Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Value and Technology Assessment to Enhance the Business Case for the CERTS Microgrid

The CERTS Microgrid concept is an advanced approach for enabling integration of, in principle, an unlimited quantity of distributed energy resources into the electricity grid. A key feature of a microgrid, is its ability, during a utility grid disturbance, to separate and isolate itself from the utility seamlessly with no disruption to the loads within the microgrid (including no reduction in power quality). Then, when the utility grid returns to normal, the microgrid automatically resynchronizes and reconnects itself to the grid, in an equally seamless fashion. What is unique about the CERTS Microgrid is that it can provide this technically challenging functionality without extensive (i.e., expensive) custom engineering. In addition, the design of the CERTS Microgrid also provides high system reliability and great flexibility in the placement of distributed generation within the microgrid. The CERTS Microgrid offers these functionalities at much lower costs than traditional approaches by incorporating peer-to-peer and plug-and-play concepts for each component within the Microgrid. The predecessor to the current project involved the construction of and completion of initial testing using the world's first, full-scale, inverter-based, distributed generation test bed. The project demonstrated three advanced techniques, collectively referred to as the CERTS Microgrid concept, which collectively significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques are: (1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; (2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and (3) a method for microgrid control that achieves voltage and frequency stability under both grid and islanded conditions without requiring high-speed communications. The work conducted in this phase of RD&D on the CERTS Microgrid Concept builds upon this base of technical accomplishments to prioritize, develop, and then demonstrate technology enhancements to further enhance the business case for microgrids. That is, having demonstrated the technical feasibility of microgrid functions, RD&D optimization efforts are now needed to accelerate commercial deployment. The current phase is a contribution to these efforts. This project involved seven distinct analysis, bench-, and full-scale testing tasks. The first five tasks were described in the original proposal submitted and awarded through DOE's solicitation. Two additional tasks were added to address issues that had been identified in the earlier, first phase of testing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Neonatal Zika virus infection causes transient perineuronal net degradation

Perineuronal nets (PNNs) form a specialized extracellular matrix that predominantly surrounds parvalbumin (PV)-expressing GABAergic inhibitory interneurons and help regulate neuronal activity. Their formation early in the postnatal period is regulated by neuronal signaling and glial activation raising concerns that part of the long-term effects ascribed to perinatal viral infections could be mediated by altered PNN formation. Previously, we developed a model of neonatal Zika virus (ZIKV) infection where mice have lifelong neurological sequelae that includes motor disfunction and reduced anxiety coupled with a persistent low-grade expression in proinflammatory markers despite resolving the acute infection. Here, we demonstrate that ZIKV infection to P1 neonatal mice results in a reduction of PNN formation during the acute disease with significant reduction in Wisteria floribunda agglutinin (WFA) staining at the peak of infection [15 days post infection (dpi)] that persisted after the symptoms resolved (30 dpi). At 60 dpi, when there is residual inflammation in the CNS, the number of WFA + cells and the level of WFA staining as well as levels of aggrecan and brevican in the brains of convalescent mice were not different from those in uninfected controls, however, there was increased frequency of PNNs with an immature phenotype. Over time the impact of the perinatal infection became less evident and there were no clear differences in PNN morphology between the groups at 1 year post infection. Of note, the reduction in PNNs during acute ZIKV infection was not associated with decreased mRNA levels of aggrecan or brevican, but increased levels of degraded aggrecan and brevican indicating increased PNN degradation. These changes were associated with increased expression of matrix metalloproteinase 12 (MMP12) and MMP19, but not MMP9, a disintegrin and metalloproteinase with thrombospondin motifs 4 (ADAMTS4) or ADAMTS5. Together our findings indicate that infection at the time of PNN development interferes with PNN formation, but the nets can reform once the infection and inflammation subside.

60 APPLIED LIFE SCIENCES↗

Altering Terahertz Sound Propagation in a Liquid upon Nanoparticle Immersion

One of the grand challenges of new generation Condensed Matter physicists is the development of novel devices enabling the control of sound propagation at terahertz frequency. Indeed, phonon excitations in this frequency window are the leading conveyor of heat transfer in insulators. Their manipulation is thus critical to implementing heat management based on the structural design. To explore the possibility of controlling the damping of sound waves, we used high spectral contrast Inelastic X-ray Scattering (IXS) to comparatively study terahertz acoustic damping in a dilute suspension of 50 nm nanospheres in glycerol and on pure glycerol. Bayesian inference-based modeling of measured spectra indicates that, at sufficiently large distances, the spectral contribution of collective modes in the glycerol suspension becomes barely detectable due to the enhanced damping, the weakening, and the slight softening of the dominant acoustic mode.

