Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors and uncertainties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Weighing 'El Gordo' with a precision scale: Hubble space telescope weak-lensing analysis of the merging galaxy cluster ACT-CL J0102–4915 at z = 0.87

We present a Hubble Space Telescope weak-lensing study of the merging galaxy cluster 'El Gordo' (ACT-CL J0102–4915) at z = 0.87 discovered by the Atacama Cosmology Telescope (ACT) collaboration as the strongest Sunyaev-Zel'dovich decrement in its ∼1000 deg{sup 2} survey. Our weak-lensing analysis confirms that ACT-CL J0102–4915 is indeed an extreme system consisting of two massive (≳ 10{sup 15} M {sub ☉} each) subclusters with a projected separation of ∼0.7 h{sub 70}{sup −1} Mpc. This binary mass structure revealed by our lensing study is consistent with the cluster galaxy distribution and the dynamical study carried out with 89 spectroscopic members. We estimate the mass of ACT-CL J0102–4915 by simultaneously fitting two axisymmetric Navarro-Frenk-White (NFW) profiles allowing their centers to vary. We use only a single parameter for the NFW mass profile by enforcing the mass-concentration relation from numerical simulations. Our Markov-Chain-Monte-Carlo analysis shows that the masses of the northwestern (NW) and the southeastern (SE) components are M{sub 200c}=(1.38±0.22)×10{sup 15} h{sub 70}{sup −1} M{sub ⊙} and (0.78±0.20)×10{sup 15} h{sub 70}{sup −1} M{sub ⊙}, respectively, where the quoted errors include only 1σ statistical uncertainties determined by the finite number of source galaxies. These mass estimates are subject to additional uncertainties (20%-30%) due to the possible presence of triaxiality, correlated/uncorrelated large scale structure, and departure of the cluster profile from the NFW model. The lensing-based velocity dispersions are 1133{sub −61}{sup +58} km s{sup −1} and 1064{sub −66}{sup +62} km s{sup −1} for the NW and SE components, respectively, which are consistent with their spectroscopic measurements (1290 ± 134 km s{sup –1} and 1089 ± 200 km s{sup –1}, respectively). The centroids of both components are tightly constrained (∼4'') and close to the optical luminosity centers. The X-ray and mass peaks are spatially offset by ∼8'' (∼62 h{sub 70}{sup −1} kpc), which is significant at the ∼2σ confidence level. The mass peak, however, does not lead the gas peak in the direction expected if we are viewing the cluster soon after first core passage during a high speed merger. Under the assumption that the merger is happening in the plane of the sky, extrapolation of the two NFW halos to a radius r{sub 200a}=2.4 h{sub 70}{sup −1} Mpc yields a combined mass of M{sub 200a}=(3.13±0.56)×10{sup 15} h{sub 70}{sup −1} M{sub ⊙}. This extrapolated total mass is consistent with our two-component-based dynamical analysis and previous X-ray measurements, projecting ACT-CL J0102–4915 to be the most massive cluster at z > 0.6 known to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Moments of nucleon isovector structure functions in 2+1+1-flavor QCD

We present results on the isovector momentum fraction, $\langle x \rangle_{u–d}$ , helicity moment, $\langle x \rangle_{Δ u–Δd}$ , and the transversity moment, $\langle x \rangle_{δu–δd}$, of the nucleon obtained using nine ensembles of gauge configurations generated by the MILC Collaboration using 2 + 1 + 1 -flavors of dynamical highly improved staggered quarks. The correlation functions are calculated using the Wilson-Clover action, and the renormalization of the three operators is carried out nonperturbatively on the lattice in the RI'–MOM scheme. The data have been collected at lattice spacings a ≈ 0.15 , 0.12, 0.09, and 0.06 fm and $M_π$ ≈ 310 , 220, and 135 MeV, which are used to obtain the physical values using a simultaneous chiral-continuum-finite-volume fit. The final results, in the $\overline{\text{MS}}$ scheme at 2 GeV, are $\langle$ x $\rangle$ u – d = 0.173 ( 14 ) ( 07 ) , $\langle x \rangle_{Δu–Δd}$ = 0.213 ( 15 ) ( 22 ) , and $\langle x \rangle_{δu–δd}$ = 0.208 ( 19 ) ( 24 ) , where the first error is the overall analysis uncertainty and the second is an additional systematic uncertainty due to possible residual excited-state contributions. These results are consistent with other recent lattice calculations and phenomenological global fit values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for B{sub s}{sup 0{yields}}hh decays at the {Upsilon}(5S) resonance

