Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Morphological instability of Ag films caused by phase transition in the underlying Ta barrier layer

Wide-bandgap (WBG) semiconductor technologies are maturing and may provide increased device performance in many fields of applications, such as high-temperature electronics. However, there are still issues regarding the stability and reliability of WBG devices. Of particular importance is the high-temperature stability of interconnects for electronic systems based on WBG-semiconductors. For metallization without proper encapsulation, morphological degradation can occur at elevated temperatures. Sandwiching Ag films between Ta and/or TaN layers in this study is found to be electrically and morphologically stabilize the Ag metallization up to 800 °C, compared to 600 °C for uncapped films. However, the barrier layer plays a key role and TaN is found to be superior to Ta, resulting in the best achieved stability, whereas the difference between Ta and TaN caps is negligible. The β-to-α phase transition in the underlying Ta barrier layer is identified as the major cause responsible for the morphological instability observed above 600 °C. It is shown that this phase transition can be avoided using a stacked Ta/TaN barrier.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

International Cybersecurity: Capabilities and Overview [Slides]

Innovations in clean energy technology are beginning to transform electric grids around the world. It is more important than ever to understand and improve the resiliency and security of the grid against natural and human disruptions as our energy systems become more distributed, intelligent, and interconnected. Through its advanced cybersecurity technical assistance portfolio, experts at the National Renewable Energy Laboratory (NREL) work with international governments to support secure and resilient deployment of renewable energy assets and address grid interconnection challenges. Cybersecurity technical assistance is tailored to the needs of our international partners.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DE‐SC0022708 RESEARCH PERFORMANCE FINAL REPORT

GismoPower’s Final Research Report documents the outcomes of a DOE SBIR Phase II project focused on advancing the MEGA® (Mobile Electricity Generating Appliance), a trailerable, plug-in solar canopy appliance designed to deliver appliance-class electricity generation for homes, small businesses and renters. The project’s core objective was to remove the technical and regulatory barriers that have historically prevented plug-in solar systems from being safely certified, permitted, and interconnected in the United States.

14 SOLAR ENERGY↗

Interregional Transmission Operational Coordination (IRTOC)

This report presents a modeling and evaluation framework developed through the Inter-Regional Transmission Operational Coordination (IRTOC) project to study market-to-market (M2M) congestion management across day-ahead and real-time markets. The framework extends the Sienna platform through Sienna Decomposition, a multi-stage evaluation architecture that enables flexible representation of multiple regions and systematic assessment of alternative market coordination designs. Additional modeling capabilities include reserve deliverability constraints, High-Voltage Direct Current (HVDC) optimization for Alternating Current (AC) congestion management, and several real-time distributed coordination algorithms. Case studies using the RTS-GMLC test system and a large-scale Eastern Interconnection model demonstrate that the framework can evaluate alternative coordination structures and quantify their economic and operational impacts. The proposed framework provides a scalable platform for analyzing inter-regional coordination strategies in large-scale electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

reVRt (reV Routing) [SWR-25-112]

The reV Routing (reVRt) tool is a computational framework for modeling and optimizing transmission infrastructure requirements for electrical grid connections. By employing a spatially-aware least-cost-path methodology, it allows users to incorporate a wide range of factors including siting constraints, regional component costs, land composition costs, point-of-interconnection costs, and network upgrade costs. Additionally, the tool enables advanced follow-on analyses, such as land characterization for potential transmission line routes, to support informed decision-making. Although it's designed to integrate seamlessly with the reV model, the reV Routing tool is versatile and can also be utilized independently for standalone analyses in transmission planning and resource assessment scenarios.

