At least 1,045 records · Page 58

Adapting Human Reliability Analysis from Nuclear Power to Oil and Gas Applications

ABSTRACT: Human reliability analysis (HRA), as currently used in risk assessments, largely derives its methods and guidance from application in the nuclear energy domain. While there are many similarities be-tween nuclear energy and other safety critical domains such as oil and gas, there remain clear differences. This paper provides an overview of HRA state of the practice in nuclear energy and then describes areas where refinements to the methods may be necessary to capture the operational context of oil and gas. Many key distinctions important to nuclear energy HRA such as Level 1 vs. Level 2 analysis may prove insignifi-cant for oil and gas applications. On the other hand, existing HRA methods may not be sensitive enough to factors like the extensive use of digital controls in oil and gas. This paper provides an overview of these con-siderations to assist in the adaptation of existing nuclear-centered HRA methods to the petroleum sector.

human reliability analysis↗

An uncertainty quantification method relevant to material test reactors

Within material test reactor calculations, energy dependent flux and reaction rate uncertainties are typically not quantified when performing as-run analyses to determine the neutron field experienced by the experiment. When high fidelity Monte-Carlo codes are used in such analyses, straight forward methods to calculate output uncertainties are not available, instead expert opinion is used to postulate computational uncertainties. New methods to propagate uncertainties through these high fidelity simulations are available when sufficient computational power is available. A tool is developed here for sampling any part of an MCNP input from random distributions to determine output uncertainties based on those inputs. Another tool is developed to sample nuclear data cross-section in ACE format using multi-group nuclear data covariances. The Total Monte-Carlo Method and Gesellschaft für Anlagen-und Reaktorsicherheit method (GRS) are implemented and compared to one another as well as MCNP sensitivity and uncertainty calculations. The methods were applied to the Godiva critical sphere k-eigenvalue, the UAM pin-cell benchmark energy dependent flux and reaction rates, and the Advanced Test Reactor energy dependent flux within an experimental location. Furthermore, the two methods agree well, with GRS allowing for an order of magnitude speedup for reaction rate uncertainty calculations and several orders of magnitude for eigenvalue uncertainty calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calibration of measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy using a contact detection method

An accurate experimental method is proposed for on-spot calibration of the measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy. One of the key techniques devised for this method is a reliable contact detection mechanism that detects the tip-surface contact instantly. At the contact instant, the oscillation amplitude of the tip deflection, converted to that of the deflection signal in laser reading through the measurement sensitivity, exactly equals to the distance between the sample surface and the cantilever base position. Therefore, the proposed method utilizes the recorded oscillation amplitude of the deflection signal and the base position of the cantilever at the contact instant for the measurement sensitivity calibration. Experimental apparatus along with various signal processing and control modules was realized to enable automatic and rapid acquisition of multiple sets of data, with which the calibration of a single dynamic mode could be completed in less than 1 s to suppress the effect of thermal drift and measurement noise. Calibration of the measurement sensitivities of the first and second dynamic modes of three micro-cantilevers having distinct geometries was successfully demonstrated. The dependence of the measurement sensitivity on laser spot location was also experimentally investigated. Finally, an experiment was performed to validate the calibrated measurement sensitivity of the second dynamic mode of a micro-cantilever.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of electron temperature from signal ratios in a double-pass Thomson scattering system

This paper presents an experimental demonstration to determine electron temperature (T{sub e}) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scattering angles) are measured separately. T{sub e} can be determined from the ratio of the signal intensities without knowing a real chromatic dependence in the sensitivity. Note that the wavelength range for each spectral channel must be known. This method was applied to the TST-2 Thomson scattering system. As a result, T{sub e} measured from the ratio (T{sub e,r}) and T{sub e} measured from a standard method (T{sub e,s}) showed a good agreement with <|T{sub e,r}-T{sub e,s}|/T{sub e,s}>= 7.3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameterization and sensitivity analysis of a process‐based terrestrial ecosystem model using adjoint method

Abstract We developed an adjoint version of a process‐based biogeochemistry model, the Terrestrial Ecosystem Model (TEM). The adjoint model of TEM was then used to: (1) conduct sensitivity studies of net ecosystem production (NEP) for three terrestrial ecosystems: grassland, deciduous broadleaf forest and evergreen needle‐leaf forest; (2) rank the importance of parameters in controlling NEP; (3) optimize the model parameters by assimilating eddy flux data of NEP; and (4) evaluate parameterization by extrapolating optimal parameters to other sites that have the same plant functional type as the calibration sites. We found that: (1) the maximum rate of photosynthesis ( C MAX ) was the most important parameter in determining NEP, while the importance of the remaining parameters varied depending on plant functional type, suggesting that the same ecosystem process has different degrees of importance in modeling carbon fluxes; (2) the sensitivity of NEP to C MAX had a significant seasonal variability and the control of C MAX on NEP was much larger in growing season (defined as from April to October) than that in nongrowing season (defined as from December to March); and (3) after parameterization, TEM could reasonably reproduce carbon fluxes observed at eddy flux tower sites. This study provided an effective model‐data fusion framework of TEM, which could improve the future quantification of terrestrial ecosystem carbon fluxes at both site and regional levels.