We have searched for B{sub s}{sup 0{yields}}hh decays, where h stands for a charged or neutral kaon, or a charged pion. These results are based on a 23.6 fb{sup -1} data sample collected with the Belle detector on the {Upsilon}(5S) resonance at the KEKB asymmetric-energy e{sup +}e{sup -} collider, containing 1.25x10{sup 6} B{sub s}{sup (*)}B{sub s}{sup (*)} events. We observe the decay B{sub s}{sup 0{yields}}K{sup +}K{sup -} and measure its branching fraction, B(B{sub s}{sup 0{yields}}K{sup +}K{sup -})=[3.8{sub -0.9}{sup +1.0}(stat){+-}0.5(syst){+-}0.5(f{sub s})]x10{sup -5}. The first error is statistical, the second is systematic, and the third error is due to the uncertainty in the B{sub s}{sup 0} production fraction in e{sup +}e{sup -{yields}}bb events. No significant signals are seen in other decay modes, and we set upper limits at the 90% confidence level: B(B{sub s}{sup 0{yields}}K{sup -{pi}+})<1.2x10{sup -5}, B(B{sub s}{sup 0{yields}{pi}+{pi}-})<2.6x10{sup -5}, and B(B{sub s}{sup 0{yields}}K{sup 0}K{sup 0})<6.6x10{sup -5}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

$Z$-Boson Pole Mass at Two-Loop Order in the Pure $\overline{MS}$ Scheme

I obtain the complex pole squared mass of the Z boson at full two-loop order in the Standard Model in the pure MS¯ renormalization scheme. The input parameters are the running gauge couplings, the top-quark Yukawa coupling, the Higgs self-coupling, and the vacuum expectation value that minimizes the Landau gauge effective potential. The effects of nonzero Goldstone boson mass are resummed. Within a reasonable range of renormalization scale choices, the scale dependence of the computed pole mass is found to be comparable to the current experimental uncertainty, but the true theoretical error is likely somewhat larger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of nuclear interactions in polyethylene range compensators for carbon-ion radiotherapy

Purpose: A recent study revealed that polyethylene (PE) would cause extra carbon-ion attenuation per range shift by 0.45%/cm due to compositional differences in nuclear interactions. The present study aims to assess the influence of PE range compensators on tumor dose in carbon-ion radiotherapy. Methods: Carbon-ion radiation was modeled to be composed of primary carbon ions and secondary particles, for each of which the dose and the relative biological effectiveness (RBE) were estimated at a tumor depth in the middle of spread-out Bragg peak. Assuming exponential behavior for attenuation and yield of these components with depth, the PE effect on dose was calculated for clinical carbon-ion beams and was partly tested by experiment. The two-component model was integrated into a treatment-planning system and the PE effect was estimated in two clinical cases. Results: The attenuation per range shift by PE was 0.1%–0.3%/cm in dose and 0.2%–0.4%/cm in RBE-weighted dose, depending on energy and range-modulation width. This translates into reduction of RBE-weighted dose by up to 3% in extreme cases. In the treatment-planning study, however, the effect on RBE-weighted dose to tumor was typically within 1% reduction. Conclusions: The extra attenuation of primary carbon ions in PE was partly compensated by increased secondary particles for tumor dose. In practical situations, the PE range compensators would normally cause only marginal errors as compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response.

