Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Survey on stochastic distribution systems: A full probability density function control theory with potential applications

Complex systems seen either in general engineering practice or economics are subjected to ever increased uncertainties that are mostly represented as random variables or parameters, and the characteristics of random variables are represented by their probability density functions (PDFs). Controlling their PDFs means to shape their stochastic distributions and in general it would provide a full treatment for system analysis and operational control and optimization. This leads to the development of stochastic distribution control (SDC) systems theory in the past decades, where the original aim of the controller design is to realize a shape control of the distributions of certain random variables in their PDFs sense for some engineering processes. Indeed, once the PDFs of these random variables or parameters are used to describe their distribution characters, the control task is to obtain control signals so that the output PDFs of stochastic systems are made to follow their target PDFs. The subject of SDC was initially originated for non-Gaussian stochastic control systems design but has found a wide spectrum of applications in general systems in terms of data-driven modeling, analysis, signal processing (filtering), data mining via multivariable statistics, decision-making (optimization) for systems subjected to uncertainties and even in economics. In this context, SDC constitutes an effective primer tool for complex system analysis, control and operational optimizations. In this review paper, a detailed survey of the developments on the research of SDC systems will be made together with their wide spectrum applications and future perspectives.

42 ENGINEERING↗

Dynamic Microgrids With Self-Organized Grid-Forming Inverters in Unbalanced Distribution Feeders

In contrast to conventional static microgrids (MGs), MGs with dynamic and adjustable territories (i.e., dynamic MGs) are proposed and implemented in this paper. Dynamic MGs are commonly dominated by grid-forming inverters and nested in unbalanced distribution feeders. Unlike balanced systems where only positive-sequence components exist, proper operation of unbalanced dynamic MGs presents additional challenges. A distributed secondary control strategy is developed in this study for distributed generators (DGs) interfaced with gridforming inverters in unbalanced dynamic MGs by providing coordinated regulations on both positive- and negative-sequence system models. System frequency and voltage are under constant regulation, along with voltage unbalance (VU) management for multiple critical load buses (CLB). The proposed control strategy enables seamless system transition during unbalanced dynamic MGs reconfiguration, and guarantees proportional positive- and negative-sequence power sharing among connected DGs with respect to system topology variation. Detailed controller designs are provided and stability analyses are derived. The proposed control strategy is fully implemented in hardware controllers and validated on a Hardware-in-the-Loop (HIL) MG testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On Per-Phase Topology Control and Switching in Emerging Distribution Systems

This paper presents a new concept and approach for topology control and switching in distribution systems by extending the traditional circuit switching to laterals and single-phase loads. Voltage unbalance and other key performance indicators including voltage magnitudes, line loading, and energy losses are used to characterize and demonstrate the technical value of optimizing system topology on a per-phase basis in response to feeder conditions. The near-optimal per-phase topology control is defined as a series of hierarchical optimization problems. The proposed approach is respectively applied to IEEE 13-bus and 123-bus test systems for demonstration, which included the impact of integrating electric vehicles (EVs) in the test circuit. It is concluded that the proposed approach can be effectively leveraged to improve voltage profiles with electric vehicles, the extent of which depends upon the performance of the base case without EVs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MPC4CLR (Model-Predictive-Control-for-Critical-Load-Restoration-in-Power-Distribution-Systems) [SWR-22-24]

Model predictive control (MPC) is a system or process control technique for making decisions under uncertainty via rolling look-ahead optimizations at each control step where only the current step decisions are applied, and the rest are discarded. In this work, we developed an MPC for a critical load restoration (CLR) in power distribution systems to recover system service (electricity delivery) following an extreme event-triggered substation outage. The method considers the problem of controlling distributed energy resources (DERs) of the distribution system with the objective of achieving maximum load pick up while satisfying distribution network flow and voltage constraints. A linearized optimal power flow (OPF) model is employed to represent the physics of the network. The problem formulation is augmented with a ramping (up) reserve product for the DERs to ensure improved and upward monotonic load restoration as time evolves. Simulation analysis and performance tests are performed using a modified IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage battery. The software is developed using various software packages in Julia and Python. The MPC model is implemented using the JuMP optimization language in Julia while the data analytics including renewable generation and load demand forecasts, running the MPC simulation and visualizations is performed in Python.

