Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

One- and two-qubit gate infidelities due to motional errors in trapped ions and electrons

In this work, we derive analytic formulas that determine the effect of error mechanisms on one- and two-qubit gates in trapped ions and electrons. First, we analyze and derive expressions for the effect of driving field inhomogeneities on one-qubit gate fidelities. Second, we derive expressions for two-qubit gate errors, including static motional frequency shifts, trap anharmonicities, field inhomogeneities, heating, and motional dephasing. We show that, for small errors, each of our expressions for infidelity converges to its respective numerical simulation; this shows that our formulas are sufficient for determining error budgets for high-fidelity gates, obviating numerical simulations in future projects. All of the derivations are general to any internal qubit state, and any mixed state of the ion crystal's motion that is diagonal in the Fock state basis. Our treatment of static motional frequency shifts, trap anharmonicities, heating, and motional dephasing apply to both laser-based and laser-free gates, while our treatment of field inhomogeneities applies to laser-free systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Loschmidt-echo approach to error estimation in Krylov-subspace approximation

The Krylov subspace method is a traditional approach to approximate quantum evolution, allowing us to treat systems with large Hilbert spaces. Despite its popularity, current bounds typically overestimate the error, which translates into more expensive simulation routines. Here, in this paper, we tackle this problem by realizing that the error can be understood as a Loschmidt echo in a one-dimensional (1D) noninteracting tight-binding Hamiltonian. We show that the different time regimes of the approximation can be understood using simple physical ideas. More importantly, we obtain computationally cheap error bounds that describe with high precision the actual error in the approximation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multispin Clifford codes for angular momentum errors in spin systems

The physical symmetries of a system play a central role in quantum error correction. Here, in this work we encode a qubit in a collection of systems with angular momentum symmetry (spins), extending the tools developed by Gross for single large spins. By considering large spins present in atomic systems and focusing on their collective symmetric subspace, we develop codes with octahedral symmetry capable of correcting errors up to second order in angular momentum operators. These errors include the most physically relevant noise sources such as microwave control errors and optical pumping. We additionally explore qubit codes that exhibit distance scaling commensurate with the surface code while permitting transversal single-qubit Clifford operations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rethinking CO adsorption on transition-metal surfaces: Effect of density-driven self-interaction errors

Adsorption of the molecule CO on metallic surfaces is an important unsolved problem in Kohn-Sham density functional theory (KS-DFT). We present a detailed study of carbon monoxide adsorption on fcc (111) surfaces of 3d, 4d, and 5d metals using nonempirical semilocal density functionals for the exchange-correlation energy: the local-density approximation (LDA), two generalized gradient approximations or GGAs [Perdew-Burke-Ernzerhof (PBE) and PBE for solids (PBEsol)], and a meta-GGA [strongly constrained and appropriately normed (SCAN) functional]. The typical error pattern (as found earlier for free molecules and for free transition-metal surfaces), in which results improve from LDA to PBE or PBEsol to SCAN, due to the satisfaction of more exact constraints, is not found here. Instead, for CO adsorption on transition-metal surfaces, we find that, while SCAN overbinds much less than LDA, it overbinds slightly more than PBE. Moreover, the tested functionals often predict the wrong adsorption site, as first pointed out for LDA and GGA in the CO/Pt (111) puzzle. This abnormal pattern leads us to suspect that the errors of PBE and SCAN for this problem are density-driven self-interaction errors associated with incorrect charge transfer between molecule and metal surface. We point out that, by the variational principle, overbinding by an approximate functional would be reduced if that functional were applied not to its self-consistent density for the adsorbed system but to an exact or more correct density for that system. Finally, we show for CO on Pt(111) that the site preference is corrected and the adsorption energy is improved for the PBE functional by using not the self-consistent PBE density but a PBE+U density. The resulting correction to the PBE total energy is much larger for the adsorbed system than for its desorbed components, showing that the error is in the density of the adsorbed system. Furthermore, this seems to solve the Feibelman 2001 CO/Pt(111) puzzle, in principle if not fully in practice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simple model to investigate jet quenching and correlated errors for centrality-dependent nuclear modification factors in relativistic heavy-ion collisions

