Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

THE BORN-AGAIN PLANETARY NEBULA A78: AN X-RAY TWIN OF A30

We present the XMM-Newton discovery of X-ray emission from the planetary nebula (PN) A78, the second born-again PN detected in X-rays apart from A30. These two PNe share similar spectral and morphological characteristics: they harbor diffuse soft X-ray emission associated with the interaction between the H-poor ejecta and the current fast stellar wind and a point-like source at the position of the central star (CSPN). We present the spectral analysis of the CSPN, using for the first time an NLTE code for expanding atmospheres that takes line blanketing into account for the UV and optical spectra. The wind abundances are used for the X-ray spectral analysis of the CSPN and the diffuse emission. The X-ray emission from the CSPN in A78 can be modeled by a single C VI emission line, while the X-ray emission from its diffuse component is better described by an optically thin plasma emission model with a temperature of kT = 0.088 keV (T ≈ 1.0 × 10{sup 6} K). We estimate X-ray luminosities in the 0.2-2.0 keV energy band of L {sub X,} {sub CSPN} = (1.2 ± 0.3) × 10{sup 31} erg s{sup –1} and L {sub X,} {sub DIFF} = (9.2 ± 2.3) × 10{sup 30} erg s{sup –1} for the CSPN and diffuse components, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultralow-threshold, continuous-wave upconverting lasing from subwavelength plasmons

Miniaturized lasers are an emerging platform for generating coherent light for quantum photonics, in vivo cellular imaging, solid-state lighting and fast three-dimensional sensing in smartphones. Continuous-wave lasing at room temperature is critical for integration with opto-electronic devices and optimal modulation of optical interactions. Plasmonic nanocavities integrated with gain can generate coherent light at subwavelength scales, beyond the diffraction limit that constrains mode volumes in dielectric cavities such as semiconducting nanowires. However, insufficient gain with respect to losses and thermal instabilities in nanocavities has limited all nanoscale lasers to pulsed pump sources and/or low-temperature operation. Here, we show continuous-wave upconverting lasing at room temperature with record-low thresholds and high photostability from subwavelength plasmons. We achieve selective, single-mode lasing from Yb 3+ /Er 3+ -co-doped upconverting nanoparticles conformally coated on Ag nanopillar arrays that support a single, sharp lattice plasmon cavity mode and greater than wavelength λ/20 field confinement in the vertical dimension. The intense electromagnetic near-fields localized in the vicinity of the nanopillars result in a threshold of 70 W cm -2 , orders of magnitude lower than other small lasers. Our plasmon-nanoarray upconverting lasers provide directional, ultra-stable output at visible frequencies under near-infrared pumping, even after six hours of constant operation, which offers prospects in previously unrealizable applications of coherent nanoscale light.

36 MATERIALS SCIENCE↗

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy

Brachytherapy dose calculations based on point kernel superposition using the collapsed cone method have been shown to accurately model the influence from finite dimensions of the patient and effects from heterogeneities including those of high atomic numbers. The collapsed cone method is for brachytherapy applications most effectively implemented through a successive-scattering approach, in which the dose from once and higher order of scattered photons is calculated separately and in successive scatter order. The calculation speed achievable is directly proportional to the number of directions used for point kernel discretization and to the number of voxels in the volume. In this work we investigate how to best divide the total number of directions between the two steps of successive-scattering dose calculations. Results show that the largest fraction of the total number of directions should be utilized in calculating the first-scatter dose. Also shown is how the number of directions required for keeping discretization artifacts at acceptably low levels decreases significantly in multiple-source configurations, as a result of the dose gradients being less steep than those around single sources. Investigating the number of kernel directions required to keep artifacts low enough within the high dose region of an implant (i.e., for dose levels above approximately 5%-10% of the mean central target dose) reveals similar figures for brachytherapy as for external beam applications, where collapsed cone superposition is clinically used. Also shown is that approximating point kernels with their isotropic average leads to small dose differences at low and intermediate energies, implying that the collapsed cone calculations can be done in a single operation common to all sources of the implant at these energies. The current findings show that collapsed cone calculations can be achieved for brachytherapy with the same efficiency as for external beams. This, combined with recent results on gains in efficiency through implementing the algorithm on graphical card parallel hardware indicates that dose can be calculated with account for heterogeneities and finite dimensions within a few seconds for large voxel arrays and is therefore of interest for practical application to treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of the Hard X-Ray Source Dominating the E > 25 keV Emission of the Nearby Galaxy M31

