Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Compartment Venting Analyses of Ares I First Stage Systems Tunnel

Compartment venting analyses have been performed for the Ares I first stage systems tunnel using both the lumped parameter method and the three-dimensional (31)) transient computational fluid dynamics (CFD) approach. The main objective of venting analyses is to predict the magnitudes of differential pressures across the skin so the integrity of solid walls can be evaluated and properly designed. The lumped parameter method assumes the gas pressure and temperature inside the systems tunnel are spatially uniform, which is questionable since the tunnel is about 1,700 in. long and 4 in. wide. Therefore, 31) transient CFD simulations using the commercial CFD code FLUENT are performed in order to examine the gas pressure and temperature variations inside the tunnel. It was found that the uniform pressure and temperature assumptions inside the systems tunnel are valid during ascent. During reentry, the uniform pressure assumption is also reasonable but the uniform temperature assumption is not valid. Predicted pressure and temperature inside the systems tunnel using CFD are also compared with those from the lumped parameter method using the NASA code CHCHVENT. In general, the average pressure and temperature inside the systems tunnel from CFD are between the burst and crush results from CHCHVENT during both ascent and reentry. The skin differential pressure and pressure inside the systems tunnel relative to freestream pressure from CHCHVENT as well as velocity vectors and streamlines are also discussed in detail.

Wang, Qunzhen↗

Adaptive tau-leaping methods for microscopic-lattice kinetic Monte Carlo simulations

Traditional Kinetic Monte Carlo (KMC) approaches, rooted in Gillespie’s stochastic simulation algorithm, become computationally demanding in systems with a large range of timescales. The goal of this work is to propose and study new adaptive lattice-KMC time integration strategies for spatially non-uniform systems. To that end, two novel adaptive tau-leaping methods and their corresponding time integration strategies are developed based on the idea of the “n-fold” direct KMC method. These strategies allow for the simultaneous execution of multiple reactions, advancing time by adaptively selected coarse increments. We present numerical experiments comparing the proposed methods with existing approaches in a catalytic surface kinetics application involving ammonia decomposition.

Bimolecular reactions↗

SMAnalytics Automated Shape Memory Test Analysis Software User's Manual: UCFTC, UPER, and DSC Test Methods, Version 1.0.2

Over the course of 60 years of shape memory alloy research and development, the properties of these alloys have been measured using various testing methods, which are often customized by the organization performing the test. However, commercial adoption of shape memory alloys in aeronautic actuator applications requires reducing property uncertainty through standardizing test methods. Historically, differential scanning calorimetry (DSC) has been used to measure transformation temperatures under stress-free conditions. This testing method is well established, and tests are run under the applicable standard, ASTM F2004-17: Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis. Two other test methods for measuring strains and transformation temperatures under constant load or free recovery after prestraining have only recently been standardized—ASTM E3097: Standard Test Method for Mechanical Uniaxial Constant Force Thermal Cycling of SMAs (UCFTC) and ASTM E3098: Standard Test Method for Mechanical Uniaxial Pre-Strain and Thermal Free Recovery of SMAs (UPFR). These standards represent a critical step forward in producing reliable material property data for the use of these alloys in aeronautics and other commercial areas. However, no standard programs or software packages were previously available for postprocessing UCFTC- and UPFR-type test data to extract property data. Each organization that performed the testing analyzed data using its own custom manual methods, such as using a plot and a straight edge, spreadsheet plotting methods, or custom code routines, to extract the required values for strains, stresses, and transformation temperatures. SMAnalytics represents the first publicly available uniform software package for processing data generated using the DSC, UCFTC, and UPFR test methods, as well as many modifications of these methods, including loading in martensite versus austenite and performing multiple thermal cycles at stress. In doing so, it provides a tool for reducing potential error or variability in the measured values due to the precision of the technique used and person-to-person variability. It is also expected that this automated data-parsing tool can accelerate the data analysis phase of the test campaign, especially for large data files. This User’s Manual describes how the SMAnalytics software works and the method for its use.