Pinchuk, Pavlo (Paul) [National Renewable Energy L↗

Electric Access System Enhancement (EASE): Assessment of a Distributed Energy Resource Management System for Enabling Dynamic Hosting Capacity

The Electric Access System Enhancement (EASE) project demonstrated a scalable, interoperable, and cost-effective means of integrating high penetration of distributed energy resources (DERs). The control architecture developed leveraged a Distributed Energy Resource Management System, Distribution System Operator for transacting energy, and 3rd Party DER Aggregator platform. The project identified ways to enhance the customer interconnection process to the grid and improve access to information from DERs and optimize the usage of DERs to provide energy services in a simulated day-ahead shadow market while maintain grid reliability. By integrating these capabilities into a scalable system of systems, the DSO can effectively balance DER generation and customer demand on the distribution network. This capability allows the grid to host more DER than traditionally possible on wires alone. Hosting more DER has the added benefit of supplying increased demand growth, sometimes beyond the capacity limits of the distribution network itself. This is known as a dynamic hosting capacity, which could help utilities manage the forecasted growth in electricity demand as California switch to electric vehicles and appliances. This could help to establish energy storage and PV generation as a “pseudo firm” generation resource mix if managed appropriately and provide sufficient resource adequacy for distribution capacity upgrade deferrals.

14 SOLAR ENERGY↗

Charge transport model to predict intrinsic reliability for dielectric materials

Several lifetime models, mostly empirical in nature, are used to predict reliability for low-k dielectrics used in integrated circuits. There is a dispute over which model provides the most accurate prediction for device lifetime at operating conditions. As a result, there is a need to transition from the use of these largely empirical models to one built entirely on theory. Therefore, a charge transport model was developed to predict the device lifetime of low-k interconnect systems. The model is based on electron transport and donor-type defect formation. Breakdown occurs when a critical defect concentration accumulates, resulting in electron tunneling and the emptying of positively charged traps. The enhanced local electric field lowers the barrier for electron injection into the dielectric, causing a positive feedforward failure. The charge transport model is able to replicate experimental I-V and I-t curves, capturing the current decay at early stress times and the rapid current increase at failure. The model is based on field-driven and current-driven failure mechanisms and uses a minimal number of parameters. All the parameters have some theoretical basis or have been measured experimentally and are not directly used to fit the slope of the time-to-failure versus applied field curve. Despite this simplicity, the model is able to accurately predict device lifetime for three different sources of experimental data. The simulation's predictions at low fields and very long lifetimes show that the use of a single empirical model can lead to inaccuracies in device reliability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementations and Evaluations of Wind Turbine Inertial Controls With FAST and Digital Real-Time Simulations

This paper presents a novel simulation approach to evaluate new ancillary service controls in the context of large-scale wind power integration. We adopt and compare different types of turbine inertial control methods with the proposed modifications to cope with realistic wind conditions in the field. The simulation procedure is started with the software-based simulation, in which we employ the high-fidelity wind turbine simulator FAST that models a real three-bladed controls advanced research turbine (CART3). The advantages of using FAST are that it can provide convincing simulation results and address the interactions between turbine electrical and mechanical systems. The developed controller model is then rapidly prototyped for the real-time simulation with the hardware-in-the-loop scheme. CART3 will respond to a virtual frequency event triggered in the emulated electric grid modeled in a digital real-time simulator. The introduced simulation platform streamlines the procedure of designing turbine auxiliary controls, and these simulations results give insights on the turbine controls and their impacts on the interconnected power system, as well as the effects on turbine mechanical components. For example, the results indicate that the inertial controls tend to reduce the out-of-plane mechanical loadings in region 2, while such loadings are dominated by the pitch actions in region 3.

17 WIND ENERGY↗

Alternatives to the 15% Rule: Modeling and Hosting Capacity Analysis of 16 Feeders

This project is part of the third solicitation of the California Solar Initiative (CSI3) Research, Development, Demonstration, and Deployment Program created by the California Public Utilities Commission (CPUC) in 2006 to support solar research in California. The program focuses on research to improve the utility application review and approval process for interconnecting distributed energy resources such as solar to the distribution system. The CSI3 program is supporting EPRI, National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) in their collaboration on the process with Pacific Gas and Electric (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E). At present, the application review and approval process is the most time-consuming of any step on the path to generating power for delivery through the distribution system.