We report the identification of a bright hard X-ray source dominating the M31 bulge above 25 keV from a simultaneous NuSTAR–Swift observation. We find that this source is the counterpart to Swift J0042.6+4112, which was previously detected in the Swift BAT All-sky Hard X-ray Survey. This Swift BAT source had been suggested to be the combined emission from a number of point sources; our new observations have identified a single X-ray source from 0.5 to 50 keV as the counterpart for the first time. In the 0.5–10 keV band, the source had been classified as an X-ray Binary candidate in various Chandra and XMM-Newton studies; however, since it was not clearly associated with Swift J0042.6+4112, the previous E < 10 keV observations did not generate much attention. This source has a spectrum with a soft X-ray excess (kT ∼ 0.2 keV) plus a hard spectrum with a power law of Γ∼1 and a cutoff around 15–20 keV, typical of the spectral characteristics of accreting pulsars. Unfortunately, any potential pulsation was undetected in the NuSTAR data, possibly due to insufficient photon statistics. The existing deep HST images exclude high-mass (>3 M{sub ⊙}) donors at the location of this source. The best interpretation for the nature of this source is an X-ray pulsar with an intermediate-mass (<3 M{sub ⊙}) companion or a symbiotic X-ray binary. We discuss other possibilities in more detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification of the Hard X-Ray Source Dominating the E>25 keV Emission of the Nearby Galaxy M31

We report the identification of a bright hard X-ray source dominating the M31 bulge above 25 keV from a simultaneous NuSTAR-Swift observation. We find that this source is the counterpart to Swift J0042.6+4112, which was previously detected in the Swift BAT All-sky Hard X-ray Survey. This Swift BAT source had been suggested to be the combined emission from a number of point sources; our new observations have identified a single X-ray source from 0.5 to 50 keV as the counterpart for the first time. In the 0.5-10 keV band, the source had been classified as an X-ray Binary candidate in various Chandra and XMM-Newton studies; however, since it was not clearly associated with Swift J0042.6+4112, the previous E<10 keV observations did not generate much attention. This source has a spectrum with a soft X-ray excess (kT ∼ 0.2 keV) plus a hard spectrum with a power law of G ~ 1 and a cutoff around 15-20 keV, typical of the spectral characteristics of accreting pulsars. Unfortunately, any potential pulsation was undetected in the NuSTAR data, possibly due to insufficient photon statistics. The existing deep HST images exclude high-mass (>3 solar mass) donors at the location of this source. The best interpretation for the nature of this source is an X-ray pulsar with an intermediate-mass (<3 solar mass) companion or a symbiotic X-ray binary. We discuss other possibilities in more detail.

Yukita, M.↗

High-Efficiency Flexible Multilevel Photon Sieves by Single-Step Laser-Based Fabrication and Optical Analysis

Over the past several decades, the need for high-resolution, high-efficiency, lightweight, high contrast focusing optics has continued to increase due to their applications in fields such as astronomy, spectroscopy, free-space optical communications, defense, and remote sensing. In recent years, photon sieve planar diffractive optics have been developed on flexible, lightweight polyimide substrates. However, transmission efficiencies have continuously been very low (~1-4%), thus impeding the widespread use of photon sieves in practical applications. Here, we present a flexible, lightweight, N = 4 level phase photon sieve with over 25% transmission efficiency; nearly triple that of any other photon sieve reported thus far. In this study, the photon sieve was fabricated via a novel pulsed laser ablation method using an ultraviolet source, and the total time to fabricate a ~3 sq cm sample was tens of seconds. Theoretical analysis of the photon sieve was carried out via the FDTD method, and was in very good agreement with experimental results. We also calculated via FDTD modeling the behavior of higher step (N = 8, 16, 32) photon sieves for further enhanced efficiencies, and show a fundamental limit on photon sieve efficiency of 70% in the limit of increasing step number. This multilevel photon sieve represents a new step in high-resolution diffractive optics, moving towards efficiencies suitable for widespread applications.

