Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Piecewise interaction picture density matrix quantum Monte Carlo

The density matrix quantum Monte Carlo (DMQMC) set of methods stochastically samples the exact N-body density matrix for interacting electrons at finite temperature. We introduce a simple modification to the interaction picture DMQMC (IP-DMQMC) method that overcomes the limitation of only sampling one inverse temperature point at a time, instead allowing for the sampling of a temperature range within a single calculation, thereby reducing the computational cost. At the target inverse temperature, instead of ending the simulation, we incorporate a change of picture away from the interaction picture. The resulting equations of motion have piecewise functions and use the interaction picture in the first phase of a simulation, followed by the application of the Bloch equation once the target inverse temperature is reached. We find that the performance of this method is similar to or better than the DMQMC and IP-DMQMC algorithms in a variety of molecular test systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sputter sample preparation for ion beam delivery of radium-223 at ATLAS

A radium-223 ion beam was delivered to an experiment from the electron cyclotron resonance ion source, ECR2, at the Argonne Tandem Linac Accelerator System (ATLAS). Here, the radium-223 material was in a nitrate salt form within a vial, prior to being converted to a usable sputter sample. The sputter sample was produced using a new sample preparation method, where the radium nitrate was dissolved into a solution and pipetted onto pressed aluminum powder. This sample was then allowed to dry, distributing the radium-223 material throughout the sputter sample. Ion source operation using the radium sputter sample is described with the operating parameters listed. The intensity and energy requirements for this ion beam were 1 × 10 6 particles/s and 1.07 GeV, respectively. Because the intensity is relatively low compared to most experiments at ATLAS, previously developed accelerator mass spectrometry methods were used Scott et al. to avoid the need for tuning of the low-intensity beam of interest. Handling of the radium material, as well as loading and unloading of the sputter sample from ECR2, required collaboration with Health Physics. Procedures were used and dry runs were carried out before, during, and after the experiment to ensure the safety of the workers. The processes used and lessons learned are described within.

07 ISOTOPE AND RADIATION SOURCES↗

Method for isolating nucleic acids

The current disclosure provides methods and kits for isolating nucleic acid from an environmental sample. The current methods and compositions further provide methods for isolating nucleic acids by reducing adsorption of nucleic acids by charged ions and particles within an environmental sample. The methods of the current disclosure provide methods for isolating nucleic acids by releasing adsorbed nucleic acids from charged particles during the nucleic acid isolation process. The current disclosure facilitates the isolation of nucleic acids of sufficient quality and quantity to enable one of ordinary skill in the art to utilize or analyze the isolated nucleic acids for a wide variety of applications including, sequencing or species population analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Use of Longitudinal Serum Analysis and Machine Learning to Develop a Classifier for Cancer Early Detection

Early detection of solid tumors through a simple screening process, such as the proteomic analysis of biofluids, has the potential to significantly alter the management and outcomes of cancers. The application of advanced targeted proteomics measurements and data analysis strategies to uniformly collected serum or plasma samples would enable longitudinal studies of cancer risk, progression, and response to therapy that have the potential to significantly reduce cancer burden in general. In this article, we describe a generalizable workflow combining robust, multiplexed targeted proteomics measurements applied to longitudinal samples from the Department of Defense Serum Repository with a Random Forest machine learning method for developing and initially evaluating the performance of candidate biomarker panels for early detection of cancers. The effectiveness of this approach was demonstrated in a cohort of 175 head and neck squamous cell carcinoma patients. The outlined protocols include methods for sample preparation, instrument analysis, and data analysis and interpretation using this workflow.

Longitudinal analysis, machine learning, cancer, e↗

Regulation of steroid hormones and energy status with cysteamine and its effect on spermatogenesis

