Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A Direction-Sensitive Detector for Electron Antineutrinos

A modular design is proposed for an electron antineutrino detector based on boron-doped liquid scintillator. Tests have been carried out on small detector systems using neutrons to simulate the antineutrino detection signature. Results from these tests are reported, and the possibility of using a larger system of similar design to detect reactor antineutrinos is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-17A-09: Direct Visualization and Monitoring of Medical Radiation Beams in Air

Purpose: Radiation therapy errors are rare but potentially catastrophic. Recent fatal incidents could have been avoided by utilizing real-time methods of monitoring delivery of radiation during treatment. However, few existing methods are practical enough to be used routinely. The study presents the first experimental demonstration of a novel non-perturbing method of monitoring radiation therapy through the phenomena of air scintillation. Methods: Monitoring of radiation delivery was devised by leveraging the phenomena of nitrogen excitation in air by ionizing radiation. The excitation induced weak luminescence in the 300–400 nm range, a process called air scintillation. An electron-multiplication charge-coupled device camera (f/0.95 lens; 440 nm shortpass) was set-up in a clinical treatment vault and was used to capture air scintillation images of kilovoltage and megavoltage beams. Monte Carlo simulations were performed to determine the correlation of radiation dose to air scintillation. Results: Megavoltage beams from a Varian Clinac 21EX and kilovoltage beams from an orthovoltage unit (50 kVp, 30 mA) were visualized with a relatively short exposure time (10 s). Cherenkov luminescence produced in a plastic transparent phantom did not interfere with detection of air scintillation. The image intensity displayed an inverse intensity falloff (r{sup 2} = 0.89) along the central axis and was proportional to dose rate (r{sup 2} = 0.9998). As beam energy increased, the divergence of the imaged beam decreased. Last, air scintillation was visualized during a simulated total skin irradiation electron treatment. Conclusion: Air scintillation can be clinically detected to monitor a radiation beam in an inexpensive and non-perturbing manner. This new method is advantageous in monitoring for gross delivery and uniquely capable of wide area in a single acquisition, such as the case for online verification of total body / skin / lymphoid irradiation treatments.

60 APPLIED LIFE SCIENCES↗

SENSITIVITY OF STACKED IMAGING DETECTORS TO HARD X-RAY POLARIZATION

The development of multi-layer optics which allow to focus photons up to 100 keV and more promises an enormous jump in sensitivity in the hard X-ray energy band. This technology is already planned to be exploited by future missions dedicated to spectroscopy and imaging at energies >10 keV, e.g., Astro-H and NuSTAR. Nevertheless, our understanding of the hard X-ray sky would greatly benefit from carrying out contemporaneous polarimetric measurements, because the study of hard spectral tails and of polarized emission are often two complementary diagnostics of the same non-thermal and acceleration processes. At energies above a few tens of keV, the preferred technique to detect polarization involves the determination of photon directions after a Compton scattering. Many authors have asserted that stacked detectors with imaging capabilities can be exploited for this purpose. If it is possible to discriminate those events which initially interact in the first detector by Compton scattering and are subsequently absorbed by the second layer, then the direction of scattering is singled out from the hit pixels in the two detectors. In this paper, we give the first detailed discussion of the sensitivity of such a generic design to the X-ray polarization. The efficiency and the modulation factor are calculated analytically from the geometry of the instruments and then compared with the performance as derived by means of Geant4 Monte Carlo simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer

The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adaptive Bayesian Inference for Prediction

Performing rigorous predictive simulation necessitates that all available data be incorporated into the modeling process in order to accurately quantify uncertainties in predictions of the model. Statistical Bayesian inference is the most commonly used approach for incorporating data into uncertainty estimates. Statistical Bayesian inference uses data and an assumed error model to inform posterior distributions of model input variables and model discrepancies. An explicit characterization of the posterior distribution is not formed, but rather methods such as Markov chain Monte-Carlo (MCMC) are used to draw samples from the posterior. These samples are then used to evaluate statistics, such as integrals, of predicted quantities of interest (QoI). Recently the authors have developed an alternative reformulation of Bayesian inference based upon a measure-theoretic inversion technique. Unlike traditional statistical Bayesian inference, this reformulation allows us to directly interrogate the posterior distribution and, consequently, to generate samples from the posterior without MCMC. In this work we use forward propagation uncertainty quantification techniques to reduce the cost of approximating the posterior distribution. Specifically we investigate goal-oriented adaptive sparse grid approximation methods. These adaptive methods concentrate high-fidelity model evaluations in regions of the parameter space that both significantly contribute to the uncertainty in specified QoI and are informed by the available data. Numerical results are presented to compare our approach with the standard statistical Bayesian approach and to demonstrate the effectiveness of the goal-oriented adaptivity.

