured on each of the ten phases of a 4DCT scan acquired from a lung SBRT patient who exhibited 1.5cm tumor motion despite the use of abdominal compression. Corresponding ten IMRT plans were generated using the Eclipse treatment planning system. These plans served as initial guess solutions for the PSO algorithm. Fluence weights were optimized over the entire solution space i.e., 10 phases × 12 beams × 166 control points. The size of the solution space motivated our choice of PSO, which is a highly parallelizable stochastic global optimization technique that is well-suited for such large problems. A summed fluence map was created using an in-house B-spline deformable image registration. Each plan was compared with a corresponding, internal target volume (ITV)-based IMRT plan. Results: The PSO 4D IMRT plan yielded comparable PTV coverage and significantly higher dose—sparing for parallel and serial OARs compared to the ITV-based plan. The dose-sparing achieved via PSO-4DIMRT was: lung Dmean = 28%; lung V20 = 90%; spinal cord Dmax = 23%; esophagus Dmax = 31%; heart Dmax = 51%; heart Dmean = 64%. Conclusion: Truly 4D IMRT that uses the temporal dimension as an additional degree of freedom can achieve significant dose sparing of serial and parallel OARs. Given the large solution space, PSO represents an attractive, parallelizable tool to achieve globally optimal solutions for such problems. This work was supported through funding from the National Institutes of Health and Varian Medical Systems. Amit Sawant has research funding from Varian Medical Systems, VisionRT Ltd. and Elekta.

60 APPLIED LIFE SCIENCES↗

Multiscale Modeling of Nanoparticle Precipitation in Oxide Dispersion-Strengthened Steels Produced by Laser Powder Bed Fusion

Laser Powder Bed Fusion (LPBF) enables the efficient production of near-net-shape oxide dispersion-strengthened (ODS) alloys, which possess superior mechanical properties due to oxide nanoparticles (e.g., yttrium oxide, Y-O, and yttrium-titanium oxide, Y-Ti-O) embedded in the alloy matrix. To better understand the precipitation mechanisms of the oxide nanoparticles and predict their size distribution under LPBF conditions, we developed an innovative physics-based multiscale modeling strategy that incorporates multiple computational approaches. These include a finite volume method model (Flow3D) to analyze the temperature field and cooling rate of the melt pool during the LPBF process, a density functional theory model to calculate the binding energy of Y-O particles and the temperature-dependent diffusivities of Y and O in molten 316L stainless steel (SS), and a cluster dynamics model to evaluate the kinetic evolution and size distribution of Y-O nanoparticles in as-fabricated 316L SS ODS alloys. The model-predicted particle sizes exhibit good agreement with experimental measurements across various LPBF process parameters, i.e., laser power (110–220 W) and scanning speed (150–900 mm/s), demonstrating the reliability and predictive power of the modeling approach. The multiscale approach can be used to guide the future design of experimental process parameters to control oxide nanoparticle characteristics in LPBF-manufactured ODS alloys. Additionally, our approach introduces a novel strategy for understanding and modeling the thermodynamics and kinetics of precipitation in high-temperature systems, particularly molten alloys.

Wang, Zhengming (ORCID:0000000241627112)↗

Motion Interplay as a Function of Patient Parameters and Spot Size in Spot Scanning Proton Therapy for Lung Cancer

Purpose: To quantify the impact of respiratory motion on the treatment of lung tumors with spot scanning proton therapy. Methods and Materials: Four-dimensional Monte Carlo simulations were used to assess the interplay effect, which results from relative motion of the tumor and the proton beam, on the dose distribution in the patient. Ten patients with varying tumor sizes (2.6-82.3 cc) and motion amplitudes (3-30 mm) were included in the study. We investigated the impact of the spot size, which varies between proton facilities, and studied single fractions and conventionally fractionated treatments. The following metrics were used in the analysis: minimum/maximum/mean dose, target dose homogeneity, and 2-year local control rate (2y-LC). Results: Respiratory motion reduces the target dose homogeneity, with the largest effects observed for the highest motion amplitudes. Smaller spot sizes (σ ≈ 3 mm) are inherently more sensitive to motion, decreasing target dose homogeneity on average by a factor 2.8 compared with a larger spot size (σ ≈ 13 mm). Using a smaller spot size to treat a tumor with 30-mm motion amplitude reduces the minimum dose to 44.7% of the prescribed dose, decreasing modeled 2y-LC from 87.0% to 2.7%, assuming a single fraction. Conventional fractionation partly mitigates this reduction, yielding a 2y-LC of 71.6%. For the large spot size, conventional fractionation increases target dose homogeneity and prevents a deterioration of 2y-LC for all patients. No correlation with tumor volume is observed. The effect on the normal lung dose distribution is minimal: observed changes in mean lung dose and lung V{sub 20} are <0.6 Gy(RBE) and <1.7%, respectively. Conclusions: For the patients in this study, 2y-LC could be preserved in the presence of interplay using a large spot size and conventional fractionation. For treatments using smaller spot sizes and/or in the delivery of single fractions, interplay effects can lead to significant deterioration of the dose distribution and lower 2y-LC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of cold walls on PET image quantification and volume segmentation: A phantom study