Zhu, Qing↗

SU-F-T-308: Mobius FX Evaluation and Comparison Against a Commercial 4D Detector Array for VMAT Plan QA

Purpose: To evaluate the use of MobiusFX as a pre-treatment verification IMRT QA tool and compare it with a commercial 4D detector array for VMAT plan QA. Methods: 15 VMAT plan QA of different treatment sites were delivered and measured by traditional means with the 4D detector array ArcCheck (Sun Nuclear corporation) and at the same time measurement in linac treatment logs (Varian Dynalogs files) were analyzed from the same delivery with MobiusFX software (Mobius Medical Systems). VMAT plan QAs created in Eclipse treatment planning system (Varian) in a TrueBeam linac machine (Varian) were delivered and analyzed with the gamma analysis routine from SNPA software (Sun Nuclear corporation). Results: Comparable results in terms of the gamma analysis with 99.06% average gamma passing with 3%,3mm passing rate is observed in the comparison among MobiusFX, ArcCheck measurements, and the Treatment Planning System dose calculated. When going to a stricter criterion (1%,1mm) larger discrepancies are observed in different regions of the measurements with an average gamma of 66.24% between MobiusFX and ArcCheck. Conclusion: This work indicates the potential for using MobiusFX as a routine pre-treatment patient specific IMRT method for quality assurance purposes and its advantages as a phantom-less method which reduce the time for IMRT QA measurement. MobiusFX is capable of produce similar results of those by traditional methods used for patient specific pre-treatment verification VMAT QA. Even the gamma results comparing to the TPS are similar the analysis of both methods show that the errors being identified by each method are found in different regions. Traditional methods like ArcCheck are sensitive to setup errors and dose difference errors coming from the linac output. On the other hand linac log files analysis record different errors in the VMAT QA associated with the MLCs and gantry motion that by traditional methods cannot be detected.

60 APPLIED LIFE SCIENCES↗

Involute Working Group – FSI Analysis of Fuel Plates Using Finite Volume and Finite Element Methods

The three involute plate research reactors RHF, HFIR, and FRM II have expressed an interest in using computational software to carry their steady-state safety analysis. Since these tools represent a significant departure from the methods used currently (one-dimensional), the acceptability of the new approach by regulators requires thorough verification and validation of these tools. Therefore, Argonne National Laboratory and the three involute-plate reactors formed an informal group called the Involute Working Group aiming at qualifying computational tools to perform steady-state safety analysis. The present report focuses on a comparison of finite volume and finite element methods to model solids in fluid-structure interaction problems with the goal to estimate the coolant flow-induced fuel plate deflections obtained with the two methods. The finite volume method will be obsoleted in STARCCM+ by the end of 2021, nevertheless, this evaluation is important because the method was used by ANL researchers to model the response of the fuel plates, despite its drawbacks, which are discussed in the report. It was essential to check how those estimates compare to the results obtained with the finite element method that is considered superior for structural analysis. Various geometries, i.e., flat, cylindrical and circle-involute fuel plates, as well as coolant flow speed, were considered. The comparison shows that, independently of the plate geometry, the finite volume method significantly underestimates the deflection as compared to finite element method for coarser meshes. When the discretization is developed as a result of a mesh sensitivity study using finite element method, the result obtained using finite volume method can be a few times smaller than the corresponding finite element method solution. A code-to-code comparison , between STAR-CCM+ and LS-DYNA was included in the analysis. Within the LS-DYNA models, two types of finite element formulations were used: solid and shell finite elements. Mesh sensitivity study showed that both approaches converge to a similar value that was obtained with STAR-CCM+ finite element solver. The evaluation of the computational solvers was extended by adding two benchmark cases from the STAR-CCM+ Verification Suite and presented in the Appendix A. The selected cases are: (1) bending of a cantilever beam under external load, and (2) cylindrical shell deformation analysis, known in the literature as ‘Scordelis-Lo roof’. The problems were solved with finite volume, and finite element methods, and the results confirmed the previously discussed findings. The analysis shows that the finite element solver is superior to the finite volume solver in terms of representation of model geometry and estimating the structural behavior of fuel plates. Depending on the ratio of the load to the flexibility of the plate, the finite volume solver can greatly under- or overestimate the structural response if a very carefully selected mesh is not used.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Achievement of 6.03% conversion efficiency of dye-sensitized solar cells with single-crystalline rutile TiO{sub 2} nanorod photoanode

