Search NASA⌕ Search

SEARCH · Search NASA

Results for “renewable variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Measuring changes in ambient noise levels from the installation and operation of a surge wave energy converter in the coastal ocean

Ecosystem impacts resulting from elevated underwater noise levels generated by anthropogenic activities in the coastal ocean are poorly understood and remain difficult to address as a result of a significant gap in knowledge for existing nearshore sound levels. Ambient noise is an important habitat component for marine mammals and fish that use sound for essential functions such as communication, navigation, and foraging. Questions surrounding the amplitudes, frequency distributions, and durations of noise emissions from renewable wave energy conversion (WEC) projects during their construction and operation present concerns for long-term consequences in marine habitats. Oregon’s dynamic nearshore environment presents significant challenges for passive acoustic monitoring that include flow noise contamination from wave orbital motions, turbulence from breaking surf, equipment burial, and fishing pressure from sport and commercial crabbers. This project included 2 techniques for passive acoustic data collection: 1) campaign style deployments of fixed hydrophone lander stations to capture temporal variations in noise levels and 2) a drifting hydrophone system to record spatial variations within the project site. The hydrophone lander deployments were effective and economically feasible for enabling robust temporal measurements of ambient noise levels in a variety of sea state conditions. Limiting factors for the fixed stations included 1) a flow shield mitigation strategy failure in the first deployment resulting in significant wideband data contamination and 2) flow noise contamination of the unshielded sensors restricting valuable analysis to frequencies above 500 Hz for subsequent deployments. Drifting hydrophone measurements were also effective and economically feasible (although logistically challenging in the beginning of the project due to vessel time constraints) providing a spatial distribution of sound levels, comparisons of noise levels in varying levels of vessel traffic during similar sea states, and reducing the frequencies contaminated by flow noise to f < 50 Hz by an effective drifting hydrophone system design strategy. Results from this project can still assist regulatory agencies and WEC developers in permitting and licensing, reducing project costs overall and assisting the economic development of the WEC industry, thus furthering the MHK energy industry and easing the U.S. reliance on foreign oil for energy production. Additionally, results from this project can be used to help inform coastal resource managers and regulatory agencies on existing baseline noise level variability and ecosystem health.

16 TIDAL AND WAVE POWER↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Nature of innovations affecting photovoltaic system costs

Innovations improve technology costs through various kinds of engineering advancements, including changes to materials choices and device or process designs. Understanding how these innovations relate to cost change can reveal aspects of the process of technology evolution, yet developing such understanding is often not possible with a strictly quantitative approach due to data limitations. In this paper we develop a hybrid quantitative-qualitative framework for relating specific innovations to cost change by using the variables in a quantitative technology cost change model as an organizing principle. We demonstrate this framework by applying it to the cost decline in photovoltaic (PV) systems over the last five decades. This framework generates new understanding of a set of innovations that contributed to PV modules’ sustained cost decline and the more modest trends observed in balance-of-system (BOS) costs. The results show the great diversity of innovations that affected PV costs, drawing on wide-ranging fields of expertise within scientific research and practice. We find that there are differences in the characteristics of innovations that reduced the cost of PV modules compared to innovations influencing BOS costs. Numerous module innovations reduced costs by advancing manufacturing tools and processes that improved material quality. Many BOS innovations reduced costs through a combination of component design changes, integration, automation, digitalization, and standardization. Overall, most innovations in our sample affected PV hardware. However, some also target ‘soft technologies’ such as task durations through innovations like fast-track permitting, which require improved collaboration and process streamlining. This framework also provides insight into the nature of knowledge spillovers between technologies. Both module and BOS hardware innovations show the benefits of PV’s position within an ‘ecosystem’ of continuously advancing technologies in many industries, in particular semiconductors and electronics, and also point to the importance of public institutions for accelerating testing, permitting, and training.

14 SOLAR ENERGY↗

Marine Hydrokinetic Energy Site Identification and Ranking Methodology Part I: Wave Energy

Marine hydrokinetic energy is a promising and growing piece of the renewable energy sector that offers high predictability and additional energy sources for a diversified energy economy. This report investigates the market opportunities for wave energy along the U.S. coastlines. It is part one of a two-part investigation into the United State's two largest marine hydrokinetic resources (wave and tidal). Wave energy technology is still an emerging form of renewable energy for which large-scale, grid-connected project costs are currently poorly defined. Ideally, device designers would like to know the resource conditions at economical project sites so they can optimize device designs. On the other hand, project developers need detailed device cost data to identify sites where projects are economical. That is, device design and siting are, to some extent, a coupled problem. This work describes a methodology for identifying likely deployment locations based on a set of criteria that wave energy experts in industry, academia, and national laboratories agree are likely to be important factors for all technology types. This work groups the data for the six criteria into 'locales' that are defined as the smaller of either the local transmission grid or a state boundary. The former applies to U.S. islands (e.g., Hawaii, American Samoa) and rural villages (e.g., in Alaska); the latter applies to states in the contiguous United States. These data are then scored from 0 to 10 according to scoring functions that were developed with input from wave energy industry and academic experts. The scores are aggregated using a simple product method that includes a weighting factor for each criterion. This work presents two weighting scenarios: a long-term scenario that does not include energy price (weighted zero) and a near term scenario that includes energy price. The aggregated scores are then used to produce ranked lists of likely deployment locales. In both scenarios, Hawaii and the Pacific Northwest (northern California, Oregon, and Washington) rank at the top of the lists. Hawaii ranks highest in the near-term scenario because it has high energy costs. In the long-term scenario, Oregon ranks highest because it has a large market and an energetic resource. Several East Coast states and Puerto Rico are also identified as potential wave energy deployment sites if technological innovations make it possible to efficiently generate electricity from the modest resource there. There are also several small-market sites in Alaska and U.S. Pacific Islands that rank particularly well in the near-term analysis due to their high energy prices. These locations may represent opportunities to demonstrate economical wave energy conversion as a stepping-stone to larger markets. Several factors that will affect wave project costs and siting have not been considered here -- including permitting constraints, conflicting use, seasonal resource variability, extreme event likelihood, and distance to ports -- because consistent data are unavailable or technology-independent scoring could not be identified. As the industry continues to mature and converge around a subset of device archetypes with well-defined costs, more precise investigations of project siting that include these factors will be possible. For now, these results provide a high-level guide pointing to the regions where markets and resource will one day support commercial wave energy projects.

