Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

High resolution and fast scanning squid based non-destructive inspection system of niobium sheets for SRF cavities

Applications in high energy physics accelerators and other fields require the use of thousands of superconducting RF (SRF) cavities that are made of high purity Nb material and the purity of niobium is critical for these cavities to reach the highest accelerating fields. Tantalum is the most prolific of metal inclusions, which can cause thermal breakdown and prevent the cavities from reaching their theoretical performance limits of 45-50 MV/m, and DOE Labs are searching for a technology that could detect small impurities in superconducting Nb sheets reaching the highest possible accelerating fields. The proposed innovative SQUID-based Nondestructive system can scan Niobium sheets used in the manufacturing of SRF cavities with both high speed and high resolution. A highly sensitive SQUID system with a gradiometer probe, non-magnetic dewar, data acquisition system, and a scanning system will be developed for fast detection of impurities in planar Nb sheets. In phase I, we will modify our existing SQUID-based eddy current system to detect 100 micron size Ta defects and a great effort will focus on achieving fast scanning of a large number of niobium sheets in a shorter time and with reasonable resolution. An older system operated by moving the sample 1 mm, stopping and waiting for 1-2 seconds, then activating a measurement by the SQUID after the short settle time is modified. A preliminary designed and implemented a SQUID scanning system that is fast and is capable of scanning a 30 cm x 30 cm Nb sheet in 15 minutes by continuously moving the table at speeds up to 10 mm/s while activating the SQUID at 1mm interval is modified and reached the Phase I goal of 100mm resolution. We have successfully demonstrated the feasibility that a fast speed SQUID scanner without sacrificing the resolution of detection can be done, and a data acquisition and analysis system is also preliminary developed. The SQUID based scanner will help reach the highest accelerating field in SRF cavities that will provide a considerable cost reduction for new accelerators and for upgrades of existing accelerators. This will be realized either by reducing the length required for the SRF cavities or by the installation of higher gradient cavities for energy upgrades in the same space. The SQUID based scanner will also be used for the detection of defects on the surface, inside the bulk or at the back side of metallic sheets in other industries.

43 PARTICLE ACCELERATORS↗

Radiotherapy With or Without Concurrent Chemotherapy for Lymph Node Recurrence After Radical Surgery of Thoracic Esophageal Squamous Cell Carcinoma

Purpose: To retrospectively compare the outcomes of patients with lymph node recurrence after radical surgery of esophageal cancer, when given radiotherapy with or without concurrent chemotherapy. Methods and Materials: Between January 1996 and December 2005, the data from 73 patients with lymph node recurrence after radical surgery of thoracic esophageal squamous cell carcinoma were retrospectively reviewed. The patients were separated into two groups: radiochemotherapy (RC, 31 patients) and radiotherapy alone (RA, 42 patients). Patients in the RC group received at least two cycles of 5-fluorouracil/cisplatin chemotherapy concurrently with radiotherapy. Results: The median duration of follow-up was 11 months (range, 2-48). The overall survival rate for all patients was 46.7% and 4.7% at 1 and 3 years, respectively. The median overall survival time was 9 months (95% confidence interval, 6.96-11.04) and 17 months (95% confidence interval, 13.61-20.39) for RA and RC groups, respectively. The survival rate at 1 and 3 years was 62.5% and 10.5% in the RC group and 33.8% and 0% in the RA group (p = .0049, log-rank test; hazard ratio for death, 0.52; 95% confidence interval, 0.30-0.92). Acute toxicities were more frequent in the RC group than in the RA group. No significant differences were found in the late toxicity profiles between the two groups. Conclusion: The results of the present retrospective analysis suggest that RC should be considered an effective and well-tolerated treatment of patients with thoracic esophageal squamous cell carcinoma and postoperative lymph node recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Composition and structure of acid leached LiMn{sub 2-y}Ti{sub y}O{sub 4} (0.2<=y<=1.5) spinels