Here, we apply Bayesian techniques to compare a simple, empirical model for jet quenching in heavy-ion collisions to centrality-dependent jet R AA measured by ATLAS for Pb + Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV. We find that the R AA values for central collisions are adequately described with a model for the mean p T -dependent jet energy loss using only two parameters. This model is extended by incorporating two-dimensional initial geometry information from TRENTo and compared to centrality-dependent R AA values. We find that the results are sensitive to the value of the jet-quenching formation time, τ ƒ , and that the optimal value of τ ƒ varies with the assumed path-length dependence of the energy loss. We construct a covariance error matrix for the data from the p T -dependent contributions to the ATLAS systematic errors and perform Bayesian calibrations for several different assumptions for the systematic error correlations. We show that the most-probable functions and $χ^2_d$ values are sensitive to assumptions made when fitting to correlated errors. This work demonstrates the utility of a simple model that can quickly demonstrate the constraining power of jet-quenching observables with corresponding uncertainties and guide future studies using more sophisticated models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying the impact of precision errors on quantum approximate optimization algorithms

The quantum approximate optimization algorithm (QAOA) is a hybrid quantum-classical algorithm that seeks to achieve approximate solutions to optimization problems by iteratively alternating between intervals of controlled quantum evolution. Here, we examine the effect of analog precision errors on QAOA performance from the perspective of both algorithmic training and performance guarantees. Leveraging cumulant expansions, we recast the faulty QAOA as a control problem in which precision errors are expressed as multiplicative control noise and derive bounds on the performance of QAOA. We show using both analytical techniques and numerical simulations that fixed precision implementations of QAOA circuits are subject to an exponential degradation in performance dependent upon the number of optimal QAOA layers and magnitude of the precision error. Despite this significant reduction, we show that it is possible to mitigate precision errors in QAOA via digitization of the variational parameters at the cost of increasing circuit depth.

quantum algorithms↗

Inverse Volume Scaling of Finite-Size Error in Periodic Coupled Cluster Theory

Coupled cluster theory is one of the most popular post-Hartree-Fock methods for molecular quantum chemistry. The finite-size error of the correlation energy in periodic coupled cluster calculations for three-dimensional insulating systems has been observed to satisfy the inverse volume scaling, even in the absence of any correction schemes. This is surprising, as simpler theories that utilize only a subset of the coupled cluster diagrams exhibit much slower decay of the finite-size error, which scales inversely with the length of the system. In this study, we review the current understanding of finite-size error in quantum chemistry methods for periodic systems. We introduce new tools that elucidate the mechanisms behind this phenomenon in the context of coupled cluster doubles calculations. This reconciles some seemingly paradoxical statements related to finite-size scaling. Our findings also show that singularity subtraction can be a powerful method to effectively reduce finite-size errors in practical quantum chemistry calculations for periodic systems. Published by the American Physical Society 2024

97 MATHEMATICS AND COMPUTING↗

Trotter Errors from Dynamical Structural Instabilities of Floquet Maps in Quantum Simulation

We study the behavior of errors in the quantum simulation of spin systems with long-range multibody interactions resulting from the Trotter-Suzuki decomposition of the time-evolution operator. We identify a regime where the Floquet operator underlying the Trotter decomposition undergoes sharp changes even for small variations in the simulation step size. This results in a time evolution operator that is very different from the dynamics generated by the targeted Hamiltonian, which leads to a proliferation of errors in the quantum simulation. These regions of sharp change in the Floquet operator, referred to as structural instability regions, appear typically at intermediate Trotter step sizes and in the weakly interacting regime, and are thus complementary to recently revealed quantum chaotic regimes of the Trotterized evolution [L. M. Sieberer et al. npj Quantum Inf. 5, 78 (2019); M. Heyl, P. Hauke, and P. Zoller, Sci. Adv. 5, eaau8342 (2019)]. We characterize these structural instability regimes in p-spin models, transverse-field Ising models with all-to-all p-body interactions, and analytically predict their occurrence based on unitary perturbation theory. We further show that the effective Hamiltonian associated with the Trotter decomposition of the unitary time-evolution operator, when the Trotter step size is chosen to be in the structural instability region, is very different from the target Hamiltonian, which explains the large errors that can occur in the simulation in the regions of instability. These results have implications for the reliability of near-term gate-based quantum simulators, and reveal an important interplay between errors and the physical properties of the system being simulated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shadow Distillation: Quantum Error Mitigation with Classical Shadows for Near-Term Quantum Processors

