Search NASA⌕ Search

SEARCH · Search NASA

Results for “input estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A Rapid Decision Support Tool for Estimating Impacts of a Vadose Zone Volatile Organic Compound Source on Groundwater and Soil Gas

Diminishing rates of subsurface volatile contaminant removal by soil vapor extraction (SVE) oftentimes warrants an in‐depth performance assessment to guide remedy decision‐making processes. Such a performance assessment must include quantitative approaches to better understand the impact of remaining vadose zone contamination on soil gas and groundwater concentrations. The spreadsheet‐based Soil Vapor Extraction Endstate Tool (SVEET) software functionality has recently been expanded to facilitate quantitative performance assessments. The updated version, referred to as SVEET2, includes expansion of the input parameter ranges for describing a site (site geometry, source characteristics, etc.), an expanded list of contaminants, and incorporation of elements of the Vapor Intrusion Estimation Tool for Unsaturated‐zone Sources software to provide soil gas concentration estimates for use in vapor intrusion evaluation. As part of the update, SVEET2 was used to estimate the impact of a tetrachloroethene (PCE) vadose zone source on groundwater concentrations, comparing SVEET2 results to field‐observed values at an undisclosed site where SVE was recently terminated. PCE concentrations from three separate monitoring wells were estimated by SVEET2 to be within the range of 6.0–6.7 μg/L, as compared to actual field concentrations that ranged from 3 to 11 μg/L PCE. These data demonstrate that SVEET2 can rapidly provide representative quantitative estimates of impacts from a vadose zone contaminant source at field sites. Finally, in the context of the SVE performance assessment, such quantitative estimates provide a basis to support remedial and/or regulatory decisions regarding the continued need for vadose zone volatile organic compound remediation or technical justification for SVE termination, which can significantly reduce the cost to complete for a site.

54 ENVIRONMENTAL SCIENCES↗

A Bayesian Approach to the Eagar–Tsai Model for Melt Pool Geometry Prediction with Implications in Additive Manufacturing of Metals

Here, this paper focuses on improving the melt pool geometry predictions and quantifying uncertainties using an adapted version of the Eagar–Tsai (E–T) model that incorporates temperature-dependent properties of the material as well as powder conditions. Additionally, Bayesian inference is employed to predict distributions for the E–T model input parameters of laser absorptivity and powder bed porosity by incorporating experimental results into the analysis. Monte Carlo uncertainty propagation is then used with these parameter distributions to estimate the melt pool depth and associated uncertainty. Our results for the 316L stainless steel suggest that both the absorptivity and powder bed porosity are strongly influenced by the laser power. In contrast, the scanning speed has only a marginal effect on both the absorptivity and powder bed porosity. We constructed a printability map using the Bayesian E–T model based on power-dependent input parameter values to demonstrate the merit of the approach. The Bayesian approach improved the accuracy in predicting the keyhole regions in the laser power-scan speed parameter space for the 316L stainless steel. Although applied to a specific adaptation of the E–T model, the method put forth can be extended to quantify uncertainties in other numerical models as well as in the estimation of unknown parameters.

316L Stainless Steel (SS).↗

Simulation Evaluation of a Large-Scale Implementation of Virtual-Phase Link-Based Model Predictive Control

Traffic congestion is a serious problem in the US, and traffic signal control is one of the effective solutions to congestion. Previous research on model predictive control (MPC)-based traffic signal control showed substantial benefits over conventional methods. This study focused on implementing MPC over a large-scale network with complex intersections and the impact of cycle length, network size, and imperfect state estimation on performances. This study implemented a virtual phase link (VPL)-based model predictive control method which used the number of vehicles in each VPL as input state variables and was suitable for National Electrical Manufacturing Association (NEMA) ring-barrier control. To test the impact of network size, the performance of distributed MPC (36 intersections in the network are divided into five subnetworks) was compared with that of MPC over the full network for a set of cycle lengths. To test the impact of imperfect state estimation, we synthetically infused estimation error and developed two scenarios, MPC-error and MPC-error narrow, which had higher and lower estimation errors, respectively. The performance of these MPC methods was compared with that of the existing time-of-day (TOD) method and an offline method that used Webster's method for split and MULTIBAND for cycle length and offset optimization. Trajectory and linkwise signal performance measures were collected from the simulation to evaluate performance. The distributed MPC method with perfect state estimation had the lowest delay and highest energy efficiency of all the methods. The performance of MPC decreased as the prediction inaccuracy increased. MPC-error had 7% and 11% more delay than MPC-error narrow in the morning and evening peaks, respectively. Overall, simulation results suggest that even with imperfect state estimation, MPC methods will outperform offline methods significantly.