16 TIDAL AND WAVE POWER↗

Case Study: Hybrid Carbon Conversion Using Low-Carbon Energy Sources in Coal-Producing States

The demand for more carbon efficient power sources and a decrease in natural gas prices has decreased the desire for coal power. This decrease in demand has led to massive job losses in coal mining regions over the past decade. The purpose of this project is to develop a hybrid energy system utilizing both a coal power plant and advanced reactor, which is competitive with natural gas by improving on profitability and decreasing carbon emissions. This report details the problem with a summary of the impact on the coal industry and the availability of renewable energy sources in the Appalachian region. Because of the geography of the region, variable renewable energy sources are not available without significant size and siting restrictions. However, biomass in the form of wood waste is abundant and can be used as a carbon neutral energy source. Combining biomass and coal processing, in addition to thermal power plants, can increase system profits and efficiency by providing peaking power and conversion opportunities for secondary markets. The electric load is based on publicly available demand data from Appalachian Power, which services the western Virginia and southern West Virginia in the Appalachian region. The demand information is combined by service, normalized, and scaled to an average demand of 1000 kW, which will be the basis for sizing the hybrid energy system. A traditional screening curve analysis for a coal plant and advanced reactor shows that the least cost design varies significantly based on the assumed discount rate and capital recovery period. An optimization program to size the design in TEAL based on the load curve gives 10 optimal designs, all with a negative resulting net present value (NPV) and a coal plant capacity of less than 15%. Including profits from selling captured carbon at a flat rate results in a positive NPV; however, the coal capacity factor only increases to about 40%. There are limitations with this optimization as well since the price of CO2 is likely to decrease as more is sold to the conversion market. The suggested design will combine coal power, an advanced reactor, and coal and biomass coprocessing to produce a variety of products that can be sold to the conversion market while increasing system efficiency. The analysis of conversion pathways for coal and biomass reveals that multiple options will need to be included in the analysis to produce the optimal system design. Three systems will be optimized and compared to determine the best design based on the figures of merit of total NPV and cost of carbon avoided. The first system will include a coal power plant and an advanced reactor that will sell electricity to the grid to meet demand and sell captured carbon to the conversion market. The second system adds a high-temperature steam electrolysis plant, which will utilize electricity during times of low demand to produce hydrogen and sell it to the conversion market. The third system adds biomass and coal processing with options for hydrocarbon oils, syngas to be produced for the conversion market, and electricity generation to power components within the system or provide peaking power. This analysis will be based on a new approach that combines traditional screening curve methods with a dispatch algorithm that optimizes the system based on the opportunity cost of different production options. The resulting optimization algorithm should provide results with less processing time than HERON’s decision tree method. The results from this analysis will determine an optimal design and reinforce the benefits of coal power when used in a hybrid energy system. The initial results show that the addition of a secondary market for carbon sales could result in a positive NPV and increases the capacity factor of the coal plant as compared to a design with only sales to the electricity market. The addition of more markets and additional coal consumption from biomass coprocessing could increase NPV further, replace carbon in other markets through the sale of biomass-derived hydrocarbons, and demonstrate the value of coal power technology.

01 COAL, LIGNITE, AND PEAT↗

Method to produce durable pellets at lower energy consumption using high moisture corn stover and a corn starch binder in a flat die pellet mill

Biomass from plants can serve as an alternative renewable energy resources for energy production. Low densities of 40–60 kg/m3 for ground lignocellulosic biomass like corn stover limit its operation for energy purposes. The common drawbacks are inefficient transportation, a bigger storage foot print, and handling problems. Densification of biomass using pellet mill helps to overcome these limitations. This study helps to understand the effect of binder on high moisture biomass with a focus on the quality (density and durability), the pelleting efficiency and the specific energy consumption of its pelleting process. Raw corn stover was pelleted at high moisture of 33% (w.b.) at both varying preheating temperatures and binder percentage. The die speed of the pellet mill was set at 60Hz. The pellets produced were analyzed and showed higher moisture content. They were further dried in a laboratory oven at 70°C for 3-4 hr bringing the pellet moisture to <9%. The dried pellets were evaluated for their physical properties like unit, bulk and tapped density, and durability. Furthermore, the results indicated increasing the binder percentage to 4% improved the physical properties of the pellets and reduced the specific energy consumption. Higher binder addition of 4% reduced the feedstock moisture loss during pelleting to <4%, which can be due reduced residence time of the material in the die. On the other hand the physical properties like density and durability improved significantly with binder addition. At 4% binder and 33% feedstock moisture content, the bulk density and durability values observed were >510 kg/m3 and >98% and the percent fines generation has reduced to <3%. Also at these conditions the specific energy consumption was reduced by about 30-40% compared no binder pelleting test.