Mitigating errors in quantum information processing devices is especially important in the absence of fault tolerance. An effective method in suppressing state-preparation errors is using multiple copies to distill the ideal component from a noisy quantum state. Here, we use classical shadows and randomized measurements to circumvent the need for coherent access to multiple copies at an exponential cost. We study the scaling of resources using numerical simulations and find that the overhead is still favorable compared to full state tomography. We optimize measurement resources under realistic experimental constraints and apply our method to an experiment preparing a Greenberger-Horne-Zeilinger state with trapped ions. In addition to improving stabilizer measurements, the analysis of the improved results reveals the nature of errors affecting the experiment. Hence, our results provide a directly applicable method for mitigating errors in near-term quantum computers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative evaluation of statistical errors in small-angle X-ray scattering measurements

A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ 2 ( q ) = [ I ( q ) + const.]/( kq ), where I ( q ) is the scattering intensity as a function of the momentum transfer q ; k and const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurement errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Algorithmic and Software Pipeline for Very Large Scale Scientific Data Compression with Error Guarantees

Efficient data compression is becoming increasingly critical for storing scientific data because many scientific applications produce vast amounts of data. This paper presents an end-to-end algorithmic and software pipeline for data compression that guarantees both error bounds on primary data (PD) and derived data, known as Quantities of Interest (QoI).We demonstrate the effectiveness of the pipeline by compressing fusion data generated by a large-scale fusion code, XGC, which produces tens of petabytes of data in a single day. We demonstrate that the compression is conducted by setting aside computational resources known as staging nodes, and does not impact the simulation performance. For efficient parallel I/O, the pipeline uses ADIOS2, which many codes such as XGC already use for their parallel I/O. We show that our approach can compress the data by two orders of magnitude while guaranteeing high accuracy on both the PD and the QoIs. Further, the amount of resources required by compression is a few percent of the resources required by simulation while ensuring that the compression time for each stage is less than the corresponding simulation time.This pipeline consists of three main steps. The first step decomposes the data using domain decomposition into small subdomains. Each subdomain is then compressed independently to achieve a high level of parallelism. The second step uses existing techniques that guarantee error bounds on the primary data for each subdomain. The third step uses a post-processing optimization technique based on Lagrange multipliers to reduce the QoI errors for data corresponding to each subdomain. The Lagrange multipliers generated can be further quantized or truncated to increase the compression level. All of the above characteristics of our approach make it highly practical to apply on-the-fly compression while guaranteeing errors on QoIs that are critical to the scientists.

Banerjee, Tania↗

Soft Syndrome Decoding of Quantum LDPC Codes for Joint Correction of Data and Syndrome Errors

Quantum errors are primarily detected and corrected using the measurement of syndrome information which itself is an unreliable step in practical error correction implementations. Typically, such faulty or noisy syndrome measurements are modeled as a binary measurement outcome flipped with some probability. However, the measured syndrome is in fact a discretized value of the continuous voltage or current values obtained in the physical implementation of the syndrome extraction. In this paper, we use this "soft" or analog information without the conventional discretization step to benefit the iterative decoders for decoding quantum low-density parity-check (QLDPC) codes. Syndrome-based iterative belief propagation (BP) decoders are modified to utilize the syndrome-soft information to successfully correct both data and syndrome errors simultaneously, without repeated measurements. We demonstrate the advantages of extracting the soft information from the syndrome in our improved decoders, not only in terms of comparison of thresholds and logical error rates for quasi-cyclic lifted-product QLDPC code families, but also for faster convergence of iterative decoders. In particular, the new BP decoder with noisy syndrome performs as good as the standard BP decoder under ideal syndrome.