Shape Memory Alloy↗

U{sub N} Method For The Critical Slab Problem In One-Speed Neutron Transport Theory

The Chebyshev polynomial approximation (U{sub N} method) is used to solve the critical slab problem in one-speed neutron transport theory using Marshak boundary condition. The isotropic scattering kernel with the combination of forward and backward scattering is chosen for the neutrons in a uniform finite slab. Numerical results obtained by the U{sub N} method are presented in the tables together with the results obtained by the well-known P{sub N} method for comparison. It is shown that the method converges rapidly with its easily executable equations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

METHODS FOR DETERMINING AGITATOR MIXING REQUIREMENTS FOR A MIXING & SAMPLING FACILITY TO FEED WTP (WASTE TREATMENT PLANT)

The following report is a summary of work conducted to evaluate the ability of existing correlative techniques and alternative methods to accurately estimate impeller speed and power requirements for mechanical mixers proposed for use in a mixing and sampling facility (MSF). The proposed facility would accept high level waste sludges from Hanford double-shell tanks and feed uniformly mixed high level waste to the Waste Treatment Plant. Numerous methods are evaluated and discussed, and resulting recommendations provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Variational Calculations for the Nuclear Equation of State toward Supernova Simulations

We construct an equation of state (EOS) for uniform nuclear matter at zero and finite temperatures with the variational method starting from the realistic nuclear Hamiltonian composed of the AV18 two-body potential and the UIX three-body interaction. Using the obtained EOS, we perform the Thomas-Fermi calculation of atomic nuclei, and tune adjustable parameters in the EOS for uniform matter to reproduce empirical data of {beta}-stable nuclei, toward a nuclear EOS table for supernova simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Facile approach to prepare hollow core–shell NiO microspherers for supercapacitor electrodes

A facile lamellar template method (see image) has been developed for the preparation of uniform hollow core–shell structure NiO (HCS–NiO) with a nanoarchitectured wall structure. The prepared NiO was found to be highly crystalline in uniform microstructures with high specific surface area and pore volume. The results indicated that ethanol interacted with trisodium citrate played an important role for the formation of hollow core–shell spheres. On the basis of the analysis of the composition and the morphology, a possible formation mechanism was investigated. NiO microspheres with hollow core–shell showed excellent capacitive properties. The exceptional cyclic, structural and electrochemical stability with ∼95% coulombic efficiency, and very low ESR value from impedance measurements promised good utility value of hollow core–shell NiO material in fabricating a wide range of high-performance electrochemical supercapacitors. - The hollow core–shell NiO was prepared with a facile lamellar template method. The prepared NiO show higher capacitance, lower ion diffusion resistance and better electroactive surface utilization for Faradaic reactions. - Highlights: • Formation of hollow core–shell NiO via a novel and facile precipitation route. • Exhibited uniform feature sizes and high surface area of hollow core–shell NiO. • Synthesized NiO has high specific capacitance ( 448 F g{sup 1}) and very low ESR value. • Increased 20% of long life cycles capability after 500 charge–discharge cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Irradiation-Driven Restructuring of UO 2 Thin Films: Amorphization and Crystallization

Combustion synthesis in uranyl nitrate–acetylacetone–2-methoxyethanol solutions was used to deposit thin UO 2 films on aluminum substrates to investigate the irradiation-induced restructuring processes. Thermal analysis revealed that the combustion reactions in these solutions are initiated at ~160 °C. The heat released during the process and the subsequent brief annealing at 400 °C allow the deposition of polycrystalline films with 5–10 nm UO 2 grains. The use of multiple deposition cycles enables tuning of the film thicknesses in the 35–260 nm range. Irradiation with Ar 2+ ions (1.7 MeV energy and a fluence of up to 1 × 10 17 ions/cm 2 ) is utilized to generate a uniform distribution of atomic displacements within the films. X-ray fluorescence (XRF) and alpha-particle emission spectroscopy showed that the films were stable under irradiation and did not undergo sputtering degradation. X-ray photoelectron spectroscopy (XPS) showed that the stoichiometry and uranium ionic concentrations remain stable during irradiation. The high-resolution electron microscopy imaging and electron diffraction analysis demonstrated that at the early stages of irradiation (below 1 × 10 16 ion/cm 2 ) UO 2 films show complete amorphization and beam-induced densification (sintering), resulting in a pore-free disordered film. Prolonged irradiation (5 × 10 16 ion/cm 2 ) is shown to trigger a crystallization process at the surface of the films that moves toward the UO 2 /Al interface, converting the entire amorphous material into a highly crystalline film. This work reports on an entirely different radiation-induced restructuring of the nanoscale UO 2 compared to the coarse-grained counterpart. The preparation of thin UO 2 films deposited on Al substrates fills an area of national need within the stockpile stewardship program of the National Nuclear Security Administration and fundamental research with actinides. Here, the method reported in this work produces pure, robust, and uniform thin-film actinide targets for nuclear science measurements

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uniform magnetic fields generated by circular current-carrying coils

The study described was carried out to evaluate known systems of circular coils with a view toward their application on board the space probes Ranger 1, Ranger 2, and Explorer 10. Particular attention is given to a new method, developed during the investigation, for determining the constants of systems composed of 6 to 8 coils. Such systems were found to generate magnetic fields of very high uniformity. By using advanced computational techniques, it proved possible to evaluate the field uniformity of various systems without recourse to complex analytical methods. Means of evaluating the influence of coil dimensions on the uniformity of the field of any system are described.

