Search NASA⌕ Search

SEARCH · Search NASA

Results for “reduced set methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Process-based cost estimation framework for assessing economic viability of environmentally and socially sustainable rare earth element feedstocks

Rare Earth Elements (REEs) are critical raw material inputs that are required to enable the energy transition. Constraints on the U.S. supply of conventional REE feedstocks and the desire to diversify U.S. reliance on foreign supply chains have motivated the pursuit of REE recovery from unconventional feedstocks including waste products. Recovery of REEs from unconventional sources is also motivated by environmental and social considerations, including the potential to offset new mining activity and subsidize the remediation of REE-containing wastes from coal, natural gas, and other mineral extraction activities. Sourcing REEs from unconventional feedstocks would reduce supply chain constraints and minimize the environmental impacts of REE extraction, but current processes to exploit these feedstocks have uncertain technical and economic performance and the processes have not been demonstrated at scale. This work aims to reduce uncertainty in evaluating the performance of new REE production pathways. A database of operating and capital expenses for REE recovery and establish consistent process unit costs for common stages in the conventional supply chain are developed. Market prices are used to develop well-defined methods for determining product values for a diverse set of products that can be generated (e.g. oxalates, alloys, end-use products such as magnets) but are not typically considered in technoeconomic analyses. Finally, to provide insight on the effects of economies of scale and feedstock purity on capital and operating costs, process unit level cost functions relating total costs per kilogram of REE produced are reported. These tools can be applied to assess and facilitate scale-up of REE production from diverse sources of REEs.

Fritz, Alison↗

SU-E-J-84: Quantitative Dosimetry Assessment of the Impact of Image Artifacts of Metal Implants in Spinal SABR Treatment

Purpose: Metal rods are frequently used to stabilize the spine in patients with metastatic disease. The high Z material causes imaging artifacts in the surrounding tissue in CT scans, which introduces dosimetric uncertainty when inhomogeneity correction is enabled for radiation treatment planning. The purpose of this study is to quantify the dosimetric deviations caused by the imaging artifacts and to evaluate the effectiveness of using Hounsfield units (HU) overwriting to reduce dosimetric uncertainties. Methods: We retrospectively reviewed treatment plans for 4 patients with metal implants who received stereotactic ablative radiation therapy (SABR) for metastatic disease to the spine on Tomotherapy HiArt. For all four patients, the region of imaging artifact surrounding the metal implants was contoured and the pixel HU’s were overwritten to be water equivalent. We then generated adaptive treatment plans for these patients using the MVCT pretreatment set up images and batched beamlets in the original treatment plans. The dosimetry deviation between the adaptive and original plans were compared and quantitatively analyzed. Results: For three out of four patient, the major OAR (spinal cord) dose (0.35cc or 10% according to protocols and fractionation) increased (2.7%, 5.5%, 0%, 3.9%, mean=3.0±2.3%, p=0.04), and the PTV dose (D90 or D95 as per prescription) increased for all four patients ( 2%, 5%, 0.7%, 3.6%, mean=2.8±1.9%, p=0.03) in the adaptive plan with HU overwriting. The average point dose deviation of the Tomotherapy DQA for the same patients was −1.0±1.0%. For plans without HU overwriting, the dose deviation from the treatment plan will increase. Conclusion: The metal implant and the imaging artifacts may cause a significant dosimetric impact on radiation treatment plans for spinal disease. The dose to the PTV and the spinal cord was under-calculated in treatment plans without considering the imaging artifacts. HU overwriting can reduce the dosimetry un-certainty.

60 APPLIED LIFE SCIENCES↗

Patient-Specific Three-Dimensional Concomitant Dose From Cone Beam Computed Tomography Exposure in Image-Guided Radiotherapy

