Search NASA⌕ Search

SEARCH · Search NASA

Results for “value analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Stability analysis of a one-dimensional multiphysics model of a molten salt fast reactor

Reactor designs with a fast neutron spectrum have recently moved into the research focus for possible Generation IV reactor concepts - a representative of which is the molten salt fast reactor (MSFR). In order to assess the safety and reliability of this reactor concept, it is necessary to obtain knowledge of the system behaviour. An important part of this research concerns the dynamical stability of the MSFR. Research regarding the MSFR stability so far has either been using linearized models for stability criteria or only been examining certain transients at fixed parameter values. This work delivers a comprehensive stability analysis for a non-linearized MSFR model, and a wide range of values for all relevant parameters. For this purpose, a one-dimensional MSFR model was set up, taking neutron kinetics and thermal hydraulics in the form of a system of differential equations into account. The stability of this model was investigated by means of the numerical tool MATCONT, which was used to monitor the evolution of a so-called fixed-point solution, here referring to the steady state at operating conditions of the system, while system parameters got varied. The MATCONT analyses showed no loss of stability for any of the considered parameter variations and no solutions that might co-exist in parallel with the steady-state fixed-point solution. Therefore these results indicate a stable fixed point to which all solution transients converge, making the considered MSFR model insusceptible to deviations from the equilibrium. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine learning for surrogate process models of bioproduction pathways

Technoeconomic analysis and life-cycle assessment are critical to guiding and prioritizing bench-scale experiments and to evaluating economic and environmental performance of biofuel or biochemical production processes at scale. Traditionally, commercial process simulation tools have been used to develop detailed models for these purposes. However, developing and running such models can be costly and computationally intensive, which limits the degree to which they can be shared and reproduced in the broader research community. This study evaluates the potential of an automated machine learning approach to develop surrogate models based on conventional process simulation models. The analysis focuses on several high-value biofuels and bioproducts for which pathways of production from biomass feedstocks have been well-established. The results demonstrate that surrogate models can be an accurate and effective tool for approximating the cost, mass and energy balance outputs of more complex process simulations at a fraction of the computational expense.

09 BIOMASS FUELS↗

Early Detection of Therapeutic Response to Hepatic Arterial Infusion Chemotherapy of Liver Metastases from Colorectal Cancer Using Diffusion-Weighted MR Imaging

The purpose of this study was to investigate whether diffusion-weighted magnetic resonance imaging (DWI) is useful for early detection of the response of hepatic colorectal metastases to hepatic arterial infusion chemotherapy (HAIC) with 5-fluorouracil (5-FU). The subjects were 12 patients with hepatic colorectal metastases. The indwelling catheter for HAIC was placed in the hepatic artery, and 1000 mg/m{sup 2} 5-FU was given repeatedly once a week. DWI was performed before and 9 days after HAIC. The minimum and mean apparent diffusion coefficient (ADC) values (minADC and meanADC) were measured. The relative change in ADC values (%ADC) and the relative change in tumor size on follow-up CT after 3 months (reduction ratio) were determined. Liver metastases were divided into two groups, responder and nonresponder. The correlation between %ADC and reduction ratio was determined, and %ADC was compared between the two groups. Eleven patients successfully completed HAIC over the 3-month period; 48 metastatic lesions were evaluated. Positive correlations were observed for relative change between %minADC and reduction ratio (r = 0.709) and between %meanADC and reduction ratio (r = 0.536). Both %minADC and %meanADC were significantly greater in the responder group than in the nonresponder group. With the threshold determined as < 3.5%, the receiver-operating curve analysis showed higher sensitivity and specificity values for %minADC (100% and 92.6%, respectively) than for %meanADC (66.7% and 74.1%, respectively). In conclusion, the relative change in minimum ADC values on DWI may be useful for early detection of the response of liver metastases to HAIC with 5-FU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Testing of a Low Voltage Silicone Nuclear Power Plant Cable