Eseye, Abinet Tesfaye↗

Data-Driven Distribution System Coordinated PV Inverter Control Using Deep Reinforcement Learning

The deployment of distributed solar photovoltaic (PV) systems has increased consistently over the past decades. High penetrations of PVs could cause a series of adverse grid impacts, such as voltage violations. The recent development of smart inverter technologies rises the incentives of developing PV control solutions that regulate the inverter output power and seeking the optimization on system operational objectives. This paper proposes a data-driven control solution based on deep reinforcement learning (DRL) to optimize PV inverters for voltage regulation. The proposed solution can minimize PV real power curtailment while maintaining network voltage at an acceptable range. Comparison results between the proposed DRL control algorithms with deep deterministic policy gradient (DDPG) and volt-var control on a real feeder in west Colorado highlight the advantage of the proposed framework in controlling the system voltage while minimizing the PV real power curtailment.

deep reinforcement learning↗

Site-Specific Evaluation of Microgrid Controller Using Controller and Power-Hardware-in-the-Loop: Preprint

Microgrids are built by utilities to improve the resilience and reliability of segments of the distribution system. Controllers with advanced capabilities will operate and control these microgrids with diverse energy technologies, which vary from inverter-based photovoltaics, energy storage systems, and ultra-capacitors to conventional diesel generators. There are multiple challenges to building a microgrid controller for a site because of the unique requirements presented by the controllable and uncontrollable elements in the system. There are also challenges to testing the performance of the microgrid controller for such unique microgrids. The research presented here discusses the challenges to evaluating a microgrid controller for a specific site and provides solutions to those challenges. The paper also presents the controller/power-hardware-in-the-loop evaluation platform built to suit the needs of the microgrid as well as the IEEE 2030.8 consistent test cases used to evaluate the proper operation of the microgrid controller. Finally, the paper presents the results from a subset of the experiments performed to evaluate the microgrid controller. a microgrid controller for a site because of the unique requirements presented by the controllable and uncontrollable elements in the system. There are also challenges to testing the performance of the microgrid controller for such unique microgrids. The research presented here discusses the challenges to evaluating a microgrid controller for a specific site and provides solutions to those challenges. The paper also presents the controller/power-hardware-in-the-loop evaluation platform built to suit the needs of the microgrid as well as the IEEE 2030.8 consistent test cases used to evaluate the proper operation of the microgrid controller. Finally, the paper presents the results from a subset of the experiments performed to evaluate the microgrid controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control of formation of viscoelastic droplets and distribution of nano-inclusions in functional deposition for lithium–sulfur batteries

The electrospray process produces micro/nanodroplets for various applications such as thin and uniform coatings, drug carriers and mass spectrometry. In this paper, we study the spray processes of viscoelastic jets using simulations and experiments. In discretized modeling, the jet is perturbed with axisymmetric instability and the growth of this instability causes the jet to break into droplets. For the experiments, a solution of polyvinyl alcohol in water is sprayed and is visualized using a high-speed camera. The droplet size distribution is studied from simulations with experiments for three spray cases: electrospray, air spray, and air-controlled electrospray. Our simulations and experiments reveal that the electric field is effective in reducing the droplet size, while air flow offers more jet break-ups and thus a larger number of droplets. As a result, air-controlled electrospray where these two driving forces are synergistically combined leads to a larger number of smaller droplets than electrospray or air spray. As a result, we applied three spray processes to obtain a deposition of sulfur/mesoporous carbon/graphene/polymer binder composites as a lithium sulfur battery cathode and demonstrated that air-controlled electrospray leads to a higher capacity and rate capability than other processes, exhibiting 800 mA h g –1 at 0.5C and 600 mA h g –1 at 2C.