Purpose: The purpose of the present study was to quantify the concomitant dose received by patients undergoing cone beam computed tomography (CBCT) scanning in different clinical scenarios as a part of image-guided radiotherapy (IGRT) procedures. Methods and Materials: We calculated the three-dimensional concomitant dose received as a result of CBCT scans in 6 patients representing different clinical scenarios: two pelvis, two head and neck, and two chest. We assessed the effect that a daily on-line IGRT strategy would have on the patient dose distribution, assuming 40 CBCT scans throughout the treatment course. The additional dose to the planning target volume margin region was also estimated. Results: In the pelvis, a single CBCT scan delivered a mean dose to the femoral heads of 2-6 cGy and the rectum of 1-2 cGy. An additional dose to the planning target volume was within 1-3 cGy. In the chest, the mean dose to the planning target volume varied from 2.5 to 5 cGy. The lung and spinal cord planning organ at risk volume received {<=}4 cGy and {<=}5 cGy, respectively. In the head and neck, a single CBCT scan delivered a mean dose of 0.3 cGy, with bony structures receiving 0.5-0.8 cGy. The femoral heads received an additional dose of 1.5-2.5 Gy. A reduction of 20-30% in the mean dose to the organs at risk was achieved using bowtie filtration. In the head and neck, the dose to the eyes and brainstem was eliminated by decreasing the craniocaudal field size. Conclusions: The additional dose from on-line IGRT procedures can be clinically relevant. The organ dose can be significantly reduced with the use of appropriate patient-specific settings. The concomitant dose from CBCT should be accounted for and the acquisition settings optimized for optimal IGRT strategies on a patient basis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multibeam optical apparatus and method for tracking control for an optical disk having a set of tracks

A multitrack optical disk has two or more circular or spiral tracks, which are recorded or played back in simultaneous sets for high data rates. Tracking is accomplished by sets of first and second tracking pads, which lie partially on and partially off the track paths. The amount of inter-track space required to accommodate the track pads is reduced by placing the overlap of the tracking pads in the same inter-track space, and by tracking any additional simultaneous tracks in excess of two by mechanical coupling with the first two.

Reno, Charles W.↗

A 1D–0D–3D coupled model for simulating blood flow and transport processes in breast tissue

In this work, we present mixed dimensional models for simulating blood flow and transport processes in breast tissue and the vascular tree supplying it. These processes are considered, to start from the aortic inlet to the capillaries and tissue of the breast. Large variations in biophysical properties and flow conditions exist in this system necessitating the use of different flow models for different geometries and flow regimes. In total, we consider four different model types. First, a system of 1D nonlinear hyperbolic partial differential equations (PDEs) is considered to simulate blood flow in larger arteries with highly elastic vessel walls. Second, we assign 1D linearized hyperbolic PDEs to model the smaller arteries with stiffer vessel walls. The third model type consists of ODE systems (0D models). It is used to model the arterioles and peripheral circulation. Finally, homogenized 3D porous media models are considered to simulate flow and transport in capillaries and tissue within the breast volume. Sink terms are used to account for the influence of the venous and lymphatic systems. Combining the four model types, we obtain two different 1D–0D–3D coupled models for simulating blood flow and transport processes: The first model results in a fully coupled 1D–0D–3D model covering the complete path from the aorta to the breast combining a generic arterial network with a patient specific breast network and geometry. The second model is a reduced one based on the separation of the generic and patient specific parts. The information from a calibrated fully coupled model is used as inflow condition for the patient specific sub-model allowing a significant computational cost reduction. Several numerical experiments are conducted to calibrate the generic model parameters and to demonstrate realistic flow simulations compared to existing data on blood flow in the human breast and vascular system. Moreover, we use two different breast vasculature and tissue data sets to illustrate the robustness of our reduced sub-model approach.

multiscale blood flow models↗

Simultaneous Optimization of Nuclear–Electronic Orbitals

Accurate modeling of important nuclear quantum effects, such as nuclear delocalization, zero-point energy, and tunneling, as well as non-Born-Oppenheimer effects, requires treatment of both nuclei and electrons quantum mechanically. The nuclear–electronic orbital (NEO) method provides an elegant framework to treat specified nuclei, typically protons, on the same level as the electrons. In conventional electronic structure theory, finding a converged ground state can be a computationally demanding task; converging NEO wavefunctions, due to their coupled electronic and nuclear nature, is even more demanding. Herein, we present an efficient simultaneous optimization method that uses the direct inversion in the iterative subspace method to simultaneously converge wavefunctions for both the electrons and quantum nuclei. In conclusion, benchmark studies show that the simultaneous optimization method can significantly reduce the computational cost compared to the conventional stepwise method for optimizing NEO wavefunctions for multicomponent systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-G-BRA-05: Predicting Volume Change of the Tumor and Critical Structures Throughout Radiation Therapy by CT-CBCT Registration with Local Intensity Correction

Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCT intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.

60 APPLIED LIFE SCIENCES↗

Prostate Contouring Variation: Can It Be Fixed?

