Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Kinetic Monte Carlo simulations of aging in δ -Pu

We have developed a first-passage kinetic Monte Carlo approach for materials aging to investigate the sensitivity of void swelling to model parameters, including helium bubble density and size distribution. In addition to explicitly accounting for the spatial distribution of individual point defects, bubbles, and voids, our approach can simulate total doses equivalent to 100 years of natural aging on statistically representative volumes of materials. This technique enables us to study the effects on swelling and radiation damage evolution due to temperature and dose rate (as altered in artificially aged experiments), differences in effective interaction radii between vacancies and interstitials, and varying defect diffusion activation energies, while providing more detailed information than previous rate-equation based approaches. In conclusion, our results indicate that spatial effects that are not modeled in mean-field rate theories could play a significant role in void swelling initiation and growth for certain regimes of model parameters.

Actinides↗

Impact of Satellite Viewing-Swath Width on Global and Regional Aerosol Optical Thickness Statistics and Trends

We use the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite aerosol optical thickness (AOT) product to assess the impact of reduced swath width on global and regional AOT statistics and trends. Alongtrack and across-track sampling strategies are employed, in which the full MODIS data set is sub-sampled with various narrow-swath (approximately 400-800 km) and single pixel width (approximately 10 km) configurations. Although view-angle artifacts in the MODIS AOT retrieval confound direct comparisons between averages derived from different sub-samples, careful analysis shows that with many portions of the Earth essentially unobserved, spatial sampling introduces uncertainty in the derived seasonal-regional mean AOT. These AOT spatial sampling artifacts comprise up to 60%of the full-swath AOT value under moderate aerosol loading, and can be as large as 0.1 in some regions under high aerosol loading. Compared to full-swath observations, narrower swath and single pixel width sampling exhibits a reduced ability to detect AOT trends with statistical significance. On the other hand, estimates of the global, annual mean AOT do not vary significantly from the full-swath values as spatial sampling is reduced. Aggregation of the MODIS data at coarse grid scales (10 deg) shows consistency in the aerosol trends across sampling strategies, with increased statistical confidence, but quantitative errors in the derived trends are found even for the full-swath data when compared to high spatial resolution (0.5 deg) aggregations. Using results of a model-derived aerosol reanalysis, we find consistency in our conclusions about a seasonal-regional spatial sampling artifact in AOT Furthermore, the model shows that reduced spatial sampling can amount to uncertainty in computed shortwave top-ofatmosphere aerosol radiative forcing of 2-3 W m(sup−2). These artifacts are lower bounds, as possibly other unconsidered sampling strategies would perform less well. These results suggest that future aerosol satellite missions having significantly less than full-swath viewing are unlikely to sample the true AOT distribution well enough to obtain the statistics needed to reduce uncertainty in aerosol direct forcing of climate.

remote sensing↗

Spatial inventory integrating raster databases and point sample data

A timber inventory of the Eldorado National Forest, located in east-central California, provides an example of the use of a Geographic Information System (GIS) to stratify large areas of land for sampling and the collection of statistical data. The raster-based GIS format of the VICAR/IBIS software system allows simple and rapid tabulation of areas, and facilitates the selection of random locations for ground sampling. Algorithms that simplify the complex spatial pattern of raster-based information, and convert raster format data to strings of coordinate vectors, provide a link to conventional vector-based geographic information systems.

Strahler, A. H.↗

Quantified fracture (joint) clustering in Archean basement, Wyoming: application of the normalized correlation count method

We demonstrate statistically significant self-organized clustering over a length scale range from 10 -2 to 10 1 m for north-striking opening-mode fractures (joints) in Late Archean Mount Owen Quartz Monzonite. Spatial arrangement is a critical fracture network attribute that until recently has only been assessed qualitatively. We use normalized fracture intensity plots and the normalized correlation count (NCC) method of Marrett et al. to discriminate clustered from randomly placed or evenly spaced patterns quantitatively over a wide range of length scales and to test the statistical significance of the resulting patterns. We propose a procedure for interpreting cluster patterns on NCC diagrams generated by the freely available spatial analysis software CorrCount. Results illustrate the efficacy of NCC to measure fracture clustering patterns in texturally homogeneous Archean granitic rock in a setting distant (>2 km) from folds or faults. In their current geological setting, these regional fractures are conduits for water flow and their patterns – and the NCC approach to defining clusters – may be useful guides to the spatial arrangement style and clustering magnitude of conductive fractures in other, less accessible fractured basement rocks.

