Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

The Impacts of Cabin Atmosphere Quality Standards and Control Loads on Atmosphere Revitalization Process Design

Maintaining the cabin atmosphere’s pressure, composition, and quality within specified parameters is a necessity for successful crewed space exploration missions. A properly maintained environment minimizes health impacts on the occupants and maximizes their comfort. The challenge is to accomplish this outcome economically. The insight gained during the International Space Station’s (ISS) operational lifetime is driving toward more challenging cabin atmospheric quality standards for future exploration missions. At the same time, the metabolic loads are increasing to accommodate a broader crew body size range and more rigorous exercise protocols to mitigate health effects associated with long duration microgravity exposure. Compounding this situation is new process equipment for handling trash and waste that may vent contaminants into the cabin. The limits placed on the cabin atmospheric quality parameters combined with the contaminant load define the design space for the atmosphere revitalization (AR) subsystem technologies to be deployed aboard the spacecraft. The impacts of changes to cabin atmospheric quality standards and contamination loads are evaluated and implications to future crewed exploration missions are explored.

Perry, Jay L.↗

A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation

Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications.

47 OTHER INSTRUMENTATION↗

Making tomorrow's mistakes today: Evolutionary prototyping for risk reduction and shorter development time

In the early days of JPL's solar system exploration, each spacecraft mission required its own dedicated data system with all software applications written in the mainframe's native assembly language. Although these early telemetry processing systems were a triumph of engineering in their day, since that time the computer industry has advanced to the point where it is now advantageous to replace these systems with more modern technology. The Space Flight Operations Center (SFOC) Prototype group was established in 1985 as a workstation and software laboratory. The charter of the lab was to determine if it was possible to construct a multimission telemetry processing system using commercial, off-the-shelf computers that communicated via networks. The staff of the lab mirrored that of a typical skunk works operation -- a small, multi-disciplinary team with a great deal of autonomy that could get complex tasks done quickly. In an effort to determine which approaches would be useful, the prototype group experimented with all types of operating systems, inter-process communication mechanisms, network protocols, packet size parameters. Out of that pioneering work came the confidence that a multi-mission telemetry processing system could be built using high-level languages running in a heterogeneous, networked workstation environment. Experience revealed that the operating systems on all nodes should be similar (i.e., all VMS or all PC-DOS or all UNIX), and that a unique Data Transport Subsystem tool needed to be built to address the incompatibilities of network standards, byte ordering, and socket buffering. The advantages of building a telemetry processing system based on emerging industry standards were numerous: by employing these standards, we would no longer be locked into a single vendor. When new technology came to market which offered ten times the performance at one eighth the cost, it would be possible to attach the new machine to the network, re-compile the application code, and run. In addition, we would no longer be plagued with lack of manufacturer support when we encountered obscure bugs. And maybe, hopefully, the eternal elusive goal of software portability across different vendors' platforms would finally be available. Some highlights of our prototyping efforts are described.

Friedman, Gary↗

Quantum Communication Networks for Energy Applications: Review and Perspective

Abstract The energy sector is expected to undergo significant changes in the coming decades with the advent of new technologies, including smart grid development, microgrid expansion, increasing electric vehicle and renewable energy usage, and enhanced measures to minimize greenhouse gas emission, among others. In tandem, these changes are expected to create new opportunities for the deployment of quantum technologies within the energy sector. Building on the authors' previous reviews on the current state of and future opportunities for quantum sensing, quantum computing and quantum simulations for energy sector applications, this work provides an overview of recent progress in quantum networking and communications for the energy industry, with a focus on platforms, devices, and protocols, including quantum teleportation and quantum key distribution. Specific areas of relevance to the energy sector are then analyzed, including the role of quantum networks for greenhouse gas monitoring, secure data collection and transmission in smart grids, nuclear power plants’ safety, facilitating oil and gas exploration, and other energy‐relevant applications. This review concludes with a brief overview of areas for future innovation, including the need for platforms for simulating quantum networks, quantum material and platform design, and computational approaches to accelerate quantum protocol discovery and development.

