Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnected systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Queued Up: 2024 Edition, Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2023 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require projects seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. The amount of new electric capacity in these queues is growing dramatically, with nearly 2,600 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 95% of which is for zero-carbon resources like solar, wind, and battery storage). However, most projects that apply for interconnection are ultimately withdrawn, and those that are built are taking longer on average to complete the required studies and become operational. Data from these queues nonetheless provide a general indicator for mid-term trends in developer interest.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queued Up: 2026 Edition, Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2025 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with https://www.interconnection.fyi. Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 50 non-ISO balancing areas), which collectively represent ~98% of currently installed U.S. electric generating capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview of the Space Station communications networks

Within the Space Station Freedom program, the communications and data-processing capabilities that will be used to handle the operational and scientific information needs will be provided by a Space Station information and communications system. This system will be composed of a variety of elements, networks, and subnetworks. The networks and how they are interconnected are described. The discussion covers communications system elements and services, elements of the onboard systems, wide-area transport network elements, and command and control elements.

Smith, Joseph F.↗

Design and characterization of ultra-stretchable monolithic silicon fabric

Stretchable electronic systems can play instrumental role for reconfigurable macro-electronics such as distributed sensor networks for wearable and bio-integrated electronics. Typically, polymer composite based materials and its deterministic design as interconnects are used to achieve such systems. Nonetheless, non-polymeric inorganic silicon is the predominant material for 90% of electronics. Therefore, we report the design and fabrication of an all silicon based network of hexagonal islands connected through spiral springs to form an ultra-stretchable arrangement for complete compliance to highly asymmetric shapes. Several design parameters are considered and their validation is carried out through finite element analysis. The fabrication process is based on conventional microfabrication techniques and the measured stretchability is more than 1000% for single spirals and area expansions as high as 30 folds in arrays. The reported method can provide ultra-stretchable and adaptable electronic systems for distributed network of high-performance macro-electronics especially useful for wearable electronics and bio-integrated devices.

36 MATERIALS SCIENCE↗

V2XConnect: Harmonizing the Landscape of Bidirectional Charging Codes, Standards, and Communication Protocols

The utility grid is constantly evolving with new generation sources and diverse loads from backup generators, backup batteries, rooftop photovoltaics (PV), and flexible charging loads. Each of these technologies presents consumers with an opportunity to work with their local utility to promote grid stability, reliability, and affordability. Through a wide range of programs, utilities are incentivizing the use of these resources to benefit the grid. However, especially for devices with inverters that supply power back to the grid, it is important that these assets comply with local grid codes to ensure human safety, power quality, and grid reliability. One of the most promising of these new technologies is the bidirectional electric vehicle (EV) coupled with bidirectional electric vehicle supply equipment (EVSE). This report introduces the technologies that enable bidirectional charging and how these systems operate. It then outlines the necessary interconnection codes and industry standards that govern the operations of grid-tied inverters, including those in bidirectional charging. A key challenge is then outlined from the complex landscape of communication protocols and proprietary systems designed to coordinate these grid assets. Finally, a single gateway solution is proposed to harmonize communications between all assets across an entire site for a cohesive response to grid codes and utility programs that is flexible enough to support a range of market options.

33 ADVANCED PROPULSION SYSTEMS↗

Review of the Recent Frequency Performance of the Eastern, Western and ERCOT Interconnections

The reliable operation of an electric power system depends on careful management of the balance between generation and load to ensure that system frequency is maintained within narrow bounds around a scheduled value. Yet, maintaining frequency at the scheduled value is challenging because the load served is continuously changing, and occasionally, events such as the sudden loss of a large generation plant or large amount of load, cause frequency to deviate abruptly. This report reviews the recent history of frequency performance for all three U.S. interconnections: Eastern, Western, and the Electric Reliability Council of Texas (ERCOT). The review is based on data collected by the North American Electric Reliability Corporation (NERC). The review focuses on frequency response, which measures the performance of the interconnections immediately following sudden, large imbalances between load and generation. Trends in frequency response are presented and preliminary efforts are made to relate frequency response to other aspects of frequency performance and to examine aspects of the methods used to calculate frequency response.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part II: Long Term Faults

Here, this paper addresses the transient stability (also called large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability, and frequency response for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted system' components present and is applicable to the study of both short term and long term faults. Part I of this research discussed the short term faults whereas as Part II, the present paper, discusses long term faults. This research considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000 MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part I: Short Term Faults