97 MATHEMATICS AND COMPUTING↗

Error-controlled Progressive Retrieval of Scientific Data under Derivable Quantities of Interest

The unprecedented amount of scientific data has introduced heavy pressure on the current data storage and transmission systems. Progressive compression has been proposed to mitigate this problem, which offers data access with on-demand precision. However, existing approaches only consider precision control on primary data, leaving uncertainties on the quantities of interest (QoIs) derived from it. In this work, we present a progressive data retrieval framework with guaranteed error control on derivable QoIs. Our contributions are three-fold. (1) We carefully derive the theories to strictly control QoI errors during progressive retrieval. Our theory is generic and can be applied to any QoIs that can be composited by the basis of derivable QoIs proved in the paper. (2) We design and develop a generic progressive retrieval framework based on the proposed theories, and optimize it by exploring feasible progressive representations. (3) We evaluate our framework using five real-world datasets with a diverse set of QoIs. Experiments demonstrate that our framework can faithfully respect any user-specified QoI error bounds in the evaluated applications. This leads to over 2.02× performance gain in data transfer tasks compared to transferring the primary data while guaranteeing a QoI error that is less than 1E-5.

Wu, Xuan↗

An Accurate, Error-Tolerant, and Energy-Efficient Neural Network Inference Engine Based on SONOS Analog Memory

In this work, we demonstrate SONOS (silicon-oxide-nitrideoxide- silicon) analog memory arrays that are optimized for neural network inference. The devices are fabricated in a 40nm process and operated in the subthreshold regime for in-memory matrix multiplication. Subthreshold operation enables low conductances to be implemented with low error, which matches the typical weight distribution of neural networks, which is heavily skewed toward near-zero values. This leads to high accuracy in the presence of programming errors and process variations. We simulate the end-to-end neural network inference accuracy, accounting for the measured programming error, read noise, and retention loss in a fabricated SONOS array. Evaluated on the ImageNet dataset using ResNet50, the accuracy using a SONOS system is within 2.16% of floating-point accuracy without any retraining. The unique error properties and high On/Off ratio of the SONOS device allow scaling to large arrays without bit slicing, and enable an inference architecture that achieves 20 TOPS/W on ResNet50, a >10× gain in energy efficiency over state-of-the-art digital and analog inference accelerators.

97 MATHEMATICS AND COMPUTING↗

Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy

Purpose: The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Methods: Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with {sup 192}Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from {+-}5 to {+-}15 mm) were simulated in software in order to assess the ability of the system to detect errors. Results: For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a {+-}15 mm displacement error increased by a factor of 1.5 or more. Conclusions: In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biological consequences of MLC calibration errors in IMRT delivery and QA