09 BIOMASS FUELS↗

An Analytical Impact Assessment Framework for Wildlife to Inform the Siting and Permitting of Wind Energy Facilities

In the United States overall electrical generation capacity is expected to increase by 10-25 gigawatts (GW) per year to meet increases in demand. Wind energy is a key component of state and federal renewable energy standards, and central to the Department of Energy’s 20% by 2030 wind production goals. Increased wind energy development may present increased resource conflict with avian wildlife, and environmental permitting has been identified as a potential obstacle to expansion in the sector. ICF developed an analytical framework to help applicants and agencies examine potential impacts in support of facility siting and permitting. A key objective of our work was to develop a framework that is scalable from the local to the national level, and one that is generalizable across the different scales at which biological communities operate – from local influences to meta-populations. The intent was to allow natural resource managers to estimate the cumulative impacts of turbine strikes and habitat changes on long-term population performance in the context of a species demography, genetic potential, and life history. We developed three types of models based on our literature review and participation in the scientific review processes. First, the conceptual model was developed as a general description of the analytical framework. Second, we developed the analytical framework based on the relationships between concepts, and the functions presented in the scientific literature. Third, we constructed an application of the model by parameterizing the framework using data from and relevant to the Altamont Pass Wind Resource Area (APWRA), and an existing golden eagle population model. We developed managed source code, database create statements, and written documentation to allow for the reproduction of each phase of the analysis. ICF identified a potential template adaptive management system in the form of the US Fish & Wildlife Service (USFWS) Adaptive Harvest Management (AHM) program, and developed recommendations for the structure and function of a similar wind-facility related program. We provided a straw-man implementation of the analytical framework based on assumptions for APWRA-wide golden eagle fatalities, and presented a statistical examination of the model performance. APWRA-wide fatality rates appear substantial at all scales examined from the local APWRA population to the Bird Conservation Region. Documented fatality rates significantly influenced population performance in terms of non-territorial non-breeding birds. Breeder, Juvenile, Subadult, and Adult abundance were mostly unaffected by Baseline APWRA-wide fatality rates. However, increased variability in fatality rates would likely have impacts on long-term population performance, and would result in a substantially larger loss of resources. We developed four recommendations for future study. First, we recommend establishment of concept experts through the existing system of non-profits, regulatory agencies, academia, and industry in the wind energy sector. Second, we recommend the development of a central or distributed shared data repository, and establish guidelines for data sharing and transparency. Third, we recommend development a forum and process for model selection at the local and national level. Last, we recommend experimental implementation of the prescribed system at broader scales, and refinement the expectations for modeling and adaptive management.

54 ENVIRONMENTAL SCIENCES↗

Dataset: "Widespread Drought-driven Declines in Streamflows and Water quality in the Upper Colorado River Basin (1998-2022)"

This data package contains the associated data and scripts for Nagamoto, E., Ombadi, M., Ciulla, F. et al. Widespread drought-driven declines in streamflows and water quality in the Upper Colorado River Basin during 1998-2022. Commun Earth Environ 7, 734 (2026). https://doi.org/10.1038/s43247-026-03890-5. This purpose of this study was to investigate the impact of the 21st century drought on water quantity and quality at catchments throughout the Upper Colorado River Basin (UCRB). We used stream flow, water temperature, specific conductance, air temperature, precipitation, and catchment attribute data for over 200 sites in the UCRB, collected from the National Water Information System using Basin3D (Varadharajan, 2023), GAGESII (Falcone, 2010), and the Google Earth Engine. We identified years of severe drought between 1998 and 2022 using the Standardized Precipitation Evaporation Index (SPEI), then calculated the relative change percentage of the stream flow, water temperature, and specific conductance from drought versus non-drought years. We used the attribute information from GAGESII to investigate what physical traits of catchments are associated streamflow vulnerability (greater relative change) or resilience to drought. We used land cover data from the National Land Cover Database (USGS, 2024) to assess any changes to physical attributes that may not be represented in the static attributes information in GAGESII. To increase data availability, we modeled stream temperature using methods from Willard, 2023. While the study period is water years 1998 to 2022, the raw water quantity and quality data extends to 1950 and the meteorological data extends to 1980. The data and code can be downloaded via the UCRB_drought.zip. Within the zip, the files are organized as follows: - INPUTS: Contains all input data used in UCRB_Drought_Workflow.ipynb - OUTPUTS: Contains all intermediate data created from UCRB_Drought_Workflow.ipynb as well as final products including the calculated Standardized Evapotranspiration Index (SPEI) - climatic_variables: The code used to collect meteorologic data from Google Earth Engine - feature_importance: The code used for the catchment attributes analysis - preprocessing: Code used in UCRB_Drought_Workflow_Preprocessing.ipynb - pyeto: Code used in UCRB_Drought_Workflow_Preprocessing.ipynb - calculations: Code used in UCRB_Drought_Workflow_Impacts.ipynb - plotting: Code used in UCRB_Drought_Workflow_Impacts.ipynb - README.md - UCRB_Drought_Workflow_Preprocessing.ipynb: The code used to prep raw data for the analysis - UCRB_Drought_Workflow_Impact.ipynb: The code which uses the prepped raw data for analysis, and plots all figures - requirements_ucrb-drought_v2.yml: The requirements file to create a virtual environment and Jupyter Lab kernel to run the code The INPUTS folder is organized into the following major directories and sub-directories. The "RDC_WT_SC_RAW" folder contains raw data for streamflow, water temperature, and specific conductance in a ".h5" file. The "NLCD_RAW" folder contains ".csv" files with annual land cover percentages for counties within the UCRB. The "MET_RAW" folder contains a ".csv" file with monthly meteorological data (air temperature and precipitation) for the sites in the UCRB which was obtained from code in the climatic_variables folder. The "GAGESII" folder contains ".csv" files with physical catchment attribute variables for catchments across the country. The "WT_LSTM_data" folder contains ".csv" files with calculated WT (Willard, 2023) and the associated RMSEs. The "Upper_Colorado_River_Basin_Boundary" folder contains geographic data including a shapefile for plotting in the UCRB_Drought_Workflow.ipynb. The "RESERVOIRS_RAW" folder contains ".csv" files for each reservoir in the UCRB with daily reservoir storage. There are also two files in the INPUTS folder that have combined reservoir storage data and reservoir metadata. The OUTPUTS folder is organized into the following major directories and sub-directories. The "RDC_WT_SC_data" folder contains a folder "Water_year" with the associated cleaned data, metadata, and data availability information in ".csv" files, a folder "Median_Relchange" with the relative change comparing drought to non-drought years in ".csv" files, and a folder "Peak95_Min5_Relchange" that has ".csv" files for the relative change in peak (95th %) and minimum (5th %) variables. The "NLCD_data" folder contains the difference in land cover from the beginning to end of the study period and the percentage of the county that is within UCRB bounds can be found in Nagamoto et al (2025)). The "MET_data" folder contains separated monthly air temperature and precipitation data and the calculated PET in ".csv" files. The "SPEI_data" folder contains ".csv" files with calculated SPEI values (one restricted to the study period and the other with information from the entire MET data period). The "Paper_Tables" folder contains two ".csv" files containing site information and data availability and information about the GAGESII trait aggregated categories. The base directory includes the file “flmd.csv” for a list and description of all files and the file “dd.csv” for data dictionaries. Scripts for preprocessing, analysis, and figure generation are located in the associated GitHub repository found at [https://github.com/iNAIADS/drought-impacts/tree/develop/UCRB-drought]. UPDATE 1: Title and code file updated to match submitted manuscript 10-15-2025. UPDATE 2: Code and data files updated to match revised manuscript 3-4-2026. UPDATE 3: Code and data files updated to match revised manuscript 6-7-2026. ** NOTE: DD and FLMD have not been updated yet. UPDATE 4: Added associated Manuscript information and DD and FLMD have been updated. To cite this code, please use the following BibTeX: @misc{nagamoto2025drought, author = {Emily Nagamoto and Fabio Ciulla and Mohammad Ombadi and Jared Willard and Rosemary Carroll and Charuleka Varadharajan}, title = {Dataset: "Widespread Drought-driven Declines in Streamflows and Water quality in the Upper Colorado River Basin (1998-2022)"}, year = {2025}, doi = {10.15485/2551894}, publisher = {ESS-DIVE Repository}, url = {https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2551894} }

