Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Remote Fiber Based Velocimeter For Interface Strength Measurements

The understanding of the performance of nuclear reactor plate fuels is essential when developing new fuel systems. The condition of pre and post irradiated plate fuels must be characterized effectively and efficiently prior to irradiation and then post irradiation within a high rad environment. The post characterization work must be performed remotely and in an environment hostile to instrumentation. Laser based characterization methods provide the capability to be remote and robust within a hot-cell environment. Laser based characterization can provide high spatial resolution appropriate for scanning and imaging large areas. The INL is currently developing a laser shock system for Post Irradiation Examination (PIE) station for use in the Hot Fuel Examination Facility (HFEF) at the INL. The laser shock system is designed to characterize fuel to cladding and cladding to cladding interface strength. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad interface. The shock wave propagates as a compressional wave through the fuel plate to the free (unconfined) backside surface and is reflected back through the test plate as a rarefaction (tensile) wave. This rarefaction wave is the physical mechanism that produces internal delamination failure. The focus or this paper is on the accurate measurement of surface velocity to quantify the amount of energy traveling through the interfaces to the back surface of the fuel plate. The original fiber based velocimeter design was biased by parasitic back reflections. This paper will discuss the discovery of the back-reflection issue and the design changes to resolve the issue. Supporting data will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrating Risk in Humanoid Robot Control for Applications in the Nuclear Industry - 18230

This paper discuss the integration of risk into a robot control framework for decommissioning applications in the nuclear industry. Our overall objective is to allow the robot to evaluate a risk associated with several methods of completing the same task by combining a set of action sequences. If the environment is known and in the absence of sensing errors each set of actions would successfully complete the task. In this paper, instead of attempting to model the errors associated with each sensing system in order to compute an exact solution, a set of solutions are obtained along with a prescribed risk index. The risk associated with each set of actions can then be compared to possible payoffs or rewards, for instance task completion time or power consumption. This information is then sent to a high level decision planner, for instance a human teleoperator, who can then make a more informed decision regarding the robots actions. In order to illustrate the concept, we introduce three specific risk measures, namely, the collision risk and the risk of toppling and failure risk associated with grasping an object. We demonstrate the results from this foundational study of risk-aware compositional robot autonomy in simulation using NASA's Valkyrie humanoid robot, and the grasping simulator HAPTIX. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Human and Robotic Testing in Gloveboxes to Reduce Worker Fatigue - 19542

A DOE-sponsored study conducted by the Los Alamos National Laboratory reported that the incidence rate of repetitive stress injuries (RSI) during manipulation tasks in glovebox and hot cell workspaces increased from 22% after 1-2 hours of work per day to 50% after 3 hours of work per day due to fatigue, repetitive motion, and hyperextension. Robotics can be a viable solution to this issue as robotic manipulators and wearable robotic devices can provide effective assistance to alleviate the workload. In order to use the robotic devices, an initial study to detect the amount of fatigue experienced by the glovebox operators is essential. Hence, in the present research two objectives have been specified and investigated. These include the use of electromyography (EMG) sensors to precisely detect the fatigue in various hands, arm and shoulder muscles and; the use of dexterous robotic arm and hand combinations to effectively perform certain repetitive and monotonous tasks conducted inside an in-house glovebox constructed for the research. A UR5 robotic arm and an i-limb artificial hand have been used. Human tests included eight subjects and two customized glovebox tasks. Pilot scale test results indicate variation in the mean frequency which is an indication of the level of fatigue that occurred. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Double-Shell Tank Primary Bottom Visual Inspection Results - 20025