Williams, V. L.↗

Linear-depth quantum circuits for loading Fourier approximations of arbitrary functions

Abstract The ability to efficiently load functions on quantum computers with high fidelity is essential for many quantum algorithms, including those for solving partial differential equations and Monte Carlo estimation. In this work, we introduce the Fourier series loader (FSL) method for preparing quantum states that exactly encode multi-dimensional Fourier series using linear-depth quantum circuits. Specifically, the FSL method prepares a (Dn)-qubit state encoding the 2 Dn -point uniform discretization of aD-dimensional function specified by aD-dimensional Fourier series. A free parameter,m, which must be less thann, determines the number of Fourier coefficients, 2 D ( m + 1 ) , used to represent the function. The FSL method uses a quantum circuit of depth at most 2 ( n − 2 ) + ⌈ log 2 ( n − m ) ⌉ + 2 D ( m + 1 ) + 2 − 2 D ( m + 1 ) , which is linear in the number of Fourier coefficients, and linear in the number of qubits (Dn) despite the fact that the loaded function’s discretization is over exponentially many (2 Dn ) points. The FSL circuit consists of at most D n + 2 D ( m + 1 ) + 1 − 1 single-qubit and D n ( n + 1 ) / 2 + 2 D ( m + 1 ) + 1 − 3 D ( m + 1 ) − 2 two-qubit gates; we present a classical compilation algorithm with runtime O ( 2 3 D ( m + 1 ) ) to determine the FSL circuit for a given Fourier series. The FSL method allows for the highly accurate loading of complex-valued functions that are well-approximated by a Fourier series with finitely many terms. We report results from noiseless quantum circuit simulations, illustrating the capability of the FSL method to load various continuous 1D functions, and a discontinuous 1D function, on 20 qubits with infidelities of less than 10 −6 and 10 −3 , respectively. We also demonstrate the practicality of the FSL method for near-term quantum computers by presenting experiments performed on the Quantinuum H1-1 and H1-2 trapped-ion quantum computers: we loaded a complex-valued function on 3 qubits with a fidelity of over 95 % , as well as various 1D real-valued functions on up to 6 qubits with classical fidelities ≈99%, and a 2D function on 10 qubits with a classical fidelity ≈94%.

Physics↗

SU-G-JeP3-10: Update On a Real-Time Treatment Guidance System Using An IR Navigation System for Pleural PDT

Purpose: Photodynamic therapy (PDT) is used in conjunction with surgical debulking of tumorous tissue during treatment for pleural mesothelioma. One of the key components of effective PDT is uniform light distribution. Currently, light is monitored with 8 isotropic light detectors that are placed at specific locations inside the pleural cavity. A tracking system with real-time feedback software can be utilized to improve the uniformity of light in addition to the existing detectors. Methods: An infrared (IR) tracking camera is used to monitor the movement of the light source. The same system determines the pleural geometry of the treatment area. Software upgrades allow visualization of the pleural cavity as a two-dimensional volume. The treatment delivery wand was upgraded for ease of light delivery while incorporating the IR system. Isotropic detector locations are also displayed. Data from the tracking system is used to calculate the light fluence rate delivered. This data is also compared with in vivo data collected via the isotropic detectors. Furthermore, treatment volume information will be used to form light dose volume histograms of the pleural cavity. Results: In a phantom study, the light distribution was improved by using real-time guidance compared to the distribution when using detectors without guidance. With the tracking system, 2D data can be collected regarding light fluence rather than just the 8 discrete locations inside the pleural cavity. Light fluence distribution on the entire cavity can be calculated at every time in the treatment. Conclusion: The IR camera has been used successfully during pleural PDT patient treatment to track the motion of the light source and provide real-time display of 2D light fluence. It is possible to use the feedback system to deliver a more uniform dose of light throughout the pleural cavity.

