A Compact Delayed Photocurrent Model Based on a Reduced Order Data-Driven Exponential Time Integrator.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Preliminary: This final report corresponds to a grant (DE-SC0021216) that was awarded to the University of Montana. Mid-way through the grant period, I relocated from the University of Montana to the University of Arizona. The grant was ended at University of Montana in late 2022, with all efforts concluding on 08/26/22; the remaining funds supporting the project were relinquished by University of Montana, and were later awarded to University of Arizona under a new grant, with start date 04/01/23. This report focuses on results of research efforts at UMontana through 08/26/22. Results: We made progress in each of the three aims of the proposal. We released software that identifies and fills gaps in the annotation of metabolic proteins within bacterial genomes. We made substantial progress in developing software for alignment-based annotation of protein coding DNA, allowing for coding frameshifts caused by sequencing error. Finally, we made notable progress in developing AI methods (specifically: a neural embedding model) for identifying similarities between protein sequences based on amino-wise latent vectors. These efforts were supplemented by development of methods for protein modeling in support of predicting protein-drug binding activity, and by my leadership of a team in the NIH/DOE 2021 Petabyte-Scale Sequence Search hack-a-thon.
We fulfilled all original three aims of the proposal. Following the earlier release (during the first phase of the project at Montana) of software that identifies and fills gaps in the annotation of metabolic proteins within bacterial genomes, we have nearly completed a second gap-filling tool that improves accuracy and explainability. We completed software for alignment-based annotation of protein coding DNA, allowing for coding frameshifts caused by sequencing error. Finally, we completed a neural embedding model for identifying similarities between protein sequences based on amino-wise latent vectors.
Data from both laboratory studies and atmospheric measurements are used to develop an empirical parameterization for the immersion freezing activity of natural mineral dust particles. Measurements made with the Colorado State University (CSU) continuous flow diffusion chamber (CFDC) when processing mineral dust aerosols at a nominal 105% relative humidity with respect to water (RH w ) are taken as a measure of the immersion freezing nucleation activity of particles. Ice active frozen fractions vs. temperature for dusts representative of Saharan and Asian desert sources were consistent with similar measurements in atmospheric dust plumes for a limited set of comparisons available. The parameterization developed follows the form of one suggested previously for atmospheric particles of non-specific composition in quantifying ice nucleating particle concentrations as functions of temperature and the total number concentration of particles larger than 0.5 μm diameter. Such an approach does not explicitly account for surface area and time dependencies for ice nucleation, but sufficiently encapsulates the activation properties for potential use in regional and global modeling simulations, and possible application in developing remote sensing retrievals for ice nucleating particles. A calibration factor is introduced to account for the apparent underestimate (by approximately 3, on average) of the immersion freezing fraction of mineral dust particles for CSU CFDC data processed at an RH w of 105% vs. maximum fractions active at higher RH w . Instrumental factors that affect activation behavior vs. RH w in CFDC instruments remain to be fully explored in future studies. Nevertheless, the use of this calibration factor is supported by comparison to ice activation data obtained for the same aerosols from Aerosol Interactions and Dynamics of the Atmosphere (AIDA) expansion chamber cloud parcel experiments. Further comparison of the new parameterization, including calibration correction, to predictions of the immersion freezing surface active site density parameterization for mineral dust particles, developed separately from AIDA experimental data alone, shows excellent agreement for data collected in a descent through a Saharan aerosol layer. These studies support the utility of laboratory measurements to obtain atmospherically relevant data on the ice nucleation properties of dust and other particle types, and suggest the suitability of considering all mineral dust as a single type of ice nucleating particle as a useful first-order approximation in numerical modeling investigations.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
This study implemented a data-intensive supervised machine learning approach, through a quasi-experimental framework, with the objective of quantifying the impact of oil and gas operator-specific proprietary data on ML-based predictive model performance as compared to using oil and gas datasets that are publicly available.
Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness
Management of environmental issues can require integration of multiple types of data and information, conducting data analysis and interpretation, and providing data visualization for effective communications. These data elements are important for site management to support regulator interactions and provide defensibility for remedial decisions. Databases and information repositories are core elements of managing data; however, efficient data access and analysis also enable effective site management. The U.S. Department of Energy (DOE) Hanford Site is an example of a complex site with a voluminous quantity of environmental data and a need for efficient site management. Different tiers of data and information tools have been developed and deployed to address site needs. These tools are configured for ready access via the web site interfaces and meet the rigorous quality requirements for environmental site management. Evolving efforts are focused on an integrated platform to meet site environmental management needs. In this platform, users can access site information at multiple levels of detail based on their need and permissions, so that data and associated analyses are presented within the context of the site mission and the user's management or technical needs. This concept is not only applicable at individual sites like Hanford but also applicable at other sites within the DOE complex. An integrated web-based architecture that links data visualization, data analytics, and management tools can provide holistic access to large data sets, minimize complexity, and maximize interactivity and technical communication. (authors)
A downhole multi-modality inspection system includes a first imaging device operable to generate first imaging data and a second imaging device operable to generate second imaging data. The first imaging device includes a first source operable to emit energy of a first modality, and a first detector operable to detect returning energy induced by the emitted energy of the first modality. The second imaging device includes a second source operable to emit energy of a second modality, and a second detector operable to detect returning energy induced by the emitted energy of the second modality. The system further includes a processor configured to receive the first imaging data and the second imaging data, and integrate the first imaging data with the second imaging data into an enhanced data stream. The processor correlates the first imaging data and the second imaging data to provide enhanced data for detecting potential wellbore anomalies.
Understanding how solvent properties influence the solution-to-film assembly of conjugated polymers remains a critical challenge due to the complex and intertwined nature of polymer–solvent interactions. In this study, we integrate a data-driven framework with experimental validation to identify key parameters influencing the assembly and performance of poly[2,5-(2-octyldodecyl)-3,6-diketopyrrolopyrrole-alt-5,5-(2,5-di(thien-2-yl)thieno[3,2-b]thiophene)] (DPP-DTT) in organic field-effect transistors (OFETs). A machine learning (ML) approach identified the normalized Reichardt polarity parameter (E T N ) as a significant descriptor correlated with DPP-DTT hole mobility (μ). Systematic DPP-DTT devices fabricated using solvents across a wide E T N range revealed that higher E T N solvents yield enhanced μ. To elucidate the structural origins of high μ, we conducted comprehensive analyses using UV–vis–NIR spectroscopy and grazing incidence wide angle X-ray scattering (GIWAXS) measurements. The results revealed that films processed from high E T N solvents exhibit reduced paracrystallinity. By analyzing the solution-state behavior using optical microscopy and solution WAXS, we revealed polymer solubility differences in the various solvents and associated distinct polymer assembly pathways, elucidating why the high E T N solvent produces long-range ordered films. Notably, the high E T N solvent shows a pronounced preference for liquid-crystal (LC)-mediated assembly, providing a mechanistic explanation for the enhanced structural order. Therefore, these results demonstrate that solvent polarity, as evaluated by E T N , serves as an important parameter that plays a significant role in the DPP-DTT assembly pathway and resultant solid-state morphology. This work provides a strategy for integrating data science with experiments to identify critical parameters associated with complex polymer systems and helps guide rational process design for high-performance organic electronics.
A consistent picture of dynamic channeling, invasion, spreading, and breakthrough (CISB) of supercritical CO 2 in the hierarchical fluvial reservoir at Cranfield, Mississippi is presented after 10 years of integration and analysis of complementary field monitoring and characterization data. The dynamic CISB with small-scale CO 2 -flow channels in the F1-F2-F3 cross section (F1, F2, and F3 are one injection and two monitoring wells) was imaged by daily electrical resistance tomography (ERT) and time-lapse crosswell seismic surveys. One, three, and four CO 2 flow channels logged at F1, F2, and F3, respectively, were dynamically connected with strong temporal variations in CO 2 saturation during 221 days of drainage with injection rate doubling twice and 81 days of imbibition. Three intermediate-scale CO 2 flow channels (with highest CO 2 saturation) normal to the cross section were ERT-imaged during late-time drainage. A large-scale, sinuous fluvial CO 2 flow channel was imaged by repeat surface seismic survey at the end of the imbibition. The fluvial sandstone channel sinuously bypasses the F1-F2-F3 cross section in a point bar, but the channel is connected to the cross section through an intermediate-scale sandstone channel, forming a complicated flow channel network. The multiscale flow channel network (in the fluvial channel-point bar system) revealed from the observed CISB enables us to consistently interpret the hydrological monitoring data of three tracer tests, each conducted during an injection rate step, and preinjection hydraulic-thermal-tracer tests. Finally, this interpretation of the CISB and flow channel network can guide future modeling and data inversion to best understand the effects of natural heterogeneity on CO 2 storage efficiency and residual trapping.
