Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Time Dependence of Collision Probabilities During Satellite Conjunctions

The NASA Conjunction Assessment Risk Analysis (CARA) team has recently implemented updated software to calculate the probability of collision (P (sub c)) for Earth-orbiting satellites. The algorithm can employ complex dynamical models for orbital motion, and account for the effects of non-linear trajectories as well as both position and velocity uncertainties. This “3D P (sub c)” method entails computing a 3-dimensional numerical integral for each estimated probability. Our analysis indicates that the 3D method provides several new insights over the traditional “2D P (sub c)” method, even when approximating the orbital motion using the relatively simple Keplerian two-body dynamical model. First, the formulation provides the means to estimate variations in the time derivative of the collision probability, or the probability rate, R (sub c). For close-proximity satellites, such as those orbiting in formations or clusters, R (sub c) variations can show multiple peaks that repeat or blend with one another, providing insight into the ongoing temporal distribution of risk. For single, isolated conjunctions, R (sub c) analysis provides the means to identify and bound the times of peak collision risk. Additionally, analysis of multiple actual archived conjunctions demonstrates that the commonly used “2D P (sub c)” approximation can occasionally provide inaccurate estimates. These include cases in which the 2D method yields negligibly small probabilities (e.g., P (sub c)) is greater than 10 (sup -10)), but the 3D estimates are sufficiently large to prompt increased monitoring or collision mitigation (e.g., P (sub c) is greater than or equal to 10 (sup -5)). Finally, the archive analysis indicates that a relatively efficient calculation can be used to identify which conjunctions will have negligibly small probabilities. This small-P (sub c) screening test can significantly speed the overall risk analysis computation for large numbers of conjunctions.

Hall, Doyle T.↗

A Significant Increase in Detection of High-resolution Emission Spectra Using a Three-dimensional Atmospheric Model of a Hot Jupiter

High-resolution spectroscopy has opened the way for new, detailed study of exoplanet atmospheres. There is evidence that this technique can be sensitive to the complex, three-dimensional (3D) atmospheric structure of these planets. In this work, we perform cross-correlation analysis of high-resolution (R ∼ 100,000) CRIRES/VLT emission spectra of the hot Jupiter HD 209458b. We generate template emission spectra from a 3D atmospheric circulation model of the planet, accounting for temperature structure and atmospheric motions—winds and planetary rotation—missed by spectra calculated from one-dimensional models. In this first-of-its-kind analysis, we find that using template spectra generated from a 3D model produces a more significant detection (6.9σ) of the planet’s signal than any of the hundreds of one-dimensional models we tested (maximum of 5.1σ). We recover the planet’s thermal emission, its orbital motion, and the presence of CO in its atmosphere at high significance. Additionally, we analyzed the relative influences of 3D temperature and chemical structures in this improved detection, including the contributions from CO and H{sub 2}O, as well as the role of atmospheric Doppler signatures from winds and rotation. This work shows that the hot Jupiter’s 3D atmospheric structure has a first-order influence on its emission spectra at high resolution and motivates the use of multidimensional atmospheric models in high-resolution spectral analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D MODEL ATMOSPHERES FOR EXTREMELY LOW-MASS WHITE DWARFS

We present an extended grid of mean three-dimensional (3D) spectra for low-mass, pure-hydrogen atmosphere DA white dwarfs (WDs). We use CO5BOLD radiation-hydrodynamics 3D simulations covering T{sub eff} = 6000–11,500 K and log g = 5–6.5 (g in cm s{sup −2}) to derive analytical functions to convert spectroscopically determined 1D temperatures and surface gravities to 3D atmospheric parameters. Along with the previously published 3D models, the 1D to 3D corrections are now available for essentially all known convective DA WDs (i.e., log g = 5–9). For low-mass WDs, the correction in temperature is relatively small (a few percent at the most), but the surface gravities measured from the 3D models are lower by as much as 0.35 dex. We revisit the spectroscopic analysis of the extremely low-mass (ELM) WDs, and demonstrate that the 3D models largely resolve the discrepancies seen in the radius and mass measurements for relatively cool ELM WDs in eclipsing double WD and WD + millisecond pulsar binary systems. We also use the 3D corrections to revise the boundaries of the ZZ Ceti instability strip, including the recently found ELM pulsators.