Although it is well known that cysteamine is a potent chemical for treating many diseases including cystinosis and it has many adverse effects, the effect of cysteamine on spermatogenesis is as yet unknown. Therefore the objective of this investigation was to explore the effects of cysteamine on spermatogenesis and the underlying mechanisms. Sheep were treated with vehicle control, 10 mg/kg or 20 mg/kg cysteamine for six months. After that, the semen samples were collected to determine the spermatozoa motility by computer-assisted sperm assay method. Blood samples were collected to detect the levels of hormones and the activity of enzymes. Spermatozoa and testis samples were collected to study the mechanism of cysteamine's actions. It was found that the effects of cysteamine on spermatogenesis were dose dependent. A low dose (10 mg/kg) cysteamine treatment increased ovine spermatozoa motility; however, a higher dose (20 mg/kg) decreased both spermatozoa concentration and motility. This decrease might be due to a reduction in steroid hormone production by the testis, a reduction in energy in the testis and spermatozoa, a disruption in the blood-testis barrier, or a breakdown in the vital signaling pathways involved in spermatogenesis. The inhibitory effects of cysteamine on sheep spermatogenesis may be used to model its effects on young male patients with cystinosis or other diseases that are treated with this drug. Further studies on spermatogenesis that focus on patients treated with cysteamine during the peripubertal stage are warranted. - Highlights: • Dose dependent effects of cysteamine on spermatogenesis • A low dose (10 mg/kg) increased spermatozoa motility. • A higher dose (20 mg/kg) decreased both concentration and motility of spermatozoa. • Disruption in the blood-testis barrier caused reduction in concentration and motility.

60 APPLIED LIFE SCIENCES↗

Frictional conditions between alloy AA6060 aluminium and tool steel

The frictional conditions in the new process of screw extrusion of aluminium have been investigated. The contact behaviour between the aluminum alloy and the tool steel in the extruder is vital for understanding the extrusion process. Using a compressive-rotational method for frictional measurements the conditions for unlubricated sticking friction between aluminum alloy AA6060 and tool steel at different combinations of temperatures and pressures have been investigated. In this method the samples in the form of disks are put under hydrostatic pressure while simultaneously being rotated at one end. Pins made from contrast material have been inserted into the samples to measure the deformation introduced. This approach along with 3D simulations form a method for determining the frictional conditions. The paper describes the test method and the results. It was found that the necessary pressure for sticking to occur between the aluminum AA6060 and the different parts of the extruder is heavily influenced by the temperature.

36 MATERIALS SCIENCE↗

Probability techniques for reliability analysis of composite materials

Traditional design approaches for composite materials have employed deterministic criteria for failure analysis. New approaches are required to predict the reliability of composite structures since strengths and stresses may be random variables. This report will examine and compare methods used to evaluate the reliability of composite laminae. The two types of methods that will be evaluated are fast probability integration (FPI) methods and Monte Carlo methods. In these methods, reliability is formulated as the probability that an explicit function of random variables is less than a given constant. Using failure criteria developed for composite materials, a function of design variables can be generated which defines a 'failure surface' in probability space. A number of methods are available to evaluate the integration over the probability space bounded by this surface; this integration delivers the required reliability. The methods which will be evaluated are: the first order, second moment FPI methods; second order, second moment FPI methods; the simple Monte Carlo; and an advanced Monte Carlo technique which utilizes importance sampling. The methods are compared for accuracy, efficiency, and for the conservativism of the reliability estimation. The methodology involved in determining the sensitivity of the reliability estimate to the design variables (strength distributions) and importance factors is also presented.

Wetherhold, Robert C.↗

Loss of solar He and Ne from IDPS in subducting sediment: Diffusion and the effect of phase changes

The results of the diffusion experiment for solar He and Ne in IDP's in a magnetic separate from Pacific Ocean sediment suggest that solar He and Ne would be easily released from IDP grains and hence lost from subducting slabs at shallow depths. However, since the diffusion experiments was conducted under high vacuum, there may be a possibility that magnetite grains, which are supposedly the main constituent of the magnetic fraction, might be partly reduced to form a metal phase due to low oxygen fugacity in the experimental condition. If this is the case, such a phase change might affect the gas release and hence the results of the diffusion coefficients. In order to examine whether or not such a phase change really occurred in the condition of the diffusion experiment, I conducted a heating experiment for a magnetic separate from Pacific Ocean sediment. In the same condition as in the diffusion experiment, and the run products were examined with an x ray diffraction method. Three samples were prepared: they were wrapped with platinum foil, put in a vacuum line, and heated in a molybdenum crucible for two hours at 500 C, 800 C,and 950 C, respectively. After cooling the furnace, the samples were taken out from the crucible and analyzed with an x ray diffraction method.

Hiyagon, H.↗

System and method for measuring particles in a sample stream of a flow cytometer or the like

A system and method for analyzing a particle in a sample stream of a flow cytometer or the like. The system has a light source, such as a laser pointer module, for generating a low powered light beam and a fluidics apparatus which is configured to transport particles in the sample stream at substantially low velocity through the light beam for interrogation. Detectors, such as photomultiplier tubes, are configured to detect optical signals generated in response to the light beam impinging the particles. Signal conditioning circuitry is connected to each of the detectors to condition each detector output into electronic signals for processing and is designed to have a limited frequency response to filter high frequency noise from the detector output signals.