The Jack Rabbit Pretest (PT) 2021E PT3 was fired on March 12, 2008 at the Contained Firing Facility, Site 300, Lawrence Livermore National Laboratory. This experiment is part of an effort to determine the properties of LX-17 in a regime where corner-turning behavior and dead-zone formation are not well understood. Photonic Doppler Velocimetry (PDV) measured diagnostic plate velocities confirming the presence of a persistent LX-17 dead-zone formation and the resultant impulse gradient applied under the diagnostic plate. The Jack Rabbit Pretest 2021E PT3, 120 millimeter diameter experiment returned data on all eight PDV probes. The probes measured on the central axis and at 10, 20, 25, 30, 35, 40, 50 millimeters from the central axis. The experiment was shot at an ambient room temperature of 65 degrees Fahrenheit. The earliest PDV signal extinction was 41.7 microseconds at 30 millimeters. The latest PDV signal extinction time was 65.0 microseconds at 10 millimeters. The measured velocity ranged from meters per second to thousands of meters per second. First detonation wave induced jump-off was measured at 40 millimeters at 10.9 microseconds. The PDV data provided an unambiguous indication of dead-zone formation and an impulse gradient applied to the diagnostic plate. The central axis had a last measured velocity of 1636 meters per second. At 40 millimeters the last measured velocity was 2056 meters per second. The low-to-high velocity ratio was 0.80. Velocity data was integrated to compute diagnostic plate cross section profiles. Velocity data was differentiated to compute a peak pressure under the diagnostic plate at the central axis of 64.6 kilobars at 15.7 microseconds. Substantial motion (>1 m/s) of the diagnostic plate over the dead-zone is followed by detonation region motion within approximately 2.2 microseconds.
The Jack Rabbit Pretest (PT) 2021E PT4 was fired on March 19, 2008 at the Contained Firing Facility, Site 300, Lawrence Livermore National Laboratory. This experiment is part of an effort to determine the properties of LX-17 in a regime where corner-turning behavior and dead-zone formation are not well understood. Photonic Doppler Velocimetry (PDV) measured diagnostic plate velocities confirming the presence of a persistent LX-17 dead-zone formation and the resultant impulse gradient applied under the diagnostic plate. The Jack Rabbit Pretest 2021E PT4, 120 millimeter diameter experiment returned data on all eight PDV probes. The probes measured on the central axis and at 10, 20, 25, 30, 35, 40, 50 millimeters from the central axis. The experiment was shot at an ambient room temperature of 64 degrees Fahrenheit. The earliest PDV signal extinction was 44.9 microseconds at 30 millimeters. The latest PDV signal extinction time was 69.5 microseconds at 10 millimeters. The measured velocity ranged from meters per second to thousands of meters per second. First detonation wave induced jump-off was measured at 50 millimeters at 13.3 microseconds. The PDV data provided an unambiguous indication of dead-zone formation and an impulse gradient applied to the diagnostic plate. The central axis had a last measured velocity of 1558 meters per second. At 40 millimeters the last measured velocity was 2019 meters per second. The low-to-high velocity ratio was 0.77. Velocity data was integrated to compute diagnostic plate cross section profiles. Velocity data was differentiated to compute a peak pressure under the diagnostic plate at the central axis of 98.6 kilobars at 15.0 microseconds. Substantial motion (>1 m/s) of the diagnostic plate over the dead-zone is followed by detonation region motion within approximately 0.7 microseconds.
The Jack Rabbit Pretest (PT) 2021E PT5 was fired on March 17, 2008 at the Contained Firing Facility, Site 300, Lawrence Livermore National Laboratory. This experiment is part of an effort to determine the properties of LX-17 in a regime where corner-turning behavior and dead-zone formation are not well understood. Photonic Doppler Velocimetry (PDV) measured diagnostic plate velocities confirming the presence of a persistent LX-17 dead-zone formation and the resultant impulse gradient applied under the diagnostic plate. The Jack Rabbit Pretest 2021E PT5, 160 millimeter diameter experiment returned data on all eight PDV probes. The probes measured on the central axis and at 20, 30, 35, 45, 55, 65, 75 millimeters from the central axis. The experiment was shot at an ambient room temperature of 65 degrees Fahrenheit. The earliest PDV signal extinction was 40.0 microseconds at 45 millimeters. The latest PDV signal extinction time was 64.9 microseconds at 20 millimeters. The measured velocity ranged from meters per second to thousands of meters per second. First detonation wave induced jump-off was measured at 55 millimeters at 12.8 microseconds. The PDV data provided an unambiguous indication of dead-zone formation and an impulse gradient applied to the diagnostic plate. The central axis had a last measured velocity of 1877 meters per second. At 65 millimeters the last measured velocity was 2277 meters per second. The low-to-high velocity ratio was 0.82. Velocity data was integrated to compute diagnostic plate cross section profiles. Velocity data was differentiated to compute a peak pressure under the diagnostic plate at the central axis of 78 kilobars at 11.9 and 21.2 microseconds. Substantial motion (>1 m/s) of the diagnostic plate over the dead-zone is followed by detonation region motion within approximately 4.1 microseconds.