large-scale simulation↗

WE-AB-204-08: Uncertainties in Kinetic Modeling of Shortened Dynamic 18F-FMISO PET Due to Image Noise

Purpose: To assess uncertainties in voxel-wise kinetic modeling (KM) of dynamic 18F-FMISO PET (dPET) due to image noise for different lengths of dPET acquisitions. Methods: 12 tumor time activity curves (TACs) deduced from 6 head and neck cancer patient dPET datasets (45min dPET + 10min frames at ∼95min and ∼160min respectively) were modeled using an irreversible two-tissue compartment model to estimate kinetic rate constants (KRCs) k3, vB, K1, and K1/k2 (reference standard). For each modeled TAC, 1000 noisy TACs were simulated by adding Gaussian noise with standard deviation equivalent to that observed on a voxel level in GE DSTE PET-CT. KM was conducted for each set of noisy TACs using (i) full dataset (170min), and repeated using (ii) 105min and (iii) 45min shortened subsets, with an input function that was image-derived from the dPET dataset of matching length. Absolute value of percent difference between KRCs from noisy TACs as estimated from either of 3 datasets and reference standard KRCs was used to represent bias. Results: For all KRCs, bias was higher for shortened datasets. For k3, bias was lower when actual k3 was higher: from 7%±5% (170min), 9%±7% (105min), and 14%±11% (45min) (actual k3=0.0098), to 32%±25% (170min), 45%±34% (95min), and 79%±48% (45min) (actual k3=0.0008). Similar relationship was observed for vB, with bias being between ∼7% (actual vB=0.28) and ∼26–34% (actual vB=0.08). For K1 [K1/k2], bias was ∼6–10% [∼2–3%] (dependence on actual value of K1 [K1/k2] was not observed). Conclusion: Uncertainties in voxel-wise KM of shortened 18F-FMISO dPET due to image noisy only are larger for shorter acquisitions and, for k3 [vB], the bias was found to be inversely correlated with the actual values of k3 [vB]. Using 45min subset, k3, vB, K1, and K1/k2 could be estimated to within ∼15–80%, ∼10–35%, ∼10%, and ∼3%, respectively.

60 APPLIED LIFE SCIENCES↗

Preliminary results concerning the simulation of beam profiles from extracted ion current distributions for mini-STRIKE

The Radio Frequency (RF) negative hydrogen ion source prototype has been chosen for the ITER neutral beam injectors due to its optimal performances and easier maintenance demonstrated at Max-Planck-Institut für Plasmaphysik, Garching in hydrogen and deuterium. One of the key information to better understand the operating behavior of the RF ion sources is the extracted negative ion current density distribution. This distribution—influenced by several factors like source geometry, particle drifts inside the source, cesium distribution, and layout of cesium ovens—is not straightforward to be evaluated. The main outcome of the present contribution is the development of a minimization method to estimate the extracted current distribution using the footprint of the beam recorded with mini-STRIKE (Short-Time Retractable Instrumented Kalorimeter). To accomplish this, a series of four computational models have been set up, where the output of a model is the input of the following one. These models compute the optics of the ion beam, evaluate the distribution of the heat deposited on the mini-STRIKE diagnostic calorimeter, and finally give an estimate of the temperature distribution on the back of mini-STRIKE. Several iterations with different extracted current profiles are necessary to give an estimate of the profile most compatible with the experimental data. A first test of the application of the method to the BAvarian Test Machine for Negative ions beam is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Estimation of the DARHT Radiographic Spot Size from Spatially Modulated Images

