Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

SU-E-I-32: Benchmarking Head CT Doses: A Pooled Vs. Protocol Specific Analysis of Radiation Doses in Adult Head CT Examinations

Purpose: The aim of this study was to collect CT dose index data from adult head exams to establish benchmarks based on either: (a) values pooled from all head exams or (b) values for specific protocols. One part of this was to investigate differences in scan frequency and CT dose index data for inpatients versus outpatients. Methods: We collected CT dose index data (CTDIvol) from adult head CT examinations performed at our medical facilities from Jan 1st to Dec 31th, 2014. Four of these scanners were used for inpatients, the other five were used for outpatients. All scanners used Tube Current Modulation. We used X-ray dose management software to mine dose index data and evaluate CTDIvol for 15807 inpatients and 4263 outpatients undergoing Routine Brain, Sinus, Facial/Mandible, Temporal Bone, CTA Brain and CTA Brain-Neck protocols, and combined across all protocols. Results: For inpatients, Routine Brain series represented 84% of total scans performed. For outpatients, Sinus scans represented the largest fraction (36%). The CTDIvol (mean ± SD) across all head protocols was 39 ± 30 mGy (min-max: 3.3–540 mGy). The CTDIvol for Routine Brain was 51 ± 6.2 mGy (min-max: 36–84 mGy). The values for Sinus were 24 ± 3.2 mGy (min-max: 13–44 mGy) and for Facial/Mandible were 22 ± 4.3 mGy (min-max: 14–46 mGy). The mean CTDIvol for inpatients and outpatients was similar across protocols with one exception (CTA Brain-Neck). Conclusion: There is substantial dose variation when results from all protocols are pooled together; this is primarily a function of the differences in technical factors of the protocols themselves. When protocols are analyzed separately, there is much less variability. While analyzing pooled data affords some utility, reviewing protocols segregated by clinical indication provides greater opportunity for optimization and establishing useful benchmarks.

60 APPLIED LIFE SCIENCES↗

Sonic IR crack detection of aircraft turbine engine blades with multi-frequency ultrasound excitations

Effectively and accurately detecting cracks or defects in critical engine components, such as turbine engine blades, is very important for aircraft safety. Sonic Infrared (IR) Imaging is such a technology with great potential for these applications. This technology combines ultrasound excitation and IR imaging to identify cracks and flaws in targets. In general, failure of engine components, such as blades, begins with tiny cracks. Since the attenuation of the ultrasound wave propagation in turbine engine blades is small, the efficiency of crack detection in turbine engine blades can be quite high. The authors at Wayne State University have been developing the technology as a reliable tool for the future field use in aircraft engines and engine parts. One part of the development is to use finite element modeling to assist our understanding of effects of different parameters on crack heating while experimentally hard to achieve. The development has been focused with single frequency ultrasound excitation and some results have been presented in a previous conference. We are currently working on multi-frequency excitation models. The study will provide results and insights of the efficiency of different frequency excitation sources to foster the development of the technology for crack detection in aircraft engine components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the sign of the population difference in a two-level system by frequency-modulation spectroscopy

Population inversions can occur in two-level systems as a result of chemical kinetic processes that involve pulsed excitation of a system with a large amount of excess energy, for example, multi-photon dissociation. In this work, we report the use of frequency-modulation (FM) spectroscopy to determine, from the phase of the FM signal, the sign of the population difference in a two-level system – specifically, whether the two-level system is inverted. Here, as a proof of principle demonstration of this technique, we show that FM signals from an inverted I 2 B 3 Π 0+u – X 1 $Σ$ $^+$$_g$ transition, prepared by a pulsed laser, have opposite phase with respect to signals from a non-inverted system, the Rb D 1 -line absorption transition.

74 ATOMIC AND MOLECULAR PHYSICS↗

Glove Perforations During Interventional Radiological Procedures

Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preparation, Electrical and Magnetic Properties of Poly(m-phenylenediamine)/ZnFe{sub 2}O{sub 4} Nanocomposites