14 SOLAR ENERGY↗

Superstructure high efficiency photovoltaics

A novel class of photovoltaic cascade structures is introduced which features multijunction upper subcells. These superstructure high efficiency photovoltaics (SHEP's) exhibit enhanced upper subcell spectral response because of the additional junctions which serve to reduce bulk recombination losses by decreasing the mean collection distance for photogenerated minority carriers. Two possible electrical configurations were studied and compared: a three-terminal scheme that allows both subcells to be operated at their individual maximum power points and a two-terminal configuration with an intercell ohmic contact for series interconnection. The three-terminal devices were found to be superior both in terms of beginning-of-life expectancy and radiation tolerance. Realistic simulations of three-terminal AlGaAs/GaAs SHEP's show that one sun AMO efficiencies in excess of 26 percent are possible.

Wagner, M.↗

Network-Attached Solid-State Recorder Architecture

A document discusses placing memory modules on the high-speed serial interconnect, which is used by a spacecraft s computer elements for inter-processor communications, to allow all multiple computer system architectures to access the spacecraft data storage at the same time. Each memory board is identical electrically and receives its bus ID upon connection to the system. The computer elements are configured in a similar fashion. The architecture allows for multiple memory boards to be accessed simultaneously by different computer elements, and results in a scalable, strong, fault-tolerant system. The IEEE-1393 ring bus can be routed so that multiple card failures can occur and the mass memory storage will still function.

Cox, Brian↗

High-Speed Ring Bus

The high-speed ring bus at the Jet Propulsion Laboratory (JPL) allows for future growth trends in spacecraft seen with future scientific missions. This innovation constitutes an enhancement of the 1393 bus as documented in the Institute of Electrical and Electronics Engineers (IEEE) 1393-1999 standard for a spaceborne fiber-optic data bus. It allows for high-bandwidth and time synchronization of all nodes on the ring. The JPL ring bus allows for interconnection of active units with autonomous operation and increased fault handling at high bandwidths. It minimizes the flight software interface with an intelligent physical layer design that has few states to manage as well as simplified testability. The design will soon be documented in the AS-1393 standard (Serial Hi-Rel Ring Network for Aerospace Applications). The framework is designed for "Class A" spacecraft operation and provides redundant data paths. It is based on "fault containment regions" and "redundant functional regions (RFR)" and has a method for allocating cables that completely supports the redundancy in spacecraft design, allowing for a complete RFR to fail. This design reduces the mass of the bus by incorporating both the Control Unit and the Data Unit in the same hardware. The standard uses ATM (asynchronous transfer mode) packets, standardized by ITU-T, ANSI, ETSI, and the ATM Forum. The IEEE-1393 standard uses the UNI form of the packet and provides no protection for the data portion of the cell. The JPL design adds optional formatting to this data portion. This design extends fault protection beyond that of the interconnect. This includes adding protection to the data portion that is contained within the Bus Interface Units (BIUs) and by adding to the signal interface between the Data Host and the JPL 1393 Ring Bus. Data transfer on the ring bus does not involve a master or initiator. Following bus protocol, any BIU may transmit data on the ring whenever it has data received from its host. There is no centralized arbitration or bus granting. The JPL design provides for autonomous synchronization of the nodes on the ring bus. An address-synchronous latency adjust buffer (LAB) has been designed that cannot get out of synchronization and needs no external input. Also, a priority-driven cable selection behavior has been programmed into each unit on the ring bus. This makes the bus able to connect itself up, according to a maximum redundancy priority system, without the need for computer intervention at startup. Switching around a failed or switched-off unit is also autonomous. The JPL bus provides a map of all the active units for the host computer to read and use for fault management. With regard to timing, this enhanced bus recognizes coordinated timing on a spacecraft as critical and addresses this with a single source of absolute and relative time, which is broadcast to all units on the bus with synchronization maintained to the tens of nanoseconds. Each BIU consists of up to five programmable triggers, which may be programmed for synchronization of events within the spacecraft of instrument. All JPL-formatted data transmitted on the ring bus are automatically time-stamped.