We wrote a software routine to find local extrema and calculate the contrast in the image for each feature set. The input is a KTO image in the standard DARHT orientation, pre-processed by flat-fielding, dark frame subtraction and de-warping. Table 1 shows contrast results for five contemporaneous DARHT images of the KTO. For some very dense feature sets, contrast measurements are not possible due to a lack of local extrema, and in this case no contrast value is given in the table. Highlighted in bold are the contrast values for each image that bound the threshold C = 0.01. The contrast is varying rapidly enough with spatial frequency that we can interpolate between these values to find an estimate of the spatial frequency at the threshold value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Potential for Hydropower Capacity at Non-powered Dams

In the last decade, retrofits of existing nonpowered dams (NPDs) have made up the largest share of capacity increases for US hydropower. Accurate estimates of potential capacity and generation at NPDs help identify sites that may be worth investing in detailed feasibility analyses and design exploration. This dataset contains estimates of technical potential capacity and generation at 2,616 NPDs in the conterminous US. This is based on a subset of dams that were found by earlier resource assessments to have at least 100kW of theoretical potential. Historical daily streamflow (modeled or from USGS gauge records) and hydraulic head (based on historical observations or primary purpose and dam height) are the main inputs to the HydroGenerate model, which determines design flow, turbine efficiencies, and assumed friction losses and then calculates nominal capacity, daily generation, and capacity factor. These estimates represent the conditions over the historical period of 1980-2015, and are summarized on a monthly basis (i.e., averaged for each month of the year) and overall (i.e., nominal capacity, average annual generation (MWh), and average annual capacity factor). A total of nearly 4 GW capacity is estimated across all 2,616 NPDs included in the dataset.

Hansen, Carly [Oak Ridge National Laboratory (ORNL↗

New simplified formulae of estimation the total number of fissions based on the Nordheim-Fuchs model - 14297

This article presents simplified formulae for the estimation of the total number of fissions for criticality accidents. One of these formulae is based on the Nordheim-Fuchs model. An additional formula takes into account the boiling for solution systems. These formulae are adapted to homogeneous media and can be used for solution and metal accidents. The principle of these formulae, associated with their assumptions, is described. Then, these formulae are compared with practical applications for SILENE and CRAC reactors (solution systems) and past criticality accidents with metal assemblies as well as a previous simplified formula. The proposed new formulae give bounding estimates of the total number of fissions, provided that their area of applicability are respected and that the simulations performed to calculate the necessary input data are representative of the criticality accident configuration. These new formulae require the determination of more parameters than previous simplified formulae, which make them more complicated to use, but may point out and quantify the impact of some physical phenomenon (for instance for the solution boiling). In particular, the comparison with past criticality accidents with metal assemblies shows that more detailed simulations (in terms of geometry and reflection conditions) might be performed in future work to improve the estimate of the number of fissions based on the Nordheim-Fuchs model. (authors)

42 ENGINEERING↗

Review of Literature for Inputs to the National Water Savings Model and Spreadsheet Tool-Commercial/Institutional

Lawrence Berkeley National Laboratory (LBNL) is developing a computer model and spreadsheet tool for the United States Environmental Protection Agency (EPA) to help estimate the water savings attributable to their WaterSense program. WaterSense has developed a labeling program for three types of plumbing fixtures commonly used in commercial and institutional settings: flushometer valve toilets, urinals, and pre-rinse spray valves. This National Water Savings-Commercial/Institutional (NWS-CI) model is patterned after the National Water Savings-Residential model, which was completed in 2008. Calculating the quantity of water and money saved through the WaterSense labeling program requires three primary inputs: (1) the quantity of a given product in use; (2) the frequency with which units of the product are replaced or are installed in new construction; and (3) the number of times or the duration the product is used in various settings. To obtain the information required for developing the NWS-CI model, LBNL reviewed various resources pertaining to the three WaterSense-labeled commercial/institutional products. The data gathered ranged from the number of commercial buildings in the United States to numbers of employees in various sectors of the economy and plumbing codes for commercial buildings. This document summarizes information obtained about the three products' attributes, quantities, and use in commercial and institutional settings that is needed to estimate how much water EPA's WaterSense program saves.

