Search NASA⌕ Search

SEARCH · Search NASA

Results for “error rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Highly Reliable, High-Speed, Unidirectional Serial Data Links

Highly reliable, high-speed, unidirectional serial data-communication subsystems have been proposed to be installed in an upgrade of the computing systems aboard the space shuttles. The basic design concept of these serial data links is also adaptable to terrestrial use in applications in which there are requirements for highly reliable serial data communications. The hardware and software aspects of the architecture of the data links are dictated largely by a requirement, in the original space-shuttle application, for one computer to monitor the memory transactions and memory contents of other computers in real time with high reliability and without reliance on requests for retransmission. To minimize weight while affording a capability to transfer data at a required rate of 2.56 x 10(exp 8) bits per second, it was decided that the links would be serial ones of the fiber-channel type. [Fiber channel denotes a type of serial computer bus that is used to connect a computer (usually a supercomputer) with a high-speed data storage device. Depending on the specific application, the physical connection between the transmitter and receiver could be made via an optical fiber or a twisted pair of wires.] Heretofore, fiber-channel links have ordinarily been bidirectional and have operated under protocols that provide for receiving stations to detect errors and request retransmission when necessary. In the present case, the time taken by processing to request retransmission would conflict with the requirement for real-time transfer of data. To ensure reliability without retransmission, a link according to the proposal would utilize a modified version of the normal fiberchannel character set in conjunction with forward error correction by means of a Reed-Solomon code (see figure). The Reed-Solomon encoding and decoding and the translations between the normal and modified character sets would be effected by logic circuitry external to the fiber-channel transmitter and receiver, which would be commercial off-the-shelf units. The receiving end of the link could detect and correct errors at a rate as high as 4 million times per second, if necessary. The receiver detects uncorrectable double-byte errors. It has been estimated that uncorrectable-error rate would amount to one failure in about 10(exp 19) characters.

Cole, Robert M.↗

Application of GRS method to evaluation of uncertainties of calculation parameters of perspective sodium-cooled fast reactor

A number of recent studies have been devoted to the estimation of errors of reactor calculation parameters by the GRS (Generation Random Sampled) method. This method is based on direct sampling input data resulting in formation of random sets of input parameters which are used for multiple calculations. Once these calculations are performed, statistical processing of the calculation results is carried out to determine the mean value and the variance of each calculation parameter of interest. In our study this method is used for estimation of errors of calculation parameters (K{sub eff}, power density, dose rate) of a perspective sodium-cooled fast reactor. Neutron transport calculations were performed by the nodal diffusion code TRIGEX and Monte Carlo code MMK. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing Parameters for Deep-Space Optical Communication

A paper discusses the optimization of the parameters of a high-rate, deep-space optical communication link that utilizes pulse-position modulation (PPM) and an error-correcting code (ECC). The parameters in question include the PPM order (number of pulse time slots in one symbol period), the ECC rate, and the uncoded symbol error rate. In simple terms, the optimization problem is to choose the combination of these parameters that maximizes the throughput data rate at a given bit-error-rate (BER), subject to several constraints, including limits on the average and peak power and possibly a limit on the uncoded symbol error rate. This is a complex, multidimensional optimization problem, the solution of which involves computation of channel capacities for various combinations of the parameters. The paper presents extensive theoretical analyses and numerical predictions that elucidate the many facets of the optimization problem. It shows how a nearly optimum solution can be obtained by choosing the optimum PPM order for the desired number of bits per slot and concatenating the PPM mapping with an error-correction code so that the decoded bits satisfy some BER threshold.

Moison, Bruce↗

Human Error Analysis for Human-Rated Space Systems

Humans bring unique capabilities to space systems and contribute to mission success in a manner that cannot be matched by machines. Nevertheless, from time to time, human error can present a threat to system performance, and system designers must anticipate and manage this risk. NASA’s Human-Rating Requirements for Space Systems call for program managers to conduct a human error analysis (HEA) during system development but does not specify how to do this. In 2018, NASA’s Engineering and Safety Center asked the authors to develop a guidance document on HEA. The resulting position paper outlines a suggested method for HEA and makes it clear that error analysis is about identifying and mitigating problems at a system level, and not about finding fault with individuals. Error management strategies must be directed at error-producing conditions, thereby reducing the likelihood of human error, while retaining the positive contribution that humans make to system operations.

human error human-rated space↗

A measurement-based performability model for a multiprocessor system

A measurement-based performability model based on real error-data collected on a multiprocessor system is described. Model development from the raw errror-data to the estimation of cumulative reward is described. Both normal and failure behavior of the system are characterized. The measured data show that the holding times in key operational and failure states are not simple exponential and that semi-Markov process is necessary to model the system behavior. A reward function, based on the service rate and the error rate in each state, is then defined in order to estimate the performability of the system and to depict the cost of different failure types and recovery procedures.