02 PETROLEUM↗

Niche-DE: niche-differential gene expression analysis in spatial transcriptomics data identifies context-dependent cell-cell interactions

Existing methods for analysis of spatial transcriptomic data focus on delineating the global gene expression variations of cell types across the tissue, rather than local gene expression changes driven by cell-cell interactions. We propose a new statistical procedure called niche-differential expression (niche-DE) analysis that identifies cell-type-specific niche-associated genes, which are differentially expressed within a specific cell type in the context of specific spatial niches. We further develop niche-LR, a method to reveal ligand-receptor signaling mechanisms that underlie niche-differential gene expression patterns. Niche-DE and niche-LR are applicable to low-resolution spot-based spatial transcriptomics data and data that is single-cell or subcellular in resolution.

59 BASIC BIOLOGICAL SCIENCES↗

Wavelet-based surrogate time series for multiscale simulation of heterogeneous catalysis

We propose a wavelet-based scheme that encodes the essential dynamics of discrete microscale surface reactions in a form that can be coupled with continuum macroscale flow simulations with high computational efficiency. This makes it possible to simulate the dynamic behavior of reactor-scale heterogeneous catalysis without requiring detailed concurrent simulations at both the surface and continuum scales using different models. Our scheme is based on the application of wavelet-based surrogate time series that encodes the essential temporal and/or spatial fine-scale dynamics at the catalyst surface. The encoded dynamics are then used to generate statistically equivalent, randomized surrogate time series, which can be linked to the continuum scale simulation. As a result, we illustrate an application of this approach using two different kinetic Monte Carlo simulations with different characteristic behaviors typical for heterogeneous chemical reactions.

36 MATERIALS SCIENCE↗

Aquaplanets as a Framework for Examination of Aerosol Effects

Although fundamental to the planetary radiative balance, aerosol impacts are highly uncertain in climate simulations because of the uneven distribution of aerosol sources and the complex interactions with radiation and clouds that are difficult to represent in climate models. This study proposes that aquaplanet configurations represent an idealized framework to investigate aerosol effects. As a simple demonstration, a series of aquaplanet simulations with the Community Atmosphere Model version 6 shows that the spatial distribution of aerosol emissions changes the aerosol effective radiative forcing even with unchanged total emissions. Some statistical properties of the simulations are presented to show that relatively short model integrations yield robust results. Much of the aerosol effect is shown to arise from aerosol–cloud interactions, especially through rapid adjustments associated with the aerosol lifetime effect that alter the cloud optical thickness.

54 ENVIRONMENTAL SCIENCES↗

Correlative piezoresponse and micro-Raman imaging of CuInP 2 S 6 –In 4/3 P 2 S 6 flakes unravels phase-specific phononic fingerprint via unsupervised learning

Characterizing the novel properties of layered van der Waals materials is key for their application in functional devices. A better understanding of this type of material requires correlative imaging of diverse nanoscale material properties. Within this class of materials, CuInP 2 S 6 (CIPS) has received a significant degree of interest due to its ionically mediated room temperature ferroelectricity. Moreover, it is possible to form stable self-assembled heterostructures of ferroelectric CuInP 2 S 6 (CIPS) and non-ferroelectric (i.e., lacking Cu) In 4/3 P 2 S 6 (IPS) phases, by controlling the targeted composition and kinetics of synthesis. In this work, we present a correlative nanometric imaging study of the phononic modes and piezoelectricity of the phase-separated thin heteroepitaxial CIPS/IPS flakes. Here, we show that it is possible to isolate the different phononic modes of the two phases by spatially correlating them with their distinct ferroelectric behavior. The coupling of our experimental data with unsupervised learning statistical methods enables unraveling specific Raman peaks that are characteristic of each chemical phase (CIPS and IPS) present in the composite sample, discarding the less significant ones.