99 GENERAL AND MISCELLANEOUS↗

Financial Analysis of Incentive Mechanisms to Promote Energy Efficiency: Case Study of a Prototypical Southwest Utility

Many state regulatory commissions and policymakers want utilities to aggressively pursue energy efficiency as a strategy to mitigate demand and energy growth, diversify the resource mix, and provide an alternative to building new, costly generation. However, as the National Action Plan for Energy Efficiency (NAPEE 2007) points out, many utilities continue to shy away from aggressively expanding their energy efficiency efforts when their shareholder's fundamental financial interests are placed at risk by doing so. Thus, there is increased interest in developing effective ratemaking and policy approaches that address utility disincentives to pursue energy efficiency or lack of incentives for more aggressive energy efficiency efforts. New regulatory initiatives to promote increased utility energy efficiency efforts also affect the interests of consumers. Ratepayers and their advocates are concerned with issues of fairness, impacts on rates, and total consumer costs. From the perspective of energy efficiency advocates, the quid pro quo for utility shareholder incentives is the obligation to acquire all, or nearly all, achievable cost-effective energy efficiency. A key issue for state regulators and policymakers is how to maximize the cost-effective energy efficiency savings attained while achieving an equitable sharing of benefits, costs and risks among the various stakeholders. In this study, we modeled a prototypical vertically-integrated electric investor-owned utility in the southwestern US that is considering implementing several energy efficiency portfolios. We analyze the impact of these energy efficiency portfolios on utility shareholders and ratepayers as well as the incremental effect on each party when lost fixed cost recovery and/or utility shareholder incentive mechanisms are implemented. A primary goal of our quantitative modeling is to provide regulators and policymakers with an analytic framework and tools that assess the financial impacts of alternative incentive approaches on utility shareholders and customers if energy efficiency is implemented under various utility operating, cost, and supply conditions.We used and adapted a spreadsheet-based financial model (the Benefits Calculator) which was developed originally as a tool to support the National Action Plan for Energy Efficiency (NAPEE). The major steps in our analysis are displayed graphically in Figure ES- 1. Two main inputs are required: (1) characterization of the utility which includes its initial financial and physical market position, a forecast of the utility?s future sales, peak demand, and resource strategy to meet projected growth; and (2) characterization of the Demand-Side Resource (DSR) portfolio ? projected electricity and demand savings, costs and economic lifetime of a portfolio of energy efficiency (and/or demand response) programs that the utility is planning or considering implementing during the analysis period. The Benefits Calculator also estimates total resource costs and benefits of the DSR portfolio using a forecast of avoided capacity and energy costs. The Benefits Calculator then uses inputs provided in the Utility Characterization to produce a ?business-as usual? base case as well as alternative scenarios that include energy efficiency resources, including the corresponding utility financial budgets required in each case. If a decoupling and/or a shareholder incentive mechanism are instituted, the Benefits Calculator model readjusts the utility?s revenue requirement and retail rates accordingly. Finally, for each scenario, the Benefits Calculator produces several metrics that provides insights on how energy efficiency resources, decoupling and/or a shareholder incentive mechanism impacts utility shareholders (e.g. overall earnings, return on equity), ratepayers (e.g., average customer bills and rates) and society (e.g. net resource benefits).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Uncertainty Quantification of Global Net Methane Emissions From Terrestrial Ecosystems Using a Mechanistically Based Biogeochemistry Model

Quantification of methane (CH4) emissions from wetlands and its sinks from uplands is still fraught with large uncertainties. Here, a methane biogeochemistry model was revised, parameterized, and verified for various wetland ecosystems across the globe. The model was then extrapolated to the global scale to quantify the uncertainty induced from four different types of uncertainty sources including parameterization, wetland type distribution, wetland area distribution, and meteorological input. We found that global wetland emissions are 212 ± 62 and 212 ± 32 Tg CH4 year -1 (1Tg = 10 12 g) due to uncertain parameters and wetland type distribution, respectively, during 2000–2012. Using two wetland distribution data sets and three sets of climate data, the model simulations indicated that the global wetland emissions range from 186 to 212 CH 4 year -1 for the same period. The parameters were the most significant uncertainty source. After combining the global methane consumption in the range of -34 to -46 Tg CH 4 year -1 , we estimated that the global net land methane emissions are 149–176 Tg CH 4 year -1 due to uncertain wetland distribution and meteorological input. Spatially, the northeast United States and Amazon were two hotspots of methane emission, while consumption hotspots were in the Eastern United States and eastern China. During 1950–2016, both wetland emissions and upland consumption increased during El Niño events and decreased during La Niña events. This study highlights the need for more in situ methane flux data, more accurate wetland type, and area distribution information to better constrain the model uncertainty.