Purpose: Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These “cold” walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in errors in the estimation of standardized uptake values. Numerous papers suggest that this is an issue for phantom work simulating tumor tissue, quality control, and calibration work. This study aims to investigate the influence of the cold plastic wall thickness on the quantification of 18F-fluorodeoxyglucose on the image activity recovery and on the performance of advanced automatic segmentation algorithms for the delineation of active regions delimited by plastic walls.Methods: A commercial set of six spheres of different diameters was replicated using a manufacturing technique which achieves a reduction in plastic walls thickness of up to 90%, while keeping the same internal volume. Both sets of thin- and thick-wall inserts were imaged simultaneously in a custom phantom for six different tumor-to-background ratios. Intensity values were compared in terms of mean and maximum standardized uptake values (SUVs) in the spheres and mean SUV of the hottest 1 ml region (SUV{sub max}, SUV{sub mean}, and SUV{sub peak}). The recovery coefficient (RC) was also derived for each sphere. The results were compared against the values predicted by a theoretical model of the PET-intensity profiles for the same tumor-to-background ratios (TBRs), sphere sizes, and wall thicknesses. In addition, ten automatic segmentation methods, written in house, were applied to both thin- and thick-wall inserts. The contours obtained were compared to computed tomography derived gold standard (“ground truth”), using five different accuracy metrics.Results: The authors' results showed that thin-wall inserts achieved significantly higher SUV{sub mean}, SUV{sub max}, and RC values (up to 25%, 16%, and 25% higher, respectively) compared to thick-wall inserts, which was in agreement with the theory. This effect decreased with increasing sphere size and TBR, and resulted in substantial (>5%) differences between thin- and thick-wall inserts for spheres up to 30 mm diameter and TBR up to 4. Thinner plastic walls were also shown to significantly improve the delineation accuracy for the majority of the segmentation methods tested, by increasing the proportion of lesion voxels detected, although the errors in image quantification remained non-negligible.Conclusions: This study quantified the significant effect of a 90% reduction in the thickness of insert walls on SUV quantification and PET-based boundary detection. Mean SUVs inside the inserts and recovery coefficients were particularly affected by the presence of thick cold walls, as predicted by a theoretical approach. The accuracy of some delineation algorithms was also significantly improved by the introduction of thin wall inserts instead of thick wall inserts. This study demonstrates the risk of errors deriving from the use of cold wall inserts to assess and compare the performance of PET segmentation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pain and Mean Absorbed Dose to the Pubic Bone After Radiotherapy Among Gynecological Cancer Survivors

Purpose: To analyze the relationship between mean absorbed dose to the pubic bone after pelvic radiotherapy for gynecological cancer and occurrence of pubic bone pain among long-term survivors. Methods and Materials: In an unselected, population-based study, we identified 823 long-term gynecological cancer survivors treated with pelvic radiotherapy during 1991-2003. For comparison, we used a non-radiation-treated control population of 478 matched women from the Swedish Population Register. Pain, intensity of pain, and functional impairment due to pain in the pubic bone were assessed with a study-specific postal questionnaire. Results: We analyzed data from 650 survivors (participation rate 79%) with median follow-up of 6.3 years (range, 2.3-15.0 years) along with 344 control women (participation rate, 72 %). Ten percent of the survivors were treated with radiotherapy; ninety percent with surgery plus radiotherapy. Brachytherapy was added in 81%. Complete treatment records were recovered for 538/650 survivors, with dose distribution data including dose-volume histograms over the pubic bone. Pubic bone pain was reported by 73 survivors (11%); 59/517 (11%) had been exposed to mean absorbed external beam doses <52.5 Gy to the pubic bone and 5/12 (42%) to mean absorbed external beam doses {>=}52.5 Gy. Thirty-three survivors reported pain affecting sleep, a 13-fold increased prevalence compared with control women. Forty-nine survivors reported functional impairment measured as pain walking indoors, a 10-fold increased prevalence. Conclusions: Mean absorbed external beam dose above 52.5 Gy to the pubic bone increases the occurrence of pain in the pubic bone and may affect daily life of long-term survivors treated with radiotherapy for gynecological cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancement of microwave to optical spin-based quantum transduction via a magnon mode

We propose a method for converting single microwave photons to single optical sideband photons based on spinful impurities in magnetic materials. This hybrid system is advantageous over previous proposals because (i) the implementation allows much higher transduction rates (10 3 times faster at the same optical pump Rabi frequency) than state-of-the-art devices, (ii) high-efficiency transduction is found to happen in a significantly larger space of device parameters (in particular, over 1 GHz microwave detuning), and (iii) it does not require mode volume matching between optical and microwave resonators. We identify the needed magnetic interactions as well as potential materials systems to enable this speed up using erbium dopants for telecom compatibility. This is an important step towards realizing high-fidelity entangling operations between remote qubits and will provide additional control of the transduction through perturbation of the magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inventory and Characterization of Categories 3-5 Disused Sealed Radioactive Sources - 19284