This report summarizes the results generated in FY13 for cable insulation in support of DOE's Light Water Reactor Sustainability (LWRS) Program, in collaboration with the US-Argentine Binational Energy Working Group (BEWG). A silicone (SiR) cable, which was stored in benign conditions for ~30 years, was obtained from Comision Nacional de Energia Atomica (CNEA) in Argentina. Physical property testing was performed on the as-received cable. This cable was artificially aged to assess behavior with additional analysis. SNL observed appreciable tensile elongation values for all cable insulations received, indicative of good mechanical performance. Of particular note, the work presented here provides correlations between measured tensile elongation and other physical properties that may be potentially leveraged as a form of condition monitoring (CM) for actual service cables. It is recognized at this point that the polymer aging community is still lacking the number and types of field returned materials that are desired, but SNL—along with the help of others—is continuing to work towards that goal. This work is an initial study that should be complimented with location-mapping of environmental conditions of CNEA plant conditions (dose and temperature) as well as retrieval, analysis, and comparison with in-service cables.

White II, Gregory Von↗

Two body relativistic wave equations

The relativistic quantum mechanics of two interacting particles is considered. We first present a covariant formulation of kinematics and of reduced phase space, giving a short outline of the classical results. We then quantize the systems for the scalar–scalar, fermion–scalar and fermion–fermion cases. We study the spectrum and the spherical waves solutions of the free case. The interaction with central scalar and vector potentials is introduced and the explicit equations are deduced. The one particle and the non relativistic limits are recovered and the general lines for the solution of the boundary value problems are given. We make a numerical analysis of the first two cases with Coulomb interaction. For the two fermions we largely revisit the model we had previously derived in order to uniformize the description for all the three cases. In order to give a complete review we report in the Appendix some of the most interesting results obtained for atomic and mesonic systems with Coulomb and Cornell potential interactions respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation Testing of a Low Voltage Silicone Nuclear Power Plant Cable.

This report summarizes the results generated in FY13 for cable insulation in support of the Department of Energy's Light Water Reactor Sustainability (LWRS) Program, in collaboration with the US-Argentine Binational Energy Working Group (BEWG). A silicone (SiR) cable, which was stored in benign conditions for %7E30 years, was obtained from Comision Nacional de Energia Atomica (CNEA) in Argentina with the approval of NA-SA (Nucleoelectrica Argentina Sociedad Anonima). Physical property testing was performed on the as-received cable. This cable was artificially aged to assess behavior with additional analysis. SNL observed appreciable tensile elongation values for all cable insulations received, indicative of good mechanical performance. Of particular note, the work presented here provides correlations between measured tensile elongation and other physical properties that may be potentially leveraged as a form of condition monitoring (CM) for actual service cables. It is recognized at this point that the polymer aging community is still lacking the number and types of field returned materials that are desired, but Sandia National Laboratories (SNL) -- along with the help of others -- is continuing to work towards that goal. This work is an initial study that should be complimented with location-mapping of environmental conditions of Argentinean plant conditions (dose and temperature) as well as retrieval, analysis, and comparison with in- service cables.

White, II, Gregory Von↗

Temporal subtraction in chest radiography: Mutual information as a measure of image quality