Lithium manganese titanium spinels, LiMn{sub 2-y}Ti{sub y}O{sub 4}, (0.2<=y<=1.5) have been synthesized by solid-state reaction between TiO{sub 2} (anatase), Li{sub 2}CO{sub 3} and MnCO{sub 3}. Li{sup +} was leached from the powdered reaction products by treatment in excess of 0.2 N HCl at 85 deg. C for 6 h, under reflux. The elemental composition of the acidic solution and solid residues of leaching has been determined by complexometric titration, atomic absorption spectroscopy and X-ray fluorescence analysis. Powder X-ray diffraction was used for structural characterization of the crystalline fraction of the solid residues. It has been found that the amount of Li{sup +} leached from LiMn{sub 2-y}Ti{sub y}O{sub 4} decreases monotonically with increasing y in the interval 0.2<=y<=1.0 and abruptly drops to negligibly small values for y>1.0. The content of Mn and Li in the liquid phase and of Mn and Ti in the solid (amorphous plus crystalline) residue, were related to the composition and cation distribution in the pristine compounds. A new formal chemical equation describing the process of leaching and a mechanism of the structural transformation undergone by the initial solids as a result of Li{sup +} removal has been proposed. - Graphical abstract: Schematic representation of the acid leaching of LiMn{sub 2-y}Ti{sub y}O{sub 4} (0.2<=y<=1.0).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local Recurrence of Benign, Borderline, and Malignant Phyllodes Tumors of the Breast: A Systematic Review and Meta-analysis

Background: This systematic review and meta-analysis aimed to investigate local recurrence (LR) rates among the three grades (benign, borderline, and malignant) of phyllodes tumors (PTs). The study also assessed various risk factors for LR. Methods: Electronic articles published between 1 January 1995 and 31 May 2018, were searched and critically appraised. The authors independently reviewed the abstracts and extracted data for LR rates and LR risk factors. Results: The review incorporated 54 studies with 9234 individual cases. The pooled LR rates were 8% for benign, 13% for borderline, and 18% for malignant PTs. The risk of LR was significantly increased by borderline versus benign PTs (odds ratio [OR] 2.00; 95% confidence interval [CI] 1.68–2.38) and malignant versus borderline PTs (OR 1.28; 95% CI 1.05–1.55). The significant risk factors for LR were mitoses, tumor border (infiltrating vs. pushing), stromal cellularity (moderate/severe vs. mild), stromal atypia (severe vs. mild/absent), stromal overgrowth (severe vs. mild/absent), and tumor necrosis (positive vs. negative). Age and tumor size were not associated with LR risk. The subgroup analysis showed that breast-conserving surgery versus mastectomy and positive versus negative surgical margins were significantly associated with an increased LR risk only in malignant PTs. Conclusions: The risk of LR was significantly increased from benign to borderline to malignant PTs. Mitoses, tumor border, stromal cellularity, stromal atypia, stromal overgrowth, tumor necrosis, type of surgery, and surgical margin status may be risk factors for LR. Different management strategies could be considered for different PT grades.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Parentage Assignment and DNA Genotyping to Validate Scale Analysis for Estimating Steelhead Age and Spawning History

Abstract Sound fisheries management depends on understanding life history characteristics, such as age at maturity, migration, and spawning history; hard parts, such as scales and otoliths, are commonly used to estimate values for these traits. Validation of these techniques is often difficult but critical because errors in mean values for a population can result in erroneous estimates of sustainable exploitation rates. In this study, we compared information on age and spawning history derived from genetic analysis with information from scale analysis for 1,836 individual steelhead Oncorhynchus mykiss representing two life history stages (smolt and mature adult); these fish were of hatchery and wild origin and were sampled from two rivers in Washington State over a period of 19 years. Aging error rates were less than 5% for both wild smolts and hatchery adults, but the error rate for wild adults was much higher (13%; 95% confidence interval [CI] = 1.82–29.22%). Adult scale ages were biased; scale readers typically overestimated the ages of younger fish and underestimated the ages of older fish. In addition to the errors in age estimation, repeat spawners were misclassified as virgin spawners 6.5% of the time (95% CI = 0.79–20.26%). The higher error rates obtained in using scales for aging and identifying repeat spawning in wild adults may partly stem from the more complex life history relative to that of smolts or hatchery-origin adults; these results highlight the need for verification of scale analysis, especially for wild steelhead populations.