54 ENVIRONMENTAL SCIENCES↗

Variability in Wind Energy Generation across the Contiguous United States

ERA5 provides high-resolution, high-quality hourly wind speeds at 100 m and is a unique resource for quantifying temporal variability in likely wind-derived power production across the United States. Gross capacity factors (CF) in seven independent system operators (ISOs) are estimated using the location and rated power of each wind turbine, a simplified power curve, and ERA5 output from 1979 to 2018. Excluding the California ISO, the marginal probability of a calm (zero power production) is less than 0.1 in any ERA5 grid cell. When a calm occurs, the mean co-occurrence across wind-turbine-containing grid cells ranges from 0.38 to 0.39 for ISOs in the Midwest and central plains [Midcontinent (or Midwest) ISO (MISO), Southwest Power Pool (SPP), and the Electric Reliability Council of Texas (ERCOT) region], increasing to 0.54–0.58 for ISOs in the eastern United States [Pennsylvania–New Jersey–Maryland interconnection (PJM), New York ISO (NYISO), and New England ISO (NEISO)]. Periods with low gross CF have a median duration of ≤6 h, except in California, and are most likely during summer. Additionally, gross CF exhibit highest variance at periods of 1 day in ERCOT and SPP; on synoptic scales in MISO, NEISO, and NYISO; and on interannual time scales in PJM. This implies differences in optimal strategies for ensuring resilience of supply. Theoretical scenarios show adding wind energy capacity near existing wind farms is advantageous even in areas with high existing installed capacity (IC), while expanding into areas with lower IC is more beneficial to reducing ramps and the probability of gross CF falling below 20%. These results emphasize the benefits of large balancing areas and aggregation in reducing wind power variability and the likelihood of wind droughts.

17 WIND ENERGY↗

FORCE-DISPATCHES Integration - Initial Demonstration

Integrated energy systems (IES) combine, in mutually beneficial ways, power from variable renewable energy sources and nuclear power plants (NPP) to improve economic viability under uncertain market and weather conditions. The open-source Framework for Optimization of Resources and Economics (FORCE) tool suite, developed at Idaho National Laboratory (INL), has enabled comprehensive modeling and simulation of IES. The capabilities within FORCE include grid portfolio optimization through the Holistic Energy Resource Optimization Network (HERON) and the transient process model analysis library HYBRID, among others. Continuous efforts and investments from the IES programs have been made to expand and improve the versatility of the FORCE toolset in fiscal year 2022. Code-coupling and cross-tool communication have been important methods for improving this versatility. This report focuses on an additional workflow in the HERON tool for capacity and dispatch stochastic optimization through integration with the external tool Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES). DISPATCHES was primarily developed by the National Energy Technology Laboratory, in collaboration with other national laboratories, which included INL, universities, and industry partners. It is coupled to a library of algebraic models for specific plant components, and to a framework for stochastic optimization different from that provided in the current Risk Analysis Virtual Environment (RAVEN)-running-RAVEN algorithm in HERON. HERON currently conducts stochastic optimization via an outer-inner loop: it optimizes over variable capacity on the outer loop, and at each step within the capacity parameter space, conducts an inner optimization over scenarios (of market signals, demand, and/or weather patterns) and hourly dispatch throughout a user-specified number of years. On the other hand, DISPATCHES conducts stochastic optimization via an “all-at-once” strategy in which capacity variables are optimized at the same level as dispatch variables, as all scenarios are considered at once. The latter method works especially well for projects of limited size and project length, as the necessary computational power and memory increases with the number of variables and scenarios. The new capability to use the DISPATCHES workflow in HERON enhances standalone simulations by leveraging FORCE tools—namely, the economic metrics from the Tool for Economic Analysis (TEAL) and reduced-order model (ROM) sampling from RAVEN. The initial demonstration of the DISPATCHES workflow simulates an existing nuclear-case flowsheet within the DISPATCHES repository—this models a NPP with a secondary revenue stream for hydrogen production. Electrical output from the plant is converted to hydrogen via a proton-exchange membrane (PEM) electrolyzer, hydrogen tanks are used for storage, and an additional turbine is added for hydrogen combustion. Continued work regarding this FORCE-DISPATCHES integration will include automatic generation of DISPATCHES models from HERON inputs, offering analysts the option of using either the RAVEN-runsRAVEN or DISPATCHES workflow to solve technoeconomic optimization problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bio-project “derisking” through development of systematic methodologies and frameworks for risk assessment