79 ASTRONOMY AND ASTROPHYSICS↗

Preconditioned domain decomposition scheme for three-dimensional aerodynamic sensitivity analysis

A preconditioned domain decomposition scheme is introduced for the solution of the 3D aerodynamic sensitivity equation. This scheme uses the iterative GMRES procedure to solve the effective sensitivity equation of the boundary-interface cells in the sensitivity analysis domain-decomposition scheme. Excluding the dense matrices and the effect of cross terms between boundary-interfaces is found to produce an efficient preconditioning matrix.

Eleshaky, Mohammed E.↗

Spatially Resolved MicroDiffraction Analysis of the Plastic Deformation in the Shock Recovered Al Single Crystal

A spatially resolved diffraction method with a sub micrometer-diameter beam and 3D differential aperture technique together with MD simulations, SEM and OIM analysis are applied to understand the arrangements of voids, geometrically necessary dislocations and strain gradient distribution in samples of Al (123) single crystal shocked to incipient spallation fracture. We describe how geometrically necessary dislocations and effective strain gradient alter white beam Laue patterns of the shocked materials. We show how to quantitatively determine the orientation and density of geometrically necessary dislocations in the shock recovered Al samples being initially oriented for single slip.

36 MATERIALS SCIENCE↗

Measurement of thermal gap conductance using the laser flash method

Thermal gap conductance refers to overall heat conductance through a gas-filled gap as interface thermal resistance between the gas and surface has to be considered. The analysis of new ATR (Advanced Test Reactor) fuel experiments requires experimental data and models for the gap conductance of the cladding/fuel capsule gap, which typically varies from 5 μm to 50 μm and is filled with He at 1-3 atm. Although past research has studied the gap conductance between UO{sub 2} fuel and Zircaloy cladding, new experiments are needed to provide the gap conductance data between HT9 and stainless steel 316, and between advanced fuels and advanced cladding in the Accident Tolerant Fuels program. In this paper, the laser flash method is modified to measure the gap conductance. The gap is formed by welding two stainless steel 316 disks with three spacers. The temperature at the rear surface, after exposure to the laser pulse at the front surface, is modeled with 1D heat transfer through three layers. The analytic solution is then fitted with the measured temperature to determine gap conductance. The sensitivity analysis based on the 1D assumption and 3D numerical simulations were performed to assess the sensitivity and uncertainty of the measurement. It is concluded the heat capacity of the gas in the gap has minimal impact on the measurement, which indicates that the thermal property determined by this method is the thermal conductance, instead of the thermal diffusivity. Convective heat loss through sidewalls under the current experimental design has insignificant influences. Heat transfer through spacers may cause up to 10% overestimation of thermal gap conductance, but the effects can be mostly eliminated by the design of grooves on samples. The result established a pathway for gap conductance determination. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preparing for the Next Generation of EUV Lithography at the Center for X-ray Optics