Seamons, Todd R.↗

Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors

Purpose: The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. Methods: The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 {mu}Gy air KERMA) to the detector. Results: The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r{sup 2} = 0.9999). The dependence was greater than unity (m = 1.101 {+-} 0.006), and the difference from unity was statistically significant (p < 0.005). The SD of mean SNR after calibration also exhibited linear dependence on the SD of the mean SNR before calibration (r{sup 2} = 0.9997). This dependence was less than unity (m = 0.822 {+-} 0.008), and the difference from unity was also statistically significant (p < 0.005). Systems were separated into two groups: systems with a precalibration SNR higher than the median SNR (N = 7), and those with a precalibration SNR lower than the median SNR (N = 7). Posthoc analysis was performed to correct for expanded false positive results. After calibration, the authors noted differences in mean SNR within both high and low groups, but these differences were not statistically significant at the 0.05 level. SNR data from four additional systems and one system from those previously tested after replacement of its detector were compared to the 95% confidence intervals (CI) calculated from the postcalibration SNR data. The comparison indicated that four of these five systems were consistent with the CI derived from the previously tested 14 systems after calibration. Two systems from the paired group that remained outside the CI were studied further. One system was remedied with a grid replacement. The nonconformant behavior of the other system was corrected by replacing the image receptor. Conclusions: Exposure-dependent SNR measurements under conditions simulating thoracic imaging allowed us to develop criteria for digital flat-panel imaging systems from a single manufacturer. These measurements were useful in identifying systems with discrepant performance, including one with a defective grid, one with a defective detector, and one that had not been calibrated for gain and offset. The authors also found that the gain and offset calibration reduces variation in exposure-dependent SNR performance among the systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A time convolution less density matrix approach to the nonlinear optical response of a coupled system-bath complex

Time convolution less density matrix theory (TCL) is a powerful and well established tool to investigate strong system-bath coupling for linear optical spectra. We show that TCL equations can be generalised to the nonlinear optical response up to a chosen order in the optical field. This goal is achieved via an time convolution less perturbation scheme for the reduced density matrices of the electronic system. In our approach, the most important results are the inclusion of a electron-phonon coupling non-diagonal in the electronic states and memory effects of the bath: First, the considered model system is introduced. Second, the time evolution of the statistical operator is expanded with respect to the external optical field. This expansion is the starting point to explain how a TCL theory can treat the response up to in a certain order in the external field. Third, new TCL equations, including bath memory effects, are derived and the problem of information loss in the reduced density matrix is analysed. For this purpose, new dimensions are added to the reduced statistical operator to compensate lack of information in comparison with the full statistical operator. The theory is benchmarked with a two level system and applied to a three level system including non-diagonal phonon coupling. In our analysis of pump-probe experiments, the bath memory is influenced by the system state occupied between pump and probe pulse. In particular, the memory of the bath influences the dephasing process of electronic coherences developing during the time interval between pump and probe pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systemic Lupus Erythematosus, Radiotherapy, and the Risk of Acute and Chronic Toxicity: The Mayo Clinic Experience

Purpose: To determine the acute and chronic toxic effects of radiotherapy in patients with systemic lupus erythematosus (SLE). Methods and Materials: Medical records of 21 consecutive patients with SLE, who had received 34 courses of external beam radiotherapy and one low-dose-rate prostate implant, were retrospectively reviewed. Patients with discoid lupus erythematosus were excluded. Results: Median survival was 2.3 years and median follow-up 5.6 years. Eight (42%) of 19 patients evaluable for acute toxicity during radiotherapy experienced acute toxicity of Grade 1 or greater, and 4 (21%) had acute toxicity of Grade 3 or greater. The 5- and 10-year incidence of chronic toxicity of Grade 1 or greater was 45% (95% confidence interval [CI], 22-72%) and 56% (95% CI, 28-81%), respectively. The 5- and 10-year incidence of chronic toxicity of Grade 3 or greater was 28% (95% CI, 18-60%) and 40% (95% CI, 16-72%), respectively. Univariate analysis showed that chronic toxicity of Grade 1 or greater correlated with SLE renal involvement (p < 0.006) and possibly with the presence of five or more American Rheumatism Association criteria (p < 0.053). Chronic toxicity of Grade 3 or greater correlated with an absence of photosensitivity (p < 0.02), absence of arthritis (p < 0.03), and presence of a malar rash (p < 0.04). Conclusions: The risk of acute and chronic toxicity in patients with SLE who received radiotherapy was moderate but was not prohibitive of the use of radiotherapy. Patients with more advanced SLE may be at increased risk for chronic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion Association in AlCl3 Aqueous Solutions from Constrained First-Principles Molecular Dynamics