One of the primary hindrances to producing a viable, sustainable domestic biomass industry for renewable biofuels, bio-products and bio-power is the lack of understanding and quantification of the risks associated with both the biomass supply chain and preprocessing and conversion technologies. Currently a consistent method for assessing, comparing, and quantifying risks in biomass supply chains does not exist, creating a major investment barrier to bioenergy projects in the U.S. The lack of a standardized approach has resulted in bioenergy stakeholders independently using inconsistent approaches and evaluation criteria, leading to unreliable and incomparable assessments of risks and financing barriers to bio-project development. Along with the challenges of inconsistent risk assessment for supply chain risk, technology specific risks based on variability in biomass properties are not fully understood and can pose significant unforeseen challenges for bioenergy projects. In many cases these properties have not yet been identified and the impacts on the proposed technology and products unquantified. This is particularly challenging for emerging preprocessing and conversion technologies. Without a firm understanding of the preprocessing/conversion technology-specific critical properties, the risk of a proposed bio-project cannot be fully evaluated. To address inconsistent risk evaluation in the biomass supply chain supporting project financing, a Biomass Supply Chain Risk Standards (BSCRS) framework was developed. The BSCRS framework includes a comprehensive list of known and perceived risks (Risk Indicators) to the supply chain developed through 100’s of interviews with bioenergy industry experts spanning from feedstock growers and suppliers to representatives from the financial sector. These risks have been organized into a manageable hierarchy of Risk Categories and Risk Factors that can be practically assessed. This BSCRS framework also provides mitigation strategies for multiple Risk Indicators from best available industry practices and research findings. Additionally, a risk quantification methodology for each Risk Factor, Risk Category, and the bio-project as a whole was developed to enable capital markets to assess feedstock risk more efficiently and more accurately. Multiple case studies representing existing bio-projects have been used to evaluate and verify the BSCRS framework and scoring methodology. To address technological risk along with the supply chain risk captured in the developed BSCRS framework, this work also focuses on development of a systematic criticality assessment tool using well-accepted, quantitative risk analysis methods to evaluate bioenergy feedstock critical properties impacting system unit operations. The proposed Failure Mode and Effect Analysis (FMEA) approach uses a team of subject area experts (SAEs) for each targeted unit operation within a system. Collectively, the team will develop and use a quantitative scoring system to assess the material attributes, process parameters, and quality attributes for key unit operations that have already been identified. The FMEA process generates Risk Priority Numbers (RPNs) for the various failures and predominant causes for each material/process unit/product combination resulting in a semi-quantitative, standardized methodology for assessing technological risk and biomass properties contributing to that risk.

09 BIOMASS FUELS↗

Ecovoltaic solar energy development can promote grassland bird communities

Ecologically informed photovoltaic (PV) developments that co-prioritize PV electricity generation with ecosystem function (‘ecovoltaics’) have emerged as a promising land sharing strategy to minimize ecological conflicts associated with PV solar energy development. While habitat-focused ecovoltaic designs can conceptually benefit biodiversity by offsetting or enhancing impacts of PV development, foundational field research is needed to examine how wildlife respond to these novel ecosystems. We conducted passive acoustic monitoring (PAM) in 2023 and 2024 at 13 solar facilities and paired control sites to investigate avian community responses to ecovoltaic facilities in the Midwestern United States. Compared to control sites (row crop agricultural fields), we found that ecovoltaic sites supported more grassland bird species throughout a 17-week monitoring period between May and September. Grassland bird communities on ecovoltaic sites were also more stable than on agricultural controls, as measured by the Jaccard dissimilarity index. We also used PAM-based weekly species occurrences in an occupancy-modelling framework to investigate the influence of PV development and other landscape variables on grassland bird occupancy. 10 out of 13 modelled grassland bird species had greater predicted occupancy probabilities (ψ) on PV sites than control sites. Synthesis and applications. Our findings suggest that properly sited and developed ecovoltaic solar facilities in human altered landscapes can improve habitat for birds and other wildlife, but further research is needed to understand which species may benefit most from these novel ecosystems.