The introduction of EUV lithography into high-volume semiconductor manufacturing this year represents a monumental milestone for EUV technology. After nearly 30 years of development, the EUV research community has overcome many of the key obstacles required to enable the long-awaited integration of EUV lithography into the lab. These obstacles have included: the development of a stable, high-powered EUV source to ensure adequate exposure tool reliability; controlling EUV mask defects and mask contamination; and the development of EUV resists with adequate sensitivity, resolution, and line width roughness to meet the tolerances required for high-volume manufacturing. As EUV moves into its second generation, there will be new challenges facing the community as it works to push EUV technology into the future. Smaller feature sizes will be achieved using higher numerical aperture optics, which are planned to have an anamorphic geometry (asymmetric magnification and numerical aperture between horizontal and vertical axes) to overcome 3D effects at the mask. This new geometry and its larger angle ranges make understanding mask absorber and multilayer effects all the more important. New methods for high-NA wavefront metrology need to be tested to ensure that these optical systems can be aligned to operate with minimal aberrations. Mask defects need to continue to be studied, and the inclusion of EUV pellicles in the roadmap requires that mask inspection and review systems adapt accordingly. Finally, new resists must be developed to support the increased resolution of feature sizes below 8 nm half pitch. The Center for X-ray Optics (CXRO) at Berkeley Lab has been a leader in EUV research for the past 25 years. Leveraging 13.5 nm EUV light from the Advanced Light Source synchrotron facility, CXRO is home to several EUV and soft X-ray (SXR) research tools that have provided important insights into EUV resists, masks, and coatings. The 0.3 NA Microfield exposure tool (MET) and Dose Calibration Tool (DCT) have played an instrumental role in the development of the current generation of high-resolution EUV resists. The Actinic Inspection Tool (AIT) and its successor, SHARP, have enabled aerial image analysis, providing key insights into mask defects, 3D mask effects, illumination, and aberrations. And the CXRO Reflectometer continues to be the industry standard in multilayer coating and EUV mask scattering metrology. To address the new challenges facing the next generation of EUV lithography, CXRO has upgraded its suite of EUV research tools. The 0.5 NA MET5 is a newly commissioned projection lithography tool that is capable of printing feature sizes down to 8 nm half pitch. A new radiation chemistry program is deploying several techniques aimed at dissecting the role of primary photoelectrons and secondary electrons in EUV resists. The SHARP microscope has been outfitted with anamorphic zone plate lenses that can emulate the geometry of next-generation EUV scanners, and the reflectometer has been applied to new scattering experiments for the purpose of understanding the 3D effects of EUV mask multilayers, as well as determining mask properties using scattering profiles. In parallel with these tools, the CXRO High-NA Wavefront Sensing Program is developing high-resolution wavefront sensors suitable for measuring aberrations at high NA. This article presents an overview of these programs and describes how they will address the primary challenges that face the EUV community as it moves to the next generation of EUV lithography.

47 OTHER INSTRUMENTATION↗

Syntheses, structures, luminescence, and magnetism of four 3D lanthanide 5-sulfosalicylates

Four 3D lanthanide(III) complexes with 5-sulfosalicylic acid (H{sub 3}SSA) as bridging ligands, Ln(SSA)(H{sub 2}O){sub 2} [Ln=Ce(III) (1), Pr(III) (2), Nd(III) (3) and Dy(III) (4)], have been synthesized and characterized by elemental analysis, IR, XRD and single-crystal X-ray diffraction. X-ray structural analysis reveals that isostructral complexes 1-4 possess 3D structures with 4{sup 6}6{sup 4} topology. Complexes 1 and 2 exhibit broad intraligand fluorescent emission bands. Complexes 3 and 4 not only display intraligand fluorescent emission bands, but also present Nd(III) characteristic emission in the near-IR region and sensitized luminescence of Dy(III) ions in the visible region, respectively. Variable-temperature magnetic susceptibility measurements of 2-4 have been studied over the temperature range of 4-300 K. - Graphical abstract: Syntheses and crystal structures of four 3D lanthanide-5-sulfosalicylates, Ln(SSA)(H{sub 2}O){sub 2} [Ln=Ce(III) (1), Pr(III) (2), Nd(III) (3), and Dy(III) (4)], have been reported. In complexes 1-4, Ln(III) acting as 5-connected inorganic node and SSA{sup 3-} ligand acing as 5-connected organic node interlink into rarely reported 4{sup 6}6{sup 4} topology network. Luminescence and magnetism properties have also been studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of using two- versus three-dimensional computational modeling of fluidized beds: Part II, budget analysis

The partial differential equations for modeling gas-solid flows using computational fluid dynamics are compared for different coordinate systems. The numerical results of 2D and 3D simulations for both cylindrical and rectangular domains are presented in Part I (N. Xie, F. Battaglia, S. Pannala, Effects of using two- versus three-dimensional computational modeling of fluidized beds: Part I, Hydrodynamics (2007-this volume), doi:10.1016/j.powtec.2007.07.005), comparing the hydrodynamic features of a fluidized bed. The individual terms of the governing equations in 2D and 3D simulations with the cylindrical and Cartesian coordinate systems are evaluated in this study through a budget analysis. The additional terms appearing in the 3D equations can be used to explain the discrepancies between 2D and 3D simulations. The values of the additional terms is shown to increase as inlet gas velocity increases. This explains the good agreement between 2D and 3D simulations that is observed for bubbling regimes with low gas velocity, and why the differences between 2D and 3D simulations increases for slugging and turbulent regimes.