Ab initio molecular dynamics was used to investigate the ion pairing behavior between Cl- and the Al3+ ion in an aqueous AlCl3 solution containing 63 water molecules. A series of constrained simulations was carried out at 300 K for up to 16 ps each, by fixing the inter-nuclear separation (rAl-Cl) between the Al3+ ion and one of the Cl- ions. The calculated potential of mean force of the Al3+-Cl- ion pair shows a pronounced minimum at rAl-Cl = 2.3 Å corresponding to a contact ion pair (CIP). Two local minima assigned to solvent separated ion pairs (SSIP) are identified at rAl-Cl= 4.4 and 6.0 Å. The positions of the free energy minima coincide with the hydration shell intervals of the Al3+ cation suggesting that the Cl- ion is inclined to reside in regions of low concentration of waters, i.e. between the 1st and 2nd shells of Al3+ and between the 2nd shell and bulk. A detailed analysis of solvent structure around the Al3+ and Cl- ions as a function of rAl-Cl is presented. The results are compared to structure data from X-ray measurements and unconstrained AIMD simulations of single ions Al3+ and Cl- and AlCl3 solutions. The dipole moment of the water molecules inside the 1st and 2nd hydration shells of Al3+ and in the bulk region and those of the Clion were calculated as a function of rAl-Cl. Major changes in the electronic structure of the system result from the removal of Cl- from the 1st hydration shell of the Al3+ cation. Finally, two unconstrained AIMD simulations of aqueous AlCl3 solutions corresponding to CIP and SSIP configurations were performed (17 ps, 300 K). Only minor structural changes are observed in these systems, confirming their stability.

ab initio↗

Global soil profiles indicate depth-dependent soil carbon losses under a warmer climate

Soil organic carbon (SOC) changes under future climate warming are difficult to quantify in situ. Here we apply an innovative approach combining space-for-time substitution with meta-analysis to SOC measurements in 113,013 soil profiles across the globe to estimate the effect of future climate warming on steady-state SOC stocks. We find that SOC stock will reduce by 6.0 ± 1.6% (mean±95% confidence interval), 4.8 ± 2.3% and 1.3 ± 4.0% at 0–0.3, 0.3–1 and 1–2 m soil depths, respectively, under 1 °C air warming, with additional 4.2%, 2.2% and 1.4% losses per every additional 1 °C warming, respectively. The largest proportional SOC losses occur in boreal forests. Existing SOC level is the predominant determinant of the spatial variability of SOC changes with higher percentage losses in SOC-rich soils. Our work demonstrates that warming induces more proportional SOC losses in topsoil than in subsoil, particularly from high-latitudinal SOC-rich systems.

54 ENVIRONMENTAL SCIENCES↗

Ion temperature effects on the occurrence scattering time in dusty plasmas

The effects of ion temperature on the occurrence scattering time for the electron-dust grain collision are investigated in dusty plasmas. The Eikonal analysis is applied to obtain the scattering amplitude and occurrence scattering time for the electron-dust collision. It is found that the occurrence scattering time represents the oscillatory behavior. It is also found that the amplitude and oscillation interval of the occurrence scattering are enhanced with increasing collision energy. It is found that the ion temperature effect suppresses the occurrence scattering time in three-component dusty plasmas. It is also found that the density effect reduces the occurrence scattering time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetics of positive ions and electrically neutral active particles in afterglow in neon at low pressure

Kinetics of positive ions and electrically neutral active particles formed during breakdown and successive discharge in neon-filled tube at 6.6 millibars pressure had been analyzed. This analysis was performed on the basis of mean value of electrical breakdown time delay t{sup ¯}{sub d} dependence on afterglow period τ (memory curve). It was shown that positive ions are present in the 1μs < τ < 30 ms interval, which is manifested through t{sup ¯}{sub d} slow increase with the increase of τ. A rapid t{sup ¯}{sub d} increase in the 30 ms < τ < 3 s interval is a consequence of significant decrease of positive ions concentration and dominant role in breakdown initiation have ground state nitrogen atoms, which further release secondary electrons from the cathode by catalytic recombination process. These atoms are formed during discharge by dissociation of ground state nitrogen molecules that are present as impurities in neon. For τ > 3 s, breakdown is initiated by cosmic rays and natural radioactivity. The increase of discharge current leads to decrease of t{sup ¯}{sub d} due to the increase of positive ions concentration in inter electrode gap. The increase of applied voltage also decreases t{sup ¯}{sub d} for τ > 30 ms due to the increase of the probability for initial electron to initiate breakdown. The presence of UV radiation leads to the decrease of t{sup ¯}{sub d} due to the increased electron yield caused by photoelectrons. The influence of photoelectrons on breakdown initiation can be noticed for τ > 0.1 ms, while they dominantly determine t{sup ¯}{sub d} for τ > 30 ms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A NEAR-INFRARED SPECTROSCOPIC SURVEY OF K-SELECTED GALAXIES AT z{approx} 2.3: COMPARISON OF STELLAR POPULATION SYNTHESIS CODES AND CONSTRAINTS FROM THE REST-FRAME NIR