The rutile TiO{sub 2} nanorods (RTNs) with the length of 40-130 nm and diameters approximately 8-15 nm, containing some 300-500 nm sized RTN aggregates and 6% of anatase TiO{sub 2} nanocrystals, were prepared by surfactant-assisted hydrothermal method. The dye-sensitized solar cell (DSC) based on the RTNs exhibited power conversion efficiency of 6.03%. As compared to P25 TiO{sub 2} based DSC, RTNs based DSC shows improved light-harvesting and Brunauer-Emmett-Teller surface area, leading to an increase in short-circuit current (J{sub sc}) by 40.6%.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Deformation of {lambda} hypernuclei

We study the deformation property of {lambda} hypernuclei using the relativistic mean-field (RMF) method. We find that {sub {lambda}}{sup 29}Si and {sub {lambda}}{sup 13}C hypernuclei have a spherical shape as a consequence of the additional {lambda} particle, whereas the corresponding core nuclei, {sup 28}Si and {sup 12}C, are oblately deformed. Most other hypernuclei have a similar deformation parameter to the core nucleus, in accordance with the previous study with the nonrelativistic Skyrme-Hartree-Fock method. We discuss the sensitivity of our results to the choice of pairing interaction and to the parameter set of the RMF Lagrangian.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity analysis for dose deposition in radiotherapy via a Fokker–Planck model

In this paper, we study the sensitivities of electron dose calculations with respect to stopping power and transport coefficients. We focus on the application to radiotherapy simulations. We use a Fokker–Planck approximation to the Boltzmann transport equation. Equations for the sensitivities are derived by the adjoint method. The Fokker–Planck equation and its adjoint are solved numerically in slab geometry using the spherical harmonics expansion (P N ) and an Harten-Lax-van Leer finite volume method. Our method is verified by comparison to finite difference approximations of the sensitivities. Finally, we present numerical results of the sensitivities for the normalized average dose deposition depth with respect to the stopping power and the transport coefficients, demonstrating the increase in relative sensitivities as beam energy decreases. In conclusion, this in turn gives estimates on the uncertainty in the normalized average deposition depth, which we present.

59 BASIC BIOLOGICAL SCIENCES↗

Microscale thermophoresis as a powerful tool for screening glycosyltransferases involved in cell wall biosynthesis

Background: Identification and characterization of key enzymes associated with cell wall biosynthesis and modification is fundamental to gain insights into cell wall dynamics. However, it is a challenge that activity assays of glycosyltransferases are very low throughput and acceptor substrates are generally not available. Results: We optimized and validated microscale thermophoresis (MST) to achieve high throughput screening for glycosyltransferase substrates. MST is a powerful method for the quantitative analysis of protein-ligand interactions with low sample consumption. The technique is based on the motion of molecules along local temperature gradients, measured by fluorescence changes. We expressed glycosyltransferases as YFP-fusion proteins in tobacco and optimized the MST method to allow the determination of substrate binding affinity without purification of the target protein from the cell lysate. The application of this MST method to the β-1,4-galactosyltransferase AtGALS1 validated the capability to screen both nucleotide-sugar donor substrates and acceptor substrates. We also expanded the application to members of glycosyltransferase family GT61 in sorghum for substrate screening and function prediction. Conclusions: This method is rapid and sensitive to allow determination of both donor and acceptor substrates of glycosyltransferases. MST enables high throughput screening of glycosyltransferases for likely substrates, which will narrow down their in vivo function and help to select candidates for further studies. Additionally, this method gives insight into biochemical mechanism of glycosyltransferase function.

59 BASIC BIOLOGICAL SCIENCES↗

Determining neutrino absorption spectra at ultra-high energies

A very efficient method for measuring the flux of ultra-high energy (UHE) neutrinos is through the detection of radio waves which are emitted by the particle shower in the lunar regolith. The highest acceptance is reached for radio waves in the frequency band of 100-200 MHz which can be measured with modern radio telescopes. In this work we investigate the sensitivity of this detection method to structures in the UHE neutrino spectrum caused by their absorption on the low energy relic anti-neutrino background through the Z boson resonance. The position of the absorption peak is sensitive to the neutrino mass and the redshift of the source. A new generation of low frequency digital radio telescopes will provide excellent detection capabilities for measuring these radio pulses, thus making our consideration here very timely.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities

Increased penetration levels of distributed variable renewable generation can cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But because of the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network are needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69-node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time-series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination and control – limits in standard representations of multi-reservoir operations in hydrological modeling