Ilsueh, M. C.↗

Quality and Safety in Emergency Radiology

Purpose of Review: To review and outline problems and challenges in regard to patient safety along with solutions to overcome them. Recent Findings: Errors and discrepancies in radiology practice are disappointingly common. The estimated rate of errors is more than 5% in many targeted studies. This requires a detailed review of different types of errors in radiology and potential strategies to prevent them. Summary: An effective health care delivery system relies heavily on high degrees of skill in professionalism and communication. Strategies to prevent errors and improve communication with physicians in the Emergency Department are helpful in providing quality patient care, thus also decreasing the chances of conflicts and litigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrosion of the International Simple Glass under acidic to hyperalkaline conditions

Assessment of glass dissolution kinetics, under disposal relevant temperature and pH environments, is required to credibly estimate radionuclide release rates from vitrified radioactive waste. Leaching of the International Simple Glass (ISG) under acidic to hyperalkaline conditions was examined. Forward rate measurements have been obtained using the dynamic leaching SPFT protocol and rate parameters for B, Na and Si in the basic regime; errors in rates predicted using these parameters at high pH and temperature are significant because the fitting uses logarithmic data. Longer term behaviour under hyperalkaline conditions, representative of some disposal environments, was investigated using the PCT and MCC-1 static leaching protocols with Ca(OH) 2 solutions for up to 120 days (PCT) and 720 days (MCC-1). In hyperalkaline conditions dissolution was incongruent for all elements and the presence of alternating zirconia-rich and zirconia-poor alteration layers was viewed on all leached monoliths, indicating the occurrence of a self-organisation phenomenon during leaching.

36 MATERIALS SCIENCE↗

Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy

Purpose: The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. Methods: The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-filled ion chambers arranged over an area of 11 × 11 cm. The size of the detectors is 2.3 × 2.3 × 0.5 mm (volume of 0.003 cm{sup 3}) and their spacing in the inner area of 5.5 × 5.5 cm is 2.5 mm center-to-center, whereas in the outer area it is 5 mm center-to-center. The detector reproducibility, dose linearity, and sensitivity to positional changes of the collimator were tested. Also, the output factors of field sizes ranging from 0.5 × 0.5 to 10 × 10 cm{sup 2} both for open and wedged fields have been measured and compared against those measured by a pin-point ionization chamber, liquid filled microchamber, SRS diode, and EDR2 film. Results: Its short-term reproducibility was within 0.2% and its medium and long-term reproducibility was within 0.5% (verified with air ionization chamber absolute dose measurements), which is an excellent result taking into account the daily fluctuation of the linear accelerator and the errors in the device setup reproducibility. The dose linearity and dose rate dependence were measured in the range of 0.5–85 Gy and 0.5–10 Gy min{sup −1}, respectively, and were verified with air ionization chamber absolute dose measurements was within 3%. The measurements of the sensitivity showed that the 2D Array could detect millimetric collimator positional changes. The measured output factors showed an agreement of better than 0.3% with the pinpoint chamber and microliquid filled chamber for the field sizes between 3 × 3 and 10 × 10 cm{sup 2}. For field sizes down to 1 × 1 cm{sup 2}, the agreement with SRS diode and microliquid filled chamber is better than 2%. The measurements of open and wedge-modulated field profiles were compared to the film and ionization chamber in water measurements. Conclusions: The Octavius Detector 1000 SRS is an accurate, precise, and reliable detector, very useful for the daily performance of the patient specific quality assurance of radiotherapy treatment plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance

Purpose: High dose rate brachytherapy (HDR-BT) is widely used to treat gynecologic, anal, prostate, head, neck, and breast cancers. These treatments are typically administered in large dose per fraction (>5 Gy) and with high-gradient-dose-distributions, with serious consequences in case of a treatment delivery error (e.g., on dwell position and dwell time). Thus, quality assurance (QA) or quality control (QC) should be systematically and independently implemented. This paper describes the design and testing of a phantom and an instrumented gynecological applicator for pretreatment QA and in vivo QC, respectively. Methods: The authors have designed a HDR-BT phantom equipped with four GaN-based dosimeters. The authors have also instrumented a commercial multichannel HDR-BT gynecological applicator by rigid incorporation of four GaN-based dosimeters in four channels. Specific methods based on the four GaN dosimeter responses are proposed for accurate determination of dwell time and dwell position inside phantom or applicator. The phantom and the applicator have been tested for HDR-BT QA in routine over two different periods: 29 and 15 days, respectively. Measurements in dwell position and time are compared to the treatment plan. A modified position–time gamma index is used to monitor the quality of treatment delivery. Results: The HDR-BT phantom and the instrumented applicator have been used to determine more than 900 dwell positions over the different testing periods. The errors between the planned and measured dwell positions are 0.11 ± 0.70 mm (1σ) and 0.01 ± 0.42 mm (1σ), with the phantom and the applicator, respectively. The dwell time errors for these positions do not exhibit significant bias, with a standard deviation of less than 100 ms for both systems. The modified position–time gamma index sets a threshold, determining whether the treatment run passes or fails. The error detectability of their systems has been evaluated through tests on intentionally introduced error protocols. With a detection threshold of 0.7 mm, the error detection rate on dwell position is 22% at 0.5 mm, 96% at 1 mm, and 100% at and beyond 1.5 mm. On dwell time with a dwell time threshold of 0.1 s, it is 90% at 0.2 s and 100% at and beyond 0.3 s. Conclusions: The proposed HDR-BT phantom and instrumented applicator have been tested and their main characteristics have been evaluated. These systems perform unsupervised measurements and analysis without prior treatment plan information. They allow independent verification of dwell position and time with accuracy of measurements comparable with other similar systems reported in the literature.

60 APPLIED LIFE SCIENCES↗

Effects of dynamic aeroelasticity on handling qualities and pilot rating

Pilot performance parameters, such as pilot ratings, tracking errors, and pilot comments were determined for a longitudinal pitch tracking task using a large, flexible bomber with parametric variations in the undamped natural frequencies of the two lowest frequency symmetric elastic modes. This pitch tracking task was programmed on a fixed base simulator with an electronic attitude-director display of pitch command, pitch angle, and pitch error. Low frequency structural flexibility significantly affects the handling qualities and pilot ratings in the task evaluated.

Yen, W. Y.↗

ADEPT, a dynamic next generation sequencing data error-detection program with trimming

Illumina is the most widely used next generation sequencing technology and produces millions of short reads that contain errors. These sequencing errors constitute a major problem in applications such as de novo genome assembly, metagenomics analysis and single nucleotide polymorphism discovery. In this study, we present ADEPT, a dynamic error detection method, based on the quality scores of each nucleotide and its neighboring nucleotides, together with their positions within the read and compares this to the position-specific quality score distribution of all bases within the sequencing run. This method greatly improves upon other available methods in terms of the true positive rate of error discovery without affecting the false positive rate, particularly within the middle of reads. We conclude that ADEPT is the only tool to date that dynamically assesses errors within reads by comparing position-specific and neighboring base quality scores with the distribution of quality scores for the dataset being analyzed. The result is a method that is less prone to position-dependent under-prediction, which is one of the most prominent issues in error prediction. The outcome is that ADEPT improves upon prior efforts in identifying true errors, primarily within the middle of reads, while reducing the false positive rate.

59 BASIC BIOLOGICAL SCIENCES↗

Direct simulation Monte Carlo study of effects of thermal nonuniformities in electron-beam physical vapor deposition

In a typical electron-beam physical vapor deposition system, there is limited control over how the high-power electron beam heats the metal surface. This leads to thermal nonuniformities at the melt. Three-dimensional direct simulation Monte Carlo simulations were performed with the aim of quantifying the effect of such spatial variations of source temperature in thin film depositions using an electron-beam physical vapor deposition system. The source temperature distribution from a typical deposition process was used in the direct simulation Monte Carlo simulations performed for various mass flow rates. The use of an area-averaged temperature is insufficient for all mass flow rates due to the highly nonlinear relationship between temperature and saturation number density, and hence, the mass flux. The mass flow rate equivalent temperature was determined, and the simulations performed with this temperature were compared with those corresponding to the actual nonuniform temperature distribution. For low mass flow rates, the growth rates depend very weakly on the spatial variation of temperature as long as an equivalent temperature corresponding to the same mass flow rate was used. However, as the mass flow rate increases, the error associated with this approximation increases. For deposition processes with source Knudsen numbers less than 0.05, it is not possible to account for the spatial nonuniformities in temperature using the total mass flow rate without significant errors. For a given mass flow rate, the errors associated with using an equivalent temperature decrease with increasing collector plane distance since the flow is allowed to expand further, thereby decreasing the effects of slit temperature nonuniformities.