We present spectral energy distribution (SED) modeling of a sample of 34 K-selected galaxies at z{approx} 2.3. These galaxies have near-infrared (NIR) spectroscopy that samples the rest-frame Balmer/4000 A break as well as deep photometry in 13 broadband filters. New to our analysis is Infrared Array Camera (IRAC) data that extend the SEDs into the rest-frame NIR. Comparing parameters determined from SED fits with and without the IRAC data we find that the IRAC photometry significantly improves the confidence intervals of {tau}, A{sub v} , M {sub star}, and SFR for individual galaxies, but does not systematically alter the mean parameters of the sample. We use the IRAC data to assess how well current stellar population synthesis codes describe the rest-frame NIR SEDs of young galaxies where discrepancies between treatments of the thermally pulsating asymptotic giant branch phase of stellar evolution are most pronounced. The models of Bruzual and Charlot, Maraston, and Charlot and Bruzual all successfully reproduce the SEDs of our galaxies with {<=}5% differences in the quality of fit; however, the best-fit masses from each code differ systematically by as much as a factor of 1.5, and other parameters vary more, up to factors of 2-3. A comparison of best-fit stellar population parameters from different stellar population synthesis (SPS) codes, dust laws, and metallicities shows that the choice of SPS code is the largest systematic uncertainty in most parameters, and that systematic uncertainties are typically larger than the formal random uncertainties. The SED fitting confirms our previous result that galaxies with strongly suppressed SF account for {approx}50% of the K-bright population at z{approx} 2.3; however, the uncertainty in this fraction is large due to systematic differences in the specific star formation rates derived from the three SPS models.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of cross sections and charged pion spectra in proton-carbon interactions at 31 GeV/c

Interaction cross sections and charged pion spectra in p+C interactions at 31 GeV/c were measured with the large-acceptance NA61/SHINE spectrometer at the CERN SPS. These data are required to improve predictions of the neutrino flux for the T2K long-baseline neutrino oscillation experiment in Japan. A set of data collected during the first NA61/SHINE run in 2007 with an isotropic graphite target with a thickness of 4% of a nuclear interaction length was used for the analysis. The measured p+C inelastic and production cross sections are 257.2 {+-} 1.9 {+-} 8.9 and 229.3 {+-} 1.9 {+-} 9.0 mb, respectively. Inclusive production cross sections for negatively and positively charged pions are presented as functions of laboratory momentum in ten intervals of the laboratory polar angle covering the range from 0 up to 420 mrad. The spectra are compared with predictions of several hadron production models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relic gravitational waves in light of the 7-year Wilkinson Microwave Anisotropy Probe data and improved prospects for the Planck mission

The new release of data from Wilkinson Microwave Anisotropy Probe improves the observational status of relic gravitational waves. The 7-year results enhance the indications of relic gravitational waves in the existing data and change to the better the prospects of confident detection of relic gravitational waves by the currently operating Planck satellite. We apply to WMAP7 data the same methods of analysis that we used earlier [W. Zhao, D. Baskaran, and L. P. Grishchuk, Phys. Rev. D 80, 083005 (2009)] with WMAP5 data. We also revised by the same methods our previous analysis of WMAP3 data. It follows from the examination of consecutive WMAP data releases that the maximum likelihood value of the quadrupole ratio R, which characterizes the amount of relic gravitational waves, increases up to R=0.264, and the interval separating this value from the point R=0 (the hypothesis of no gravitational waves) increases up to a 2{sigma} level. The primordial spectra of density perturbations and gravitational waves remain blue in the relevant interval of wavelengths, but the spectral indices increase up to n{sub s}=1.111 and n{sub t}=0.111. Assuming that the maximum likelihood estimates of the perturbation parameters that we found from WMAP7 data are the true values of the parameters, we find that the signal-to-noise ratio S/N for the detection of relic gravitational waves by the Planck experiment increases up to S/N=4.04, even under pessimistic assumptions with regard to residual foreground contamination and instrumental noises. We comment on theoretical frameworks that, in the case of success, will be accepted or decisively rejected by the Planck observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of ${{\mathrm{D}}^0}$, ${{\mathrm{D}}^+}$, ${{\mathrm{D}}^{*+}}$ and ${{\mathrm{D}}^+_{\mathrm{s}}}$ production in pp collisions at ${\sqrt{{\textit{s}}}~=~5.02~{\text {TeV}}}$ with ALICE