The different ratios of ZnFe{sub 2}O{sub 4} nanoparticles (10 and 20%) were wrapped on poly(m-phenylenediamine) through in situ oxidative polymerization method. The formation of PmPD/ZnFe{sub 2}O{sub 4} nanocomposites was confirmed through FTIR spectroscopy and XRD pattern. From the XRD results, the average crystalline size of ZnFe{sub 2}O{sub 4} nanoparticles and PmPD/ZnFe{sub 2}O{sub 4} nanocomposites were also calculated. The SEM image of ZnFe{sub 2}O{sub 4} nanoparticles shows granular morphology and FESEM images of PmPD/ZnFe{sub 2}O{sub 4} nanocomposites indicate the ZnFe{sub 2}O{sub 4} nanoparticles are agglomerated on PmPD matrix. The soft magnetic behavior of ZnFe{sub 2}O{sub 4} nanoparticles and PmPD/ZnFe{sub 2}O{sub 4} nanocomposites were observed from vibrating sample magnetometer. The dielectric properties of PmPD/ZnFe{sub 2}O{sub 4} nanocomposites were studied with different temperatures and frequencies. The magnetic properties of ZnFe{sub 2}O{sub 4} nanoparticles were also analyzed through Mössbauer spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evolutions of the Micro- and Macrostructure and Tensile Property of Cu-15Ni-8Sn Alloy During Electromagnetic Stirring-Assisted Horizontal Continuous Casting

The present study investigates the evolution of the micro- and macrostructure and tensile property of the Cu-15Ni-8Sn (weight percent) alloy prepared by horizontal continuous casting and electromagnetic stirring (EMS). The results show that the application of EMS is beneficial for grain refinement and for microstructure transformation from the dendrite to the rosette structure and that it leads to a significant improvement in the tensile property. The forced flow induced by EMS homogenizes the temperature field ahead of the solid-liquid interface, disturbing the heat flow direction and resulting in the columnar to equiaxed transition. The grain refinement under different electromagnetic stirring frequencies is mainly derived from the homogenization of the temperature and the remelting of dendritic arms. In addition, the evolution of the tensile property with and without EMS is discussed from the perspective of fracture mode and fine-grain strengthening.

36 MATERIALS SCIENCE↗

Effect of Bcl11b genotypes and {gamma}-radiation on the development of mouse thymic lymphomas

Bcl11b is a haploinsufficient tumor suppressor gene and expressed in many tissues such as thymus, brain and skin. Irradiated Bcl11b{sup +/-} heterozygous mice mostly develop thymic lymphomas, but the preference of Bcl11b inactivation for thymic lymphomas remains to be addressed. We produced Bcl11b{sup +/-} heterozygous and Bcl11b wild-type mice of p53{sup +/-} background and compared their incidence of {gamma}-ray induced thymic lymphomas. Majority of the tumors in p53{sup +/-} mice were skin tumors, and only 5 (36%) of the 14 tumors were thymic lymphomas. In contrast, Bcl11b{sup +/-}p53{sup +/-} doubly heterozygous mice developed thymic lymphomas at the frequency of 27 (79%) of the 34 tumors developed (P = 0.008). This indicates the preference of Bcl11b impairment for thymic lymphoma development. We also analyzed loss of the wild-type alleles in the 27 lymphomas, a predicted consequence given by {gamma}-irradiation. However, the loss frequency was low, only six (22%) for Bcl11b and five (19%) for p53. The frequencies did not differ from those of spontaneously developed thymic lymphomas in the doubly heterozygous mice, though the latency of lymphoma development markedly differed between them. This suggests that the main contribution of irradiation at least in those mice is not for the tumor initiation by inducing allelic losses but probably for the promotion of thymic lymphoma development.

60 APPLIED LIFE SCIENCES↗

Evaluation of Image-Guidance Strategies in the Treatment of Localized Prostate Cancer

Purpose: To compare different image-guidance strategies in the alignment of prostate cancer patients. Using data from patients treated using daily image guidance, the remaining setup errors for several different strategies were retrospectively calculated. Methods and Materials: The alignment data from 74 patients treated with helical tomotherapy were analyzed, resulting in a data set of 2,252 fractions during which a megavoltage computed tomography image was used for image guidance with intraprostatic metallic fiducials. Given the daily positional adjustments, a variety of protocols, differing in imaging frequency and method, were retrospectively studied. The residual setup errors were determined for each protocol. Results: As expected, the systematic errors were effectively reduced with imaging. However, the random errors were unaffected. Even when image guidance was performed every other day with a running mean of the previous displacements, residual setup errors >5 mm occurred in 24% of all fractions. This frequency increased to about 40% if setup errors >3 mm were scored. Conclusion: Setup errors increased with decreasing frequency of image guidance. However, residual errors were still significant at the 5-mm level, even with imaging was performed every other day. This suggests that localizations must be performed daily in the set up of prostate cancer patients during a course of external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ASCENDE-RT: An Analysis of Treatment-Related Morbidity for a Randomized Trial Comparing a Low-Dose-Rate Brachytherapy Boost with a Dose-Escalated External Beam Boost for High- and Intermediate-Risk Prostate Cancer