Paudel, Hari P.↗

Wavelets in medical imaging

The aim of this study is to provide emerging applications of wavelet methods to medical signals and images, such as electrocardiogram, electroencephalogram, functional magnetic resonance imaging, computer tomography, X-ray and mammography. Interpretation of these signals and images are quite important. Nowadays wavelet methods have a significant impact on the science of medical imaging and the diagnosis of disease and screening protocols. Based on our initial investigations, future directions include neurosurgical planning and improved assessment of risk for individual patients, improved assessment and strategies for the treatment of chronic pain, improved seizure localization, and improved understanding of the physiology of neurological disorders. We look ahead to these and other emerging applications as the benefits of this technology become incorporated into current and future patient care. In this chapter by applying Fourier transform and wavelet transform, analysis and denoising of one of the important biomedical signals like EEG is carried out. The presence of rhythm, template matching, and correlation is discussed by various method. Energy of EEG signal is used to detect seizure in an epileptic patient. We have also performed denoising of EEG signals by SWT.

60 APPLIED LIFE SCIENCES↗

Heat pump concepts for nZEB Technology developments, design tools and testing of heat pump systems for nZEB in the USA: Country report IEA HPT Annex 40 Task 2, Task 3 and Task 4 of the USA

The IEA HPT Annex 40 "Heat pump concepts for Nearly Zero Energy Buildings" deals with the application of heat pumps as a core component of the HVAC system for Nearly or Net Zero energy buildings (nZEB). This report covers Task 2 on the system comparison and optimisation and Task 3 dedicated to the development of adapted technologies for nZEB and field monitoring results of heat pump systems in nZEB. In the US team three institutions are involved and have worked on the following projects: The Oak Ridge National Laboratory (ORNL) will summarize development activities through the field demonstration stage for several integrated heat pump (IHP) systems electric ground-source (GS-IHP) and air-source (AS-IHP) versions and an engine driven AS-IHP version. The first commercial GS-IHP product was just introduced to the market in December 2012. This work is a contribution to Task 3 of the Annex. The University of Maryland will contribute a software development project to Task 2 of the Annex. The software ThermCom evaluates occupied space thermal comfort conditions accounting for all radiative and convective heat transfer effects as well as local air properties. The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net Zero Energy Residential Test Facility (NZERTF). This residential building was constructed on the NIST campus and officially opened in summer 2013. During the first year, between July 2013 and June 2014, baseline performance of the NZERTF was monitored under a simulated occupancy protocol. The house was equipped with an air-to-air heat pump which included a dedicated dehumidification operating mode. Outdoor conditions, internal loads and modes of heat pump operation were monitored. Field study results with respect to heat pump operation will be reported and recommendations on heat pump optimization for a net zero energy building will be provided. This work is a contribution to Task 3 of the Annex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the Partitioning of Inorganic Elements Consumed by Humans between the Various Fractions of Human Wastes: An Alternative Approach

The elemental composition of food consumed by astronauts is well defined. The major elements carbon, hydrogen, oxygen, nitrogen and sulfur are taken up in large amounts and these are often associated with the organic fraction (carbohydrates, proteins, fats etc) of human tissue. On the other hand, a number of the elements are located in the extracellular fluids and can be accounted for in the liquid and solid waste fraction of humans. These elements fall into three major categories - cationic macroelements (e.g. Ca, K, Na, Mg and Si), anionic macroelements (e.g. P, S and Cl and 17 essential microelements, (e.g. Fe, Mn, Cr, Co, Cu, Zn, Se and Sr). When provided in the recommended concentrations to an adult healthy human, these elements should not normally accumulate in humans and will eventually be excreted in the different human wastes. Knowledge of the partitioning of these elements between the different human waste fractions is important in understanding (a) developing waste separation technologies, (b) decision-making on how these elements can be recovered for reuse in space habitats, and (c) to developing the processors for waste management. Though considerable literature exists on these elements, there is a lack of understanding and often conflicting data. Two major reasons for these problems include the lack of controlled experimental protocols and the inherently large variations between human subjects (Parker and Gallagher, 1988). We have used the existing knowledge of human nutrition and waste from the available literature and NASA documentation to build towards a consensus to typify and chemically characterize the various human wastes. It is our belief, that this could be a building block towards integrating a human life support and waste processing in a closed system.