The measurements of the production of prompt D 0 , D + , D *+ , and D$_s^+$ mesons in proton–proton (pp) collisions at $\sqrt{s}$=5.02 TeV with the ALICE detector at the Large Hadron Collider (LHC) are reported. D mesons were reconstructed at mid-rapidity (|y| < 0.5) via their hadronic decay channels D 0 → K - $π$ + , D + → K - $π$ + $π$ + , D *+ → D 0 $π$ + → K - $π$ + $π$ + , D$_s^+$ → Φ$π$ + → K + K - $π$ + , and their charge conjugates. The production cross sections were measured in the transverse momentum interval 0 < $p$T < 36 GeV/$c$ for D 0 , 1 < $p$T < 36 GeV/$c$ for D + and D *+ , and in 2 < $p$T < 24 GeV/$c$ for D$_s^+$ mesons. Thanks to the higher integrated luminosity, an analysis in finer $p$T bins with respect to the previous measurements at $\sqrt{s}$ = 7 TeV was performed, allowing for a more detailed description of the cross-section $p$T shape. The measured $p$T differential production cross sections are compared to the results at √ s = 7 TeV and to four different perturbative QCD calculations. Its rapidity dependence is also tested combining the ALICE and LHCb measurements in pp collisions at $\sqrt{s}$ = 5.02 TeV. This measurement will allow for a more accurate determination of the nuclear modification factor in p–Pb and Pb–Pb collisions performed at the same nucleon– nucleon centre-of-mass energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Addendum to: Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) for Corrective Action Unit (CAU) 443: Central Nevada Test Area (CNTA)-Subsurface Central Nevada Test Area, DOE/NV-977

The environmental remediation closure process for the nuclear test at the Central Nevada Test Area (CNTA) has progressed from the approved Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) to this addendum. The closure process required the installation of three monitoring/validation (MV) wells and validation analysis of the flow and transport model. The model validation analysis led to the conclusion that the hydraulic heads simulated by the flow model did not adequately predict observed heads at the MV-1, MV-2, and MV-3 validation points (wells and piezometers). The observed heads from screened intervals near the test horizon were higher than the model predicted and are believed to be the result of detonation-related effects that have persisted since the nuclear test. These effects, which include elevated heads out from the detonation zone and lower heads in the immediate vicinity of the detonation, are seen at other nuclear tests and typically dissipate within a few years. These effects were not included in the initial head distribution of the model. The head variations at CNTA are believed to have persisted due to the very low permeability of the material at the detonation level.

54 ENVIRONMENTAL SCIENCES↗

Measurement of the Spin Correlation in the Top Quark Pair Production using the Dilepton Events in 1.96-TeV Proton-Antiproton Collisions

One of the most remarkable properties of the top quark is its extremely short lifetime, which allows us to observe the top quark spin at its production. That means a spin correlation at $t\bar{t}$ production is possible to be observed. In this thesis, we report on a measurement of the correlation coefficient between top quark spin and antitop quark spin in the beam basis at top quark pair production. We select $t\bar{t}$ pair production candidates by requiring two high transverse momentum leptons, two jets and large missing $E_T$ . In order to reconstruct the angular distribution of top quark decay products, we perform full kinematical reconstruction using predicted distributions of $p^{t\bar{t}}_z$ , $p^{t\bar{t}}_T$ and $M_{t\bar{t}}$. We make signal and background templates from admixture of Monte Carlo simulations and data-based background modelings. Then, we perform unbinned likelihood fit of angular distribution of data to signal and background templates and obtain result. This analysis is based on the data of 5.1 $fb^{-1}$ collected with the Collider Detector Facility (CDF) at the Fermilab Tevatron between March 2002 and June 2009. We observe 334 $t\bar{t}$ candidate events. We determine a confidence interval at 68% level for the correlation coefficient $\kappa$ to be -0.520 < $\kappa$ < 0.605 or $\kappa$ = $0.042^{+0.563}_{-0.562}$ on the assumption of $M_{top}$ = 172.5 GeV/$c^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