Julian, Matthew N.↗

FPGA-based gating and logic for multichannel single photon counting

We present results characterizing multichannel InGaAs single photon detectors utilizing gated passive quenching circuits (GPQC), self-differencing techniques, and field programmable gate array (FPGA)-based logic for both diode gating and coincidence counting. Utilizing FPGAs for the diode gating frontend and the logic counting backend has the advantage of low cost compared to custom built logic circuits and current off-the-shelf detector technology. Further, FPGA logic counters have been shown to work well in quantum key distribution (QKD) test beds. Our setup combines multiple independent detector channels in a reconfigurable manner via an FPGA backend and post processing in order to perform coincidence measurements between any two or more detector channels simultaneously. Using this method, states from a multi-photon polarization entangled source are detected and characterized via coincidence counting on the FPGA. Photons detection events are also processed by the quantum information toolkit for application testing (QITKAT)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for axionlike time-dependent cosmic birefringence with data from SPT-3G

Ultralight axionlike particles (ALPs) are compelling dark matter candidates because of their potential to resolve small-scale discrepancies between Λ CDM predictions and cosmological observations. Axion-photon coupling induces a polarization rotation in linearly polarized photons traveling through an ALP field; thus, as the local ALP dark matter field oscillates in time, distant static polarized sources will appear to oscillate with a frequency proportional to the ALP mass. We use observations of the cosmic microwave background from SPT-3G, the current receiver on the South Pole Telescope, to set upper limits on the value of the axion-photon coupling constant g φ γ over the approximate mass range 10 - 22 – 10 - 19 eV , corresponding to oscillation periods from 12 hours to 100 days. For periods between 1 and 100 days ( 4.7 × 10 - 22 eV ≤ m φ ≤ 4.7 × 10 - 20 eV ), where the limit is approximately constant, we set a median 95% C.L. upper limit on the amplitude of on-sky polarization rotation of 0.071 deg. Assuming that dark matter comprises a single ALP species with a local dark matter density of 0.3 GeV / cm 3 , this corresponds to g φ γ < 1.18 × 10 - 12 GeV - 1 × ( m φ 1.0 × 10 - 21 eV ) . These new limits represent an improvement over the previous strongest limits set using the same effect by a factor of ~ 3.8 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fundamentals and Applications of Hybrid LWFA-PWFA

Fundamental similarities and differences between laser-driven plasma wakefield acceleration (LWFA) and particle-driven plasma wakefield acceleration (PWFA) are discussed. The complementary features enable the conception and development of novel hybrid plasma accelerators, which allow previously not accessible compact solutions for high quality electron bunch generation and arising applications. Very high energy gains can be realized by electron beam drivers even in single stages because PWFA is practically dephasing-free and not diffraction-limited. These electron driver beams for PWFA in turn can be produced in compact LWFA stages. In various hybrid approaches, these PWFA systems can be spiked with ionizing laser pulses to realize tunable and high-quality electron sources via optical density downramp injection (also known as plasma torch) or plasma photocathodes (also known as Trojan Horse) and via wakefield-induced injection (also known as WII). These hybrids can act as beam energy, brightness and quality transformers, and partially have built-in stabilizing features. They thus offer compact pathways towards beams with unprecedented emittance and brightness, which may have transformative impact for light sources and photon science applications. Furthermore, they allow the study of PWFA-specific challenges in compact setups in addition to large linac-based facilities, such as fundamental beam–plasma interaction physics, to develop novel diagnostics, and to develop contributions such as ultralow emittance test beams or other building blocks and schemes which support future plasma-based collider concepts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LASER TECHNOLOGY FOR PRECISION MONOENERGETIC GAMMA-RAY SOURCE R&D AT LLNL

Generation of mono-energetic, high brightness gamma-rays requires state of the art lasers to both produce a low emittance electron beam in the linac and high intensity, narrow linewidth laser photons for scattering with the relativistic electrons. Here, we overview the laser systems for the 3rd generation Monoenergetic Gamma-ray Source (MEGa-ray) currently under construction at Lawrence Livermore National Lab (LLNL). We also describe a method for increasing the efficiency of laser Compton scattering through laser pulse recirculation. The fiber-based photoinjector laser will produce 50 {micro}J temporally and spatially shaped UV pulses at 120 Hz to generate a low emittance electron beam in the X-band RF photoinjector. The interaction laser generates high intensity photons that focus into the interaction region and scatter off the accelerated electrons. This system utilizes chirped pulse amplification and commercial diode pumped solid state Nd:YAG amplifiers to produce 0.5 J, 10 ps, 120 Hz pulses at 1064 nm and up to 0.2 J after frequency doubling. A single passively mode-locked Ytterbium fiber oscillator seeds both laser systems and provides a timing synch with the linac.