01 COAL, LIGNITE, AND PEAT↗

First use of three-dimensional equilibrium, stability, and transport calculations for interpretation of ELM-triggering with magnetic perturbations in NSTX

The application of non-axisymmetric magnetic perturbations has been demonstrated to destabilize edge-localized modes (ELMs) in the National Spherical Torus Experiment. A model 3D equilibrium has been calculated for these experiments using the VMEC code, which assumes nested flux surfaces and therefore that resonant perturbations are shielded. First, a free-boundary equilibrium is calculated using the NSTX coil set, with pressure and current profiles matched to a standard 2D reconstruction, but with up-down symmetry enforced. A new equilibrium is then calculated with the n = 3 field applied at a level consistent with experiment. This equilibrium is then used as the basis of further calculations using codes developed for analysis of stellarator plasmas. The neoclassical transport due to the 3D fields is calculated to be small compared with the experimental transport rates. Initial stability analysis has been performed, and indicates a modest degradation in ballooning stability with 3D fields applied. A new 3D equilibrium is also calculated using the SIESTA code, which allows for the formation of islands and stochastic regions. A comparison of the field structure between the SIESTA calculation and the assumption of fully penetrated vacuum perturbation indicates smaller island sizes and very small stochastic transport in the SIESTA case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D structural fluctuation of IgG1 antibody revealed by individual particle electron tomography

Commonly used methods for determining protein structure, including X-ray crystallography and single-particle reconstruction, often provide a single and unique three-dimensional (3D) structure. However, in these methods, the protein dynamics and flexibility/fluctuation remain mostly unknown. Here, we utilized advances in electron tomography (ET) to study the antibody flexibility and fluctuation through structural determination of individual antibody particles rather than averaging multiple antibody particles together. Through individual-particle electron tomography (IPET) 3D reconstruction from negatively-stained ET images, we obtained 120 ab-initio 3D density maps at an intermediate resolution (~1–3 nm) from 120 individual IgG1 antibody particles. Using these maps as a constraint, we derived 120 conformations of the antibody via structural flexible docking of the crystal structure to these maps by targeted molecular dynamics simulations. Statistical analysis of the various conformations disclosed the antibody 3D conformational flexibility through the distribution of its domain distances and orientations. This blueprint approach, if extended to other flexible proteins, may serve as a useful methodology towards understanding protein dynamics and functions.

59 BASIC BIOLOGICAL SCIENCES↗

A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery

Purpose: Monoscopic x-ray imaging with on-board kV devices is an attractive approach for real-time image guidance in modern radiation therapy such as VMAT or IMRT, but it falls short in providing reliable information along the direction of imaging x-ray. By effectively taking consideration of projection data at prior times and/or angles through a Bayesian formalism, the authors develop an algorithm for real-time and full 3D tumor localization with a single x-ray imager during treatment delivery. Methods: First, a prior probability density function is constructed using the 2D tumor locations on the projection images acquired during patient setup. Whenever an x-ray image is acquired during the treatment delivery, the corresponding 2D tumor location on the imager is used to update the likelihood function. The unresolved third dimension is obtained by maximizing the posterior probability distribution. The algorithm can also be used in a retrospective fashion when all the projection images during the treatment delivery are used for 3D localization purposes. The algorithm does not involve complex optimization of any model parameter and therefore can be used in a ''plug-and-play'' fashion. The authors validated the algorithm using (1) simulated 3D linear and elliptic motion and (2) 3D tumor motion trajectories of a lung and a pancreas patient reproduced by a physical phantom. Continuous kV images were acquired over a full gantry rotation with the Varian TrueBeam on-board imaging system. Three scenarios were considered: fluoroscopic setup, cone beam CT setup, and retrospective analysis. Results: For the simulation study, the RMS 3D localization error is 1.2 and 2.4 mm for the linear and elliptic motions, respectively. For the phantom experiments, the 3D localization error is < 1 mm on average and < 1.5 mm at 95th percentile in the lung and pancreas cases for all three scenarios. The difference in 3D localization error for different scenarios is small and is not statistically significant. Conclusions: The proposed algorithm eliminates the need for any population based model parameters in monoscopic image guided radiotherapy and allows accurate and real-time 3D tumor localization on current standard LINACs with a single x-ray imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Second spectrum of Manganese (Mn II), Part II: Revised fine and hyperfine structure analysis of odd-parity levels