36 MATERIALS SCIENCE↗

Satellite-based snow identification and its impact on monitoring photovoltaic systems

Earth observation allows the separation of snow cover and cloudiness using multispectral measurements. Several satellite-based snow monitoring services are available, ranging from regional to world-wide scales. Using these data enables photovoltaic (PV) plant management to differentiate between failures due to snow coverage on a PV system and other error sources. Additionally, yield estimates for solar siting are improved. This paper presents a validation study from January to April 2006 comparing satellite-based datasets with ground measurements from German and Swiss meteorological stations. A false alarm rate, an error due to irradiance underestimation, the availability of daily data, and the classification accuracy are introduced as quality metrics. Compared to Switzerland, generally a higher accuracy is found in all datasets for Southern Germany. The most significant difference among the datasets is found in the error pattern shifting from too much snow (which results in an error due to underestimation of irradiance) to too little snow detection, causing a false alarm in PV monitoring. Overall, the data records of the Land Surface Analysis Satellite Application Facility (LSA SAF), the German Aerospace Center (DLR) and the Interactive Multisensor Snow and Ice Mapping System (IMS) are found to be most suitable for solar energy purposes. The IMS dataset has a low false alarm rate (4%) and a good data availability (100%) making it a good choice for power plant monitoring, but the error due to underestimation relevant in site auditing is large with 59%. If a cumulative snow cover algorithm is applied to achieve information every day as needed both for power plant monitoring and site auditing, both the DLR and the LSA SAF datasets are comparable with classification accuracies of 70%, false alarm rates of 37% and 34%, respectively, and errors due to irradiance underestimation in 26% and 27% of all coincidences. (author)

14 SOLAR ENERGY↗

Rates of adsorption and desorption: Entropic contributions and errors due to mean-field approximations

We have performed exact classical rate calculations to compute adsorption and desorption rate constants with a model representative of a real system. We compute the desorption rate using transition-state theory by taking the dividing-surface far from the surface of the solid. We find that using a mean-field assumption, i.e., applying potential of mean force to transition state theory, could lead to two orders-of-magnitude errors in the rate constant owing to large fluctuations in the desorption barrier. Furthermore, we compute the adsorption rate by including a dynamical factor which reflects the probability of sticking to the solid surface. We find that the sticking probability is highly sensitive to the coverage. Also, we find that the adsorption rate computed from the mean-field assumption is not very different from the exact adsorption rate. We also compute entropic contribution to desorption rates and compare it to that obtained from two limiting models of adsorption—2D ideal gas and 2D ideal lattice gas. We show that at high temperatures (700 K), the entropic contribution to desorption rates computed from the exact calculations is very close to that obtained from the 2D ideal gas model. However, for lower to intermediate temperatures from 200 K to 500 K, the entropic contributions cover a wide range which lies in between the two limiting models and could lead to over two-orders-of-magnitude errors in the rate coefficient.

Activation energies↗

Improving TCP Network Performance by Detecting and Reacting to Packet Reordering

There are many factors governing the performance of TCP-basec applications traversing satellite channels. The end-to-end performance of TCP is known to be degraded by the reordering, delay, noise and asymmetry inherent in geosynchronous systems. This result has been largely based on experiments that evaluate the performance of TCP in single flow tests. While single flow tests are useful for deriving information on the theoretical behavior of TCP and allow for easy diagnosis of problems they do not represent a broad range of realistic situations and therefore cannot be used to authoritatively comment on performance issues. The experiments discussed in this report test TCP s performance in a more dynamic environment with competing traffic flows from hundreds of TCP connections running simultaneously across the satellite channel. Another aspect we investigate is TCP's reaction to bit errors on satellite channels. TCP interprets loss as a sign of network congestion. This causes TCP to reduce its transmission rate leading to reduced performance when loss is due to corruption. We allowed the bit error rate on our satellite channel to vary widely and tested the performance of TCP as a function of these bit error rates. Our results show that the average performance of TCP on satellite channels is good even under conditions of loss as high as bit error rates of 10(exp -5)

Kruse, Hans↗