Purpose: To assess whether an education program on CT and MRI prostate anatomy would reduce inter- and intraobserver prostate contouring variation among experienced radiation oncologists. Methods and Materials: Three patient CT and MRI datasets were selected. Five radiation oncologists contoured the prostate for each patient on CT first, then MRI, and again between 2 and 4 weeks later. Three education sessions were then conducted. The same contouring process was then repeated with the same datasets and oncologists. The observer variation was assessed according to changes in the ratio of the encompassing volume to intersecting volume (volume ratio [VR]), across sets of target volumes. Results: For interobserver variation, there was a 15% reduction in mean VR with CT, from 2.74 to 2.33, and a 40% reduction in mean VR with MRI, from 2.38 to 1.41 after education. A similar trend was found for intraobserver variation, with a mean VR reduction for CT and MRI of 9% (from 1.51 to 1.38) and 16% (from 1.37 to 1.15), respectively. Conclusion: A well-structured education program has reduced both inter- and intraobserver prostate contouring variations. The impact was greater on MRI than on CT. With the ongoing incorporation of new technologies into routine practice, education programs for target contouring should be incorporated as part of the continuing medical education of radiation oncologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of unsteady transonic flows using the integral equation method

The basic integral equations for a harmonically oscillating airfoil in a transonic flow with shock waves are derived; the reduced frequency is assumed to be small. The problems associated with shock wave motion are treated using a strained coordinate system. The integral equation is linear and consists of both line integrals and surface integrals over the flow field which are evaluated by quadrature. This leads to a set of linear algebraic equations that can be solved directly. The shock motion is obtained explicitly by enforcing the condition that the flow is continuous except at a shock wave. Results obtained for both lifting and nonlifting oscillatory flows agree satisfactorily with other accurate results.

Nixon, D.↗

Model Order Reduction Algorithm for Estimating the Absorption Spectrum

The ab initio description of the spectral interior of the absorption spectrum poses both a theoretical and computational challenge for modern electronic structure theory. Due to the often spectrally dense character of this domain in the quantum propagator’s eigenspectrum for medium-to-large sized systems, traditional approaches based on the partial diagonalization of the propagator often encounter oscillatory and stagnating convergence. Electronic structure methods which solve the molecular response problem through the solution of spectrally shifted linear systems, such as the complex polarization propagator, offer an alternative approach which is agnostic to the underlying spectral density or domain location. This generality comes at a seemingly high computational cost associated with solving a large linear system for each spectral shift in some discretization of the spectral domain of interest. In this work, we present a novel, adaptive solution to this high computational overhead based on model order reduction techniques via interpolation. Model order reduction reduces the computational complexity of mathematical models and is ubiquitous in the simulation of dynamical systems and control theory. The efficiency and effectiveness of the proposed algorithm in the ab initio prediction of X-ray absorption spectra is demonstrated using a test set of challenging water clusters which are spectrally dense in the neighborhood of the oxygen K-edge. On the basis of a single, user defined tolerance we automatically determine the order of the reduced models and approximate the absorption spectrum up to the given tolerance. We also illustrate that, for the systems studied, the automatically determined model order increases logarithmically with the problem dimension, compared to a linear increase of the number of eigenvalues within the energy window. Furthermore, we observed that the computational cost of the proposed algorithm only scales quadratically with respect to the problem dimension.

IDREAM, K-Edge, theoretical, computational, electr↗

Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full-field imaging by 259%, 279%, and 145% for SEDR, slot-scan, and full-field with grid, respectively. The average CNR over four regions was found to improve over that for nongrid full-field imaging by 201% for SEDR as compared to 133% for the slot-scan technique and 14% for the antiscatter grid method. Conclusions: Both SEDR and slot-scan techniques outperformed the antiscatter grid method used in standard full-field radiography. For imaging with the same effective exposure, the SEDR technique offers no advantage over the slot-scan method in terms of SPRs and CRs. However, it improves CNRs significantly, especially in heavily attenuating regions. The improvement of low-contrast performance may help improve the detection of the lung nodules or other abnormalities and may offer SEDR the potential for dose reduction in chest radiography.