97 MATHEMATICS AND COMPUTING↗

Effect of surface roughness and size of beam on squeeze-film damping—Molecular dynamics simulation study

We use large-scale molecular dynamics (MD) to characterize fluid damping between a substrate and an approaching beam. We focus on the near contact regime where squeeze film (where fluid gap is comparable to the mean free path of the gas molecules) and many-body effects in the fluid become dominant. The MD simulations provide explicit description of many-body and non-equilibrium processes in the fluid as well as the surface topography. We study how surface roughness and beam width increases the damping coefficient due to their effect on fluid mobility. We find that the explicit simulations are in good agreement with prior direct simulation Monte Carlo results except at near-contact conditions where many-body effects in the compressed fluid lead the increased damping and weaker dependence on beam width. We also show that velocity distributions near the beam edges and for short gaps deviate from the Boltzmann distribution indicating a degree of local non-equilibrium. These results will be useful to parameterize compact models used for microsystem device-level simulations and provide insight into mesoscale simulations of near-contact damping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MagAO IMAGING OF LONG-PERIOD OBJECTS (MILO). II. A PUZZLING WHITE DWARF AROUND THE SUN-LIKE STAR HD 11112

HD 11112 is an old, Sun-like star that has a long-term radial velocity (RV) trend indicative of a massive companion on a wide orbit. Here we present direct images of the source responsible for the trend using the Magellan Adaptive Optics system. We detect the object (HD 11112B) at a separation of 2.″2 (100 au) at multiple wavelengths spanning 0.6–4 μ m and show that it is most likely a gravitationally bound cool white dwarf. Modeling its spectral energy distribution suggests that its mass is 0.9–1.1 M {sub ⊙}, which corresponds to very high eccentricity, near edge-on orbits from a Markov chain Monte Carlo analysis of the RV and imaging data together. The total age of the white dwarf is >2 σ , which is discrepant with that of the primary star under most assumptions. The problem can be resolved if the white dwarf progenitor was initially a double white dwarf binary that then merged into the observed high-mass white dwarf. HD 11112B is a unique and intriguing benchmark object that can be used to calibrate atmospheric and evolutionary models of cool white dwarfs and should thus continue to be monitored by RV and direct imaging over the coming years.

79 ASTRONOMY AND ASTROPHYSICS↗

Semi-Analytical Benchmarks for MCNP6

Code verification is an extremely important process that involves proving or disproving the validity of code algorithms by comparing them against analytical results of the underlying physics or mathematical theory on which the code is based. Monte Carlo codes such as MCNP6 must undergo verification and testing upon every release to ensure that the codes are properly simulating nature. Specifically, MCNP6 has multiple sets of problems with known analytic solutions that are used for code verification. Monte Carlo codes primarily specify either current boundary sources or a volumetric fixed source, either of which can be very complicated functions of space, energy, direction and time. Thus, most of the challenges with modeling analytic benchmark problems in Monte Carlo codes come from identifying the correct source definition to properly simulate the correct boundary conditions. The problems included in this suite all deal with mono-energetic neutron transport without energy loss, in a homogeneous material. The variables that differ between the problems are source type (isotropic/beam), medium dimensionality (infinite/semi-infinite), etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model validation for inferred hot-spot conditions in National Ignition Facility experiments

Progress toward ignition requires accurately diagnosing current conditions and assessing proximity metrics for implosion experiments on the National Ignition Facility. Hot-spot conditions are not directly measured, but rather inferred, often using simple 0- and 1D models [P. Patel et al., Phys. Plasmas 27, 050901 (2020)]. In this work, we present a detailed accuracy validation exercise using a set of ~20,000 2D simulations encompassing a variety of performance and degradation levels. We find good agreement between the model-inferred pressure and the simulated burn-weighted pressure at peak neutron production and also present results on the precision of inferred quantities using a Markov-Chain Monte Carlo algorithm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the beam chamber vacuum system of K = 500 cyclotron at Variable Energy Cyclotron Centre Kolkata