Purpose: The purpose of this work is threefold: (1) to explore biological consequences of the multileaf collimator (MLC) calibration errors in intensity modulated radiotherapy (IMRT) of prostate and head and neck cancers, (2) to determine levels of planning target volume (PTV) and normal tissue under- or overdose flagged with clinically used QA action limits, and (3) to provide biologically based input for MLC QA and IMRT QA action limits. Methods: Ten consecutive prostate IMRT cases and ten consecutive head and neck IMRT cases were used. Systematic MLC offsets (i.e., calibration error) were introduced for each control point of the plan separately for X1 and X2 leaf banks. Offsets were from - 2 to 2 mm with a 0.5 mm increment. The modified files were imported into the planning system for forward dose recalculation. The original plan served as the reference. The generalized equivalent uniform dose (gEUD) was used as the biological index for the targets, rectum, parotid glands, brainstem, and spinal cord. Each plan was recalculated on a CT scan of a 27 cm diameter cylindrical phantom with a contoured 0.6 cc ion chamber. Dose to ion chamber and 3D gamma analysis were compared to the reference plan. QA pass criteria: (1) at least 95% of voxels with a dose cutoff of 50% of maximum dose have to pass at 3 mm/3% and (2) dose to chamber within 2% of the reference dose. Results: For prostate cases, differences in PTV and rectum gEUD greater than 2% were identified. However, a larger proportion of plans leading to greater than 2% difference in prostate PTV gEUD passed the ion chamber QA but not 3D gamma QA. A similar trend was found for the rectum gEUD. For head and neck IMRT, the QA pass criteria flagged plans leading to greater than 4% differences in PTV gEUD and greater than 5% differences in the maximum dose to brainstem. If pass criteria were relaxed to 90% for gamma and 3% for ion chamber QA, plans leading to a 5% difference in PTV gEUD and a 5%-8% difference in brainstem maximum dose would likely pass IMRT QA. A larger proportion of head and neck plans with greater than 2% PTV gEUD difference passed 3D gamma QA compared to ion chamber QA. Conclusions: For low modulation plans, there is a better chance to catch MLC calibration errors with 3D gamma QA rather than ion chamber QA. Conversely, for high modulation plans, there is a better chance to catch MLC calibration errors with ion chamber QA rather than with 3D gamma QA. Ion chamber and 3D gamma analysis IMRT QA can detect greater than 2% change in gEUD for PTVs and critical structures for low modulation treatment plans. For high modulation treatment plans, ion chamber and 3D gamma analysis can detect greater than 2% change in gEUD for PTVs and a 5% change in critical structure gEUD since either QA methods passes the QA criteria. For gEUD changes less than those listed above, either QA method has the same proportion of passing rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction, seven required a single correction, one required two corrections, and one required three corrections. Mean residual GTV deviation (3D distance) following GTV-based systematic correction (mean {+-} 1 standard deviation 4.8 {+-} 1.5 mm) is significantly lower than for systematic skeletal-based (6.5 {+-} 2.9 mm, p= 0.015), and weekly skeletal-based correction (7.2 {+-} 3.0 mm, p= 0.001), but is not significantly lower than daily skeletal-based correction (5.4 {+-} 2.6 mm, p= 0.34). In two cases, first-day CBCT images reveal tumor changes-one showing tumor growth, the other showing large tumor displacement-that are not readily observed in radiographs. Differences in computed GTV deviations between respiration-correlated and respiration-averaged images are 0.2 {+-} 1.8 mm in the superior-inferior direction and are of similar magnitude in the other directions. Conclusions: An off-line protocol to correct GTV-based systematic error in locally advanced lung tumor cases can be effective at reducing tumor deviations, although the findings need confirmation with larger patient statistics. In some cases, a single cone-beam CT can be useful for assessing tumor changes early in treatment, if more than a few days elapse between simulation and the start of treatment. Tumor deviations measured with respiration-averaged CT and CBCT images are consistent with those measured with respiration-correlated images; the respiration-averaged method is more easily implemented in the clinic.

60 APPLIED LIFE SCIENCES↗

Analysis of Errors in Recording and Reading of a Holographic Prism on Photothermorefractive Glass

The influence of deviation of recording and reading conditions of multiplex Bragg gratings from calculated values on the parameters of restorable fan of beams of a holographic prism (HP) formed by Bragg gratings in photothermorefractive glass is analyzed. Deviations are specified either as a rotation of the sample around one of three orthogonal axes Oxyz or as simultaneous rotation of the sample around two axes. It is shown that errors in the sample installation do not affect quality of the HP in recording if all gratings are recorded with the same deviation from an ideal position. However, difference in errors at the recording of each grating results is a reduction of flatness of fan of the HP and a loss of its working capacity. Ultimate values of errors of rotation around the Ox and Oy axes allowing one to maintain HP functionality, i.e., simultaneous reconstruction of all its beams, are calculated. It is established that, in the case of an ideally recorded HP, errors in the stage of reading may result in twisting the fan and disrupting its flatness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