25 ENERGY STORAGE↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decentralized Voltage Control of Large-Scale Distribution System with PVs Based on MADRL

This paper proposes a model-free decentralized control framework for the voltage regulation of large-scale distribution systems through the coordinated control of PV inverters. This is achieved by developing a novel interaction mechanism between the surrogate model and the centralized training and decentralized execution multiagent deep reinforcement learning framework. Specifically, the sparse Gaussian processes regression method is first utilized to develop the surrogate model of the original distribution system for reward calculation during the training stage, where each agent represents a sub-region in the centralized fashion for coordination strategy learning. After that, the learned control rules are used to inform controllers within each sub-region for real-time decisions with only local measurements. Comparative tests among various methods on the EPRI Ckt5 test system demonstrate the effectiveness of the proposed method.

distribution system↗

Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends

Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA Workshop on Distributed Parameter Modeling and Control of Flexible Aerospace Systems

Although significant advances have been made in modeling and controlling flexible systems, there remains a need for improvements in model accuracy and in control performance. The finite element models of flexible systems are unduly complex and are almost intractable to optimum parameter estimation for refinement using experimental data. Distributed parameter or continuum modeling offers some advantages and some challenges in both modeling and control. Continuum models often result in a significantly reduced number of model parameters, thereby enabling optimum parameter estimation. The dynamic equations of motion of continuum models provide the advantage of allowing the embedding of the control system dynamics, thus forming a complete set of system dynamics. There is also increased insight provided by the continuum model approach.

Marks, Virginia B.↗

Coordinative Voltage Control Strategy with Multiple Resources for Distribution Systems of High PV Penetration: Preprint

This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has been tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could actively tackle the voltage problem brought about by high penetrations of PV and improve the reliability of distribution system operation.

14 SOLAR ENERGY↗

System and method for operator control of heterogeneous unmanned system teams

A control architecture and associated control methods are under development to allow a single user to control a team of multiple heterogeneous UMS as they conduct multi-faceted (i.e. multi-objective) missions in real time is disclosed. The control architecture is hierarchical, modular and layered and enables operator interaction at each layer, ensuring the human operator is in close control of the unmanned team at all times. The architecture and key data structures are introduced. Two approaches to distributed collaborative control of heterogeneous unmanned systems are described, including an extension of homogeneous swarm control and a novel application of distributed model predictive control. Initial results are presented, demonstrating heterogeneous UMS teams conducting collaborative missions.

47 OTHER INSTRUMENTATION↗

Data Concentrator

Orbital Research, Inc., developed, built, and tested three high-temperature components for use in the design of a data concentrator module in distributed turbine engine control. The concentrator receives analog and digital signals related to turbine engine control and communicates with a full authority digital engine control (FADEC) or high-level command processor. This data concentrator follows the Distributed Engine Controls Working Group (DECWG) roadmap for turbine engine distributed controls communication development that operates at temperatures at least up to 225 C. In Phase I, Orbital Research developed detailed specifications for each component needed for the system and defined the total system specifications. This entailed a combination of system design, compiling existing component specifications, laboratory testing, and simulation. The results showed the feasibility of the data concentrator. Phase II of this project focused on three key objectives. The first objective was to update the data concentrator design modifications from DECWG and prime contractors. Secondly, the project defined requirements for the three new high-temperature, application-specific integrated circuits (ASICs): one-time programmable (OTP), transient voltage suppression (TVS), and 3.3V. Finally, the project validated each design by testing over temperature and under load.