A pressing need for the Double-Shell Tank Integrity Program at Hanford is of the ability to inspect the bottom of the tanks. Though the DSTs' annulus spaces (the space between the internal and external tank walls) have been inspected visually since 1992 and with Ultrasonic Testing (UT) since 1996, inspections of the tank bottoms have been able to be conducted due to limitations of available technology, omitting about 40 percent of the tank surface below the maximum fill level from routine inspection. Visual inspections of the tank annulus have been conducted up to five times in some DSTs and portions of the annulus space for all of the DSTs has been inspected twice with UT. This region includes the walls of the primary tank and secondary liner along with accessible portions of the secondary liner bottom. Due to this lack of technology, the degradation of the primary tank bottom in Tank AY-102 was undetected until the tank leaked into its annulus space, confirmed in 2012. Since that time, WRPS has been working with the nondestructive examination community and the Pacific Northwest National Laboratory, to evaluate potential technologies to conduct these challenging remote inspections. Recent work has included the development, testing, and deployment of several remote visual inspection technologies to observe the condition of the primary tank bottom of the DSTs by leveraging air distribution slots in the refractory pad on which it rests. Robotic solutions to conduct this inspection were developed with a detailed understanding of the physical configuration and operational logistics. Understanding and subsequent communication of these details to vendors within the robotics and nondestructive examination community was a critical component to the successful production of these new tools. Throughout the FY16-FY18 years, vendors from nondestructive examination community were solicited for ideas to meet the tank bottom inspection challenge. Two tank bottom visual inspection solutions were then pursued to meet that challenge. Both tools were successfully deployed at Tank AP-107, and provided valuable visuals, never before obtained from the under tank environment of a double-shell tank. While there are minor opportunities for improvement identified with each system, general outcomes were overwhelmingly positive. Both systems were successfully able to navigate the refractory air slot pattern from the outer edge to the tank center and record video footage. The micro-crawler provided high quality and very stable footage through the air slot pattern, but took longer to deploy into the slots and traverse through them than the alternative system. The push-pull tethered camera was able to navigate all seven of its target air slots in a matter of a few hours, which included deployment, movement between slot entrances, and complete removal of the system from the annulus environment. Through these air slots, new information was gained about the tank bottom and refractory pad condition of tank AP-107, AP-106, AP-108, and AN-102. While some debris was noted in the air slots, including sand, chipped refractory, and construction materials, the refractory was found to be structurally stable and adequately supporting the primary tank bottom through the full diameter of the tank. Primary tank bottom steel exterior was found to be in good condition, free of ongoing or aggressive corrosion conditions. Looking toward the future, robotic access to and visual inspection of refractory air slots and the primary tank bottom steel has now proven viable. Incorporating periodic air slot inspections as a regular practice within the Double-Shell Tank Integrity Program is the next step, allowing trending of any changes in condition. As ultrasonic testing infrastructure was leveraged to complete the initial system deployments described in this report, it makes sense to adopt that same strategy for ongoing periodic examinations and deploy these primary tank bottom inspection tools alongside ultrasonic testing operations. Development of visual inspection tools to evaluate the primary tank bottom region of the double-shell tanks was planned as the first stage of inspection. Continued development of volumetric sensors and incorporation of these inspection tools into Hanford's ongoing Double-Shell Tank Integrity Program are the next steps, seeking to continuously expand understanding of asset integrity and remaining useful life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Sensors for the Advanced Test Reactor National Scientific User Facility

A key component of the ATR NSUF effort is to develop and evaluate new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. This paper describes the selection strategy of what instrumentation is needed, and the program generated for developing new or enhanced sensors that can address these needs. Accomplishments from this program are illustrated by describing new sensors now available to users of the ATR NSUF with data from irradiation tests using these sensors. In addition, progress is reported on current research efforts to provide users advanced methods for detecting temperature, fuel thermal conductivity, and changes in sample geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Future Developments in Low Temperature Detectors for CMB and Submm Astronomy

We summarize the wide range of current and upcoming developments in low temperature detectors for CMB and submillimeter astronomy. We discuss work in sensor development, photon coupling and filtering architectures, and polarimetry and how these tie to applications requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Low-Power and In Situ Annealing Mitigation Technique for Fast Neutrons Irradiation of Integrated Temperature Sensing Diodes

High doses of fast neutrons is detrimental to the performance of most common solid-state devices such as diodes and transistors. The ionizing effect is observed in particular for diodes used as simple integrated temperature sensors, or thermo-diodes, when their junction voltage is measured at constant current bias. In this work, we present a low-power and in situ mitigation technique based on Silicon-on-Insulator (SOI) micro-hot-plates to recover thermo-diodes. The basic operating principle consists in annealing the temperature-sensitive diodes integrated on the membrane during or after their irradiation in order to restore similar sensing characteristics over time. We measured thermo-diodes integrated to micro-hot-plates during their irradiation by fast neutrons (23 MeV peak) with total doses about 2.97±0.08 kGy. The membrane annealing is taking place at 450 deg. C using 40 mW of electrical power. Thanks to the annealing, the diode keeps a total measurement error below 0.5 deg. C. In this harsh radiation environment and beside the good tolerance of the thermo-diodes and the membrane materials to the total ionizing dose, the thermo-diode located on the heating membrane keeps a constant sensitivity. The demonstrated resistance of micro-hot-plates and the integrated thermo-diodes to fast neutron radiations can extend their use in nuclear plants and for radiation detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final CRADA Report for Enhanced and Miniaturized Wireless Valve Position Indicator Prototype