Wysocky, Terry↗

Electric Six Degree of Freedom Installation Timelapse (Six Degree of Freedom Dynamic Test System)

The Six-degree-of-freedom Dynamic Test System (SDTS) is a short-range real-time motion based testing platform. Its primary use at NASA/JSC has been for development and qualification testing of docking systems, robotic assisted berthing mechanisms, and dynamic attachment systems. The SDTS is a closed-loop force feedback system that can simulate on-orbit contact dynamics between two vehicles utilizing the actual mechanical interfaces for testing. The facility is controlled by interconnected computers running real-time simulation software that takes measured contact forces, integrates the equations of motion in real time, and provide those states back into the motion table. This infrastructure can also be used for non-mating applications such as relative position sensor testing/evaluations. The SDTS facility provides a superstructure for mounting test articles, multiple test sensors, an intercom network for voice communications, and a synchronized timing system for data acquisition that includes HD video. This time-lapse video shows the buildup and testing of a modern electric actuation system created by Mikrolar, Inc. at the Johnson Space Center. This motion base will replace the current hydraulic actuator system, which is been in use since the 1970s, for all-future NASA testing. Once the system goes through customization to provide JSC’s unique closed-loop environment, the facility will help certify docking system and attach mechanisms on the ground before we send the first woman and the next man to the lunar surface

hexapod↗

Poster: Responsible Adoption of Artificial Intelligence (AI) in Electric Grid Operations

The rapid integration of artificial intelligence (AI) in the utility transmission and distribution (T&D) sector is revolutionizing traditional grid management practices. As utilities encounter complexities from evolving consumer behaviors and energy integration, AI becomes a critical solution for enhancing grid monitoring, fault detection, and operational optimization. However, increased reliance on interconnected technologies introduces significant cybersecurity risks, regulatory compliance challenges, and human factors concerns. This study proposes a strategic, responsible and consequence-driven approach to AI implementation, examining the dual nature of AI adoption by highlighting its transformative benefits for utilities and associated risks. It provides utilities with a framework for evaluating AI integration, enabling them to navigate challenges and capitalize on opportunities to achieve greater reliability, efficiency, and resilience in an increasingly complex energy landscape.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of PV Module Packaging Strategies of Monofacial and Bifacial PERC Using Degradation Pathway Network Modeling

As the PV industry is rapidly expanding, it is important to thoroughly investigate the long-term impact of packaging strategies on the performance of PV modules. In this study, the variants in sets differ on the basis of manufacturer (A/B), encapsulant (EVA/POE), rear encapsulant (UV-cutoff/opaque/transparent), module architecture (GB/DG) and cell type (monofacial/bifacial). The minimodules were exposed for 2520 hours in modified damp heat, with or without full spectrum light. Every 504 hours, stepwise electrical characterization techniques were employed to track changes in minimodules. Degradation pathway modeling using network structural equation modeling was employed to study pairwise relationships between variables and service lifetime prediction in minimodules. Through this study, differences in quality control are identified in minimodules made by different manufacturers. Minimodules with UV-cutoff rear encapsulant show relatively better stability, whereas the ones with opaque rear encapsulant show greater power loss. In addition, GB having UV-cutoff rear encapsulation and GB with POE having opaque rear encapsulation were identified to be stable as they lack a best model fit. Here, the primary power loss mechanism in degrading variants is interconnect corrosion.

14 SOLAR ENERGY↗

Freestanding NiFe Oxyfluoride Holey Film with Ultrahigh Volumetric Capacitance for Flexible Asymmetric Supercapacitors