60 APPLIED LIFE SCIENCES↗

Prediction of Silicon Content in a Blast Furnace via Machine Learning: A Comprehensive Processing and Modeling Pipeline

Silicon content plays an important role in determining the operational efficiency of blast furnaces (BFs) and their downstream processes in integrated steelmaking; however, existing sampling methods and first-principles models are somewhat limited in their capability and flexibility. Current data-based prediction models primarily rely on a limited set of manually selected furnace parameters. Additionally, different BFs present a diverse set of operating parameters and state variables that are known to directly influence the hot metal’s silicon content, such as fuel injection, blast temperature, and raw material charge composition, among other process variables that have their own impacts. The expansiveness of the parameter set adds complexity to parameter selection and processing. This highlights the need for a comprehensive methodology to integrate and select from all relevant parameters for accurate silicon content prediction. Providing accurate silicon content predictions would enable operators to adjust furnace conditions dynamically, improving safety and reducing economic risk. To address these issues, a two-stage approach is proposed. First, a generalized data processing scheme is proposed to accommodate diverse furnace parameters. Second, a robust modeling pipeline is used to establish a machine learning (ML) model capable of predicting hot metal silicon content with reasonable accuracy. The method employed herein predicted the average Si content of the upcoming furnace cast with an accuracy of 91% among 200 target predictions for a specific furnace provisioned by the XGBoost model. This prediction is achieved using only the past shift’s operating conditions, which should be available in real time. This performance provides a strong baseline for the modeling approach with potential for further improvement through provision of real-time features.

Chemistry↗

MRI-Based Computed Tomography Metal Artifact Correction Method for Improving Proton Range Calculation Accuracy

Purpose: Computed tomography (CT) artifacts can severely degrade dose calculation accuracy in proton therapy. Prompted by the recently increased popularity of magnetic resonance imaging (MRI) in the radiation therapy clinic, we developed an MRI-based CT artifact correction method for improving the accuracy of proton range calculations. Methods and Materials: The proposed method replaces corrupted CT data by mapping CT Hounsfield units (HU number) from a nearby artifact-free slice, using a coregistered MRI. MRI and CT volumetric images were registered with use of 3-dimensional (3D) deformable image registration (DIR). The registration was fine-tuned on a slice-by-slice basis by using 2D DIR. Based on the intensity of paired MRI pixel values and HU from an artifact-free slice, we performed a comprehensive analysis to predict the correct HU for the corrupted region. For a proof-of-concept validation, metal artifacts were simulated on a reference data set. Proton range was calculated using reference, artifactual, and corrected images to quantify the reduction in proton range error. The correction method was applied to 4 unique clinical cases. Results: The correction method resulted in substantial artifact reduction, both quantitatively and qualitatively. On respective simulated brain and head and neck CT images, the mean error was reduced from 495 and 370 HU to 108 and 92 HU after correction. Correspondingly, the absolute mean proton range errors of 2.4 cm and 1.7 cm were reduced to less than 2 mm in both cases. Conclusions: Our MRI-based CT artifact correction method can improve CT image quality and proton range calculation accuracy for patients with severe CT artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct computation of magnetic surfaces in Boozer coordinates and coil optimization for quasisymmetry

We propose a new method to compute magnetic surfaces that are parametrized in Boozer coordinates for vacuum magnetic fields. We also propose a measure for quasisymmetry on the computed surfaces and use it to design coils that generate a magnetic field that is quasisymmetric on those surfaces. The rotational transform of the field and complexity measures for the coils are also controlled in the design problem. Using an adjoint approach, we are able to obtain analytic derivatives for this optimization problem, yielding an efficient gradient-based algorithm. Starting from an initial coil set that presents nested magnetic surfaces for a large fraction of the volume, our method converges rapidly to coil systems generating fields with excellent quasisymmetry and low particle losses. In particular for low complexity coils, we are able to significantly improve the performance compared with coils obtained from the standard two-stage approach, e.g. reduce losses of fusion-produced alpha particles born at half-radius from $17.7\,\%$ to $6.6\,\%$ . We also demonstrate 16-coil configurations with alpha loss ${<}1\,\%$ and neoclassical transport magnitude $\epsilon _{\text {eff}}^{3/2}$ less than approximately $5\times 10^{-9}$ .

Physics↗

Machine Learning Classification Strategy to Improve Streamflow Estimates in Diverse River Basins in the Colorado River Basin

Streamflow in the Colorado River Basin (CRB) is significantly altered by human activities including land use/cover alterations, reservoir operation, irrigation, and water exports. Climate is also highly varied across the CRB which contains snowpack-dominated watersheds and arid, precipitation-dominated basins. Recently, machine learning methods have improved the generalizability and accuracy of streamflow models. Previous successes with LSTM modeling have primarily focused on unimpacted basins, and few studies have included human impacted systems in either regional or single-basin modeling. We demonstrate that the diverse hydrological behavior of river basins in the CRB are too difficult to model with a single, regional model. We propose a method to delineate catchments into categories based on the level of predictability, hydrological characteristics, and the level of human influence. Lastly, we model streamflow in each category with climate and anthropogenic proxy data sets and use feature importance methods to assess whether model performance improves with additional relevant data. Overall, land use cover data at a low temporal resolution was not sufficient to capture the irregular patterns of reservoir releases, demonstrating the importance of having high-resolution reservoir release data sets at a global scale. On the other hand, the classification approach reduced the complexity of the data and has the potential to improve streamflow forecasts in human-altered regions.