36 MATERIALS SCIENCE↗

Method and apparatus for enhanced detection of toxic agents

A biosensor based detection of toxins includes enhancing a fluorescence signal by concentrating a plurality of photosynthetic organisms in a fluid into a concentrated region using biased AC electro-osmosis. A measured photosynthetic activity of the photosynthetic organisms is obtained in the concentrated region, where chemical, biological or radiological agents reduce a nominal photosynthetic activity of the photosynthetic organisms. A presence of the chemical, biological and/or radiological agents or precursors thereof, is determined in the fluid based on the measured photosynthetic activity of the concentrated plurality of photosynthetic organisms. A lab-on-a-chip system is used for the concentrating step. The presence of agents is determined from feature vectors, obtained from processing a time dependent signal using amplitude statistics and/or time-frequency analysis, relative to a control signal. A linear discriminant method including support vector machine classification (SVM) is used to identify the agents.

47 OTHER INSTRUMENTATION↗

EMAT enhanced dispersion of particles in liquid

Particulate matter is dispersed in a fluid material. A sample including a first material in a fluid state and second material comprising particulate matter are placed into a chamber. The second material is spatially dispersed in the first material utilizing EMAT force. The dispersion process continues until spatial distribution of the second material enables the sample to meet a specified criterion. The chamber and/or the sample is electrically conductive. The EMAT force is generated by placing the chamber coaxially within an induction coil driven by an applied alternating current and placing the chamber and induction coil coaxially within a high field magnetic. The EMAT force is coupled to the sample without physical contact to the sample or to the chamber, by another physical object. Batch and continuous processing are utilized. The chamber may be folded within the bore of the magnet. Acoustic force frequency and/or temperature may be controlled.

36 MATERIALS SCIENCE↗

Operation of an SRF Cavity Tuner Submerged into Liquid Helium

There are several projects is going at FNAL that required to tune bare (undressed) SRF cavities when they sub-merged into superfluid Helium. We have used LCLS II tuner [1] mounted on the special mechanical structure to tune single cell 1.3 GHz cavity. To precisely control the resonance of 1.3GHz SRF cavi-ties during testing at the FNAL’s Vertical Test Facility, we install for the first time a double lever tuner and operate it when submerged into the liquid He bath. Both active com-ponents of the tuner: electromechanical actuator (stepper motor) and piezo-actuators are operated inside superfluid helium. Accuracy in controlling the SRF cavity resonance frequency will be presented. Specifics of the tuner opera-tion when submerged into liquid He will be discussed.

43 PARTICLE ACCELERATORS↗

Conventional and Next Generation Treatment Technologies for PFAS - 20067

In 2016, the United States Environmental Protection Agency (USEPA) established a Health Advisory Limit (HAL) for perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) (individually and the summation) of 70 nanograms per liter (ng/L) based on developing toxicological information. These two compounds are among several thousand per- and polyfluoroalkyl substances (PFAS). Due to a multitude of commercially beneficial physical and chemical properties, the availability of PFAS-relevant and practical water treatment technologies is limited. The use of conventional adsorbents, such as activated carbon (AC) and anion exchange (AIX) resins, have become a 'de facto' interim measure to immediately address drinking water above this criterion. However, these adsorbents can have marginal long-term efficiency and are relatively unproven against the diversity of polyfluorinated compounds. Additionally, geochemical and/or co-contaminant competition can significantly impede adsorption based PFAS removal. These challenges may be addressed using engineered filtration, such as reverse osmosis or nanofiltration (RO/NF); however, for larger flow systems RO/NF may have unacceptable reject ratios as high as 35% and the capital cost may preclude these technologies. Extending these technologies to natural waters, which have various degrees of geochemical and co-contaminant competition, often requires a treatment train, combining conventional adsorbents or engineered filtration with pretreatment and more innovative and emerging remediation solutions for PFAS. Conventional and Next Generation water treatment technologies for PFAS generally employ one of three mechanisms (adsorption, separation, or destruction). These mechanisms include many types of technologies for both municipal drinking water and extracted natural water applications. The previously mentioned AC, AIX, and RO/NF are commercially available technologies that are actively being deployed for PFAS treatment. Research and development around these technologies is focused on optimization, and ultimate destruction of PFAS is achieved through incineration. Next Generation water treatment technologies include PFAS-specific flocculants, foam fractionation, novel AIX resins, new engineered adsorptive media, electrochemical treatment, sonolysis, and photolysis, radiation, and plasma (forms of advanced reductive processes [ARP]). Research and development around these technologies is focused on proof of concept and assimilation to real world applications. As the PFAS-relevant destructive technologies (such as incineration, electrochemical treatment, sonolysis, and ARP) are energy intensive, the state of the practice for PFAS water treatment is to focus adsorption/separation based technologies on reducing and concentrating the volume of water requiring destructive treatment. This enables more flexibility with respect to circulation frequency, residence time, and more control over energy usage. Water treatment for PFAS presently requires multiple technologies (i.e. a treatment train) to protect human health in a cost-conscious manner. An investment in research and development to explore new technologies is part of a key initiative for efficient protection of human health. This presentation attempts to review PFAS-relevant water treatment technologies and provide perspective as to their status with respect to applicability and commercial relevance. (authors)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Novel Approach to PV Inverter Modeling and Simulation Leveraging Experiments, Learning Based Modeling and Co-Simulation: Preprint