The beam chamber of Variable Energy Cyclotron Centre, Kolkata's K = 500 superconducting cyclotron is pumped by liquid helium cooled cryopanel with liquid nitrogen cooled radiation shield. Performance of the vacuum system was evaluated by cooling the cryopanel assembly with liquid nitrogen and liquid helium. Direct measurement of beam chamber pressure is quite difficult because of space restrictions and the presence of high magnetic field. Pressure gauges were placed away from the beam chamber. The beam chamber pressure was evaluated using a Monte Carlo simulation software for vacuum system and compared with measurements. The details of the vacuum system, measurements, and estimation of pressure of the beam chamber are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxygen vacancy ordering within anion-deficient Ceria

The structural properties of anion deficient ceria, CeO{sub 2-{delta}}, have been studied as a function of oxygen partial pressure, p(O{sub 2}), over the range 0>=log{sub 10p}(O{sub 2})>=-18.9 at 1273(2) K using the neutron powder diffraction technique. Rietveld refinement of the diffraction data collected on decreasing p(O{sub 2}) showed increases in the cubic lattice parameter, a, the oxygen nonstoichiometry, delta, and the isotropic thermal vibration parameters, u{sub Ce} and u{sub O}, starting at log{sub 10p}(O{sub 2}){approx}-11. The increases are continuous, but show a distinct kink at log{sub 10p}(O{sub 2}){approx}-14.5. Analysis of the total scattering (Bragg plus diffuse components) using reverse Monte Carlo (RMC) modelling indicates that the O{sup 2-} vacancies preferentially align as pairs in the <111> cubic directions as the degree of nonstoichiometry increases. This behaviour is discussed with reference to the chemical crystallography of the CeO{sub 2}-Ce{sub 2}O{sub 3} system at ambient temperature and, in particular, to the nature of the long-range ordering of O{sup 2-} vacancies within the crystal structure of Ce{sub 7}O{sub 12}. - Graphical abstract: Partial radial distribution function for oxygen vacancies within CeO{sub 1.710} at 1273 K (solid line) showing the increased tendency for local ordering in <111> directions compared to a random distribution (dashed line).

36 MATERIALS SCIENCE↗

Flaw Tolerance of Octet Truss Lattices with Random Flaws

We investigate the behavior of octet truss lattices in which some proportion of the bars are randomly removed from a perfect lattice. Using a lattice specimen of 9 × 9 × 9 octet truss unit cells as the nominal design, we simulate the response of prefect and flawed lattices with a finite element method implementation of rod theory. For each of two simple load cases, we perform a Monte Carlo analysis where we consider many instantiations of flawed lattices where between 1% and 20% of the bars are missing, and compare the axial loads in the remaining bars to those in the perfect lattice. We also compare the overall stiffness of the flawed lattices to the perfect lattice. Our results show progressive deterioration of lattice strength and stiffness with increasing proportion of missing bars, as expected, with the location and magnitude of the highest-loaded (most failure-prone) bars depending more on the load case and bar orientation than on the location and connectivity of missing bars. As such, the results reported herein may not be directly transferable to different lattice geometries.

36 MATERIALS SCIENCE↗

HUBBLE SPACE TELESCOPE PROPER MOTION (HSTPROMO) CATALOGS OF GALACTIC GLOBULAR CLUSTERS. I. SAMPLE SELECTION, DATA REDUCTION, AND NGC 7078 RESULTS

We present the first study of high-precision internal proper motions (PMs) in a large sample of globular clusters, based on Hubble Space Telescope (HST) data obtained over the past decade with the ACS/WFC, ACS/HRC, and WFC3/UVIS instruments. We determine PMs for over 1.3 million stars in the central regions of 22 clusters, with a median number of ∼60,000 stars per cluster. These PMs have the potential to significantly advance our understanding of the internal kinematics of globular clusters by extending past line-of-sight (LOS) velocity measurements to two- or three-dimensional velocities, lower stellar masses, and larger sample sizes. We describe the reduction pipeline that we developed to derive homogeneous PMs from the very heterogeneous archival data. We demonstrate the quality of the measurements through extensive Monte Carlo simulations. We also discuss the PM errors introduced by various systematic effects and the techniques that we have developed to correct or remove them to the extent possible. We provide in electronic form the catalog for NGC 7078 (M 15), which consists of 77,837 stars in the central 2.'4. We validate the catalog by comparison with existing PM measurements and LOS velocities and use it to study the dependence of the velocity dispersion on radius, stellar magnitude (or mass) along the main sequence, and direction in the plane of the sky (radial or tangential). Subsequent papers in this series will explore a range of applications in globular-cluster science and will also present the PM catalogs for the other sample clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved modeling of β electronic recoils in liquid xenon using LUX calibration data