Purpose: To report the genitourinary (GU) and gastrointestinal (GI) morbidity and erectile dysfunction in a randomized trial comparing 2 methods of dose escalation for high- and intermediate-risk prostate cancer. Methods and Materials: ASCENDE-RT (Androgen Suppression Combined with Elective Nodal and Dose Escalated Radiation Therapy) enrolled 398 men, median age 68 years, who were then randomized to either a standard arm that included 12 months of androgen deprivation therapy and pelvic irradiation to 46 Gy followed by a dose-escalated external beam radiation therapy (DE-EBRT) boost to 78 Gy, or an experimental arm that substituted a low-dose-rate prostate brachytherapy (LDR-PB) boost. At clinic visits, investigators recorded GU and GI morbidity and information on urinary continence, catheter use, and erectile function. Exclusion of 15 who received nonprotocol treatment and correction of 14 crossover events left 195 men who actually received a DE-EBRT boost and 188, an LDR-PB boost. Median follow-up was 6.5 years. Results: The LDR-PB boost increased the risk of needing temporary catheterization and/or requiring incontinence pads. At 5 years the cumulative incidence of grade 3 GU events was 18.4% for LDR-PB, versus 5.2% for DE-EBRT (P<.001). Compared with the cumulative incidence, the 5-year prevalence of grade 3 GU morbidity was substantially lower for both arms (8.6% vs 2.2%, P=.058). The 5-year cumulative incidence of grade 3 GI events was 8.1% for LDR-PB, versus 3.2% for DE-EBRT (P=.124). The 5-year prevalence of grade 3 GI toxicity was lower than the cumulative incidence for both arms (1.0% vs 2.2%, respectively). Among men reporting adequate baseline erections, 45% of LDR-PB patients reported similar erectile function at 5 years, versus 37% after DE-EBRT (P=.30). Conclusions: The incidence of acute and late GU morbidity was higher after LDR-PB boost, and there was a nonsignificant trend for worse GI morbidity. No differences in the frequency of erectile dysfunction were observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physical properties of zircon and scheelite lutetium orthovanadate: Experiment and first-principles calculation

Pure zircon and scheelite LuVO{sub 4} were prepared by solid state reaction and high-pressure route, respectively. Structure, elastic constants, lattice dynamics and thermodynamics of LuVO{sub 4} polymorphs were studied by experiments and first principles calculation. Calculations here are in good agreement with the experimental results. The phonon dispersions of LuVO{sub 4} polymorphs were studied by the linear response method. The calculated phonon dispersions show that zircon and scheelite LuVO{sub 4} phases are dynamically stable. Raman-active frequencies were measured and assigned to different modes according to the calculations. The internal frequencies shift downward after phase transition from zircon to scheelite. Born effective charge tensors elements for both phases are analyzed. The finite temperature thermodynamic properties of LuVO{sub 4} polymorphs were calculated from the obtained phonon density of states by quasi-harmonic approach. - Graphical abstract: Lutetium orthovanadate polymorphs were synthesized by SSR and HP methods and their physical and chemical properties, including lattice dynamical properties, were determined by DFT calculations and experiments. Display Omitted - Highlights: • Pure zircon and scheelite LuVO{sub 4} polymorphs were synthesized by solid state reaction and high-pressure route. • Chemical and physical properties of LuVO4 polymorphs were studied by experiments and first principles calculation. • Raman-active frequencies were measured and assigned to different modes according to the calculations. • Lattice dynamics of polymorphs were discussed in details.