correlative microscopy↗

THE BARYON CENSUS IN A MULTIPHASE INTERGALACTIC MEDIUM: 30% OF THE BARYONS MAY STILL BE MISSING

Although galaxies, groups, and clusters contain {approx}10% of the baryons, many more reside in the photoionized and shocked-heated intergalactic medium (IGM) and in the circumgalactic medium (CGM). We update the baryon census in the (H I) Ly{alpha} forest and warm-hot IGM (WHIM) at 10{sup 5-6} K traced by O VI {lambda}1032, 1038 absorption. From Enzo cosmological simulations of heating, cooling, and metal transport, we improve the H I and O VI baryon surveys using spatially averaged corrections for metallicity (Z/Z {sub Sun }) and ionization fractions (f {sub HI}, f {sub OVI}). Statistically, the O VI correction product correlates with column density, (Z/Z {sub Sun })f {sub OVI} Almost-Equal-To (0.015)(N {sub OVI}/10{sup 14} cm{sup -2}){sup 0.70}, with an N {sub OVI}-weighted mean of 0.01, which doubles previous estimates of WHIM baryon content. We also update the Ly{alpha} forest contribution to baryon density out to z = 0.4, correcting for the (1 + z){sup 3} increase in absorber density, the (1 + z){sup 4.4} rise in photoionizing background, and cosmological proper length dl/dz. We find substantial baryon fractions in the photoionized Ly{alpha} forest (28% {+-} 11%) and WHIM traced by O VI and broad-Ly{alpha} absorbers (25% {+-} 8%). The collapsed phase (galaxies, groups, clusters, CGM) contains 18% {+-} 4%, leaving an apparent baryon shortfall of 29% {+-} 13%. Our simulations suggest that {approx}15% reside in hotter WHIM (T {>=} 10{sup 6} K). Additional baryons could be detected in weaker Ly{alpha} and O VI absorbers. Further progress requires higher-precision baryon surveys of weak absorbers, down to minimum column densities N {sub HI} {>=} 10{sup 12.0} cm{sup -2}, N {sub OVI} {>=} 10{sup 12.5} cm{sup -2}, N {sub OVII} {>=} 10{sup 14.5} cm{sup -2}, using high signal-to-noise data from high-resolution UV and X-ray spectrographs.

79 ASTRONOMY AND ASTROPHYSICS↗

Structural studies of metastable and equilibrium vortex lattice domains in MgB 2

Abstract The vortex lattice (VL) in MgB 2 is characterized by the presence of long-lived metastable states (MSs), which arise from cooling or heating across the equilibrium phase boundaries. A return to the equilibrium configuration can be achieved by inducing vortex motion. Here we report on small-angle neutron scattering studies of MgB 2 , focusing on the structural properties of the VL as it is gradually driven from metastable to equilibrium states (ESs) by an AC magnetic field. Measurements were performed using initial MSs obtained either by cooling or heating across the equilibrium phase transition. In all cases, the longitudinal correlation length remains constant and comparable to the sample thickness. Correspondingly, the VL may be considered as a system of straight rods, where the formation and growth of ES domains only occurs in the two-dimensional plane perpendicular to the applied field direction. Spatially resolved raster scans of the sample were performed with apertures as small as 80 μ m, corresponding to only 1.2 × 10 6 vortices for an applied field of 0.5 T. These revealed spatial variations in the metastable and equilibrium VL populations, but individual domains were not directly resolved. A statistical analysis of the data indicates an upper limit on the average domain size of approximately 50 μ m.