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $\beta$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0, while also providing the final electronic recoil model and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

Super‐Droplet Method to Simulate Lagrangian Microphysics of Nuclear Fallout in a Homogeneous Cloud

Abstract Nuclear detonations produce hazardous local and global particles or fallout. Predicting fallout size, chemical components, and location is necessary to inform officials and determine immediate guidance for the public. However, existing nuclear detonation fallout models prescribe the particle size distributions based on limited observations. In this work, we apply the super‐droplet method, which is a numerical modeling technique developed for cloud microphysics, to simulate size distributions of particles in a mushroom cloud formed post‐detonation of a nuclear device. We model fallout formation and evolution with homogeneous nucleation and condensation of a single species and a Monte Carlo coagulation algorithm. We verify the numerical methods representing coagulation and condensation processes against analytical test problems. Additionally, we explore several scenarios for the integral system mass and yield in equivalent kilotons (kt) of TNT (trinitrotoluene). The fallout size distribution median diameter d pg follows a scaling law based on the integral system mass m v 0 kg and yield Y kt: nm. We test the effect of cloud turbulence, enhanced nucleation and growth, and vapor volatility with a sensitivity study. The range in median diameter predictions for simulations of historical tests performed over the Pacific encompass the measurements of particles sampled from the cloud caps. Predicted median particle size ranges up to 217, 123, 86, and 35 nm for historical tests with yields of 0.2, 0.7, 2, and 10 Mt, respectively. This work can be expanded in many different directions to build a more predictive model for fallout formation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Kinetic Monte Carlo model for material aging: Simulations of second phase formation at Au/Bi{sub 2}Te{sub 3} junction in oxygen environments

Electronic properties of semiconductor devices are sensitive to defects such as second phase precipitates, grain sizes, and voids. These defects can evolve over time especially under oxidation environments and it is therefore important to understand the resulting aging behavior in order for the reliable applications of devices. In this paper, we propose a kinetic Monte Carlo framework capable of simultaneous simulation of the evolution of second phases, precipitates, grain sizes, and voids in complicated systems involving many species including oxygen. This kinetic Monte Carlo model calculates the energy barriers of various events based directly on the experimental data. As a first step of our model implementation, we incorporate the second phase formation module in the parallel kinetic Monte Carlo codes SPPARKS. Selected aging simulations are performed to examine the formation of second phase precipitates at the eletroplated Au/Bi{sub 2}Te{sub 3} interface under oxygen and oxygen-free environments, and the results are compared with the corresponding experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

GEOMETRIC AND DYNAMICAL MODELS OF REVERBERATION MAPPING DATA

We present a general method to analyze reverberation (or echo) mapping data that simultaneously provides estimates for the black hole mass and for the geometry and dynamics of the broad-line region (BLR) in active galactic nuclei (AGNs). While previous methods yield a typical scale size of the BLR or a reconstruction of the transfer function, our method directly infers the spatial and velocity distribution of the BLR from the data, from which a transfer function can be easily derived. Previous echo mapping analysis requires an independent estimate of a scaling factor known as the virial coefficient to infer the mass of the black hole, but this is not needed in our more direct approach. We use the formalism of Bayesian probability theory and implement a Markov Chain Monte Carlo algorithm to obtain estimates and uncertainties for the parameters of our BLR models. Fitting of models to the data requires knowledge of the continuum flux at all times, not just the measured times. We use Gaussian Processes to interpolate and extrapolate the continuum light curve data in a fully consistent probabilistic manner, taking the associated errors into account. We illustrate our method using simple models of BLR geometry and dynamics and show that we can recover the parameter values of our test systems with realistic uncertainties that depend upon the variability of the AGN and the quality of the reverberation mapping observing campaign. With a geometry model we can recover the mean radius of the BLR to within {approx}0.1 dex random uncertainty for simulated data with an integrated line flux uncertainty of 1.5%, while with a dynamical model we can recover the black hole mass and the mean radius to within {approx}0.05 dex random uncertainty, for simulated data with a line profile average signal-to-noise ratio of 4 per spectral pixel. These uncertainties do not include modeling errors, which are likely to be present in the analysis of real data, and should therefore be considered as lower limits to the accuracy of the method.

79 ASTRONOMY AND ASTROPHYSICS↗