60 APPLIED LIFE SCIENCES↗

SU-E-T-268: Proton Radiosurgery End-To-End Testing Using Lucy 3D QA Phantom

Purpose: To check the overall accuracy of proton radiosurgery treatment delivery using ready-made circular collimator inserts and fixed thickness compensating boluses. Methods: Lucy 3D QA phantom (Standard Imaging Inc. WI, USA) inserted with GaFchromicTM film was irradiated with laterally scattered and longitudinally spread-out 126.8 MeV proton beams. The tests followed every step in the proton radiosurgery treatment delivery process: CT scan (GE Lightspeed VCT), target contouring, treatment planning (Odyssey 5.0, Optivus, CA), portal calibration, target localization using robotic couch with image guidance and dose delivery at planned gantry angles. A 2 cm diameter collimator insert in a 4 cm diameter radiosurgery cone and a 1.2 cm thick compensating flat bolus were used for all beams. Film dosimetry (RIT114 v5.0, Radiological Imaging Technology, CO, USA) was used to evaluate the accuracy of target localization and relative dose distributions compared to those calculated by the treatment planning system. Results: The localization accuracy was estimated by analyzing the GaFchromic films irradiated at gantry 0, 90 and 270 degrees. We observed 0.5 mm shift in lateral direction (patient left), ±0.9 mm shift in AP direction and ±1.0 mm shift in vertical direction (gantry dependent). The isodose overlays showed good agreement (<2mm, 50% isodose lines) between measured and calculated doses. Conclusion: Localization accuracy depends on gantry sag, CT resolution and distortion, DRRs from treatment planning computer, localization accuracy of image guidance system, fabrication of ready-made aperture and cone housing. The total deviation from the isocenter was 1.4 mm. Dose distribution uncertainty comes from distal end error due to bolus and CT density, in addition to localization error. The planned dose distribution was well matched (>90%) to the measured values 2%/2mm criteria. Our test showed the robustness of our proton radiosurgery treatment delivery system using ready-made collimator inserts and fixed thickness compensating boluses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-399: Evaluation of Selection Criteria for Computational Human Phantoms for Use in Out-Of-Field Organ Dosimetry for Radiotherapy Patients

Purpose: To quantify the dosimetric uncertainty due to organ position errors when using height and weight as phantom selection criteria in the UF/NCI Hybrid Phantom Library for the purpose of out-of-field organ dose reconstruction. Methods: Four diagnostic patient CT images were used to create 7-field IMRT plans. For each patient, dose to the liver, right lung, and left lung were calculated using the XVMC Monte Carlo code. These doses were taken to be the ground truth. For each patient, the phantom with the most closely matching height and weight was selected from the body size dependent phantom library. The patient plans were then transferred to the computational phantoms and organ doses were recalculated. Each plan was also run on 4 additional phantoms with reference heights and or weights. Maximum and mean doses for the three organs were computed, and the DVHs were extracted and compared. One sample t-tests were performed to compare the accuracy of the height and weight matched phantoms against the additional phantoms in regards to both maximum and mean dose. Results: For one of the patients, the height and weight matched phantom yielded the most accurate results across all three organs for both maximum and mean doses. For two additional patients, the matched phantom yielded the best match for one organ only. In 13 of the 24 cases, the matched phantom yielded better results than the average of the other four phantoms, though the results were only statistically significant at the .05 level for three cases. Conclusion: Using height and weight matched phantoms does yield better results in regards to out-of-field dosimetry than using average phantoms. Height and weight appear to be moderately good selection criteria, though this selection criteria failed to yield any better results for one patient.

60 APPLIED LIFE SCIENCES↗

Advanced Computational Framework for Environmental Management ZEM, Version 1.x

Typically environmental management problems require analysis of large and complex data sets originating from concurrent data streams with different data collection frequencies and pedigree. These big data sets require on-the-fly integration into a series of models with different complexity for various types of model analyses where the data are applied as soft and hard model constraints. This is needed to provide fast iterative model analyses based on the latest available data to guide decision-making. Furthermore, the data and model are associated with uncertainties. The uncertainties are probabilistic (e.g. measurement errors) and non-probabilistic (unknowns, e.g. alternative conceptual models characterizing site conditions). To address all of these issues, we have developed an integrated framework for real-time data and model analyses for environmental decision-making called ZEM. The framework allows for seamless and on-the-fly integration of data and modeling results for robust and scientifically-defensible decision-making applying advanced decision analyses tools such as Bayesian- Information-Gap Decision Theory (BIG-DT). The framework also includes advanced methods for optimization that are capable of dealing with a large number of unknown model parameters, and surrogate (reduced order) modeling capabilities based on support vector regression techniques. The framework is coded in Julia, a state-of-the-art high-performance programing language (http://julialang.org). The ZEM framework is open-source and can be applied to any environmental management site. The framework will be open-source and released under GPL V3 license.