Abstract. Major multi-reservoir cascades represent a primary mechanism for dealing with hydrologic variability and extremes within institutionally complex river basins worldwide. These coordinated management processes fundamentally reshape water balance dynamics. Yet, multi-reservoir coordination processes have been largely ignored in the increasingly sophisticated representations of reservoir operations within large-scale hydrological models. The aim of this paper is twofold, namely (i) to provide evidence that the common modeling practice of parameterizing each reservoir in a cascade independently from the others is a significant approximation and (ii) to demonstrate potential unintended consequences of this independence approximation when simulating the dynamics of hydrological extremes in complex reservoir cascades. We explore these questions using the Water Balance Model, which features detailed representations of the human infrastructure coupled to the natural processes that shape water balance dynamics. It is applied to the Upper Snake River basin in the western US and its heavily regulated multi-reservoir cascade. We employ a time-varying sensitivity analysis that utilizes the method of Morris factor screening to explicitly track how the dominant release rule parameters evolve both along the cascade and in time according to seasonal high- and low-flow events. This enables us to address aim (i) by demonstrating how the progressive and cumulative dominance of upstream releases significantly dampens the ability of downstream reservoir rules' parameters to influence flow conditions. We address aim (ii) by comparing simulation results with observed reservoir operations during critical low-flow and high-flow events in the basin. Our time-varying parameter sensitivity analysis with the method of Morris clarifies how independent single-reservoir parameterizations and their tacit assumption of independence leads to reservoir release behaviors that generate artificial water shortages and flooding, whereas the observed coordinated cascade operations avoided these outcomes for the same events. To further explore the role of (non-)coordination in the large deviations from the observed operations, we use an offline multi-reservoir water balance model in which adding basic coordination mechanisms drawn from the observed emergency operations is sufficient to correct the deficiencies of the independently parameterized reservoir rules from the hydrological model. These results demonstrate the importance of understanding the state–space context in which reservoir releases occur and where operational coordination plays a crucial role in avoiding or mitigating water-related extremes. Understanding how major infrastructure is coordinated and controlled in major river basins is essential for properly assessing future flood and drought hazards in a changing world.

54 ENVIRONMENTAL SCIENCES↗

Assessing alcohol intake & its dose-dependent effects on liver enzymes by 24-h recall and questionnaire using NHANES 2001-2010 data

Alcohol is a significant component of the diet with dose-dependent risks and benefits. High doses of alcohol damage the liver and early symptoms of liver disease include changes in routinely assessed liver enzymes. Less is known regarding the mechanisms responsible for the benefits of moderate alcohol consumption, including their effects on the liver. The objectives of this study were to examine alcohol’s dose-dependent effects on markers of liver function (alkaline phosphatase (ALP), alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma glutamyl transferase (GGT), and bilirubin), as well as to compare the different methods of assessing alcohol intake using NHANES 2001–2010 adult data (N =24,807). Three methods were used to estimate alcohol intake from all volunteers: 24-h recall; the National Cancer Institute (NCI) method of usual intake; and a specific alcohol intake questionnaire. Mean alcohol intake by 24-h recall, NCI method and questionnaire was 41.0 ± 0.8 g/d, 10.9 ± 0.2 g/d and 11.0 ± 0.2 g/d, respectively. Alcohol consumers had significantly lower levels of ALP and higher levels of AST, GGT and bilirubin compared to non-consumers (P < 0.01) and activities of ALT, AST, and GGT increased and of ALP decreased as alcohol intake increased, regardless of intake assessment method used. The most sensitive measure of alcohol consumption was GGT. Since alcohol had a graded linear effect on several liver enzymes, including at low and moderate doses, benefits as well as risks of alcohol intake may be related to liver function. In conclusion, since the NCI method and alcohol questionnaire yielded very similar alcohol intake estimates, this study cross-validated these methods and demonstrated the robustness of the NCI method for estimating intake of irregularly consumed foods.

60 APPLIED LIFE SCIENCES↗

Improvement on the catalytic activity of the flexible PEDOT counter electrode in dye-sensitized solar cells

Highlights: • The catalytic activity of PEDOT electrode can be tuned by varying deposited time. • A highly effective Pt/PEDOT electrode was also prepared. • The DSSCs using Pt/PEDOT counter electrode shows high efficiency of 7.90%. - Abstract: A flexible Poly (3, 4-ethylenedioxythiophene) (PEDOT) electrode on indium-doped tin oxide coated polyethylene naphthalate (ITO-PEN) substrate is prepared by electrochemical methods for dye-sensitized solar cells (DSSCs) as counter electrode. The impact of deposition time on the catalytic activities of the flexible PEDOT electrode towards the iodide redox couple has been investigated by cyclic voltammetry, electrochemical impedance spectroscopy (EIS) and Tafel polarization curve measurements. After optimization, the DSSCs using PEDOT counter electrode deposited 80 s shows power conversion efficiency (PCE) of 7.18%, close to than the Pt counter electrode based counterpart (7.56%). To further improve the catalytic activity of PEDOT, Pt/PDEOT composite catalyst is synthesized. And the DSSCs with the Pt/PDEOT composite CE generates a high PCE of 7.90%.