Power system planning is the process of forecasting load demand and ensuring sufficient generation and reserve capacities over some planning horizon. This process includes investigation of steady-state and dynamic operation of power system of interest. This paper addresses the transient stability (also known as large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability and frequency response for all fault types for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted components present and is applicable to the study of both short term and long term faults, though only short term faults are considered here (long term faults are treated sequentially in a companion paper). Furthermore, this paper considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Description of the Space Shuttle Reaction Control System

The Space Shuttle RCS (reaction control system) is required to provide propulsion thrust for precise attitude control and three-axis translation. This capability must be provided for external tank separation, on-orbit operation, deorbit, and reentry. In order to meet these requirements a bipropellant, pressure-fed system utilizing monomethylhydrazine as fuel, and nitrogen tetroxide as oxidizer has been selected. The RCS engines include 38 primary thrusters rated at 870 lbf thrust and 6 vernier thrusters rated at 25 lbf thrust. The system is divided into three removable modules (one forward and two aft) to achieve maintenance and turnaround requirements. In order to provide additional mission flexibility, the aft modules can be connected together or interconnected with the OMS (orbital maneuvering system).

Blevins, D. R.↗

Evaluating Interconnection Queue Impacts Using Hosting Capacity Analysis

The interconnection queue has been identified as a bottleneck in the efforts to shift the nations generation resources towards renewable sources and meet various state and federal goals. Efforts such as the interconnection innovation e-Xchange (i2X) are therefore trying to come up with ways in which the queue could be altered to make interconnection faster, cheaper, and fairer. This paper proposes using hosting capacity analysis methods to simulate the evolution of a power system as new resources are added. Modeling the interconnection process in this way enables simulation based study of various policy decisions for queue management and cost allocation. Sample results are presented to illustrate how some queue modifications might play out both in distribution and transmission systems.

Distributed Energy Resources, Interconnection↗

Evaluating software defined networking solutions to reduce the digital attack surface of nuclear security systems

Most nuclear security systems used today were not designed for today’s threat environment. Systems that were intended to be stand alone are now interconnected. Devices that have a single purpose are built on multi-purpose platforms and communication protocols that, while effective, have no ability to authenticate authorized versus unauthorized commands. These attributes provide an attacker significant ability to affect the system, pivot throughout the interconnected networks, and remain undetected if he/she is able to compromise a single node. Software defined networking (SDN) has been used for years by information technology (IT) cloud service providers to quickly provision or remove servers or other systems to meet changing demand. The same concept has recently been applied to operational technology (OT) systems to enable very fast failover on critical systems that have stringent and deterministic (<5ms) transmit/receive times. By carefully engineering the communication flows through a network using preplanned routes and specific pathways it is possible to achieve deterministic and extremely reliable message delivery even when components fail. This engineering approach to network design has added security benefits including securing the networking control plane, eliminating network scanning and mapping, inhibiting ARP spoofing and host masquerading, eliminating unauthorized network pivoting and enabling greater situational awareness on the network. SDN in OT environments is new but early testing in electrical power and other critical infrastructure has shown it to be a very powerful tool for building reliable networks and reducing the digital attack surface of the network. The authors tested a software defined network switch on a simple physical protection system with components commonly found in nuclear security systems and found improved mitigations to denial of service attacks, lateral movement and network reconnaissance. The paper details the tests and their results.

Cyber security, Nuclear security, software defined↗

Real-time computer data system for the 40- by 80-foot wind tunnel facility at Ames Research Center

The background material and operational concepts of a computer-based system for an operating wind tunnel are described. An on-line real-time computer system was installed in a wind tunnel facility to gather static and dynamic data. The computer system monitored aerodynamic forces and moments of periodic and quasi-periodic functions, and displayed and plotted computed results in real time. The total system is comprised of several off-the-shelf, interconnected subsystems that are linked to a large data processing center. The system includes a central processor unit with 32,000 24-bit words of core memory, a number of standard peripherals, and several special processors; namely, a dynamic analysis subsystem, a 256-channel PCM-data subsystem and ground station, a 60-channel high-speed data acquisition subsystem, a communication link, and static force and pressure subsystems. The role of the test engineer as a vital link in the system is also described.