42 ENGINEERING↗

Electronic and optical properties of transition metal impurities in GaN and AlN

The optical properties of Cr(III) impurities are well studied and exploited in 𝛼−Al 2 ⁢O 3 , which enables ruby lasers. Photoluminescence spectra resembling the famous 1.78 eV emission of Cr in 𝛼−Al 2 ⁢O 3 have been observed in other wide-band-gap host materials, in particular AlN. However, it is unclear whether Cr would produce the same emission in the nitrides as in 𝛼−Al 2 ⁢O 3 , especially given the different local environment (tetrahedral vs octahedral coordination). We investigate the electronic and optical properties of transition metal substitutional impurities (Cr, Co, Ni, and Cu) in wurtzite GaN and AlN from first principles, utilizing hybrid density functional theory. We calculate the optical transition energies using a constrained occupation approach that accounts for the multideterminant nature of the excited states. Our results indicate that substitutional Cr(III) is not responsible for the emission near 1.78 eV observed in the nitrides. Among the examined impurities, only substitutional Co(II) produces emission near 1.78 eV. Based on the favorable properties of Co(II) (low formation energy, small Huang-Rhys factor, and an 𝑆 = 3/2 ground state) we propose it as a promising single-photon emitter or spin qubit. We additionally assign the PL peak observed near 1.05 eV in GaN and AlN to the 2 𝐸→ 4 𝐴 2 transition of the Ni(III) substitution.

36 MATERIALS SCIENCE↗

Using SPHINX Accelerator to Measure Heat Transfer in Metal Foils [Slides]

Experiments on the SPHINX accelerator at Sandia National Laboratories (SNL) looked at electron beam heating of metal foils used in Bremsstrahlung flash x-ray production. Titanium and tantalum foils were exposed to electron beam energies of up to 2MeV to determine surface heating. As part of the experiment, the x-ray dose profiles were characterized using a scintillating panel (EJ-230) placed both perpendicular and parallel to the photon beam. This was followed by direct electron beam imaging using a fast-gated ICCD camera and a fused silica Cherenkov witness plate. Once characterized, the foil was directly measured using a mid-wave (3-5 micron) infrared camera (MWIR) to determine the peak surface temperatures and spatially-resolved thermal profiles. Additionally, an IR pyrometer was used in a single wavelength mode (2.3 µm) to determine localized surface temperatures as well. Results are compared with calculations of surface temperatures obtained from e-beam energy depositions combined with the specific heats of the foils. This is the first attempt to directly measure the surface temperature profile on a short-pulse (10 nanoseconds) flash x-ray source using MWIR imaging. These data are directly relevant for Monte Carlo/Integrated Tiger Series electron/photon transport code results being used in the design of future Bremsstrahlung sources such as CREST.

43 PARTICLE ACCELERATORS↗

Integrated quantum optical phase sensor in thin film lithium niobate

Abstract The quantum noise of light, attributed to the random arrival time of photons from a coherent light source, fundamentally limits optical phase sensors. An engineered source of squeezed states suppresses this noise and allows phase detection sensitivity beyond the quantum noise limit (QNL). We need ways to use quantum light within deployable quantum sensors. Here we present a photonic integrated circuit in thin-film lithium niobate that meets these requirements. We use the second-order nonlinearity to produce a squeezed state at the same frequency as the pump light and realize circuit control and sensing with electro-optics. Using 26.2 milliwatts of optical power, we measure (2.7 ± 0.2)% squeezing and apply it to increase the signal-to-noise ratio of phase measurement. We anticipate that photonic systems like this, which operate with low power and integrate all of the needed functionality on a single die, will open new opportunities for quantum optical sensing.

47 OTHER INSTRUMENTATION↗

Unraveling the origin of air-stability in single-crystalline layered oxide positive electrode materials

Single-crystalline Ni-rich layered oxides present compelling advantages over conventional polycrystalline counterparts toward large-scale applications, including enhanced mechanical stability and higher energy density. Nevertheless, the deleterious effects of air exposure, which is inevitable in industrial processing, on their structure and electrochemical performance remain poorly understood. Herein, we reveal that air exposure is more detrimental to the electrochemical performance of single-crystalline layered oxide positive electrodes than polycrystalline counterparts. It is found that air-induced surface structural distortions are primarily responsible for the electrochemical performance decay of single-crystalline samples rather than the generally believed surface residual lithium. Leveraging multiscale diffraction and imaging techniques, we identify an undesirable structural transition to a metastable O1* phase, which introduces substantial lattice defects and localized strain concentrations within the layered structure. These adverse structural evolutions compromise structural integrity and promote crack initiation during electrochemical cycling, ultimately accelerating capacity fade. Our findings provide critical insights into the air-induced degradation mechanisms and emphasize the urgent need for developing effective stabilization strategies to facilitate the commercial implementation of single-crystalline Ni-rich positive electrodes.