14 SOLAR ENERGY↗

Species-specific acoustic responses by bats to ultrasonic stimuli used for reducing bat-wind turbine interactions

An unintended consequence of wind energy generation is bat fatalities caused by wind turbine blade strikes. One potential approach to reduce collision risk is to use ultrasound to create an uncomfortable or disorienting airspace around wind turbine blades. Ultrasonic deterrents (UDs) have produced mixed results in experimental field studies at commercial wind energy facilities, with effectiveness varying by species and location. It is possible that some species can alter their normal echolocation characteristics to counter the signal of UDs. Our broad objective was to maximize the effectiveness of a UD by comparing changes in echolocation characteristics during three UD frequency emissions among species, between seasons, and between sex. We hypothesized that UD emissions with frequencies most similar to each species’ echolocation characteristics would be more likely to alter the bats’ echolocation, and bat responses would vary between seasons and sex for each species. We released wild-captured bats into a 60 m × 10 m × 4.4 m (length × width × height) flight cage located in San Marcos, Texas, USA, from July to October 2020 and March to May 2021 and monitored echolocation frequencies with ultrasonic microphones. We conducted trials on Brazilian free-tailed bats ( Tadarida brasiliensis ; n = 54), cave myotis ( Myotis velifer ; n = 44), red bats ( Lasiurus blossevilli , Lasiurus borealis ; n = 41), evening bats ( Nycticeius humeralis ; n = 32), and tricolored bats ( Perimyotis subflavus ; n = 8). We found that species with high-frequency echolocation calls altered their echolocation signatures more commonly during high-frequency UD emissions, whereas low-frequency bats altered their echolocation signatures more commonly during low-frequency UD emissions. Additionally, echolocation responses varied between seasons and sexes for several species. Variations in responses may be dependent on species migratory status, differences in mating behavior and mating season, hormonal differences between sexes and seasons, and/or constraints on echolocation adaptability. Our results offer insights into the variable effectiveness of UDs at reducing bat fatalities at wind turbines and provide information for potential adjustments to UDs for improved success.

17 WIND ENERGY↗

Evaluation of Hybrid FPOG Applications in Regulated and Deregulated Markets Using HERON

Recent changes in the U.S. energy market, such as low natural gas prices and increased electricity production for variable renewable energy (VRE) sources, have led to an economic crisis for existing light-water reactor (LWR) nuclear power plants (NPP). Many owners and operators of LWRs have elected to decommission these plants rather than continue using them as consistent sources of clean baseload power. This has led to exploration of various possibilities to increase the economic viability of these units, including market restructuring to monetize benefits LWRs already provide to the grid through ancillary markets, load following and economic dispatch, and possible integration of secondary systems directly to the NPP for production of additional products through technologies such as hydrogen electrolysis or water desalination. Previous studies have considered the technologies associated with these Integrated Energy Systems (IES) activities, and the analysis of markets for these secondary products. To analyze the economic viability of various system configurations including IES, especially given the uncertainty surrounding load demand, electricity prices, and the availability of VRE resources, the stochastic technoeconomic analysis package HERON (Heuristic Energy Resource Optimization Network) was released earlier this year as an extension of the risk analysis framework RAVEN (Risk Analysis Virtual Environment). HERON focuses foremost on making the complex uncertainty quantification analysis tools approachable for energy systems analysts, also providing general dispatch optimization algorithms for those workflows. HERON continues to be improved and tested as a significant part of the IES viability analyses performed in this work. HERON is not a capacity expansion model. To consider market and grid energy system development in a variety of scenarios, HERON is best used in coupling with modelling tools such as US-REGEN, which sacrifice some of the uncertainty analysis and resolution of HERON's modelling for the ability to efficiently predict the change in the grid energy system's profile due to economic drivers over decades. HERON can then use this information to explore the economic viability of introducing changes to the predicted outcomes, such as the introduction of an IES. In this work, experts at EPRI using US-REGEN provide six projection scenarios for use in HERON stochastic technoeconomic analysis (STEA) in considering the options available for increasing LWR economic viability through introduction of a hydrogen-centric IES using a high-temperature steam electrolysis plant (HTSE), hydrogen storage, and a constant-rate contracted hydrogen consumer. The results obtained are differential in nature; they do not report expected profits for any configuration, but rather report on the possible increase in the NPV of a configuration with respect to a baseline no-IES configuration. Due to the uncertainty captured in the variable net load of the systems, there is likewise uncertainty in the mean values reported. We consider this viability both in terms of a regulated market, where the energy producers and IES are owned and operated by single entity, as well as a deregulated market, where the IES chooses its bid for electricity generation and is then dispatched by the grid system operator. Results indicate that for deregulated markets, the inclusion of the IES is often statistically beneficial. This is especially true in policies that are not favorable towards nuclear, as nuclear is less often dispatched and is forced to deal with frequent idle capacity. In the nominal case as well as the case of carbon tax policies, inclusion of the IES clearly benefited the economic performance of the NPP. In the regulated case, however, there was a trend towards minimizing the IES, likely due to the optimal sizing performed by US-REGEN of the NPP within the system as well as the lack of penalty for idle capacity at the NPP in the regulated market analyses.

