Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytic linearization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Application of the linac of the IREN facility for production some radionuclides and multielemental activation analysis

The possibility to develop multielemental activation analysis and production of some radionuclides widely used for the nuclear medicine, radiobiology and ecology monitoring at the linear electron accelerator (E{sub e}- = 75 MeV) of the facility IREN (FLNP, JINR) are considered. Based on the experimental data obtained at low energy (E{sub e}-<30 MeV) electron accelerators as well as the microtron MT-25 (FLNR, JINR) with the power 0.57 kW, are estimated photonuclear reaction yields for some radionuclides for the linear electron accelerator (E{sub e}- = 75 MeV). Technical parameter of the linac will be as follow as: the electron beam current 2.8 A in 100 microsecond impulse and frequency 50 Hz, that means the electron beam power -1.1 kW in the target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-perturbative many-body treatment of molecular magnets

Molecular magnets have received significant attention because of their potential applications in quantum information and quantum computing. A delicate balance of electron correlation, spin–orbit coupling (SOC), ligand field splitting, and other effects produces a persistent magnetic moment within each molecular magnet unit. The discovery and design of molecular magnets with improved functionalities would be greatly aided by accurate computations. However, the competition among the different effects poses a challenge for theoretical treatments. Electron correlation plays a central role since d- or f-element ions, which provide the magnetic states in molecular magnets, often require explicit many-body treatments. SOC, which expands the dimensionality of the Hilbert space, can also lead to non-perturbative effects in the presence of strong interaction. Furthermore, molecular magnets are large, with tens of atoms in even the smallest systems. We show how an ab initio treatment of molecular magnets can be achieved with auxiliary-field quantum Monte Carlo, in which electron correlation, SOC, and material specificity are included accurately and on an equal footing. Furthermore, the approach is demonstrated by an application to compute the zero-field splitting of a locally linear Co 2+ complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Analysis on Linac Oscillation Data LI05-19 and Wake Field Energy Loss in FACET Commissioning 2012

In this note, preliminary analysis on linac ocsillation data in FACET linac LI05-09 plus LI11-19 is presented. Several quadrupoles are identified to possibly have different strength, compared with their designed strength in the MAD optics model. The beam energy loss due to longitudinal wake fields in the S-band linac is also analytically calculated, also by LITRACK numerical simulations.

43 PARTICLE ACCELERATORS↗

VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Nanotube Fiber Ionization Mass Spectrometry: A Fundamental Study of a Multi-Walled Carbon Nanotube Functionalized Corona Discharge Pin for Polycyclic Aromatic Hydrocarbons Analysis

Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R{sup 2}) of three target PAHs with phenanthrene internal standard. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Fragment Molecular Orbital Method Based on Long-Range Corrected Density-Functional Tight-Binding

The presently available linear scaling approaches to density-functional tight-binding (DFTB) based on the fragment molecular orbital (FMO) method are severely impacted by the problem of artificial charge transfer due to the self-interaction error (SIE), which hampers the simulation of zwitterionic systems such as biopolymers or ionic liquids. Here we report an extension of FMO-DFTB where we included a long-range corrected (LC) functional designed to mitigate the DFTB SIE, called the FMO-LC-DFTB method, resulting in a robust method which succeeds in simulating zwitterionic systems. Both energy and analytic gradient are developed for the gas phase and the polarizable continuum model of solvation. The scaling of FMO-LC-DFTB with system size N is shown to be almost linear, O( N 1.13–1.28 ), and its numerical accuracy is established for a variety of representative systems including neutral and charged polypeptides. It is shown that pair interaction energies between fragments for two mini-proteins are in excellent agreement with results from long-range corrected density functional theory. Here the new method was employed in long time scale (1 ns) molecular dynamics simulations of the tryptophan cage protein (PDB: 1L2Y) in the gas phase for four different protonation states and in stochastic global minimum structure searches for 1-ethyl-3-methylimidazolium nitrate ionic liquid clusters containing up to 2300 atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soft mean spherical approximation for dusty plasma liquids: Level of accuracy and analytic expressions

The soft mean spherical approximation is employed for the study of the thermodynamics of dusty plasma liquids, the latter treated as Yukawa one-component plasmas. Within this integral theory method, the only input necessary for the calculation of the reduced excess energy stems from the solution of a single non-linear algebraic equation. Consequently, thermodynamic quantities can be routinely computed without the need to determine the pair correlation function or the structure factor. The level of accuracy of the approach is quantified after an extensive comparison with numerical simulation results. The approach is solved over a million times with input spanning the whole parameter space and reliable analytic expressions are obtained for the basic thermodynamic quantities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinklike structures in an arcsin real scalar dynamics