Most operating nuclear power plants (NPPs) in the United States have received approval to extend their operating licenses to 60 years. Now the nuclear industry is preparing to extend operating licenses to 80 years. While NPPs are preparing for extensions (60 years and beyond), the nuclear industry is facing a unique economic sustainability challenge in the current energy market. According to the Nuclear Energy Institute (NEI), generating costs of U.S. reactors have risen by 28% over the last 12 years, which is impacting the competitiveness of nuclear power in a market being increasingly penetrated by natural gas and renewable energy. This is partly because of the fact that the present nuclear work practice is dependent on a large technical staff which results in high operation and maintenance (O&M) costs, accounting for approximately 66% of the total operating cost. To address these concerns and abide by the NEI’s “Delivering the Nuclear Promise Initiative,” the U.S. utilities are embracing digitalization of their work practice to lower the O&M costs and increase productivity and efficiency while maintaining a safe and reliable operation. To address these above-mentioned concerns, Idaho National Laboratory (INL) researchers (proposal team) have developed a wireless valve position indication (VPI) sensor system that can be retrofitted on three main manual valve types (extendible to other manual valve types) to replace manual valve position verification with digital verification and enable online monitoring of manual valves. The developed technology 1) is evaluated for electromagnetic interference, 2) has a low power consuming and miniaturized electronic board, 3) is mounted on adjustable and reconfigurable sensor mounting unit that can fit on an actual flow-loop (at Idaho State University-ISU) to enable online monitoring of manual valve types without any valve body modification, and 4) ensures robust, secure, and reliable real-time communication of manual valve position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applying Temporal Data Mining (TDM) on the Baseline Data Acquired by the In-Situ Decommissioning (ISD) Sensor Network Test Bed - 18093

Researchers at Savannah River National Laboratory (SRNL) have established an In-Situ Decommissioning (ISD) Sensor Network Test Bed-a unique, small scale, configurable environment - for the assessment of prospective sensors on actual ISD system material at minimal cost. The data collected by the ISD sensors are ideal for applying temporal data mining (TDM) technique since they are time-specific, age-specific, and developmental stage-specific. In this research, TDM algorithms were applied on the baseline data collected by ISD test bed in the recent few years to seek frequency episodes in event stream. The tentative results prove that TDM techniques are effective tools for validating ISD performance. Frequent episodes in the data stream have confirmed the daily cycle of the sensor responses and establish sequences of different types of sensors, which was verified by the experimental setup of ISD Sensor Network Test Bed. The abnormal episodes in the data stream may lead to the early indicators of ISD system failures. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Submission of FeCrAl Feedstock for Support of AFC ATR-2 Irradiations

The Advanced Test Reactor (ATR) is currently being used to test accident tolerant fuel (ATF) forms destined for commercial nuclear power plant deployment. One irradiation program using the ATR for ATF concepts, Accident Tolerant Fuel-2 (ATF-2), is a water loop irradiation test using miniaturized fuel pins as test articles. This complicated testing configuration requires a series of pre-test experiments and verification including a flowing loop autoclave test and a sensor qualification test (SQT) prior to full test train deployment within the ATR. In support of the ATF-2 irradiation program, Oak Ridge National Laboratory (ORNL) has supplied two different Generation II FeCrAl alloys in rod stock form to Idaho National Laboratory (INL). These rods will be machined into dummy pins for deployment in the autoclave test and SQT. Post-test analysis of the dummy pins will provide initial insight into the performance of Generation II FeCrAl alloys in the ATF-2 irradiation experiment as well as within a commercial nuclear reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reduction of 1/f noise in graphene after electron-beam irradiation

We investigated experimentally the effect of the electron-beam irradiation on the level of the low-frequency 1/f noise in graphene devices. It was found that 1/f noise in graphene reduces with increasing concentration of defects induced by irradiation. The increased amount of structural disorder in graphene under irradiation was verified with micro-Raman spectroscopy. The bombardment of graphene devices with 20-keV electrons reduced the noise spectral density, S{sub I}/I{sup 2} (I is the source-drain current) by an order-of magnitude at the radiation dose of 10{sup 4} {mu}C/cm{sup 2}. We analyzed the observed noise reduction in the limiting cases of the mobility and carrier number fluctuation mechanisms. The obtained results are important for the proposed graphene applications in analog, mixed-signal, and radio-frequency systems, integrated circuits and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving the cross correlation method of indirect flow measurement by water injection and modeling - 245

