Search NASA⌕ Search

SEARCH · Search NASA

Results for “record”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Five year magnetic tape for unattended satellite tape recorders

The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

Benn, G. S. L.↗

Analysis of the failure of a polyester peripheral drive belt on the Mariner Mars 1971 flight tape recorder

A peripheral drive belt on the Mariner Mars 1971 tape recorder failed when a thin longitudinal strip separated off one edge. Analysis showed that the most probable cause of failure occurred from flexural fatigue initiating in mechanically weak locations which are introduced into the belt during fabrication. Methyl ethyl ketone, which is employed as a cleaning solvent during fabrication, was found to cause permanent reduction in engineering properties of polyester and could have contributed to the reduction of the fatigue resistance. Fatigue properties of the polyester drive belt are reviewed for the operating condition, as well as the sensitivity of polyester to cleaning solvents and the origin of mechanically weak locations.

Cuddihy, E. F.↗

A simple recording thickness gauge.

An account is given of the construction and operation of a device which allows an Instron universal testing machine to produce a continuous autographic record of thickness or contour of specimens and small parts. This device has proven useful in the nondestructive measurement of irregular cross sections.

Evans, R. E.↗

A new optical recording medium

Method has been developed for doping lithium niobiate crystals with transition metal to increase rate at which crystal can record optical data. Discovery may facilitate development of system for analog storage of TV frames, printed pages, photographs, and other visual information.

Aronson, H.↗

Automation of the Problem Oriented Medical Record

An improved ambulatory care delivery system developed for the Navy is examined. The system is centered around the concepts of problem oriented medical records and expanded use of paramedical personnel.

Schall, D. W.↗

Investigative study of holographic recording materials development

The potential of certain cis-trans isomers and doped LiNbO3 for the holographic read/write/erase memory application was investigated. The cis-trans work involved the photochemical investigation of a number of potential materials as well as specific molecular engineering efforts on alpha-methyl stilbene and its derivatives. These efforts resulted in an increase in the change in index of refraction, and thereby, in potential recording utility, of an order of magnitude. The work on LiNbO3 was directed toward a preliminary investigation of the dynamics of the writing process. Several samples and a variety of writing conditions were investigated. An unexpected and as yet unexplained improvement in material behavior with continued recycling was observed. In addition, some effort was devoted to an analysis of the physical conditions under which several current theories of the optical damage process are valid.

Source record↗

ERTS wideband tape recorder

The ERTS video bandwith tape recorder uses a rotary head to run the tape in transverse mode; the head wheel gives a head-to-tape surface speed of nearly 5080 centimeter per second. The electronics unit handles 15 megabit per second rate with a bit-error rate of 0.00001. An operational unit onboard ERTS A returned images from the 85 to 90 percent of the earth that are not available in real time.

Hayes, J. M.↗

A user's guide to the Mariner 9 television reduced data record

The Mariner 9 television experiment used two cameras to photograph Mars from an orbiting spacecraft. For quantitative analysis of the image data transmitted to earth, the pictures were processed by digital computer to remove camera-induced distortions. The removal process was performed by the JPL Image Processing Laboratory (IPL) using calibration data measured during prelaunch testing of the cameras. The Reduced Data Record (RDR) is the set of data which results from the distortion-removal, or decalibration, process. The principal elements of the RDR are numerical data on magnetic tape and photographic data. Numerical data are the result of correcting for geometric and photometric distortions and residual-image effects. Photographic data are reproduced on negative and positive transparency films, strip contact and enlargement prints, and microfiche positive transparency film. The photographic data consist of two versions of each TV frame created by applying two special enhancement processes to the numerical data.

Seidman, J. B.↗

The data-handling problem with television recording of spectra.

A television tube is a useful way to record a many-element picture such as is obtained from an echelle spectrograph. The signal on the tube target is scanned and relayed to the data-processing center where it must be reconstituted into the scene that was present in the focal plane of the spectrograph camera. A typical television frame will contain four million bits of information which must be processed to remove transmission errors and random noise pulses, to remove periodic noise, to correct for optical and electrical distortion, to remove sensitivity variations across the face of the tube, to calibrate from the photoelectrons back to incident energy, and to provide a wavelength scale. Results of a study of these problems is presented.

Underhill, A. B.↗

The particle track record of the lunar surface.