58 GEOSCIENCES↗

Laboratory studies on surface sampling of Bacillus anthracis contamination: summary, gaps, and recommendations

This article summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the 1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and 2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed. Recommendations are given for future evaluations of data from existing studies and possible new studies.

anthrax↗

Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

59 BASIC BIOLOGICAL SCIENCES↗

ACCURATE CHARACTERIZATION OF HIGH-DEGREE MODES USING MDI OBSERVATIONS

We present the first accurate characterization of high-degree modes, derived using the best Michelson Doppler Imager (MDI) full-disk full-resolution data set available. A 90 day long time series of full-disk 2 arcsec pixel{sup -1} resolution Dopplergrams was acquired in 2001, thanks to the high rate telemetry provided by the Deep Space Network. These Dopplergrams were spatially decomposed using our best estimate of the image scale and the known components of MDI's image distortion. A multi-taper power spectrum estimator was used to generate power spectra for all degrees and all azimuthal orders, up to l = 1000. We used a large number of tapers to reduce the realization noise, since at high degrees the individual modes blend into ridges and thus there is no reason to preserve a high spectral resolution. These power spectra were fitted for all degrees and all azimuthal orders, between l = 100 and l = 1000, and for all the orders with substantial amplitude. This fitting generated in excess of 5.2 Multiplication-Sign 10{sup 6} individual estimates of ridge frequencies, line widths, amplitudes, and asymmetries (singlets), corresponding to some 5700 multiplets (l, n). Fitting at high degrees generates ridge characteristics, characteristics that do not correspond to the underlying mode characteristics. We used a sophisticated forward modeling to recover the best possible estimate of the underlying mode characteristics (mode frequencies, as well as line widths, amplitudes, and asymmetries). We describe in detail this modeling and its validation. The modeling has been extensively reviewed and refined, by including an iterative process to improve its input parameters to better match the observations. Also, the contribution of the leakage matrix on the accuracy of the procedure has been carefully assessed. We present the derived set of corrected mode characteristics, which includes not only frequencies, but line widths, asymmetries, and amplitudes. We present and discuss their uncertainties and the precision of the ridge-to-mode correction schemes, through a detailed assessment of the sensitivity of the model to its input set. The precision of the ridge-to-mode correction is indicative of any possible residual systematic biases in the inferred mode characteristics. In our conclusions, we address how to further improve these estimates, and the implications for other data sets, like GONG+ and HMI.

79 ASTRONOMY AND ASTROPHYSICS↗

Radionuclide Inventory and Decay Heat Quantification Methodology for Severe Accident Simulations.

The MELCOR and MACCS computer codes require inputs for radionuclide inventory and decay heat in order to simulate severe accident phenomenology, source term, and consequences. Therefore, Sandia National Laboratories ( SNL ) has developed accurate and automated methods using SCALE 6 in conjunction with automation scripts to directly generate MELCOR and MACCS input records for radionuclide inventories and decay heating. Consistent information between the two codes is essential for realistic modeling of severe nuclear accidents it is the radionuclide inventory and decay power that are the principal safety problems of any severe accident that assumes successful reactor shutdown. SNL plans to conduct best-estimate calculations and uncertainty analyses using MELCOR and MACCS for several reactors, including units 1 - 3 of Fukushima Daiichi, which entail accurate and technically-scrutable information for the input models. The SNL methodology for generating radionuclide and decay power inputs directly from SCALE6 calculations is mostly presented in the context of supporting Fukushima modeling efforts. Furthermore, certain historical assumptions used by MELCOR and MACCS in the abstraction of radionuclide classes and their properties are reviewed, and these assumptions are compared to modern code predictions by SCALE6.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Technique for Estimating Liquid Droplet Diameter and Liquid Water Content in Stratocumulus Clouds Using Radar and Lidar Measurements