Brazil has one of the biggest inventories of SRS in the world, not only because of the large industrial park, the well-developed health care infrastructure and the numerous mining operations, but also by the use of radioactive sources in consumer products, such as smoke detectors, lightning arresters, surge protectors and even cardiac pacemakers. Presently, the inventory of DSRS at the WML is of more than 10,000; if the sources from lightning arresters, smoke detectors and Ir-192 with activities above the clearance levels are included, the estimate is over 150,000. The Waste Management Laboratory (WML) of the Nuclear and Energy Research Institute (IPEN/CNEN-SP) is responsible for the management and treatment of these sources. An important aspect to consider is that Brazil does not have a defined strategy or a protocol for screening and inventorying these sources, whose management was limited only to storage. The WML started the development of methods and operational work, to characterize and reduce the total volume of this inventory for the borehole-type final disposal facility yet to be constructed, where the DSRS will be disposed of. The information available from these sources is in a database created in 1980, when the sources began to be received. Several records on the FRSD that were checked are incomplete or simply incorrect, since there is no correspondence between the dates of entry of these sources in the storage and their physical characteristics. Some reasons can be listed to try to understand the divergences: the inspection when receiving the sources was not possible, no inspection procedure was defined, there were technical difficulties to open the packages. The objective of this work is to organize the inventory in a standardized way, control access, traceability, reduction of the necessary time to locate and characterize the sources upon reception, and of the repetitive work in the operational routine, and finally release of space in the storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Automated Treatment Planning Process to Select Breast Cancer Patients for Active Breathing Control to Achieve Cardiac Dose Reduction

Purpose: To evaluate a rapid automated treatment planning process for the selection of patients with left-sided breast cancer for a moderate deep inspiration breath-hold (mDIBH) technique using active breathing control (ABC); and to determine the dose reduction to the left anterior descending coronary artery (LAD) and the heart using mDIBH. Method and Materials: Treatment plans were generated using an automated method for patients undergoing left-sided breast radiotherapy (n = 53) with two-field tangential intensity-modulated radiotherapy. All patients with unfavorable cardiac anatomy, defined as having >10 cm{sup 3} of the heart receiving 50% of the prescribed dose (V{sub 50}) on the free-breathing automated treatment plan, underwent repeat scanning on a protocol using a mDIBH technique and ABC. The doses to the LAD and heart were compared between the free-breathing and mDIBH plans. Results: The automated planning process required approximately 9 min to generate a breast intensity-modulated radiotherapy plan. Using the dose-volume criteria, 20 of the 53 patients were selected for ABC. Significant differences were found between the free-breathing and mDIBH plans for the heart V{sub 50} (29.9 vs. 3.7 cm{sup 3}), mean heart dose (317 vs. 132 cGy), mean LAD dose (2,047 vs. 594 cGy), and maximal dose to 0.2 cm{sup 3} of the LAD (4,155 vs. 1,507 cGy, all p <.001). Of the 17 patients who had a breath-hold threshold of {>=}0.8 L, 14 achieved a {>=}90% reduction in the heart V{sub 50} using the mDIBH technique. The 3 patients who had had a breath-hold threshold <0.8 L achieved a lower, but still significant, reduction in the heart V{sub 50}. Conclusions: A rapid automated treatment planning process can be used to select patients who will benefit most from mDIBH. For selected patients with unfavorable cardiac anatomy, the mDIBH technique using ABC can significantly reduce the dose to the LAD and heart, potentially reducing the cardiac risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Special fractal growth of dendrite copper using a hydrothermal method

Special fractal dendrite Cu nanostructures have been synthesized through a simple hydrothermal method, and the effects of the volume ratio between glycerol and water and the concentration of H{sub 3}PO{sub 3} on the morphologies of dendrite Cu have been studied in detail. The Field emission scanning electron microscopy (FESEM), Transmission electron microscopy (TEM) and X-ray diffraction (XRD) have been used to characterize these Cu products. The results indicate that rhombic diamond and different morphologies of fractal dendrite were prepared because of the accumulation of Cu nuclei based on the diffusion-limited aggregation (DLA) and the nucleation-limited aggregation (NLA) model. Fortunately, symmetrical leaf-like dendrite Cu nanostructures different from Cu dendrites reported before have been obtained. Additionally, an explanation for the growth of fractal dendrite Cu has been discussed carefully. - Graphical abstract: Uniform dendritic Cu are grown through controlling V{sub glycerol/water} in range of 0.6-1.2 and the concentration of H{sub 3}PO{sub 3} in range of 0.06-0.3 M. The rhombic cluster Cu are obtained by decreasing the amount of glycerol. Highlights: > Volume ratio of glycerol/water and concentration of H{sub 3}PO{sub 3} were varied, respectively. > Morphologies of dendritic Cu have some changes. > Leaf-like and rhombic cluster Cu were obtained. > The concentration changes affect the aggregation of Cu crystallites. > The aggregation and crystallographic orientation cause leaf-like Cu nanostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