99 GENERAL AND MISCELLANEOUS↗

Modular Undersea Compressed Air Energy Storage (UCAES) System

This project has been devoted to the design, optimization, and cost analysis of a unique power plant with integral energy storage. The proposed facility combines a novel underwater compressed air energy storage (UCAES) system with a customized gas turbine generator, providing exceptional power management and overall efficiency. Unlike conventional CAES, opportunities for underwater storage are plentiful and proximal to the power grid. The UCAES system provides coastal and island communities a practical means for managing the volatility of large-scale wind and solar power resources. The result is higher renewable energy absorption and improved electrical reliability with reduced fossil fuel consumption. The UCAES power plant is composed of three major subsystems: The underwater air containment system (ACS), the air transport pipe (ATP), and the land-based power conversion system (PCS). The underwater ACS is made up of modular concrete shell units, structurally optimized for minimal material usage while employing conventional production methods and equipment. Each shell is designed to receive and control loose fill or gravel, serving as the ballast. The static nature of the final structures make them an asset to marine habitats and includes features intended to permit safe and cost-effective deployment. The ATP Connects the ACS modules to each other and to the on-land power conversion system and utilizes high density polyethylene (HDPE) pipe for low cost and long life. The PCS Houses the turbine-generator ‘expander modules’, with peak capacity of 12.3 MWe each, engineered from existing gas turbine equipment and includes electrically driven commercial 3-stage intercooled centrifugal compressors, each nominally drawing 6.6 MWe when matching the turbine flow requirements. The subsystems listed above are designed with the intent to serve as building-blocks to achieve a peak power output rating in the 40 to 120 MWe range, with 0.25 to 4 hours of energy storage capacity. The modular facility with integral energy storage provides some remarkable transient maneuvers and load-following features unachievable by competing technologies. The system can operate as a dispatchable power plant with a fuel-to-electric efficiency over 41%; substantially better that the average existing Hawaiian peak power generation assets. Optimal efficiency can be maintained while load-following due to modular PCS design and is operable with a range of liquid or gaseous fuels while meeting the most stringent California (CARB) emission standards. The system can operate as a peaking energy plant in discharge mode. Power ramp-up equivalent to 215% of continuous load rating within 1 second accomplished by simply turning off the electric compressor(s). Contrarily, the system can offer energy absorption during periods of grid surplus generation. The electric compressors may be sequenced on to absorb power within seconds. More moderate transitions are easily achieved with standard compressor control functions. The system offers unique features as compared to energy storage systems. ‘Round-trip efficiency’, as calculated by industry standard methods, is in the 90% range. The PCS equipment has a mean-time between overhauls of 80,000 hours, with maintenance costs of less than $0.005/kW-hr of electricity delivered. The underwater ACS structures and piping employ materials and designs specified to achieve a 75 year life. With the underwater containment modules qualified as a marine habitat, there would be no decommissioning costs. In conjunction with the engineering work invested in the design of the UCAES power plant, Brayton Energy has employed a team of manufacturing specialists, marine construction engineers, and power industry experts to create a comprehensive economic model that captures the many site-related variables and configuration options. The cost results and methodology have been validated by suppliers, engineers, and deployment specialists through a detailed case study on Hawaii. While creation of the parametric cost model was based on inputs specific to Hawaii, the proposed construction and deployment steps were chosen to be general enough to allow extrapolation across locations world-wide. Analysis of the proposed system shows it to be a viable option and addresses the principal challenges described by the Department of Energy by offering competitive costs, validated safety and reliability, consideration of the regulatory environment, and utilization of industry accepted practices and equipment. The UCAES system is recommended for immediate consideration in Hawaii. Estimation of time to complete planning, design, and construction of the facility is anticipated to take 3 to 5 years. Other coastal and island communities world-wide should realize similar benefits; as the results presented in this report are considered generally transferable to other locations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Unit-Level Changes in Operations with Increased SPP Wind from EPRI/LCG Balancing Study

Wind power development in the United States is outpacing previous estimates for many regions, particularly those with good wind resources. The pace of wind power deployment may soon outstrip regional capabilities to provide transmission and integration services to achieve the most economic power system operation. Conversely, regions such as the Southeastern United States do not have good wind resources and will have difficulty meeting proposed federal Renewable Portfolio Standards with local supply. There is a growing need to explore innovative solutions for collaborating between regions to achieve the least cost solution for meeting such a renewable energy mandate. The Department of Energy funded the project 'Integrating Midwest Wind Energy into Southeast Electricity Markets' to be led by EPRI in coordination with the main authorities for the regions: SPP, Entergy, TVA, Southern Company and OPC. EPRI utilized several subcontractors for the project including LCG, the developers of the model UPLAN. The study aims to evaluate the operating cost benefits of coordination of scheduling and balancing for Southwest Power Pool (SPP) wind transfers to Southeastern Electric Reliability Council (SERC) Balancing Authorities (BAs). The primary objective of this project is to analyze the benefits of regional cooperation for integrating mid-western wind energy into southeast electricity markets. Scenarios were defined, modeled and investigated to address production variability and uncertainty and the associated balancing of large quantities of wind power in SPP and delivery to energy markets in the southern regions of the SERC. DOE funded Oak Ridge National Laboratory to provide additional support to the project, including a review of results and any side analysis that may provide additional insight. This report is a unit-by-unit analysis of changes in operations due to the different scenarios used in the overall study. It focuses on the change in capacity factors and the number of start-ups required for each unit since those criteria summarize key aspects of plant operations, how often are they called upon and how much do they operate. The primary analysis of the overall project is based on security-constrained unit commitment (SCUC) and economic dispatch (SCED) simulations of the SPP-SERC regions as modeled for the year 2022. The SCUC/SCED models utilized for the project were developed through extensive consultation with the project utility partners, to ensure the various regions and operational practices are represented as best as possible in the model. SPP, Entergy, Oglethorpe Power Company (OPC), Southern Company, and the Tennessee Valley Authority (TVA) actively participated in the project providing input data for the models and review of simulation results and conclusions. While other SERC utility systems are modeled, the listed SERC utilities were explicitly included as active participants in the project due to the size of their load and relative proximity to SPP for importing wind energy.