This paper describes a technique for estimating the liquid water content (LWC) and a characteristic particle diameter in stratocumulus clouds using radar and lidar observations. The uncertainty in LWC estimate from radar and lidar measurements is significantly reduced once the characteristic particle diameter is known. The technique is independent of the drop size distribution. It is applicable for a broad range of W-band reflectivity Z between -30 and 0 dBZ and all values of lidar backscatter β observations. No partitioning of cloud or drizzle is required on the basis of an arbitrary threshold of Z as in prior studies. A method for estimating droplet diameter and LWC was derived from the electromagnetic simulations of radar and lidar observations. In situ stratocumulus cloud and drizzle probe spectra were input to the electromagnetic simulation. The retrieved droplet diameter and LWC were validated using in situ measurements from the southeastern Pacific Ocean. The retrieval method was applied to radar and lidar measurements from the northeastern Pacific. Uncertainty in the retrieved droplet diameter and LWC that are due to the measurement errors in radar and lidar backscatter measurements are 7% and 14%, respectively. The retrieved LWC was validated using the concurrent G-band radiometer estimates of the liquid water path.

54 ENVIRONMENTAL SCIENCES↗

Desalinating a Real Hyper-Saline Pre-Treated Produced Water via Direct-Heat Vacuum Membrane Distillation

Membrane distillation (MD) is an emerging thermal desalination technology capable of desalinating waters of any salinity. During typical MD processes, the saline feedwater is heated and acts as the thermal energy carrier; however, temperature polarization (as well as thermal energy loss) contributes to low distillate fluxes, low single-pass water recovery and poor thermal efficiency. An alternative approach is to integrate an extra thermal energy carrier as part of the membrane and/or module assembly, which can channel externally provided heat directly to the membrane-feedwater interface and/or along the feed channel length. This direct-heat delivery has been demonstrated to increase single-pass water recovery and enhance the overall thermal efficiency. We developed a bench-scale direct-heated vacuum MD (DHVMD) process to desalinate pre-treated oil and gas "produced water" with an initial total dissolved solids of 115,500 ppm at a feed temperature ranging between 24 and 32 degrees C. We evaluated both water flux and specific energy consumption (SEC) as a function of water recovery. The system achieved a 50% water recovery without significant scaling, with an average flux >6 kg m-2 hr-1 and a SEC as low as 2,530 kJ kg-1. The major species of mineral scales (i.e., NaCl, CaSO4, and SrSO4) that limited the water recovery to 68% were modeled in terms of thermodynamics and identified by scanning electron microscopy and energy-dispersive X-ray spectroscopy. In addition, we further developed and employed a physics-based process model to estimate temperature, salinity, water transport and energy flows for full-scale vacuum MD and DHVMD modules. Model results show that a direct-heat input rate of 3,600 W can increase single-pass water recovery from 2.1% to 3.1% while lowering the thermal SEC from 7,800 kJ kg-1 to 6,517 kJ kg-1 in an unoptimized module. Finally, the scaling up potential of DHVMD process is briefly discussed.

brine↗

Towards a prediction of fission cross sections on the basis of microscopic nuclear inputs

Recently, a sound description of some of the basic nuclear ingredients required in the calculation of fission cross sections has been obtained. These concern in particular fission barriers within the Hartree-Fock-Bogoliubov (HFB) method and nuclear level densities at the fission saddle points within the combinatorial model. Both ingredients are determined coherently, the nuclear level densities being estimated on the basis of the single-particle scheme and pairing strength of the same mean field model that was used to determine the fission saddle points. The aim of the present study is to evaluate the quality of such inputs in the calculation of fission cross sections. Although the barrier height can still not be predicted with an accuracy better than about 700 keV, the use of the full HFB fission path and the corresponding WKB calculation of the probability to penetrate the fission barrier clearly provides a better way to estimate fission cross section in comparison with highly parametrized phenomenological models, when no experimental data is available. It is shown that a satisfactory estimate of the fission cross section for nonenergy applications can be achieved with a global renormalization of the barrier height and the microscopic nuclear level densities at the fission saddle points. Good agreement with experimental data can be obtained if both the fission barrier heights and level densities are independently renormalized. The resulting barrier heights required to reproduce experimental cross sections are found to be smaller by a few hundred keV with respect to previous analyses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