60 APPLIED LIFE SCIENCES↗

Use of internal scintillator radioactivity to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

Purpose: Positron emission tomography (PET) detectors that use a dual-ended-scintillator readout to measure depth-of-interaction (DOI) must have an accurate DOI function to provide the relationship between DOI and signal ratios to be used for detector calibration and recalibration. In a previous study, the authors used a novel and simple method to accurately and quickly measure DOI function by irradiating the detector with an external uniform flood source; however, as a practical concern, implementing external uniform flood sources in an assembled PET system is technically challenging and expensive. In the current study, therefore, the authors investigated whether the same method could be used to acquire DOI function from scintillator-generated (i.e., internal) radiation. The authors also developed a method for calibrating the energy scale necessary to select the events within the desired energy window. Methods: The authors measured the DOI function of a PET detector with lutetium yttrium orthosilicate (LYSO) scintillators. Radiation events originating from the scintillators' internal Lu-176 beta decay were used to measure DOI functions which were then compared with those measured from both an external uniform flood source and an electronically collimated external point source. The authors conducted these studies with several scintillators of differing geometries (1.5 x 1.5 and 2.0 x 2.0 mm{sup 2} cross-section area and 20, 30, and 40 mm length) and various surface finishes (mirror-finishing, saw-cut rough, and other finishes in between), and in a prototype array. Results: All measured results using internal and external radiation sources showed excellent agreement in DOI function measurement. The mean difference among DOI values for all scintillators measured from internal and external radiation sources was less than 1.0 mm for different scintillator geometries and various surface finishes. Conclusions: The internal radioactivity of LYSO scintillators can be used to accurately measure DOI function in PET detectors, regardless of scintillator geometry or surface finish. Because an external radiation source is not needed, this method of DOI function measurement can be practically applied to individual PET detectors as well as assembled systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ polymerized succinonitrile-based solid polymer electrolytes for lithium ion batteries

Novel solid polymer electrolytes based on succinonitrile (SN) plastic crystal electrolyte (SN-PCE) and polymerized ionic liquid (PIL) has been successfully synthesized via an in-situ method. The fabricated electrolyte (PIL-SN-PCE) is uniformly inlayed into the supporting matrix of polyimide, which effectively ameliorates the mechanical properties of the electrolyte. PIL can effectively enhance the thermal stability of electrolytes up to 300 °C and mitigate the parasitic reactions between the electrolytes and the electrodes. PIL-SN-PCE exhibits a remarkable oxidation ability up to 5.4 V vs Li/Li + and a high room temperature ionic conductivity of 6.54 × 10 -4 S cm -1 . Furthermore, in-situ formed interface in PIL-SN-PCE guarantee an excellent compatibility with different electrodes, which can effectively improve the cycle stability and rate performances of both half-cells and full cells. Finally, PIL-SN-PCE is considered as a promising electrolyte for high energy density lithium-ion batteries.

25 ENERGY STORAGE↗

Path optimization by a variational reaction coordinate method. I. Development of formalism and algorithms

The development of algorithms to optimize reaction pathways between reactants and products is an active area of study. Existing algorithms typically describe the path as a discrete series of images (chain of states) which are moved downhill toward the path, using various reparameterization schemes, constraints, or fictitious forces to maintain a uniform description of the reaction path. The Variational Reaction Coordinate (VRC) method is a novel approach that finds the reaction path by minimizing the variational reaction energy (VRE) of Quapp and Bofill. The VRE is the line integral of the gradient norm along a path between reactants and products and minimization of VRE has been shown to yield the steepest descent reaction path. In the VRC method, we represent the reaction path by a linear expansion in a set of continuous basis functions and find the optimized path by minimizing the VRE with respect to the linear expansion coefficients. Improved convergence is obtained by applying constraints to the spacing of the basis functions and coupling the minimization of the VRE to the minimization of one or more points along the path that correspond to intermediates and transition states. The VRC method is demonstrated by optimizing the reaction path for the Müller-Brown surface and by finding a reaction path passing through 5 transition states and 4 intermediates for a 10 atom Lennard-Jones cluster.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single Crystalline Na 0.67 Ni 0.33 Mn 0.67 O 2 Positive Electrode Material via Molten Salt Synthesis for Sodium Ion Batteries