Vesselinov, VelimirV.↗

Study of |Vtd/Vts| Using a Sum of Exclusive B → X Gamma Final States Reconstructed With the BaBar Detector

Experimental data collected with the BABAR detector consisting of 470.9 ± 2.8 million BB events are used to measure the sum of seven exclusive B → X d(s) γ transitions, where X d(s) is any non-strange (strange) charmless hadronic state. For each transition avour, measurements are made in the hadronic mass ranges 0.5 ≤ mX < 1.0 GeV=c 2 and 1.0 ≤ m X ≤ 2.0 GeV=c 2 . These are extrapolated and combined in a model-dependent way to obtain the ratio of the total branching fractions, B(B→ X dγ )=B(B→ X sγ ) = 0.0456 ± 0.0110 ± 0.0097 where the first error is statistical and the second error is systematic. This is interpreted as a measurement of the ratio of CKM matrix elements |V td /V ts | = 0.211 ± 0.023 ± 0.022 ± 0.001 where the final error is due to theoretical uncertainty.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

(U) Jezebel Densities and Uncertainties

The 239 Pu Jezebel benchmark is a keystone for plutonium nuclear data evaluation. At a recent presentation at a nuclear data workshop, Morgan White (LANL P-27) presented a slide about the Jezebel plutonium-alloy part densities and their uncertainties. There are two major errors and one opinion presented as fact.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extreme Scale Infrasound Inversion and Prediction for Weather Characterization and Acute Event Detection

Accurate and timely weather predictions are critical to many aspects of society with a profound impact on our economy, general well-being, and national security. In particular, our ability to forecast severe weather systems is necessary to avoid injuries and fatalities, but also important to minimize infrastructure damage and maximize mitigation strategies. The weather community has developed a range of sophisticated numerical models that are executed at various spatial and temporal scales in an attempt to issue global, regional, and local forecasts in pseudo real time. The accuracy however depends on the time period of the forecast, the nonlinearities of the dynamics, and the target spatial resolution. Significant uncertainties plague these predictions including errors in initial conditions, material properties, data, and model approximations. To address these shortcomings, a continuous data collection occurs at an effort level that is even larger than the modeling process. It has been demonstrated that the accuracy of the predictions depends on the quality of the data and is independent to a certain extent on the sophistication of the numerical models. Data assimilation has become one of the more critical steps in the overall weather prediction business and consequently substantial improvements in the quality of the data would have transformational benefits. This paper describes the use of infrasound inversion technology, enabled through exascale computing, that could potentially achieve orders of magnitude improvement in data quality and therefore transform weather predictions with significant impact on many aspects of our society.

58 GEOSCIENCES↗

Assessment of Crustal Leg Uncertainties for RSTT Path-dependent Uncertainty

The Regional Seismic Travel Time (RSTT) model and software were recently updated to allow for path-dependent uncertainty (PDU) estimates for travel-time (Begnaud et al. 2021; Begnaud et al. 2020). Begnaud et al. (2021) describes the process of improving the current distance-dependent uncertainty parameterization for RSTT using a random effects model (REM) to estimate slowness (inverse velocity) uncertainty as a mean squared error for each model parameter. The REM separates the error between observed slowness and model predicted slowness into bias and random components. The PDU is calculated by integrating these mean squared errors along a seismic-phase ray path.

58 GEOSCIENCES↗

Practical CO2—WAG Field Operational Designs Using Hybrid Numerical-Machine-Learning Approaches

Machine-learning technologies have exhibited robust competences in solving many petroleum engineering problems. The accurate predictivity and fast computational speed enable a large volume of time-consuming engineering processes such as history-matching and field development optimization. The Southwest Regional Partnership on Carbon Sequestration (SWP) project desires rigorous history-matching and multi-objective optimization processes, which fits the superiorities of the machine-learning approaches. Although the machine-learning proxy models are trained and validated before imposing to solve practical problems, the error margin would essentially introduce uncertainties to the results. In this paper, a hybrid numerical machine-learning workflow solving various optimization problems is presented. By coupling the expert machine-learning proxies with a global optimizer, the workflow successfully solves the history-matching and CO2 water alternative gas (WAG) design problem with low computational overheads. The history-matching work considers the heterogeneities of multiphase relative characteristics, and the CO2-WAG injection design takes multiple techno-economic objective functions into accounts. This work trained an expert response surface, a support vector machine, and a multi-layer neural network as proxy models to effectively learn the high-dimensional nonlinear data structure. The proposed workflow suggests revisiting the high-fidelity numerical simulator for validation purposes. The experience gained from this work would provide valuable guiding insights to similar CO2 enhanced oil recovery (EOR) projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of instrumentation error effects on the identification accuracy of aircraft parameters