36 MATERIALS SCIENCE↗

Modulation of microstructure and optical properties of Mo-doped ZnO thin films by substrate temperature

Highlights: • Mo-doped ZnO films are obtained by sputtering at various substrate temperatures. • High-quality MZO thin films with good crystalline have been obtained at 200 °C. • Deposition temperature affects the amount of defects in the crystalline structure - Abstract: Mo-doped ZnO(MZO) films were deposited on Si (1 1 1) substrates by radio frequency sputtering at different substrate temperatures of 200, 300 and 400 °C. The effect of the substrate temperature on the structural and optical properties of the MZO films has been investigated. X-ray diffraction results reveal that all the films are polycrystalline with a hexagonal wurtzite structure with a preferential orientation according to the direction (0 0 2) plane. The crystallinity and surface morphologies of the films are strongly dependent on the growth temperature, which in turn exerts a great effect on microstructural and optical properties of the MZO films. The optical absorption measurements show high ultraviolet (UV) absorbance property of MZO with sharp and intense absorption band in this region and the optical band gap (E{sub g}) are 3.18, 3.22, 3.25 and 3.21 eV for the films deposited at room temperature, 200, 300 and 400 °C. The photoluminescence (PL) intensity of a strong broad violet–blue emission from MZO nanostructures with increasing deposited temperature was also observed. X-ray photoelectron spectroscopy (XPS) was employed to investigate the surface chemical composition of growth products.

36 MATERIALS SCIENCE↗

Effect of Backbone Chemistry on the Structure of Polyurea Films Deposited by Molecular Layer Deposition

An experimental investigation into the growth of polyurea films by molecular layer deposition was performed by examining trends in the growth rate, crystallinity, and orientation of chains as a function of backbone flexibility. Growth curves obtained for films containing backbones of aliphatic and phenyl groups indicate that an increase in backbone flexibility leads to a reduction in growth rate from 4 to 1 Å/cycle. Crystallinity measurements collected using grazing incidence X-ray diffraction and Fourier transform infrared spectroscopy suggest that some chains form paracrystalline, out-of-plane stacks of polymer segments with packing distances ranging from 4.4 to 3.7 Å depending on the monomer size. Diffraction intensity is largely a function of the homogeneity of the backbone. Near-edge X-ray absorption fine structure measurements for thin and thick samples show an average chain orientation of ~25° relative to the substrate across all samples, suggesting that changes in growth rate are not caused by differences in chain angle but instead may be caused by differences in the frequency of chain terminations. In conclusion, these results suggest a model of molecular layer deposition-based chain growth in which films consist of a mixture of upward growing chains and horizontally aligned layers of paracrystalline polymer segments.

36 MATERIALS SCIENCE↗

Multipoint Observations of Quasiperiodic Emission Intensification and Effects on Energetic Electron Precipitation

The two Van Allen Probes simultaneously recorded a coherently modulated quasiperiodic (QP) emission that persisted for 3 h. The magnetic field pulsation at the locations of the two satellites showed a substantial difference, and their frequencies were close to but did not exactly match the repetition frequency of QP emissions for most of the time, suggesting that those coherent QP emissions probably originated from a common source, which then propagated over a broad area in the magnetosphere. The QP emissions were amplified by local anisotropic electron distributions, and their large-scale amplitudes were modulated by the plasma density. A novel observation of this event is that chorus waves at frequencies above QP emissions exhibit a strong correlation with QP emissions. Those chorus waves intensified when the QP emissions reach their peak frequency. This indicates that embryonic QP emissions may be critical for its own intensification as well as chorus waves under certain circumstances. A Low-Earth-Orbit POES satellite observed enhanced energetic electron precipitation in conjunction with the Van Allen Probes, providing direct evidence that QP emissions precipitate energetic electrons into the atmosphere. Finally, this scenario is quantitatively confirmed by our quasilinear diffusion simulation results.

79 ASTRONOMY AND ASTROPHYSICS↗

High-energy electron emission from metallic nano-tips driven by intense single-cycle terahertz pulses

Electrons ejected from atoms and subsequently driven to high energies in strong laser fields enable techniques from attosecond pulse generation to imaging with rescattered electrons. Analogous processes govern strong-field electron emission from nanostructures, where long wavelength radiation and large local field enhancements hold the promise for producing electrons with substantially higher energies, allowing for higher resolution time-resolved imaging. Here we report on the use of single-cycle terahertz pulses to drive electron emission from unbiased nano-tips. Energies exceeding 5 keV are observed, substantially greater than previously attained at higher drive frequencies. Despite large differences in the magnitude of the respective local fields, we find that the maximum electron energies are only weakly dependent on the tip radius, for 10 nm<R<1,000 nm. As a result, due to the single-cycle nature of the field, the high-energy electron emission is predicted to be confined to a single burst, potentially enabling a variety of applications.