Wignarajah, Kanapathipillai↗

NASA's Human Research Program at The Glenn Research Center: Progress and Opportunities

The NASA Human Research Program is aimed at correcting problems in critical areas that place NASA human spaceflight missions at risk due to shortfalls in astronaut health, safety and performance. The Glenn Research Center (GRC) and partners from Ohio are significant contributors to this effort. This presentation describes several areas of GRC emphasis, the first being NASA s path to creating exercise hardware requirements and protocols that mitigate the effects of long duration spaceflight. Computational simulations will be a second area that is discussed. This includes deterministic models that simulate the effects of spaceflight on the human body, as well as probabilistic models that bound and quantify the probability that adverse medical incidents will happen during an exploration mission. Medical technology development for exploration will be the final area to be discussed.

Nall, Marsha↗

Mild Catalytic methods for Alkyl-Alkyl Bond Formation

Overview of Research Goals and Accomplishments for the Period 07/01/06 – 06/30/07: Our overall research goal is to transform the rapidly emerging synthetic chemistry involving alkyl-alkyl cross-couplings into more of a mechanism-based field so that that new, rationally-designed catalysts can be performed under energy efficient conditions. Our specific objectives for the previous year were 1) to obtain a proper electronic description of an active catalyst for alkyl-alkyl cross-coupling reactions and 2) to determine the effect of ligand structure on the rate, scope, selectivity, and functional group compatibility of C(sp3)-C(sp3) cross-coupling catalysis. We have completed both of these initial objectives and established a firm base for further studies. The specific significant achievements of the current grant period include: 1) we have performed magnetic and computational studies on (terpyridine)NiMe, an active catalyst for alkyl-alkyl cross couplings, and have discovered that the unpaired electron resides heavily on the terpyridine ligand and that the proper electronic description of this nickel complex is a Ni(II)-methyl cation bound to a reduced terpyridine ligand; 2) we have for the first time shown that alkyl halide reduction by terpyridyl nickel catalysts is substantially ligand based; 3) we have shown by isotopic labeling studies that the active catalyst (terpyridine)NiMe is not produced via a mechanism that involves the formation of methyl radicals when (TMEDA)NiMe2 is used as the catalyst precursor; 4) we have performed an extensive ligand survey for the alkyl-alkyl cross-coupling reactions and have found that electronic factors only moderately influence reactivity in the terpyridine-based catalysis and that the most dramatic effects arise from steric and solubility factors; 5) we have found that the use of bis(dialkylphosphino)methanes as ligands for nickel does not produce active catalysts for cross-coupling but rather leads to bridging hydride complexes of varying geometries; 6) we have determined that the geometry of aforementioned bridging hydride complexes is largely determined by external forces such as hydrogen bonding interactions and crystal packing forces; 7) we have found that the rate of reductive elimination of alkane from a (pyridyl-2-pyrrolide)AuMe2 complex is severely inhibited due to the rigid geometry of the pyridyl-2-pyrrolide ligand; 8) we have prepared, structurally characterized, and explored the reactivity of 1-adamantylzinc reagents as model nucleophiles for sterically challenging alkyl-alkyl cross-coupling reactions. The continued success of this work will lead to alkyl-alkyl cross-coupling catalysts with broad scope and selectivities. The work has potential to significantly impact science and technologies of interest to the DOE as the chemistry is focused on developing useful reactions using reagents that can be directly prepared from petroleum and natural gas feedstocks. Moreover, the developing synthetic chemistry can profoundly affect the way materials, fine chemicals, and drugs are made. Since the methodology we are developing can shorten existing synthetic protocols, proceed at room temperature, and operate under environmentally benign conditions, it can greatly reduce energy expenditures, especially considering the contribution of the chemical manufacturing field to the gross domestic product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature‐Dependent Crystallization in Two‐Step Perovskite Deposition Revealed by In Situ GIWAXS and Machine Learning‐Guided Analysis