An analytical investigation is presented of the effect of unmodeled measurement system errors on the accuracy of aircraft stability and control derivatives identified from flight test data. Such error sources include biases, scale factor errors, instrument position errors, misalignments, and instrument dynamics. Two techniques (ensemble analysis and simulated data analysis) are formulated to determine the quantitative variations to the identified parameters resulting from the unmodeled instrumentation errors. The parameter accuracy that would result from flight tests of the F-4C aircraft with typical quality instrumentation is determined using these techniques. It is shown that unmodeled instrument errors can greatly increase the uncertainty in the value of the identified parameters. General recommendations are made of procedures to be followed to insure that the measurement system associated with identifying stability and control derivatives from flight test provides sufficient accuracy.

Sorensen, J. A.↗

Tests and comparisons of gravity models.

Optical observations of the GEOS satellites were used to obtain orbital solutions with different sets of geopotential coefficients. The solutions were compared before and after modification to high order terms (necessary because of resonance) and were then analyzed by comparing subsequent observations with predicted trajectories. The most important source of error in orbit determination and prediction for the GEOS satellites is the effect of resonance found in most published sets of geopotential coefficients. Modifications to the sets yield greatly improved orbits in most cases. The results of these comparisons suggest that with the best optical tracking systems and gravity models, satellite position error due to gravity model uncertainty can reach 50-100 m during a heavily observed 5-6 day orbital arc. If resonant coefficients are estimated, the uncertainty is reduced considerably.

Marsh, J. G.↗

Absolute judgment for one- and two-dimensional stimuli embedded in Gaussian noise

This study examines the effect on human performance of adding Gaussian noise or disturbance to the stimuli in absolute judgment tasks involving both one- and two-dimensional stimuli. For each selected stimulus value (both an X-value and a Y-value were generated in the two-dimensional case), 10 values (or 10 pairs of values in the two-dimensional case) were generated from a zero-mean Gaussian variate, added to the selected stimulus value and then served as the coordinate values for the 10 points that were displayed sequentially on a CRT. The results show that human performance, in terms of the information transmitted and rms error as functions of stimulus uncertainty, was significantly reduced as the noise variance increased.

Kvalseth, T. O.↗

Flight evaluation of a simplified gross thrust calculation technique using an F100 turbofan engine in an F-15 airplane

A simplified gross thrust calculation technique was evaluated in flight tests on an F-15 aircraft using prototype F100-PW-100 engines. The technique relies on afterburner duct pressure measurements and empirical corrections to an ideal one-dimensional analysis to determine thrust. In-flight gross thrust calculated by the simplified method is compared to gross thrust calculated by the engine manufacturer's gas generator model. The evaluation was conducted at Mach numbers from 0.6 to 1.5 and at altitudes from 6000 meters to 13,700 meters. The flight evaluation shows that the simplified gross thrust method and the gas generator method agreed within plus or minus 3 percent. The discrepancies between the data generally fell within an uncertainty band derived from instrumentation errors and recording system resolution.

Kurtenbach, F. J.↗

Pulsed multiwavelength laser ranging system

A pulsed multiwavelength laser ranging system for measuring atmospheric delay was built and tested, and its theoretical performance limits were calculated. The system uses a dye modelocked ND:YAG laser, which transmits 70 psec wide pulses simultaneously at 1064, 532, and 355 nm. The differential delay of the 1064 and 355 nm pulses is measured by a specially calibrated waveform digitizer to estimate the dry atmospheric delay. The delay time of the 532 nm pulse is used to measure the target distance. Static crossed field photomultipliers are used as detectors for all wavelengths. Theoretical analysis shows that path curvature and atmospheric turbulence are fundamental limits to the ranging accuracy of both single and multicolor systems operating over horizontal paths. For two color systems, an additional error is caused by the uncertainty in the path averaged water vapor. The standard deviation of the multicolor instrument's timing measurements is directly proportional to the laser pulse width plus photomultiplier jitter divided by the square root of the received photoelectron number. The prototype system's maximum range is km, which is limited by atmospheric and system transmission losses at 355 nm. System signal detection and false alarm calculations are also presented.

Abshire, J. B.↗