Information about lunar surface history revealed by fossil particle tracks is summarized. Such tracks are the result of damage left in dielectric materials by highly ionizing charged particles including heavy solar and galactic cosmic ray nuclei, heavy nuclei recoiling from cosmic ray induced spallation reactions, and induced- and spontaneous-fission fragments. From the distribution of cosmic ray and spallation tracks in the lunar rock, surface residence times of 1 to 30 million years and rock erosion rates of 1 to 10 A/yr have been determined. Particle tracks also record surface orientation and depth history of the rocks and contain information about ancient solar activity.

Comstock, G. M.↗

Particle track record of Apollo 15 green soil and rock.

Track densities, track stability, and uranium contents have been measured in lunar samples containing abundant green glass spherules from stations 6a and 7 of the Apollo 15 mission. This glass is rather homogeneous in its track registration properties but nonuniform in its uranium content, specific gravity, and bulk etching rate. The major components of a soil sample, 15401, are found to have had an unusually short surface exposure (500,000 yr) and to have been stirred at least once, but not often during its lifetime. A nearby soil clod, 15426, appears to have been brought to the surface in the same event. 15405, the rock upon which 15401 was perched, has recorded deformation features and track densities compatible with its surface residence having begun at the same time.

Fleischer, R. L.↗

Finger recording electrode system for electrical impedance plethysmograph

System facilitates location of recording electrodes of impedance plethysmograph that is used for measuring flow of blood in finger segment; electrodes can be relocated accurately and volume of finger segment under study can be determined precisely. System minimizes movement artifacts in plethysmograph trace because finger segment is held firmly.

Montgomery, L. D.↗

Analytical study of stresses recorded in the DH 2011 rotor blades

An analytical study of stresses in the blades recorded during the tests of the DH 2011 jet flap rotor was performed. The main objective of the study was to compare the experimental results with analyticaly determined stresses. The comparison extended over 15 specific flight cases has been only partially successful. In fact computed 3P and 4P stress components showed only a poor correlation with the test data obtained. It is believed that the simplified model of aeroelastic effects used is mainly responsible for this lack of agreement with test results.

Kretz, M.↗

A study of the temporal changes recorded by ERTS and their geological significance

The temporal changes that are recorded by ERTS were evaluated for an area around Bathurst Inlet in the North West Territories. The seasons represented by the images included: early winter, spring, early summer, summer, and fall. Numerous surface characteristics (vegetation, drainage patterns, surface texture, lineament systems and topographic relief, etc.) were used to relate the change in observable features with the different seasons. It was found that the time of year when an observation is made has a strong control over the amount and type of information that can be derived by an experienced interpreter. It was concluded that a detailed study of temporal changes is an important part of any ERTS interpretation for geology.

Moore, H. D.↗

Particle track record of Apollo 15 shocked crystalline rocks

Cosmic ray track densities in two mare basalts 15058 and 15555 are multivalued at each depth from the surface, and numerous indications of shock are present, suggesting that shock has lowered track densities in some crystals but not in others. From the minimum track densities, the maximum time since the last shock event is derived for each rock. In separate observations 15017, a black glass, has a surface age of about 14,000 years derived from impact pits, but because of low track retentivity a solar flare record of only 1 year.

Fleischer, R. L.↗

The paleomagnetic record in carbonaceous chondrites - Natural remanence and magnetic properties

Recent results of an intensive study of the natural remanence (NRM) and the magnetic properties of carbonaceous chondrites (CC) are summarized. It is convincingly demonstrated that the record of ancient magnetic fields has been preserved in these least-altered old samples of solar system material known. Intensities of specific NRM in the 13 meteorites surveyed span a broad range of values from 0.00005 to 0.5 emu/g. A low-temperature cleaning technique, based on the memory effect in magnetite grains, was followed by alternating field (af) demagnetization of the residual memory to exhibit the relative stability of NRM in the CC studied. No systematic correlation was found of either intensity or stability of NRM to af demagnetization with petrologic subtype, beyond a trend of increasing stability of memory from petrologic subtype C2 to subtype C4. The intensity and stability behavior of the saturation remanence are better suited for use in a magnetic classification of CC.

Brecher, A.↗

Holographic recording materials development

The area of organic cis-trans photoisomerization systems for holographic memory applications was examined. Photochemical studies were made of stilbene, indigo, and thioindigo derivatives in solution and in a variety of polymer matrix materials, to optimize the photorefractive behavior of the chemical system as a whole. Lithium niobate was used to study the writing and reading efficiencies of thick phase holograms. Both phase-wave holograms and Fourier-transform holograms were employed, and a number of reconstruction techniques are discussed. The possibility of using cis-trans photoisomerization of appropriate organic chemicals as the basis for a holographic recording system is confirmed.

Source record↗