This paper presents a technique to improve the Cross Correlation Function (CCF) method for indirect flow measurement. Unlike other methods, the CCF method does not need a specific instrument or tool for flow measurements. Instead, the delay time between two sensors can be derived by applying the CCF. A water flow loop was constructed to investigate the CCF method for flow measurement. Because the inherent process temperature variations were small when compared to significant amounts of measurement and process noise, inaccurate flow measurements were obtained. The performance of the CCF method could be improved by increasing the system signal-to-noise ratio, which is the process noise divided by the measurement noise. For this reason, a periodic injection of different temperature water was used to increase the process temperature variation. The results were favorable. However, several design variables needed to be selected. To assist, a CFD simulation was utilized to optimize the distance between sensors and injection point, the rate of injection flow, and other related variables. The results show that CCF optimization of these variables produces better flow measurement performance over a range of flow velocities. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Advanced Instrumentation for Transient Testing

A fuel safety research program centered on in-pile transient testing experiments is being developed to support assessment and qualification of advanced nuclear fuel systems using the recently restarted Transient Reactor Test (TREAT) facility at the Idaho National Laboratory (INL). While resumption of transient testing at TREAT is crucial to enable these programs, full recovery and cutting-edge transient testing capability also requires a well-coordinated and innovative instrumentation development and qualification program to support near-term and future objectives. This paper summarizes the experimental approach of transient testing to focus on measuring the response of nuclear fuel to off-normal (or power-cooling mismatch) conditions for modern and advanced reactor environments requiring capabilities extending over wide measurement and environment conditions. It also highlights unique attributes of transient testing of importance to in-pile instruments including relatively low total neutron fluence, high gamma heating, and the need for well-defined and possibly short time response. Historical approaches to instrumentation for transient testing are also reviewed to provide context to the modern instrument strategy. The instrumentation needs of a modern transient testing are detailed while summarizing several ongoing R&D activities are supporting the development of state-of-the-art and ‘advanced’ measurement technologies that will provide baseline capability for Light Water Reactor (LWR) and Sodium-Cooled Fast Reactor (SFR) experiment objectives, while extending to other advanced reactor needs and advanced sensing technology opportunities. Examples of specific sensors planned for near-term deployment with ongoing development includes prompt-response self-powered neutron detectors (SPND), miniature fission chambers, optical-fiber-coupled infrared pyrometer, cladding surface thermocouples, electrical-impedance based boiling detector, and Linear Variable Differential Transformer (LVDT) based sensors for fuel elongation and pressure measurement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reducing the capacitance of piezoelectric film sensors

We present a novel design for large area, wideband, polymer piezoelectric sensor with low capacitance. The large area allows better spatial resolution in applications such as photoacoustic tomography and the reduced capacitance eases the design of fast transimpedance amplifiers. The metalized piezoelectric polymer thin film is segmented into N sections, electrically connected in series. In this way, the total capacitance is reduced by a factor 1/N{sup 2}, whereas the mechanical response and the active area of the sensor are not modified. We show the construction details for a two-section sensor, together with the impedance spectroscopy and impulse response experimental results that validate the design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Augmented Reality Technologies for Radiation Safety Training: A Systematic Review of Sensor Integration and Visualization Approaches

This paper presents a comprehensive systematic review examining the application of augmented reality (AR) and sensor technologies for visualizing ionizing radiation in virtual training environments. The review methodology involved systematic identification and analysis of the relevant literature based on predetermined criteria including publication type, year of publication, application domain, and technological approach. The literature search encompassed publications from 2011 to 2021 across four major academic databases: Web of Science, Google Scholar, IEEE Xplore, and Scopus. Through rigorous screening following PRISMA 2020 guidelines, 23 research articles met the inclusion criteria for detailed analysis. From 404 initial database records, 360 were excluded during title/abstract screening (primarily for lacking AR components, radiation focus, or training applications) and 4 during full-text assessment (all for lacking sensor integration). The findings reveal that AR-based ionizing radiation visualization has been successfully implemented across diverse domains, including nuclear facility operations, medical procedures, CERN research activities, and educational and monitoring applications. The analysis identified multiple dimensions of impact, encompassing distinct benefits, emerging opportunities, and implementation challenges associated with AR deployment for ionizing radiation training. Each of these dimensions is comprehensively examined and documented within this review. Additionally, this study identifies critical research gaps that currently limit the full potential of AR technology in supporting ionizing radiation training programs. These gaps are systematically analyzed and discussed to establish clear directions for future research endeavors in this emerging field.

61 - RADIATION PROTECTION AND DOSIMETRY↗