Purpose: Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or ''lung mask,'' of a previous radiographic image to align with the current image. The gray levels of every pixel in the current image are subtracted from the gray levels of the corresponding pixels in the warped previous image to form a temporal subtraction image. While temporal subtraction images effectively enhance areas of pathologic change, misregistration of the images can mislead radiologists by obscuring the interval change or by creating artifacts that mimic change. The purpose of this study was to investigate the utility of mutual information computed between two registered radiographic chest images as a metric for distinguishing between clinically acceptable and clinically unacceptable temporal subtraction images.Methods: A radiologist subjectively rated the image quality of 138 temporal subtraction images using a 1 (poor) to 5 (excellent) scale. To objectively assess the registration accuracy depicted in the temporal subtraction images, which is the main factor that affects the quality of these images, mutual information was computed on the two constituent registered images prior to their subtraction to generate a temporal subtraction image. Mutual information measures the joint entropy of the current image and the warped previous image, yielding a higher value when the gray levels of spatially matched pixels in each image are consistent. Mutual information values were correlated with the radiologist's subjective ratings. To improve this correlation, mutual information was computed from a spatially limited lung mask, which was cropped from the bottom by 10%-60%. Additionally, the number of gray-level values used in the joint entropy histogram was varied. The ability of mutual information to predict the clinical acceptability of a temporal subtraction image was evaluated through receiver operating characteristic (ROC) analysis. Results: The mean correlation coefficient obtained between mutual information computed on constituent images and the subjective rating of temporal subtraction image quality was 0.785. ROC analysis yielded an average A{sub z} value of 0.852 for the ability of mutual information to distinguish between temporal subtraction images of clinically acceptable and clinically unacceptable quality. Conclusions: The results of this study establish a relationship between mutual information and temporal subtraction registration accuracy and demonstrate the ability of mutual information to objectively indicate the presence of misregistration artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quasi-Static Time Series Fatigue Simulation for PV Inverter Semiconductors with Long-Term Solar Profile

Power system simulations with long-term data tend to have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stresses cycle is with line frequency. This requires the time step of the fatigue simulation to be much smaller than the line period. This small time step results in poor simulation speed, especially for long-term simulations. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The fatigue analysis typically focuses on the peak and valley values of a strain and neglect the transients from peaks to valleys. The proposed simulation utilizes this property of fatigue analysis and calculates the steady state of the semiconductor junction temperature only. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset without losing accuracy.

fast simulation↗

Role of Microbial Exopolymeric Substances (EPS) on Chromium Sorption and Transport in Heterogeneous Subsurface Soils: I. Cr(III) Complexation with EPS in Aqueous Solution

Chromium (III) binding by exopolymeric substances (EPS) isolated from Pseudomonas putida P18, Pseudomonas aeruginosa P16 and Pseudomonas stutzeri P40 strains were investigated by the determination of conditional stability constants and the concentration of functional groups using the ion-exchange experiments and potentiometric titrations. Spectroscopic (EXAFS) analysis was also used to obtain information on the nature of Cr(III) binding with EPS functional groups. The data from ion-exchange experiments and potentiometric titrations were evaluated using a non-electrostatic discrete ligand approach. The modeling results show that the acid/base properties of EPSs can be best characterized by invoking four different types of acid functional groups with arbitrarily assigned pK{sub a} values of 4, 6, 8 and 10. The analysis of ion-exchange data using the discrete ligand approach suggests that while the Cr binding by EPS from P. aeruginosa can be successfully described based on a reaction stoichiometry of 1:2 between Cr(III) and HL{sub 2} monoprotic ligands, the accurate description of Cr binding by EPSs extracted from P. putida and P. stutzeri requires postulation of 1:1 Cr(III)-ligand complexes with HL{sub 2} and HL{sub 3} monoprotic ligands, respectively. These results indicate that the carboxyl and/or phosphoric acid sites contribute to Cr(III) binding by microbial EPS, as also confirmed by EXAFS analysis performed in the current study. Overall, this study highlights the need for incorporation of Cr-EPS interactions into transport and speciation models to more accurately assess microbial Cr(VI) reduction and chromium transport in subsurface systems, including microbial reactive treatment barriers.