In this work, a freestanding NiFe oxyfluoride (NiFeOF) holey film was prepared by electrochemical deposition and anodic treatments. With the combination of good electrical conductivity and holey structure, the NiFeOF holey film offers superior electrochemical performance, due to the following reasons: (i) The residual metal alloy framework can be used as the current collector to improve electrode conductivity. Moreover, the as-prepared freestanding NiFeOF holey film can be used as a supercapacitor electrode without reliance on binders and other additives. The residual metal alloy framework and binder-free electrode effectively reduces electrode resistance, thus improving electron transport. (ii) The highly interconnected holey structure and hierarchical pore distribution provides a high specific surface area to improve electron transport, enhancing rapid ion transport and mitigating diffusion limitations throughout the holey film. (iii) The excellent mechanical characteristics facilitate flexibility and cyclability related performance. Additionally, the NiFeOF holey film presents exceptional electrochemical performance, showing that it is a promising alternative for small/micro-size electronic devices.

holey film↗

Distributed Embedded Energy Converter Technologies for Marine Renewable Energy (A Technical Report)

The domain of distributed embedded energy converter technologies (DEEC-Tec) is a nascent and underexplored paradigm for harvesting and converting marine renewable energy. The paradigm distinguishes itself through its use of many small distributed embedded energy converters (DEECs) that, ultimately, are assembled through the creation of "DEEC-Tec metamaterials" to create an overall larger marine renewable energy harvesting and converting structure. As an example, such a structure could be an ocean wave energy converter - a converter whose structure is made from various types of DEEC-Tec metamaterials that harvests ocean wave energy and converts that energy into something more useful such as electricity. To that end, DEEC-Tec can be viewed at three different technology levels: (1) individual distributed embedded energy converters, also known as DEECs; (2) DEEC-Tec metamaterials-essentially, pseudo-materials made from the interconnection of many DEECs; and (3) overall larger complete marine renewable energy harvesting-converting structures-these structures being made from DEEC-Tec metamaterials. Arising directly from the application of DEEC-Tec to harvest and convert ocean wave energy are several noteworthy benefits, some of which include: (1) the lack of load concentrations into singular components or subsystems, (2) broad-banded ocean wave energy frequency harvesting and conversion, and (3) inherent redundancy-failure of some individual DEECs does not represent a failure of an entire DEEC-Tec-based WEC. This report describes DEEC-Tec by way of descriptions of those three technology levels: individual DEECs, DEEC-Tec metamaterials, and DEEC-Tec-based WECs. Moreover, the report describes corresponding research approaches and methodologies for related concepts such as DEEC-Tec-based WEC topologies and morphologies in addition to manufacturing and fabrication techniques found suitable for the application of DEEC-Tec within the general domain of marine renewable energy-moving beyond only ocean wave energy conversion.

16 TIDAL AND WAVE POWER↗

Reliability of Sn/Pb and Lead-Free (SnAgCu) Solders of Surface Mounted Miniaturized Passive Components for Extreme Temperature (-185 C to +125 C) Space Missions

Surface mount electronic package test boards have been assembled using tin/lead (Sn/Pb) and lead-free (Pb-free or SnAgCu or SAC305) solders. The soldered surface mount packages include ball grid arrays (BGA), flat packs, various sizes of passive chip components, etc. They have been optically inspected after assembly and subsequently subjected to extreme temperature thermal cycling to assess their reliability or future deep space, long-term, extreme temperature environmental missions. In this study, the employed temperature range (-185oC to +125oC) covers military specifications (-55oC to +100oC), extreme old Martian (-120oC to +115oC), asteroid Nereus (-180oC to +25oC) and JUNO (-150oC to +120oC) environments. The boards were inspected at room temperature and at various intervals as a function of extreme temperature thermal cycling and bake duration. Electrical resistance measurements made at room temperature are reported and the tests to date have shown some change in resistance as a function of extreme temperature thermal cycling and some showed increase in resistance. However, the change in interconnect resistance becomes more noticeable with increasing number of thermal cycles. Further research work will be carried out to understand the reliability of packages under extreme temperature applications (-185oC to +125oC) via continuously monitoring the daisy chain resistance for BGA, Flat-packs, lead less chip packages, etc. This paper will describe the experimental reliability results of miniaturized passive components (01005, 0201, 0402, 0603, 0805, and 1206) assembled using surface mounting processes with tin-lead and lead-free solder alloys under extreme temperature environments.