The performance and stability of perovskite solar cells are strongly governed by the crystallization behavior of their active layer. In two-step sequential deposition, early-stage film formation plays a decisive role in determining final phase purity and device quality. Guided by a data-driven analysis of nearly 39 000 devices in the FAIR perovskite database, we identified solvent-mediated quenching and thermal processing as key variables affecting power conversion efficiency (PCE), particularly in two-step fabrication. Here, to investigate these effects in real time, we designed and implemented a custom-built, temperature-controlled spin-coating system, enabling precise thermal modulation during precursor deposition. Using this platform, we performed in situ GIWAXS measurements to study the crystallization dynamics of FA 0.5 MA 0.5 PbI 3 films over a temperature range of 30°C–90°C. Our results reveal a non-monotonic relationship between spin-coating temperature and α-phase formation, governed by the interplay between precursor interdiffusion, PbI 2 crystallinity, and δ-phase suppression. The custom thermal control enabled us to isolate and quantify these competing effects during the earliest stages of film formation, providing mechanistic insight into how spin-coating temperature governs both phase purity and kinetic pathways in two-step perovskite systems. Temperature-dependent SEM and photovoltaic device measurements further demonstrate that early-stage crystallization pathways directly translate into differences in morphology, charge-transport continuity, and device performance. These findings inform targeted strategies for optimizing deposition protocols to balance rapid nucleation, phase stability, and device performance.

Saadawy, Ahmed [King Fahd University of Petroleum ↗

Caveats and limitations of plate reader-based high-throughput kinetic measurements of intracellular calcium levels

Calcium plays a crucial role in virtually all cellular processes, including neurotransmission. The intracellular Ca{sup 2+} concentration ([Ca{sup 2+}]{sub i}) is therefore an important readout in neurotoxicological and neuropharmacological studies. Consequently, there is an increasing demand for high-throughput measurements of [Ca{sup 2+}]{sub i}, e.g. using multi-well microplate readers, in hazard characterization, human risk assessment and drug development. However, changes in [Ca{sup 2+}]{sub i} are highly dynamic, thereby creating challenges for high-throughput measurements. Nonetheless, several protocols are now available for real-time kinetic measurement of [Ca{sup 2+}]{sub i} in plate reader systems, though the results of such plate reader-based measurements have been questioned. In view of the increasing use of plate reader systems for measurements of [Ca{sup 2+}]{sub i} a careful evaluation of current technologies is warranted. We therefore performed an extensive set of experiments, using two cell lines (PC12 and B35) and two fluorescent calcium-sensitive dyes (Fluo-4 and Fura-2), for comparison of a linear plate reader system with single cell fluorescence microscopy. Our data demonstrate that the use of plate reader systems for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with many pitfalls and limitations, including erroneous sustained increases in fluorescence, limited sensitivity and lack of single cell resolution. Additionally, our data demonstrate that probenecid, which is often used to prevent dye leakage, effectively inhibits the depolarization-evoked increase in [Ca{sup 2+}]{sub i}. Overall, the data indicate that the use of current plate reader-based strategies for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with caveats and limitations that require further investigation. - Research Highlights: > The use of plate readers for high-throughput screening of intracellular Ca{sup 2+} is associated with many pitfalls and limitations. > Single cell fluorescent microscopy is recommended for measurements of intracellular Ca{sup 2+}. > Dual-wavelength dyes (Fura-2) are preferred over single-wavelength dyes (Fluo-4) for measurements of intracellular Ca{sup 2+}. > Probenecid prevents dye leakage but abolishes depolarization-evoked Ca{sup 2+} influx, severely hampering measurements of Ca{sup 2+}. > In general, care should be taken when interpreting data from high-throughput kinetic measurements.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-01: Absorbed Dose Rate-To-Water at the Surface of a Beta-Emitting Planar Ophthalmic Applicator with a Planar, Windowless Extrapolation Chamber