54 ENVIRONMENTAL SCIENCES↗

SU-F-T-03: Radiobiological Evaluation of a Directional Brachytherapy Device Surgically Implanted Following EBRT

Purpose: Preceding surgical implantation following external-beam radiotherapy (EBRT) delivery, a radiobiological evaluation was performed for a new LDR Pd-103 directional brachytherapy device (CivaSheet). As this was the first case with the device used in combination with EBRT, there was concern to determine the appropriate prescription dose. Methods: The radiobiological model of Dale (1985, 1989) was used for a permanent LDR implant including radioactive decay. The biological effective dose (BED) was converted to the equivalent dose in 2 Gy fractions (EQD2) for comparison with EBRT prescription expectations. Given IMRT delivery of 50.4 Gy, an LDR brachytherapy dose of approximately 15–20 Gy EQD2 was desired. To be specific to the treatment site (leiomyosarcoma T2bN0M0, grade 2 with R1 surgical margin), the radiobiological model required several radiobiological parameters with values taken from the literature. A sensitivity analysis was performed to determine their relative importance on the calculated BED and subsequent EQD2. The Pd-103 decay constant (λ=0.0017 h{sup −1}) was also used. DVHs were prepared for pre- and post-surgical geometries to glean the possible and realized implant geometric configuration. DVHs prepared in VariSeed9 were converted to BEDVHs and subsequently EQD2 values for each volume-element. Results: For a physical dose of 28 Gy to a 0.5 cm depth, BED=21.7 Gy and EQD2=17.6 Gy, which was near the center of the desired EQD2 range. Tumor bed (CTV=4 cm{sup 3}) coverage was 99.2% with 48 sources implanted. In order of decreasing importance from the sensitivity analysis, the radiobiological parameters were α=0.25 Gy{sup −1}, T{sub POT}=23 days, α/β=8.6 Gy, and T=1.5 h. Percentage variations in these values produced EQD2 variations of 40%, 20%, 18%, and 1%, respectively. Conclusion: This radiobiological evaluation indicated that prescription dose may be determined for comparison with the desired EQD2, and that radiobiologicalparameter uncertainties produce smaller EQD2 differences than had physical dose been simply added to EBRT dose. Research support provided in part by CivaTech Oncology, Inc. for Dr. Rivard.

60 APPLIED LIFE SCIENCES↗

Engineering Seismic Base Layer for Defining Design Earthquake Motion

Engineer's common sense that incident wave is common in a widespread area at the engineering seismic base layer is shown not to be correct. An exhibiting example is first shown, which indicates that earthquake motion at the ground surface evaluated by the analysis considering the ground from a seismic bedrock to a ground surface simultaneously (continuous analysis) is different from the one by the analysis in which the ground is separated at the engineering seismic base layer and analyzed separately (separate analysis). The reason is investigated by several approaches. Investigation based on eigen value problem indicates that the first predominant period in the continuous analysis cannot be found in the separate analysis, and predominant period at higher order does not match in the upper and lower ground in the separate analysis. The earthquake response analysis indicates that reflected wave at the engineering seismic base layer is not zero, which indicates that conventional engineering seismic base layer does not work as expected by the term 'base'. All these results indicate that wave that goes down to the deep depths after reflecting in the surface layer and again reflects at the seismic bedrock cannot be neglected in evaluating the response at the ground surface. In other words, interaction between the surface layer and/or layers between seismic bedrock and engineering seismic base layer cannot be neglected in evaluating the earthquake motion at the ground surface.

58 GEOSCIENCES↗

Information content of spatially distributed ground-based measurements for hydrologic-parameter calibration in mixed rain-snow mountain headwaters

Parameters in hydrologic models used in mixed rain-snow regions are often uncertain to calibrate and overfitted on streamflow. To contribute addressing these challenges, we used an algorithm that assesses modeling performances through time (Dynamic Identifiability Analysis) to quantify the information content of spatially distributed ground-based measurements for identifying optimal parameter values in the Precipitation Runoff Modeling System (PRMS) model. Including spatially distributed ground-based measurements in Identifiability Analysis allowed us to unambiguously estimate more parameter values than only using streamflow (seven parameters instead of two out of a pool of thirty-three). Peaks in information gain were obtained when using dew-point temperature to identify precipitation phase-partitioning parameters. Multi-attribute identifiability analysis also yielded optimal parameter values that were temporally less variable than those estimated using streamflow alone. Overall, identifying parameter values using ground-based measurements improved the simulation of key drivers of the surface-water budget, such as air temperature and precipitation-phase partitioning. However, parameters simulating surface-to-subsurface mass fluxes like snow accumulation and melt or evapotranspiration were poorly identified by any attribute and so emerged as key sources of predictive uncertainty for this distributed-parameter hydrologic model. In conclusion, this work demonstrates the value of expanded ground-based measurements for identifying parameters in distributed-parameter hydrologic models and so diagnosing their conceptual uncertainty across the water budget.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-77: Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans

Purpose: Patient-specific QA procedures for IMRT and VMAT are traditionally performed by comparing TPS calculations with measured single point values and plane dose distributions by means of gamma analysis. New QA devices permit us to calculate 3D dose distributions on patient anatomy as redundant secondary check and reconstruct it from measurements taken with 2D and 3D detector arrays. 3D dose calculations allow us to perform DVH-based comparisons with clinical relevance, as well as 3D gamma analysis. One of these systems (Compass, IBA Dosimetry) combines traditional 2D with new anatomical-based 3D gamma analysis. This work shows the ability of this system by comparing 2D and 3D gamma analysis in pre-treatment QA for several VMAT prostate plans. Methods: Compass is capable of calculating dose as secondary check from DICOM TPS data and reconstructing it from measurements taken by a 2D ion chamber array (MatriXX Evolution, IBA Dosimetry). Both 2D and 3D gamma tests are available to compare calculated and reconstructed dose in Compass with TPS RT Dose. Results: 15 VMAT prostate plans have been measured with Compass. Dose is reconstructed with Compass for these plans. 2D gamma comparisons can be done for any plane from dose matrix. Mean gamma passing rates for isocenter planes (axial, coronal, sagittal) are (99.7±0.2)%, (99.9±0.1)%, (99.9±0.1)% for reconstructed dose planes. 3D mean gamma passing rates are (98.5±1.7)% for PTVs, (99.1±1.5)% for rectum, (100.0±0.0)% for bladder, (99.6±0.7)% for femoral heads and (98.1±4.1)% for penile bulb. Conclusion: Compass is a powerful tool to perform a complete pre-treatment QA analysis, from 2D techniques to 3D DVH-based techniques with clinical relevance. All reported values for VMAT prostate plans are in good agreement with TPS values. This system permits us to ensure the accuracy in the delivery of VMAT treatments completing a full patient-specific QA program.

60 APPLIED LIFE SCIENCES↗

Revisiting Néel 60 years on: The magnetic anisotropy of L1 0 FeNi (tetrataenite)

The magnetocrystalline anisotropy energy of atomically ordered L1 0 FeNi (the meteoritic mineral tetrataenite) is studied within a first-principles electronic structure framework. Two compositions are examined: equiatomic Fe 0.5 Ni 0.5 and an Fe-rich composition, Fe 0.56 Ni 0.44 . It is confirmed that, for the single crystals modeled in this work, the leading-order anisotropy coefficient K 1 dominates the higher-order coefficients K 2 and K 3 . To enable comparison with experiment, the effects of both imperfect atomic long-range order and finite temperature are included. While our computational results initially appear to undershoot the measured experimental values for this system, careful scrutiny of the original analysis due to Néel et al. [J. Appl. Phys. 35, 873 (1964)] suggests that our computed value of K 1 is, in fact, consistent with experimental values, and that the noted discrepancy has its origins in the nanoscale polycrystalline, multivariant nature of experimental samples, that yields much larger values of K 2 and K 3 than expected a priori. These results provide fresh insight into the existing discrepancies in the literature regarding the value of tetrataenite’s uniaxial magnetocrystalline anisotropy in both natural and synthetic samples.