17 WIND ENERGY↗

Evaluation of Hydrogen Production Feasibility for a Light Water Reactor in the Midwest

Increased electricity production from renewable energy resources coupled with low natural gas prices has caused existing light-water reactor (LWRs) to experience ever diminishing returns from the electricity market. Via partnership among Idaho National Laboratory (INL), The National Renewable Energy Laboratory (NREL), Argonne National Laboratory (ANL), Exelon, and Fuel Cell Energy a techno-economic analysis on the viability of retrofitting existing pressurized water reactors (PWRs) to produce hydrogen (H2) via high temperature steam electrolysis (HTSE) has been conducted. Such integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long-term. To accommodate such an integration, a detailed analysis of HTSE process operation, requirements, and flexibility was conducted. Technical analysis includes proposed nuclear system control scheme modifications to allow dynamic operation of the HTSE via both thermal and electrical connection to the nuclear plant. High fidelity Modelica simulations showcase the viability of such control schemes. However, due to limited knowledge of solid oxide fuel cell (SOFC) stack degradation due to thermal gradients; thermal cycling of the HTSE was not included. Therefore, the control schemes proposed are only utilized to re-distribute steam at startup and only the portion of electricity utilized in the electrolyzers is cycled. From the detailed analysis of the nuclear integration and the HTSE process design, a comprehensive cost estimation was conducted in the APEA and H2A models to elucidate capital and operational costs associated with the production, compression, and distribution of hydrogen from a nuclear facility. Alongside this costing analysis, market analyses were conducted by NREL and ANL on the electric and hydrogen markets respectively in the PJM interconnect. Utilizing the electricity data market projections in the PJM interconnect from NREL and hydrogen demand/pricing projections from ANL a five variable sweep over component capacities, discount rates, and hydrogen pricing was completed using the stochastic framework RAVEN (Risk Analysis Virtual ENVironment) through its resource dispatch plugin HERON (Heuristic Energy Resource Optimization Network). Each combination of variables was evaluated stochastically four times over a seventeen year timespan from 2026-2042 (inclusive) to determine the most economically advantageous solution. Following the five variable sweep an optimization was conducted about the best sweep point to determine optimal component sizing and setpoints. Results suggest positive gain is achievable at all projected hydrogen market pricing levels and at all discount rates. However, exact component sizing and net returns vary based on these values and if incorrect sizing is selected; major net losses can occur. The optimal result occurred with set points as follows: high hydrogen prices, the largest possible HTSE unit in the sweep set at 7.47 kg/sec [645.4 tpd], a contractual hydrogen market agreement 7.29 kg/sec [629.8 tpd], and a hydrogen storage size 115,188 kg. The analysis suggested that with a discount rate of 8%, a ΔNPV = 1.2 billion over the seventeen year span can be achieved. The results illuminate that by operating in multiple markets the nuclear facility is capable of avoiding sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted in this report is a differential cash flow analysis and as such does not present profit levels. Instead it highlights the net benefit between building and competing in the hydrogen market utilizing nuclear facilities and conducting business as usual in the electricity markets. Additionally, results presented in this report exhibit conservatism due to four key assumptions: Given the limited knowledge on SOFC stack degradation due to thermal gradients the high temperature steam electrolysis plant is not allowed to thermally cycle. This limitation decreases electricity generation capacity in the nuclear plant, reducing capacity payments and the maximum output to the electrical grid. This analysis considers building a separate hydrogen pipeline for use in the nuclear facility. Research is currently being conducted to determine if existing natural gas pipelines can accommodate direct hydrogen injection. If hydrogen can be integrated into existing natural gas pipelines then a capital savings of ~$19,000,000 per kg/sec [1 kg/sec = 86.4 tpd] of installed HTSE capacity could be realized. Fast transients in the electric grid are typically served by flywheels and electric batteries. With electrolysis only operation the nuclear plant can flex its electricity just as quickly. However, for this analysis, the ancillary services market has been neglected. Should the nuclear plant have the ability to operate in the ancillary services market during periods when it is producing hydrogen, an additional substantial income stream that would increase overall system profitability could be considered. Subsidies for non-emitting generation technologies are not introduced in the cash flow analysis, but instead are completed assuming zero subsidies. Profitability is based solely on electricity pricing. Electric pricing is assumed to never go negative. Instead, it is assumed overall system curtailment by the Independent System Operator (ISO) will occur in such a manner that pricing remains at or above zero. This assumption inflates the “business as usual” scenario, thus decreasing the ΔNPV calculated. If negative pricing scenarios continue to occur as they do today, one would expect a further increase in ΔNPV. Overall, results advocate that, through market diversification, nuclear power plants have the potential to substantially increase current profit margins, increase market penetration, and ultimately solidify their place as a mainstay in energy production.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synergies and trade-offs between storage, transmission, and sector coupling in high renewable energy systems

Energy storage, transmission, and sector coupling are some prominent flexibility solutions to support variable renewable energy (VRE) integration. However, investment cost uncertainties and public acceptance could hamper the deployment of these flexibility solutions. This raises questions about the development and cost-effectiveness of future energy systems, especially on how the dependence on local and cross-border solutions of flexibility would evolve if the uptake of these solutions is restricted. In this context, this paper identifies the synergies among flexibility options under restrictions on transmission expansion or increased costs of energy storage. It contributes to determining whether investments in energy storage and/or transmission expansion offer the least-cost transition and investigates the impact of sector coupling on these solutions. A long-term energy system planning and optimisation model towards 2050 is developed using the open-source energy system optimisation tool Balmorel, and a case study of the countries surrounding the Baltic Sea and the North Sea is established. Five cases with restrictions imposed on transmission expansion and higher energy storage technology costs are analysed at different levels of sector coupling. The results highlight the importance of transmission expansion at all levels of sector coupling. As the level of sector coupling increases, uncertainties around the cost of energy storage drive the least-cost pathways. Optimal investment solutions are found to have a mix of transmission and energy storage in capacity expansion at all levels of sector coupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