Purpose: Currently there is no primary calibration standard for determining the absorbed dose rate-to-water at the surface of β-emitting concave ophthalmic applicators and plaques. Machining tolerances involved in the design of concave window extrapolation chambers are a limiting factor for development of such a standard. Use of a windowless extrapolation chamber avoids these window-machining tolerance issues. As a windowless extrapolation chamber has never been attempted, this work focuses on proof of principle measurements with a planar, windowless extrapolation chamber to verify the accuracy in comparison to initial calibration, which could be extended to the design of a hemispherical, windowless extrapolation chamber. Methods: The window of an extrapolation chamber defines the electrical field, aids in aligning the source parallel to the collector-guard assembly, and decreases the backscatter due to attenuation of lower electron energy. To create a uniform and parallel electric field in this research, the source was made common to the collector-guard assembly. A precise positioning protocol was designed to enhance the parallelism of the source and collector-guard assembly. Additionally, MCNP5 was used to determine a backscatter correction factor to apply to the calibration. With these issues addressed, the absorbed dose rate-to-water of a Tracerlab 90Sr planar ophthalmic applicator was determined using National Institute of Standards and Technology's (NIST) calibration formalism, and the results of five trials with this source were compared to measurements at NIST with a traditional extrapolation chamber. Results: The absorbed dose rate-to-water of the planar applicator was determined to be 0.473 Gy/s ±0.6%. Comparing these results to NIST's determination of 0.474 Gy/s yields a −0.6% difference. Conclusion: The feasibility of a planar, windowless extrapolation chamber has been demonstrated. A similar principle will be applied to developing a primary calibration standard for concave applicators and plaques. This research is funded by the customers of the University of Wisconsin Accredited Dosimetry Calibration Laboratory.

07 ISOTOPE AND RADIATION SOURCES↗

WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

07 ISOTOPE AND RADIATION SOURCES↗

SpaceWire model development technology for satellite architecture.

Packet switched data communications networks that use distributed processing architectures have the potential to simplify the design and development of new, increasingly more sophisticated satellite payloads. In addition, the use of reconfigurable logic may reduce the amount of redundant hardware required in space-based applications without sacrificing reliability. These concepts were studied using software modeling and simulation, and the results are presented in this report. Models of the commercially available, packet switched data interconnect SpaceWire protocol were developed and used to create network simulations of data networks containing reconfigurable logic with traffic flows for timing system distribution.

33 ADVANCED PROPULSION SYSTEMS↗

Advanced Energy System Design (AESD): Technical Manual for the Records API

The Records API (application program interface) for Advanced Energy System Design (AESD) enables software that serves multidimensional record-oriented data to interoperate with software than uses such data. In the context of the Records API, multidimensional data records are simply tuples of real numbers, integers, and character strings, where each data value is tagged by a variable name, according to a pre-defined schema, and each record is assigned a unique integer identifier. Conceptually, these records are isomorphic to rows in a relational database, JSON objects, or key-value maps. Records servers might supply static datasets, sensor measurements that periodically update as new telemetry become available, or the results of simulations as the simulations generate new output. Records client software might display or analyze the data, but in the case of simulations the client request the creation of new ensembles for specified input parameters. It is also possible to chain records clients and servers together so that a client consuming data from a server might transform that data and serve it to further clients. This minimalist API avoids imposing burdensome metadata, structural, or implementation requirements on developers by relying on open-source technologies that is readily available for common programming languages. In particular, the API has been designed to place the smallest possible burden on services that provide data. This document defines the message format for the Records API, a transport mechanism for communicating the data, and semantics for interpreting it. The message format is specified as Google Protocol Buffers and the transport mechanism uses WebSockets. We discuss three major use cases for serving and consuming records data: (i) static data, (ii) dynamically augmented data, (iii) on-demand simulations, (iv) with filters, and (v) with bookmarks. Separate implementations of the API exist in C++, Haskell, JavaScript, Python, and R.