Graves, Steven W↗

Parallel optical sampler

An optical sampler includes a first and second 1.times.n optical beam splitters splitting an input optical sampling signal and an optical analog input signal into n parallel channels, respectively, a plurality of optical delay elements providing n parallel delayed input optical sampling signals, n photodiodes converting the n parallel optical analog input signals into n respective electrical output signals, and n optical modulators modulating the input optical sampling signal or the optical analog input signal by the respective electrical output signals, and providing n successive optical samples of the optical analog input signal. A plurality of output photodiodes and eADCs convert the n successive optical samples to n successive digital samples. The optical modulator may be a photodiode interconnected Mach-Zehnder Modulator. A method of sampling the optical analog input signal is disclosed.

47 OTHER INSTRUMENTATION↗

Ambient Metabolic Profiling and Imaging of Biological Samples with Ultrahigh Molecular Resolution using Laser Ablation Electrospray Ionization 21 Tesla FTICR Mass Spectrometry

Mass spectrometry (MS) has been an indispensable analytical tool in capturing the complexity and array of biomolecules within biological systems. However, conventional MS-based analytical workflows are limited in both throughput and measuring the native molecular state these systems, due in large part to sample handling and preparation. The development of ambient ionization methods capable of sampling directly from tissues circumvent many of these issues but requires the use of high-performance MS to resolve the molecular complexity within these samples. Herein, we demonstrate the unique combination of laser ablation electrospray ionization (LAESI) coupled with a 21 Tesla Fourier transform ion cyclotron resonance (21T-FTICR-MS) for MS imaging applications. This analytical platform provides isotopic fine structure information directly from native tissues, delivering a higher degree of confidence for molecular identification. The ability to capture and visualize the complex metabolic behavior of living organisms in situ is a bioanalytical grand challenge that has yet to be fully realized. Due to their excellent sensitivity and selectivity, mass spectrometry (MS)-based platforms offer a unique opportunity to characterize an array of biomolecules from a variety of biological samples.[1] One method in particular, MS imaging (MSI), has demonstrated the ability to simultaneously determine the spatial distributions for hundreds of biomolecules, e. g., metabolites, lipids, peptides, and xenobiotics, within complex biological systems simultaneously.[2-3] Matrix-assisted laser desorption/ionization (MALDI)-MSI remains the most common of these methods.[4] However, the application of an exogenous matrix, and the limited availability of commercial sources that operate under atmospheric pressure,[5] has significantly prohibited the ability of MALDI to be useful for biomolecular mapping of living systems. Ambient ionization methods that require minimal to no sample preparation, like desorption electrospray ionization (DESI and nano-DESI) and laser ablation electrospray ionization (LAESI), demonstrated the ability to spatially map biomolecule distributions within live organisms.

Mass Spectometry, fourier transform ion cyclostron↗

Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Outsourced probe data effectiveness on signalized arterials

This paper presents results of an I-95 Corridor Coalition sponsored project to assess the ability of outsourced vehicle probe data to provide accurate travel time on signalized roadways for the purposes of real-time operations as well as performance measures. The quality of outsourced probe data on freeways has led many departments of transportation to consider such data for arterial performance monitoring. From April 2013 through June of 2014, the University of Maryland Center for Advanced Transportation Technology gathered travel times from several arterial corridors within the mid-Atlantic region using Bluetooth traffic monitoring (BTM) equipment, and compared these travel times with the data reported to the I95 Vehicle Probe Project (VPP) from an outsourced probe data vendor. The analysis consisted of several methodologies: (1) a traditional analysis that used precision and bias speed metrics; (2) a slowdown analysis that quantified the percentage of significant traffic disruptions accurately captured in the VPP data; (3) a sampled distribution method that uses overlay methods to enhance and analyze recurring congestion patterns. (4) Last, the BTM and VPP data from each 24-hour period of data collection were reviewed by the research team to assess the extent to which VPP captured the nature of the traffic flow. Based on the analysis, probe data is recommended only on arterial roadways with signal densities (measured in signals per mile) up to one, and it should be tested and used with caution for signal densities between one and two, and is not recommended when signal density exceeds two.