36 MATERIALS SCIENCE↗

Aerosol jet printing of surface acoustic wave microfluidic devices

Abstract The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Role of Assay Type in Determining Free 25-Hydroxyvitamin D Levels in Diverse Populations

Serum 25-hydroxyvitamin D (25OHD) is the most frequently used marker of vitamin D status. Low 25OHD is associated with bone loss, fractures {Cauley, 2010 #1516;Ensrud, 2009 #1517}, and other adverse health outcomes {Theodoratou, 2014 #1518}. Most extra renal tissues only have access to free 25OHD, and free 25OHD concentration is thus a plausible biomarker of 25OHD availability and function {Johnsen, 2014 #1443;Chun, 2014 #1343}. Stronger associations with free or bioavailable 25OHD than with total 25OHD were reported for serum calcium, parathyroid hormone (PTH) {Bhan, 2012 #1124} and bone mineral density (BMD) {Powe, 2011 #1129}. These findings have led to the suggestion that free or bioavailable 25OHD may provide a more clinically relevant measure of tissue 25OHD availability and vitamin D status {Powe, 2013 #1369; Holick NEJM 2013 editorial}. The US Preventive Services Task Force (LeFevre 2015) recently pointed to the gap in research regarding bioavailable and free 25OHD and noted the possibility that these may be better markers of tissue 25OHD availability. Free 25OHD is conventionally calculated from the concentrations of total 25OHD, vitamin D binding protein (DBP) and albumin, with or without a factor accounting for DBP genotype-specific binding affinities {Bouillon, 1981 #1207;Chun, 2012 #1143; Powe, 2011 #1129;Johnsen, 2014 #1443}. DBP—or Group specific component (GC) {Hirschfeld, 1959 #1468}—polymorphisms (rs4588 and rs7041) give rise to three major polymorphic isoforms of DBP, GC-1F, GC-1S and GC-2, the frequencies of which differ globally, with GC-1F alleles more common in populations of African descent {Kambou, 1986 #1122}. Although DBP is a primary component of free and bioavailable 25OHD calculations, substantial variation in DBP between assays has been noted (Powe suggest to cite here previous publications as in previous version of this Ms). Using DBP measured by a monoclonal antibody Powe et al. {Powe, 2013 #1369} concluded that calculated free 25OHD in African-Americans was equal or higher than in US whites, questioning the implications of low total 25OHD concentrations in African Americans (Holick 2013). This idea gained widespread attention in medical and lay press {LeFevre, 2015 #1598; Bhan, 2014 #1485; Durazo-Arvizu, 2014 #1519}, and many others) and may have important implications for nutrional supplementation policy. To better understand the importance of free 25OHD estimates, and its racial differences, we conducted studies in cohorts based in the US, UK and The Gambia that included participants of African and European ancestry known to differ in GC genotype distribution. We characterized the molecular forms of circulating DBP through comparison of several DBP assays and DBP peptide proteomic analysis, to obtain both calculated and directly measured free 25OHD by geographical region, race and GC genotype.

Environmental Molecular Sciences Laboratory↗

Dynamics of excitation of backward waves in long inhomogeneous systems

The spatio-temporal dynamics of excitation of a long backward-wave oscillator with a profiled resonant parameter is studied in detail. It is shown that the transition to multifrequency regimes of the rf generation occurs due to splitting the long oscillator into several shorter single-frequency oscillators with different eigenfrequencies. This fact can be useful, in particular, for an explanation of the dynamics of the intense cyclotron radiation, which is detected escaping from Earth in the kilometric wavelength range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITER ICRF Antenna Reduced-Scale Mock-up EM Simulations and Comparisons with the Measurements

A reduced-scale mock-up of one ITER ICRF antenna triplet has been recently built, featuring the optimized front-end geometry, an optimized 4-port junction and the implementation of a service stub. Provision is made to adapt the frequency response of the antenna by acting on the 4-port junction arms lengths, the service stub length as well as the position of its inclusion in the circuit. Variable antenna loading is achieved by moving a salted water tank in front of the antenna. A summary of the first measurements carried out on this mockup is reported in a companion paper. The EM simulations of the mock-up are done with CST Microwave Studio registered. The geometry of the mock-up is converted from a CAD file and all essential details are included in the model. S parameters of the mock-up are calculated in a large frequency range covering the ITER ICRF antenna frequency band for different geometries of the mock-up and distances to the load. Results of the simulations and systematic comparisons with the measurements are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