54 ENVIRONMENTAL SCIENCES↗

Translationally symmetric extended MHD via Hamiltonian reduction: Energy-Casimir equilibria

The Hamiltonian structure of ideal translationally symmetric extended MHD (XMHD) is obtained by employing a method of Hamiltonian reduction on the three-dimensional noncanonical Poisson bracket of XMHD. The existence of the continuous spatial translation symmetry allows the introduction of Clebsch-like forms for the magnetic and velocity fields. Upon employing the chain rule for functional derivatives, the 3D Poisson bracket is reduced to its symmetric counterpart. The sets of symmetric Hall, Inertial, and extended MHD Casimir invariants are identified, and used to obtain energy-Casimir variational principles for generalized XMHD equilibrium equations with arbitrary macroscopic flows. The obtained set of generalized equations is cast into Grad-Shafranov-Bernoulli (GSB) type, and special cases are investigated: static plasmas, equilibria with longitudinal flows only, and Hall MHD equilibria, where the electron inertia is neglected. The barotropic Hall MHD equilibrium equations are derived as a limiting case of the XMHD GSB system, and a numerically computed equilibrium configuration is presented that shows the separation of ion-flow from electro-magnetic surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A rapid embodied carbon assessment tool for priority materials

Embodied carbon limits within building materials are a driving factor in global trade, generating new research and analysis tools in industry. These product assessments, which require utilizing life-cycle assessment (LCA) across broad supply chains, can be expensive, time and data-intensive, and subject to significant variations. Existing methods and tools, such as specific environmental product declarations, typically do not capture these variations and dynamics in supply and manufacturing. Moreover, models and tools must enable stakeholders to assess customized supply chains and future scenarios. In this study, we present the Rapid Embodied Carbon Assessment and Target-setting for Emissions-intensive Materials (REDuCE) tool for building materials. We developed a tool that allows users to select production technologies, transportation mode and distances, concrete carbonation, fuel sources, and regional electricity mixes to supply customization for cement and concrete produced and consumed in California. We generated and integrated a material demand model using residential building stock projections. We provide the user with a wide range of mitigation alternatives through low-carbon production pathways, material use efficiency, transportation modes, and projected electricity grid mixes. In a case study application through four mitigation scenarios, we find emission savings up to 80% by maximizing user mitigation alternatives, primarily driven by reductions in material use intensities. This work represents a foundation for expanding LCA and embodied carbon tools to better enable stakeholders to rapidly and accurately assess customized supply chains while meeting trade requirements.

building materials↗

Inference of Chromosome-Length Haplotypes Using Genomic Data of Three or a Few More Single Gametes

Compared with genomic data of individual markers, haplotype data provide higher resolution for DNA variants, advancing our knowledge in genetics and evolution. Although many computational and experimental phasing methods have been developed for analyzing diploid genomes, it remains challenging to reconstruct chromosome-scale haplotypes at low cost, which constrains the utility of this valuable genetic resource. Gamete cells, the natural packaging of haploid complements, are ideal materials for phasing entire chromosomes because the majority of the haplotypic allele combinations has been preserved. Therefore, compared with the current diploid-based phasing methods, using haploid genomic data of single gametes may substantially reduce the complexity in inferring the donor’s chromosomal haplotypes. In this study, we developed the first easy-to-use R package, Hapi, for inferring chromosome-length haplotypes of individual diploid genomes with only a few gametes. Hapi outperformed other phasing methods when analyzing both simulated and real single gamete cell sequencing data sets. The results also suggested that chromosome-scale haplotypes may be inferred by using as few as three gametes, which has pushed the boundary to its possible limit. The single gamete cell sequencing technology allied with the cost-effective Hapi method will make large-scale haplotype-based genetic studies feasible and affordable, promoting the use of haplotype data in a wide range of research.

59 BASIC BIOLOGICAL SCIENCES↗