Photovoltaic inverter (PV) inverter manufacturers use custom, proprietary control approaches and topologies in their inverter design. Due to this proprietary nature, it is not possible to share EMT domain models for system studies. This research work presents a novel approach in experimental design, high fidelity data collection, use of learning-based modeling, and co-simulation to enhance the PV inverter modeling. We used a 20 kW off-the-shelf grid following PV inverter and subjected the inverter to controlled tests including voltage and frequency step changes, as well as solar irradiance variations. The recorded high frequency data was used in learning-based model training. This learning-based model was imported into an Electromagnetic Transient (EMT) simulation tool using co-simulation techniques to complete the modeling effort and integrate the model into an EMT simulation tool. The three key components in this research work are the design of experimental setup, use of learning-based approach for model development and use of co-simulation to complete the approach. The proposed approach will allow users to develop a model in a really short period of time and achieve reasonable inverter models.

artificial intelligence↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states.For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management system↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The electrical asymmetry effect in geometrically asymmetric capacitive radio frequency plasmas

The electrical asymmetry effect (EAE) allows an almost ideal separate control of the mean ion energy, , and flux, {Gamma}{sub i}, at the electrodes in capacitive radio frequency discharges with identical electrode areas driven at two consecutive harmonics with adjustable phase shift, {theta}. In such geometrically symmetric discharges, a DC self bias is generated as a function of {theta}. Consequently, can be controlled separately from {Gamma}{sub i} by adjusting the phase shift. Here, we systematically study the EAE in low pressure dual-frequency discharges with different electrode areas operated in argon at 13.56 MHz and 27.12 MHz by experiments, kinetic simulations, and analytical modeling. We find that the functional dependence of the DC self bias on {theta} is similar, but its absolute value is strongly affected by the electrode area ratio. Consequently, the ion energy distributions change and can be controlled by adjusting {theta}, but its control range is different at both electrodes and determined by the area ratio. Under distinct conditions, the geometric asymmetry can be compensated electrically. In contrast to geometrically symmetric discharges, we find the ratio of the maximum sheath voltages to remain constant as a function of {theta} at low pressures and {Gamma}{sub i} to depend on {theta} at the smaller electrode. These observations are understood by the model. Finally, we study the self-excitation of non-linear plasma series resonance oscillations and its effect on the electron heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Z Z free entangling gates for superconducting qubits assisted by a driven resonator

Engineering high-fidelity two-qubit gates is an indispensable step toward practical quantum computing. For superconducting quantum platforms, one important setback is the stray interaction between qubits, which causes significant coherent errors. For transmon qubits, protocols for mitigating such errors usually involve fine-tuning the hardware parameters or introducing usually noisy flux-tunable couplers. In this work, we propose a simple scheme to cancel these stray interactions. The coupler used for such cancelation is a driven high-coherence resonator, where the amplitude and frequency of the drive serve as control knobs. Through the resonator-induced-phase interaction, the static Z Z coupling can be entirely neutralized. We numerically show that such a scheme can enable short and high-fidelity entangling gates, including cross-resonance controlled-not (cnot) gates within 40 ns and adiabatic controlled- Z gates within 140 ns. Our architecture is not only Z Z -free, but also contains no extra noisy components, such that it preserves the coherence times of fixed-frequency transmon qubits. With the state-of-the-art coherence times, the error of our cross-resonance cnot gate can be reduced to below 10 − 4 .

Huang, Ziwen↗

LCLS-II Cryomodule and Cryogenic Distribution Control

LCLS-II is a superconducting upgrade to the existing Linear Coherent Light Source at the SLAC National Accelerator Laboratory. Construction is underway with a planned continuous wave beam rate of up to 1 MHz. Two cryogenic plants provide helium to a distribution system, and 37 cryomodules with superconducting cavities will operate with Liquid helium at 2.2K. The cryomodules and distribution system is controlled with networked PLC's and EPICS as an integrated system that work in concert for controlling valves, pressure, flow, and temperature. Interlocks and critical process information is communicated with the Low Level Radio Frequency, vacuum, and magnet systems. Engaging the controls community proved vital in advancing the controls architecture from a conventional design to a centralized, reliable, and cost-effective distributed platform.