97 MATHEMATICS AND COMPUTING↗

Enhanced Microbial Detection Capabilities by a Rapid Portable Instrument

We present data describing a progression of continuing technology development - from expanding the detection capabilities of the current PTS unit to re-outfitting the instrument with a protein microarray increasing the number of detectable compounds. To illustrate the adaptability of the cartridge format, on-orbit operations data from the ISS demonstrate the detection of the fungal cell wall compound beta-glucan using applicable LOCAD-PTS cartridges. LOCAD-PTS is a handheld device consisting of a spectrophotometer, an onboard pumping mechanism, and data storage capabilities. A suite of interchangeable cartridges lined with four distinct capillaries allow a hydrated sample to mix with necessary reagents in the channels before being pumped to the optical well for spectrophotometric analysis. The reagents housed in one type of cartridge trigger a reaction based on the Limulus Amebocyte Lysate (LAL) assay, which results in the release of paranitroaniline dye. The dye is measured using a 395 nm filter. The LAL assay detects the Gram-negative bacterial cell wall molecule, endotoxin or lipopolysaccharide (LPS). The more dye released, the greater the concentration of endotoxin in the sample. Sampling, quantitative analysis, and data retrieval require less than 20 minutes. This is significantly faster than standard culture-based methods, which require at least a 24 hour incubation period.Using modified cartridges, we demonstrate the detection of Gram negative bacteria with protein microarray technology. Additionally, we provide data from multiple field tests where both standard and advanced PTS technologies were used. These tests investigate the transfer of target microbial molecules from one surface to another. Collectively, these data demonstrate that the new cartridges expand the number of compounds detected by LOCAD-PTS, while maintaining the rapid, in situ analysis characteristic of the instrument. The unit provides relevant data for verifying sterile sample collection protocols, which are critical for conducting accurate scientific experiments during future missions to the Moon and Mars.

Morris, Heather↗

Desert Research and Technology Studies (D-RATS) 2022 Test Report

The primary purpose of the 2022 Desert Research and Technology Studies (D-RATS 22) analog mission field test was to provide data and recommendations regarding how pressurized rover (PR) design, cabin configuration, driving modes, timeline constraints, and mission operations can be acceptably implemented to support future Artemis missions that include a PR. The goal of these evaluations was to provide first order feedback and data on design concepts currently being traded as options for future pressurized rover flight prototypes. The Japan Aerospace Exploration Agency (JAXA) may provide a PR for future Artemis missions. One of the primary objectives of D-RATS 2022 was to share with the JAXA PR team the processes and protocols by which NASA has learned to successfully evaluate rover concepts through integrated HITL evaluations over the past 20+ years, so that JAXA could apply any applicable lessons learned to their PR design, development, testing, and evaluation.

analog↗

Wave Energy Research, Testing and Demonstration Center

The purpose of this project was to build upon the research, development and testing experience of the Northwest National Marine Renewable Energy Center (NNMREC) to establish a non-grid connected open-ocean testing facility for wave energy converters (WECs) off the coast of Newport, Oregon. The test facility would serve as the first facility of its kind in the continental US with a fully energetic wave resource where WEC technologies could be proven for west coast US markets. The test facility would provide the opportunity for self-contained WEC testing or WEC testing connected via an umbilical cable to a mobile ocean test berth (MOTB). The MOTB would act as a “grid surrogate” measuring energy produced by the WEC and the environmental conditions under which the energy was produced. In order to realize this vision, the ocean site would need to be identified through outreach to community stakeholders, and then regulatory and permitting processes would be undertaken. Part of those processes would require environmental baseline studies and site analysis, including benthic, acoustic and wave resource characterization. The MOTB and its myriad systems would need to be designed and constructed.The first WEC test at the facility with the MOTB was completed within this project with the WET-NZ device in summer 2012. In summer 2013, the MOTB was deployed with load cells on its mooring lines to characterize forces on mooring systems in a variety of sea states. Throughout both testing seasons, studies were done to analyze environmental effects during testing operations. Test protocols and best management practices for open ocean operations were developed. As a result of this project, the non-grid connected fully energetic WEC test facility is operational, and the MOTB system developed provides a portable concept for WEC testing. The permitting process used provides a model for other wave energy projects, especially those in the Pacific Northwest that have similar environmental considerations. While the non-grid connected testing facility provides an option for WEC developers to prove their technology in a fully-energetic wave environment, the absence of grid connection is somewhat of a limitation. To prove that their technology is commercially viable, developers seek a multi-year grid connected testing option. To address this need, NNMREC is developing a companion grid connected test facility in Newport, Oregon, where small arrays of WECs can be tested as well.

16 TIDAL AND WAVE POWER↗