33 ADVANCED PROPULSION SYSTEMS↗

Measurement of interfacial shear strength in SiC-fiber/Si3N4 composites

An indentation method for measuring shear strength in brittle matrix composites was applied to SiC-fiber/Si3N4-matrix samples. Three methods were used to manufacture the composites: reaction bonding of a Si/SiC preform, hot-pressing, and nitrogen-overpressure sintering. An indentation technique developed by Marshall for thin specimens was used to measure the shear strength of the interface and the interfacial friction stresses. This was done by inverting the sample after the initial push through and retesting the pushed fibers. SEM observations showed that the shear strength was determined by the degree of reaction between the fiber and the matrix unless the fiber was pushed out of its (well-bonded) sheath.

Laughner, James W.↗

Monte Carlo simulation applied in total reflection x-ray fluorescence: Preliminary results

The X-ray Fluorescence (XRF) analysis is a technique for the qualitative and quantitative determination of chemical constituents in a sample. This method is based on detection of the characteristic radiation intensities emitted by the elements of the sample, when properly excited. A variant of this technique is the Total Reflection X-ray Fluorescence (TXRF) that utilizes electromagnetic radiation as excitation source. In total reflection of X-ray, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample support interface. Thus, there is a minimum angle of incidence at which no refracted beam exists and all incident radiation undergoes total reflection. In this study, we evaluated the influence of the energy variation of the beam of incident x-rays, using the MCNPX code (Monte Carlo NParticle) based on Monte Carlo method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-isothermal crystallization kinetics of Fe{sub 2}O{sub 3}–CaO–SiO{sub 2} glass containing nucleation agent P{sub 2}O{sub 5}/TiO{sub 2}

Fe{sub 2}O{sub 3}–CaO–SiO{sub 2} glass ceramics containing nucleation agent P{sub 2}O{sub 5}/TiO{sub 2} were prepared by sol-gel method. The samples were characterized by X-ray diffraction (XRD) and differential scanning calorimetry (DSC). The activation energy and kinetic parameters for crystallization of the samples were calculated by the Johnson-Mehi-Avrami (JMA) model and Augis-Bennett method according to the results of DSC. The results showed that the crystallization mechanism of Fe{sub 2}O{sub 3}–CaO–SiO{sub 2} glass, whose non-isothermal kinetic parameter n = 2.3, was consistent with surface crystallization of the JMA model. The kinetics model function of Fe{sub 2}O{sub 3}–CaO–SiO{sub 2} glass, f(α) = 2.3(1–α)[–ln(1–α)]{sup 0.57}, was also obtained. The addition of nucleation agent P{sub 2}O{sub 5}/TiO{sub 2} could reduce the activation energy, which made the crystal growth modes change from onedimensional to three-dimensional.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of buried undercut structures in microfluidic devices by laser fluorescent confocal microscopy

Measuring buried, undercut microstructures is a challenging task in metrology. These structures are usually characterized by measuring their cross sections after physically cutting the samples. This method is destructive and the obtained information is incomplete. The distortion due to cutting also affects the measurement accuracy. In this paper, we first apply the laser fluorescent confocal microscopy and intensity differentiation algorithm to obtain the complete three-dimensional profile of the buried, undercut structures in microfluidic devices, which are made by the soft lithography technique and bonded by the oxygen plasma method. The impact of material wettability and the refractive index (n) mismatch among the liquid, samples, cover layer, and objective on the measurement accuracy are experimentally investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculation of Weibull strength parameters, Batdorf flaw density constants and related statistical quantities using PC-CARES

This manual describes the operation and theory of the PC-CARES (Personal Computer-Ceramic Analysis and Reliability Evaluation of Structures) computer program for the IBM PC and compatibles running PC-DOS/MS-DOR OR IBM/MS-OS/2 (version 1.1 or higher) operating systems. The primary purpose of this code is to estimate Weibull material strength parameters, the Batdorf crack density coefficient, and other related statistical quantities. Included in the manual is the description of the calculation of shape and scale parameters of the two-parameter Weibull distribution using the least-squares analysis and maximum likelihood methods for volume- and surface-flaw-induced fracture in ceramics with complete and censored samples. The methods for detecting outliers and for calculating the Kolmogorov-Smirnov and the Anderson-Darling goodness-of-fit statistics and 90 percent confidence bands about the Weibull line, as well as the techniques for calculating the Batdorf flaw-density constants are also described.

Szatmary, Steven A.↗