Willett, Mike↗

Streamline integration as a method for two-dimensional elliptic grid generation

We propose a new numerical algorithm to construct a structured numerical elliptic grid of a doubly connected domain. Our method is applicable to domains with boundaries defined by two contour lines of a two-dimensional function. Furthermore, we can adapt any analytically given boundary aligned structured grid, which specifically includes polar and Cartesian grids. The resulting coordinate lines are orthogonal to the boundary. Grid points as well as the elements of the Jacobian matrix can be computed efficiently and up to machine precision. In the simplest case we construct conformal grids, yet with the help of weight functions and monitor metrics we can control the distribution of cells across the domain. Our algorithm is parallelizable and easy to implement with elementary numerical methods. We assess the quality of grids by considering both the distribution of cell sizes and the accuracy of the solution to elliptic problems. Among the tested grids these key properties are best fulfilled by the grid constructed with the monitor metric approach. - Graphical abstract: - Highlights: • Construct structured, elliptic numerical grids with elementary numerical methods. • Align coordinate lines with or make them orthogonal to the domain boundary. • Compute grid points and metric elements up to machine precision. • Control cell distribution by adaption functions or monitor metrics.

97 MATHEMATICS AND COMPUTING↗

Mitigation of fault related voltage swell on distribution feeders using DER-based advanced inverter controls

Unbalanced faults in distribution feeders can impact voltages on the non-faulted phases. This paper models a real-life feeder with a high penetration level of solar photovoltaic (PV) units in detail including the secondary circuits, and shows a large voltage swell in one of the non-faulted phases of the feeder during a single line to ground fault. The voltages seen during this swell are more than 1.2 p.u., which can have detrimental impacts on the connected equipment and can also lead to loss of connected generation. The reason for this voltage swell is found to be the equivalent impedance at the fault location resulting from the ratio of zero and positive sequence cable impedances. It is seen that the connected solar PV units with appropriate control are able to reduce the severity of the voltage swell, especially for higher penetration levels of solar PV considered, but not entirely eliminate it.

14 SOLAR ENERGY↗

Adaptive PID Gain Scheduling Control for Hydropower Turbine Using Neural CDE and Stochastic Distribution Shaping

This paper introduces a gain-scheduling PID controller design strategy for hydroturbine frequency control mode. This scheme first uses real data to learn the nonlinear dynamics of the hydroturbine using neural controlled differential equations and then perturbs the obtained nonlinear system at different equilibrium points, based on which a static output feedback adaptive dynamic programming algorithm is then used to optimize the PID gains for each equilibrium point. Moreover, a continuous-time version of stochastic distribution control is proposed to further fine-tune the optimized PID gains. Finally, the controller is obtained by implementing linear interpolation between the optimized PID control gains. The simulation results show that the proposed gain-scheduling PID controller can control a larger range of operation points compared with the given fixed PID controller and the baseline method. Compared with the given fixed PID controller, the proposed gain-scheduling PID controller can regulate hydroturbine frequency against disturbances induced by power-load variation with over 50% less overshoot for some operation points.

13 HYDRO ENERGY↗

Field Demonstration of Residential DER Service-Oriented Load Participation

Amidst a concerning surge in power consumption during peak hours, coupled with heightened power grid instability, and driven by a growing demand for electricity, aggregations of Distributed Energy Resource are becoming a viable means for providing essential reliability services.Electric utility companies have proactively implemented Demand Response programs for decades. These programs employ Direct Load Control methods to enhance power grid stability, achieved by controlling customers’ Distributed Energy Resource during peak hours to reduce power consumption. However, a notable drawback of Direct Load Control has been high unenrollment rates of DR program participants due to customer discomfort.Therefore, the underlying issue of over-consumption persists. To address these concerns, this paper introduces a Service-Oriented Load Participation approach to providing grid services such as Demand Response. Leveraging a Service-Oriented Architecture, this method offers the advantage of efficient service management and provisioning within the system. The SOLP approach not only aims to reduce power consumption but also to maintain customer satisfaction by ensuring a comfortable grid service experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