P2-layered Na 0.67 Ni 0.33 Mn 0.67 O 2 (NNMO) has emerged as a promising positive electrode material for sodium ion batteries due to its appealing electrochemical properties. Synthesis of polycrystalline NNMO (PC-NNMO) materials through conventional calcination of solid precursors remains the prevailing method, where heating occurs in a dry environment with air or O 2 . On the other hand, the molten salt method, where precursors are submerged in molten salt medium during calcination, emerged in recent years to be a scalable technique for more controlled crystal growth and uniform morphology in a variety of materials. Here, we utilize the molten salt method to synthesize single crystalline NNMO (SC-NNMO) materials with enhanced electrochemical properties. The SC-NNMO material exhibits an initial specific discharge capacity of 95 mAh g –1 at a 0.1C rate, retaining approximately 88.5% of its capacity after 100 cycles over a wide voltage range of 2.0–4.2 V. Furthermore, SC-NNMO maintains a capacity retention of 83.9% after 300 cycles at a 1C rate compared to 66.6% for PC-NNMO, indicating excellent long-term cycling stability. This stability is further confirmed by the performance of an SC-NNMO//hard carbon full cell, which retains 90.3% of its capacity after 200 cycles at 1C within a voltage window of 1.9–4.1 V. The enhancement in stability of the SC-NNMO sample is attributed to the single crystalline structure suppressing the undesired P2–O2 phase transition at high voltage. This study also presents an easy, efficient, and straightforward molten salt process for SC-NNMO material synthesis, offering valuable insights into the potential application of such methodology for the large-scale, cost-effective production of various sodium-layered transition metal oxide positive electrode materials for SIBs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NMR, MRI, and spectroscopic MRI in inhomogeneous fields

A method for locally creating effectively homogeneous or "clean" magnetic field gradients (of high uniformity) for imaging (with NMR, MRI, or spectroscopic MRI) both in in-situ and ex-situ systems with high degrees of inhomogeneous field strength. THe method of imaging comprises: a) providing a functional approximation of an inhomogeneous static magnetic field strength B.sub.0({right arrow over (r)}) at a spatial position {right arrow over (r)}; b) providing a temporal functional approximation of {right arrow over (G)}.sub.shim(t) with i basis functions and j variables for each basis function, resulting in v.sub.ij variables; c) providing a measured value .OMEGA., which is an temporally accumulated dephasing due to the inhomogeneities of B.sub.0({right arrow over(r)}); and d) minimizing a difference in the local dephasing angle .phi.({right arrow over (r)},t)=.gamma..intg..sub.0.sup.t{square root over (|{right arrow over (B)}.sub.1({right arrow over (r)},t')|.sup.2+({right arrow over (r)}{right arrow over (G)}.sub.shimG.sub.shim(t')+.parallel.{right arrow over (B)}.sub.0({right arrow over (r)}).parallel..DELTA..omega.({right arrow over (r)},t'/.gamma/).sup.2)}dt'-.OMEGA. by varying the v.sub.ij variables to form a set of minimized v.sub.ij variables. The method requires calibration of the static fields prior to minimization, but may thereafter be implemented without such calibration, may be used in open or closed systems, and potentially portable systems.

47 OTHER INSTRUMENTATION↗

Sr{sub 1.98}Eu{sub 0.02}SiO{sub 4} luminescence whisker based on vapor-phase deposition: Facile synthesis, uniform morphology and enhanced luminescence properties

Highlights: • For the first time, it is possible to obtain Sr{sub 1.98}Eu{sub 0.02}SiO{sub 4} whisker. • The whiskers are smooth and uniform with L/D ratio over 50. • Durability and thermal stability of the whisker are enhanced. - Abstract: A high performance strontium silicate phosphor has been successfully synthesized though a facile vapor-phase deposition method. The product consists of single crystal whiskers which are smooth and uniform, and with a sectional equivalent diameter of around 5 μm; the aspect ratio is over 50 and no agglomeration can be observed. X-ray diffraction result confirmed that the crystal structure of the whisker was α’-Sr{sub 2}SiO{sub 4}. The exact chemical composition was Sr{sub 1.98}Eu{sub 0.02}SiO{sub 4} which was analyzed by energy dispersive spectrometer and inductively coupled plasma-mass spectrometer. The whisker shows broad green emission with peak at 523 nm ranging from 470 to 600 nm (excited at 370 nm). Compared with traditional Sr{sub 2}SiO{sub 4}:Eu phosphor, durability (at 85% humidity and 85 °C) and thermal stability of the whisker are obviously improved. Moreover, growth mechanism of the Sr{sub 1.98}Eu{sub 0.02}SiO{sub 4} whiskers is Vapor–Liquid–Solid. On a macro-scale, the product is still powder which makes it suitable for the current packaging process of WLEDs.

36 MATERIALS SCIENCE↗