Louden, E. R.↗

Prospects for annihilating Dark Matter towards Milky Way's dwarf galaxies by the Cherenkov Telescope Array

We derive the Cherenkov Telescope Array (CTA) sensitivity to dark matter (DM) annihilation in several primary channels, over a broad range of DM masses. These sensitivities are estimated when CTA is pointed towards a large sample of Milky Way's dwarf spheroidal galaxies (dSphs) with promising J -factors and small statistical uncertainties. This analysis neglects systematic uncertainties, which we estimate at the level of at least 1 dex. We also present sensitivities on the annihilation cross section from a combined analysis of 4 dSphs. We assess the CTA sensitivity by: i ) using, for each dSph, a recent determination of the J -factor and its statistical error; ii ) considering the most up-to-date cosmic ray background; and iii ) including both spatial and spectral terms in the likelihood analysis. We find that a joint spectral and spatial analysis improves the CTA sensitivity, in particular for primary channels with sharp features in the γ-ray energy spectrum and for dSphs with steep J -factor profiles, as deduced from the internal kinematics. The greatest sensitivities are obtained for observations of Ursa Minor among the classical dSphs and of Ursa Major II for ultra-faint dSphs.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter constraints from a joint analysis of dwarf Spheroidal galaxy observations with VERITAS

We present constraints on the annihilation cross section of weakly interacting massive particles dark matter based on the joint statistical analysis of four dwarf galaxies with VERITAS. These results are derived from an optimized photon weighting statistical technique that improves on standard imaging atmospheric Cherenkov telescope (IACT) analyses by utilizing the spectral and spatial properties of individual photon events.

79 ASTRONOMY AND ASTROPHYSICS↗

First observations of solar halo gamma rays over a full solar cycle

We analyze 15 years of Fermi-LAT data and produce a detailed model of the Sun’s inverse-Compton scattering emission (solar halo), which is powered by interactions between ambient cosmic-ray electrons and positrons with sunlight. By developing a novel analysis method to analyze moving sources, we robustly detect the solar halo at energies between 31.6 MeV and 100 GeV, and angular extensions up to 45° from the Sun, providing new insight into spatial regions where there are no direct measurements of the Galactic cosmic-ray flux. The large statistical significance of our signal allows us to subdivide the data and provide the first 𝛾-ray probes into the time variation and azimuthal asymmetry of the solar modulation potential, finding time-dependent changes in solar modulation both parallel and perpendicular to the ecliptic plane. Our results are consistent with (but with independent uncertainties from) local cosmic-ray measurements, unlocking new probes into astrophysical processes near the solar surface.

79 ASTRONOMY AND ASTROPHYSICS↗

MultiLoad-GAN: A GAN-Based Synthetic Load Group Generation Method Considering Spatial-Temporal Correlations

This paper presents a deep-learning framework, Multi-load Generative Adversarial Network (MultiLoad-GAN), for generating a group of synthetic load profiles (SLPs) simultaneously. The main contribution of MultiLoad-GAN is the capture of spatial-temporal correlations among a group of loads that are served by the same distribution transformer. This enables the generation of a large amount of correlated SLPs required for microgrid and distribution system studies. Here, the novelty and uniqueness of the MultiLoad-GAN framework are three-fold. First, to the best of our knowledge, this is the first method for generating a group of load profiles bearing realistic spatial- temporal correlations simultaneously. Second, two complementary realisticness metrics for evaluating generated load profiles are developed: computing statistics based on domain knowledge and comparing high-level features via a deep-learning classifier. Third, to tackle data scarcity, a novel iterative data augmentation mechanism is developed to generate training samples for enhancing the training of both the classifier and the MultiLoad-GAN model. Simulation results show that MultiLoad- GAN can generate more realistic load profiles than existing approaches, especially in group level characteristics. With little finetuning, MultiLoad-GAN can be readily extended to generate a group of load or PV profiles for a feeder or a service area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TU-G-201-00: Imaging Equipment Specification and Selection in Radiation Oncology Departments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-02: An MRI Simulator From Proposal to Operation

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-03: Imaging Systems in Radiotherapy: Buying, Installing, and Using

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