In the first part of this global work, we have achieved the fine and hyperfine structure (fs and hfs) parametric study of even-parity levels, which confirmed in the whole the well-founded basis of previous analyses. Unfortunately, in the present work devoted to odd-parity levels, some divergences appear. For instance, the three levels w{sup 5}P{sub 3}, w{sup 5}P{sub 2}, w{sup 5}P{sub 1} located respectively at 86898, 86937 and 86961 cm{sup −1} should not belong to the 3d{sup 4}({sup 5}D)4s4p configuration, as indicated earlier, but rather to 3d{sup 5}({sup 4}P)5p. In the other hand, the levels whose energies are: 88 840, 89 079 and 89 429 cm{sup −1} should belong this time to 3d{sup 4}({sup 5}D)4s4p instead of 3d{sup 5}5p, as mentioned previously. Our analysis is strengthened when using experimental hfs data as finger prints, even if the comparison between these experimental hfs data, given in the literature, and our calculated results also shows in numerous cases some notable discrepancies, concerning particularly the sign of the electric quadrupole factor. The main monoelectronic hfs parameter values, extracted from our least square fitting procedure, are: a{sub 3d}{sup 01}(3d{sup 5}4p)= 17.58 mK, b{sub 3d}{sup 02}(3d{sup 5}4p)= 10.27 mK, a{sub 3d}{sup 01} (3d{sup 4}4s4p)= 18.74 mK and a{sub 4s}{sup 10}(3d{sup 4}4s4p)= 274.9 mK. These parameter values, displayed for the first time, were analyzed and compared with ab-initio calculations. As in the first part, we conclude this work by giving the predicted hfs A and B constants of low-lying levels of these two configurations, whose splitting are not yet measured.

74 ATOMIC AND MOLECULAR PHYSICS↗

Geometrically nonlinear analysis of layered composite plates and shells

A degenerated three dimensional finite element, based on the incremental total Lagrangian formulation of a three dimensional layered anisotropic medium was developed. Its use in the geometrically nonlinear, static and dynamic, analysis of layered composite plates and shells is demonstrated. A two dimenisonal finite element based on the Sanders shell theory with the von Karman (nonlinear) strains was developed. It is shown that the deflections obtained by the 2D shell element deviate from those obtained by the more accurate 3D element for deep shells. The 3D degenerated element can be used to model general shells that are not necessarily doubly curved. The 3D degenerated element is computationally more demanding than the 2D shell theory element for a given problem. It is found that the 3D element is an efficient element for the analysis of layered composite plates and shells undergoing large displacements and transient motion.

Chao, W. C.↗

Generic hypersonic inlet module analysis

A computational study associated with an internal inlet drag analysis was performed for a generic hypersonic inlet module. The purpose of this study was to determine the feasibility of computing the internal drag force for a generic scramjet engine module using computational methods. The computational study consisted of obtaining two-dimensional (2D) and three-dimensional (3D) computational fluid dynamics (CFD) solutions using the Euler and parabolized Navier-Stokes (PNS) equations. The solution accuracy was assessed by comparisons with experimenal pitot pressure data. The CFD analysis indicates that the 3D PNS solutions show the best agreement with experimental pitot pressure data. The internal inlet drag analysis consisted of obtaining drag force predictions based on experimental data and 3D CFD solutions. A comparative assessment of each of the drag prediction methods is made and the sensitivity of CFD drag values to computational procedures is documented. The analysis indicates that the CFD drag predictions are highly sensitive to the computational procedure used.