36 MATERIALS SCIENCE↗

Fuel Cell Backup Power System for Grid-Service and Micro-Grid in Telecommunication Applications

This paper presents the feasibility and economics of using fuel cell backup power systems in telecommunication cell towers to provide grid services (e.g., ancillary services, demand response). The fuel cells are able to provide power for the cell tower during emergency conditions. This study evaluates the strategic integration of clean, efficient, and reliable fuel cell systems with the grid for improved economic benefits. The backup systems have potential as enhanced capability through information exchanges with the power grid to add value as grid services that depend on location and time. The economic analysis has been focused on the potential revenue for distributed telecommunications fuel cell backup units to provide value-added power supply. This paper shows case studies on current fuel cell backup power locations and regional grid service programs. The grid service benefits and system configurations for different operation modes provide opportunities for expanding backup fuel cell applications responsive to grid needs. The objective of this work primarily focuses on how fuel cells can become a significant part of the telecom backup power to reduce system costs, environmental impact, and dependence on fossil fuels, while ensuring continuity of indispensable service for mobile users. The study identifies the approaches on the fuel cell application through nano/microgrids for an extensive network of fuel cells as distributed energy resources. The possibilities of various application scenarios extend the fuel cell technologies and microgrid for reliable power supply.

30 DIRECT ENERGY CONVERSION↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Which Combinations of Environmental Conditions and Microphysical Parameter Values Produce a Given Orographic Precipitation Distribution?

This study applies an idealized modeling framework, alongside a Bayesian Markov chain Monte Carlo (MCMC) algorithm, to explore which combinations of upstream environmental conditions and cloud microphysical parameter values can produce a particular precipitation distribution over an idealized two-dimensional, bell-shaped mountain. Simulations focus on orographic precipitation produced when an atmospheric river interacts with topography. MCMC-based analysis reveals that different combinations of parameter values produce a similar precipitation distribution, with the most influential parameters being relative humidity (RH), horizontal wind speed (U), surface potential temperature (θ sfc ), and the snow fall speed coefficient (A s ). RH, U, and A s exhibit interdependence: changes in one or more of these factors can be mitigated by compensating changes in the other(s) to produce similar orographic precipitation rates. The results also indicate that the parameter sensitivities and relationships can vary for spatial subregions and given different environmental conditions. In particular, high θ sfc values are more likely to produce the target precipitation rate and spatial distribution, and thus the ensemble of simulations shows a preference for liquid precipitation at the surface. The results presented here highlight the complexity of orographic precipitation controls, and have implications for flood and water management, observational efforts, and climate change.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Factors Associated with Secondary Functional Patency After Percutaneous Transluminal Angioplasty of the Early Failing or Immature Hemodialysis Arteriovenous Fistula

Purpose: To evaluate the efficacy of percutaneous transluminal angioplasty for early failing hemodialysis arteriovenous fistulas (AVFs) and predictors of secondary functional patency (FP). Methods: A review of our endovascular registry database showed that 61 patients with early failure after a surgically created AVF underwent endovascular intervention between 2011 and 2016. Median time from AVF creation to first intervention was 5.6 weeks. Median duration of follow-up was 14 months. Items related to the technical success rate and primary and secondary FP, and factors associated with secondary FP were analyzed. Results: Technical success was achieved in 55 (90%) of 61 patients. The primary and secondary FP rates were 42% and 65% at 12 months, respectively. Multivariate analysis showed that lesion length (HR; 1.15, P = 0.001) and lesions including juxta-AVF (the portion of fistula vein within 2 cm of the arteriovenous anastomosis, HR; 6.23, P = 0.008) were factors associated with reduced secondary FP. ROC curve analysis indicated lesion length with cutoff value ≥ 9 cm as a risk factor for reduced secondary FP. Secondary FP at 12 months for patients with no risk factors, with 1, and with 2 was 86%, 65%, and 0%, respectively. There was a significant difference in secondary FP rates among these groups (P = 0.001). Conclusions: A lesion length and juxta-AVF lesion are the risk factors for reduced secondary FP. The secondary FP rate at 12 months is acceptable in patients without risk factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