43 PARTICLE ACCELERATORS↗

Submodule Capacitor Reduction for a 1 MVA SiC-Based Modular Multilevel Converter Motor Drive using High Frequency Common-Mode Voltage Injection

This paper describes a strategy to reduce the size of submodule capacitors of a 1 MVA, 0-1 kHz, 7-level modular multilevel converter (MMC) based medium voltage variable speed drive (MVVSD) using 1.7 kV SiC MOSFETs. Hardware designs of submodules to withstand high dv/dt and capacitor selection based on common mode voltage injection have been presented in literature. The issue with injection is the error in tracking of injected circulation current which results in fundamental frequency fluctuations in the submodule capacitor voltage. This paper presents a strategy for higher frequency sinusoidal common mode voltage based on more accurate tracking of the circulating current; realized through an improved control strategy combined with a higher switching frequency. Using the methods presented in this paper, a smaller submodule capacitance and reduced output current THD of the motor drive is achieved. A loss analysis model is proposed to evaluate the effect of the proposed strategy on the MMC efficiency. This helps balance the reduction in the capacitor against the increase in the losses as a result of increased switching frequency. Simulations and a down-scaled experimental setup are used to demonstrate this concept.

Potty, Karun↗

Periodicity in bimodal atomic force microscopy

Periodicity is fundamental for quantification and the application of conservation principles of many important systems. Here, we discuss periodicity in the context of bimodal atomic force microscopy (AFM). The relationship between the excited frequencies is shown to affect and control both experimental observables and the main expressions quantified via these observables, i.e., virial and energy transfer expressions, which form the basis of the bimodal AFM theory. The presence of a fundamental frequency further simplifies the theory and leads to close form solutions. Predictions are verified via numerical integration of the equation of motion and experimentally on a mica surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent hybrid electromagnetic field imaging

An apparatus and corresponding method for coherent hybrid electromagnetic field imaging of a target, where an energy source is used to generate a propagating electromagnetic beam, an electromagnetic beam splitting means to split the beam into two or more coherently matched beams of about equal amplitude, and where the spatial and temporal self-coherence between each two or more coherently matched beams is preserved. Two or more differential modulation means are employed to modulate each two or more coherently matched beams with a time-varying polarization, frequency, phase, and amplitude signal. An electromagnetic beam combining means is used to coherently combine said two or more coherently matched beams into a coherent electromagnetic beam. One or more electromagnetic beam controlling means are used for collimating, guiding, or focusing the coherent electromagnetic beam. One or more apertures are used for transmitting and receiving the coherent electromagnetic beam to and from the target. A receiver is used that is capable of square-law detection of the coherent electromagnetic beam. A waveform generator is used that is capable of generation and control of time-varying polarization, frequency, phase, or amplitude modulation waveforms and sequences. A means of synchronizing time varying waveform is used between the energy source and the receiver. Finally, a means of displaying the images created by the interaction of the coherent electromagnetic beam with target is employed.

47 OTHER INSTRUMENTATION↗

Potential of electric quadrupole transitions in radium isotopes for single-ion optical frequency standards

We explore the potential of the electric quadrupole transitions 7s {sup 2}S{sub 1/2}-6d {sup 2}D{sub 3/2}, 6d {sup 2}D{sub 5/2} in radium isotopes as single-ion optical frequency standards. The frequency shifts of the clock transitions due to external fields and the corresponding uncertainties are calculated. Several competitive {sup A}Ra{sup +} candidates, with A= 223-229, are identified. In particular, we show that the transition 7s {sup 2}S{sub 1/2} (F=2,m{sub F}=0)-6d {sup 2}D{sub 3/2} (F=0,m{sub F}=0) at 828 nm in {sup 223}Ra{sup +}, with no linear Zeeman and electric quadrupole shifts, stands out as a relatively simple case, which could be exploited as a compact, robust, and low-cost atomic clock operating at a fractional frequency uncertainty of 10{sup -17}. With more experimental effort, the {sup 223,225,226}Ra{sup +} clocks could be pushed to a projected performance reaching the 10{sup -18} level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving Small Signal Stability through Operating Point Adjustment

ModeMeter techniques for real-time small signal stability monitoring continue to mature, and more and more phasor measurements are available in power systems. It has come to the stage to bring modal information into real-time power system operation. This paper proposes to establish a procedure for Modal Analysis for Grid Operations (MANGO). Complementary to PSS’s and other traditional modulation-based control, MANGO aims to provide suggestions such as increasing generation or decreasing load for operators to mitigate low-frequency oscillations. Different from modulation-based control, the MANGO procedure proactively maintains adequate damping for all time, instead of reacting to disturbances when they occur. Effect of operating points on small signal stability is presented in this paper. Implementation with existing operating procedures is discussed. Several approaches for modal sensitivity estimation are investigated to associate modal damping and operating parameters. The effectiveness of the MANGO procedure is confirmed through simulation studies of several test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