Cockrell, Charles E., Jr.↗

Generic Hypersonic Inlet Module Analysis

A computational study associated with an internal inlet drag analysis was performed for a generic hypersonic inlet module. The purpose of this study was to determine the feasibility of computing the internal drag force for a generic scramjet engine module using computational methods. The computational study consisted of obtaining two-dimensional (2D) and three-dimensional (3D) computational fluid dynamics (CFD) solutions using the Euler and parabolized Navier-Stokes (PNS) equations. The solution accuracy was assessed by comparisons with experimental pitot pressure data. The CFD analysis indicates that the 3D PNS solutions show the best agreement with experimental pitot pressure data. The internal inlet drag analysis consisted of obtaining drag force predictions based on experimental data and 3D CFD solutions. A comparative assessment of each of the drag prediction methods is made and the sensitivity of CFD drag values to computational procedures is documented. The analysis indicates that the CFD drag predictions are highly sensitive to the computational procedure used.

Cockrell, Chares E., Jr.↗

Development of an Improved RELAP5-3D Model for the High Temperature Test Facility

High-temperature gas-cooled reactors (HTGRs) are rapidly approaching deployment. Confidence in transient analysis of these systems for design, optimization, and licensing calculations requires modeling and simulation tools that have been validated against data relevant to HTGR conditions. The High Temperature Test Facility (HTTF) is an integral effects thermal hydraulics test facility for prismatic HTGRs. In spring and summer of 2019, HTTF was used for a series of experiments that now serve as the basis for the OECD/NEA Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data (HTGR T/H Benchmark). This benchmark contains problems for systems code, computational fluid dynamics (CFD), and coupled systems code/CFD modeling representing lower plenum mixing and both the depressurized and pressurized conduction cooldown (DCC and PCC respectively) transients. Benchmark problems include exercises for code-to-code and code-to-data comparisons as well as an exercise for error scaling between HTTF and the Modular High Temperature Gas-Cooled Reactor, which serves as the basis for the HTTF design. Previous analysis as part of the HTGR T/H benchmark used a RELAP5-3D model developed at Idaho National Laboratory (INL) and demonstrated an ability to reproduce trends in the measured data but difficulties reproducing experimental values within their uncertainty. These difficulties were largely attributed to assumptions made during the development of the initial RELAP5-3D model, which predated the HTTF experiments. A significant cause of difficulty reproducing the measured temperatures may be the radial nodalization of the previous RELAP5-3D model. The new model provides a finer nodalization to assess the impact of radial nodalization and allows for asymmetric heating within the core, which was a feature of multiple HTTF experiments. In this paper, we present the new RELAP5-3D model of HTTF. In addition to describing the new model, this paper compares the new and old models and provides results for a full-power steady state, a DCC, and a PCC in HTTF. These analyses are based on the code-to-code comparison exercises for the DCC and PCC problems of the HTGR T/H benchmark. We present the results of these exercises from the new model and compare them to the results of the old model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment

Purpose: A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjectsin vivo under weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. Methods: The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. Results: A 2D Euclidean distance-based metric of subjects’ motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D warping improved the SSIM in the central slice by 20.22%, 16.83%, and 25.77% in the data with the largest motion among the five datasets (SCAN5); improvement in off-center slices was 18.94%, 29.14%, and 36.08%, respectively. Conclusions: The authors showed that C-arm CT control can be implemented for nonstandard horizontal trajectories which enabled us to scan and successfully reconstruct both legs of volunteers in weight-bearing positions. As predicted using theoretical models, the proposed motion correction methods improved image quality by reducing motion artifacts in reconstructions; 3D warping performed better than the 2D methods, especially in off-center slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