Cambra, J. M.↗

Reliability model generator

An improved method and system for automatically generating reliability models for use with a reliability evaluation tool is described. The reliability model generator of the present invention includes means for storing a plurality of low level reliability models which represent the reliability characteristics for low level system components. In addition, the present invention includes means for defining the interconnection of the low level reliability models via a system architecture description. In accordance with the principles of the present invention, a reliability model for the entire system is automatically generated by aggregating the low level reliability models based on the system architecture description.

McMann, Catherine M.↗

Scalable Adaptive Graphics Environment (SAGE) Software for the Visualization of Large Data Sets on a Video Wall

The use of collaborative scientific visualization systems for the analysis, visualization, and sharing of "big data" available from new high resolution remote sensing satellite sensors or four‐dimensional numerical model simulations is propelling the wider adoption of ultra‐resolution tiled display walls interconnected by high speed networks. These systems require a globally connected and well‐integrated operating environment that provides persistent visualization and collaboration services. This abstract and subsequent presentation describes a new collaborative visualization system installed for NASA's Shortterm Prediction Research and Transition (SPoRT) program at Marshall Space Flight Center and its use for Earth science applications. The system consists of a 3 x 4 array of 1920 x 1080 pixel thin bezel video monitors mounted on a wall in a scientific collaboration lab. The monitors are physically and virtually integrated into a 14' x 7' for video display. The display of scientific data on the video wall is controlled by a single Alienware Aurora PC with a 2nd Generation Intel Core 4.1 GHz processor, 32 GB memory, and an AMD Fire Pro W600 video card with 6 mini display port connections. Six mini display‐to‐dual DVI cables are used to connect the 12 individual video monitors. The open source Scalable Adaptive Graphics Environment (SAGE) windowing and media control framework, running on top of the Ubuntu 12 Linux operating system, allows several users to simultaneously control the display and storage of high resolution still and moving graphics in a variety of formats, on tiled display walls of any size. The Ubuntu operating system supports the open source Scalable Adaptive Graphics Environment (SAGE) software which provides a common environment, or framework, enabling its users to access, display and share a variety of data‐intensive information. This information can be digital‐cinema animations, high‐resolution images, high‐definition video‐teleconferences, presentation slides, documents, spreadsheets or laptop screens. SAGE is cross‐platform, community‐driven, open‐source visualization and collaboration middleware that utilizes shared national and international cyberinfrastructure for the advancement of scientific research and education.

Jedlovec, Gary↗

RAMA: A file system for massively parallel computers

This paper describes a file system design for massively parallel computers which makes very efficient use of a few disks per processor. This overcomes the traditional I/O bottleneck of massively parallel machines by storing the data on disks within the high-speed interconnection network. In addition, the file system, called RAMA, requires little inter-node synchronization, removing another common bottleneck in parallel processor file systems. Support for a large tertiary storage system can easily be integrated in lo the file system; in fact, RAMA runs most efficiently when tertiary storage is used.

Miller, Ethan L.↗

Evolution of Distributed Energy Resource Grid Interconnection Standards for Integrating Emerging Storage Technologies

Grid interconnection standards facilitate safe and reliable grid integration of distributed energy resources (DERs). Evolution of a standard for DERs is expected to capture and accommodate widely different characteristics of DER and minimize unique grid integration challenges. This makes development of a uniform grid interconnection standard for all types of DERs a challenging and an ever-evolving consideration. This paper presents a detailed timeline of evolution, from the early 2000s to 2018, of DER interconnection standards and the research that informed their development. This is followed by a review of the research topics being considered in the grid integration of Energy Storage Systems (ESSs) which are expected to have the most significant growth amongst all DER types. These help in highlighting the need for a new standard to accommodate the unique characteristics of ESSs, and where the existing DER interconnection standard frameworks may be leveraged.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission system protection screening for integration of offshore wind power plants

This paper develops an efficient methodology for protection screening of large-scale transmission systems as part of the planning studies for the integration of offshore wind power plants into the power grid. This methodology avails to determine whether any upgrades are required to the protection system. The uncertainty is considered in form of variability of the power generation by offshore wind power plant. This paper uses the integration of a 1000 MW offshore wind power plant operating in Lake Erie into the FirstEnergy/PJM service territory as a case study. This study uses a realistic model of a 63,000-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