36 MATERIALS SCIENCE↗

Progenitors of type Ia supernovae in elliptical galaxies

Although there is a nearly universal agreement that type Ia supernovae are associated with the thermonuclear disruption of a CO white dwarf, the exact nature of their progenitors is still unknown. The single degenerate scenario envisages a white dwarf accreting matter from a non-degenerate companion in a binary system. Nuclear energy of the accreted matter is released in the form of electromagnetic radiation or gives rise to numerous classical nova explosions prior to the supernova event. We show that combined X-ray output of supernova progenitors and statistics of classical novae predicted in the single degenerate scenario are inconsistent with X-ray and optical observations of nearby early type galaxies and galaxy bulges. White dwarfs accreting from a donor star in a binary system and detonating at the Chandrasekhar mass limit can account for no more than {approx}5% of type Ia supernovae observed in old stellar populations.

79 ASTRONOMY AND ASTROPHYSICS↗

R-matrix approach with proper boundary conditions for dissipative and nondissipative collision processes

We develop an R-matrix approach to treating collision processes which explicitly takes into account, by means of a simple energy-dependent analytic function, the out-of-phase oscillations of the incident and scattered standing waves in the interior region. Thereby we avoid the use of the Bloch operator. In place of the Bloch operator the incident wave provides the source term in an inhomogeneous equation for the scattered wave. We take those subchannels not treated exactly into account via the optical potential, which is generally non-Hermitian due to dissipation at the boundary. The optical potential is constructed on a real analytic basis using a resolvent that satisfies outgoing-wave boundary conditions. The use of an analytic basis together with the direct determination of the K matrix, rather than the R matrix, at the boundary (this is done by matching the interior wave function to the nearly exact analytic solution beyond the boundary) makes the method particularly well suited to the treatment of ultracold collisions. We have tested our method by applying it to one-photon single-ionization of (He1s{sup 2}) accompanied by excitation to He{sup +}(2s) or He{sup +}(2p) for photon energies above the complete breakup threshold, where the optical potential is non-Hermitian. Excellent agreement with experiment is obtained for the cross sections for photoionization to both He{sup +} (n=1) and to He{sup +} (n=2). The 2s-to-2p branching ratio is strongly influenced by both the optical potential and, at photon energies less than a few tens of eV above the breakup threshold, the nonadiabatic dipole mixing of the 2s and 2p states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Importance of bulk excitations and coherent electron-photon-phonon scattering in photoemission from PbTe(111): Ab initio theory with experimental comparisons

This paper presents a fully ab initio many-body photoemission framework that includes coherent three-body electron-photon-phonon scattering to predict the transverse momentum distributions and the mean transverse energies (MTEs) of bulk photoelectrons from single-crystal photocathodes. The need to develop such a theory stems from the lack of studies that provide complete understanding of the underlying fundamental processes governing the transverse momentum distribution of photoelectrons emitted from single crystals. For example, initial predictions based on density-functional theory calculations of effective electron masses suggested that the (111) surface of PbTe would produce very small MTEs (≤ 15 meV), whereas our experiments yielded MTEs ten to twenty times larger than these predictions and also exhibited a lower photoemission threshold than predicted. The ab initio framework presented in this paper correctly reproduces both the magnitude of the MTEs from our measurements in PbTe(111) and the observed photoemission below the predicted threshold. Our results show that both photoexcitations into states that propagate in the bulk of the material and coherent many-body electron-photon-phonon scattering processes, which initial predictions ignored, play surprisingly important roles in photoemission from PbTe(111). Lastly, from the lessons learned, we recommend a procedure for rapid computational screening of potential single-crystal photocathodes for applications in next-generation ultrafast electron diffraction and X-ray free-electron lasers, which will enable significant advances in condensed matter research.

36 MATERIALS SCIENCE↗