Highlights: • Kinklike analyses in a real scalar theory with an arcsin dynamic. • First-order formalism implementation and deformation procedure in an arcsin scalar dynamics. In this paper, we analyze kink-like analytical solutions in a real scalar theory with an arcsin dynamics inspired by the arcsin electrodynamics presented in Kruglov (2015). This analysis is done by means of the first-order formalism. This formalism provides a framework where the equations of motion can be simplified by preserving the linear stability of the theory. In this work, the deformation procedure is implemented with the aim of finding exact solutions in systems with generalized dynamics. Along the paper, we explore how the first-order formalism is implemented in the arcsin kinetics and how such a term influences the kink-like solutions. As a part of the result of our paper, we show that the kink-like solutions are similar to the ones obtained in the standard scalar kinetic theory. We also show that the extra parameter, that controls the non-linearities of the model, plays an essential role in the energy densities and stability potentials. These quantities vary according to this parameter. The goals here are to show how the first-order framework is implemented in this arcsin scenario and to present the analytical kink-like solutions that can be found by means of the first-order framework and deformation method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Communication: Charge-population based dispersion interactions for molecules and materials

We introduce a system-independent method to derive effective atomic C{sub 6} coefficients and polarizabilities in molecules and materials purely from charge population analysis. This enables the use of dispersion-correction schemes in electronic structure calculations without recourse to electron-density partitioning schemes and expands their applicability to semi-empirical methods and tight-binding Hamiltonians. We show that the accuracy of our method is en par with established electron-density partitioning based approaches in describing intermolecular C{sub 6} coefficients as well as dispersion energies of weakly bound molecular dimers, organic crystals, and supramolecular complexes. We showcase the utility of our approach by incorporation of the recently developed many-body dispersion method [Tkatchenko et al., Phys. Rev. Lett. 108, 236402 (2012)] into the semi-empirical density functional tight-binding method and propose the latter as a viable technique to study hybrid organic-inorganic interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Method Development and Validation of Naloxone and 6α‐naloxol from Male African Green Monkey Plasma.

Theopioid epidemic is a rapidly growing crisis around the world. Current models forpharmacokinetic assessment of countermeasures use African green monkeys (AGM). Arapid, sensitive and selective method was developed and validated usingLC‐MS/MS for the determination of naloxone and 6α‐naloxol in AGM plasma. Samplepreparation involved a simple solid phase extraction (SPE) using ahydrophilic‐lipophilic‐balanced reversed‐phase cartridge. Separation of naloxoneand 6α‐naloxol was achieved on a Halo C18, 2.1 × 50 mm, 2.7μ analytical columnusing an Agilent 1290 Infinity HPLC. A solvent system of methanol‐water‐formicacid was used for the elution of analytes. The analytes were detected and monitoredby a SCIEX QTRAP 6500 + triple quadrupole tandem mass spectrometer operatedin electrospray ionization (ESI) positive mode and multiple reaction monitoring(MRM). Molecular ion transitions for naloxone, 6α‐naloxol and naloxone‐D5 were 328.0/212.0,330.0/185.0, and 333.1/212.0 m/z, respectively. The method was validated usingcalibration and recovery assays with spiked samples. Linear calibration curveswere generated over the range of 1.5–100 ng/ml with values for the coefficientof determination (R 2 ) of >0.9950. The values for both inter‐dayand intra‐day precision and accuracy were well within the generally acceptedcriteria for analytical methods (≤15%). This method was subsequentlyused to measure plasma concentrations of naloxone and 6α‐naloxol in male AGMs administerednaloxone subcutaneously and intravenously. The developed method demonstratedexcellent recovery, repeatability, accuracy and sensitivity. Support or Funding Information DISCLAIMERS. The views expressed in this abstractare those of the authors (s) and do not reflect the official policy of theDepartment of Army, Department of Defense, or U. S. Government. This researchwas supported by the Defense Threat Reduction Agency – Joint Science andTechnology office, Medical S&T Division. Thisproject was supported in part by an appointment to the Research ParticipationProgram for the U.S. Army Medical Research and Materiel Command administratedby the Oak Ridge Institute for Science and Education through an agreementbetween the U.S. Army Medical Research and Materiel Command. This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Bandaru, Veera Venkata Ratnam↗

Cell Based Volume Integration for Boundary Integral Analysis

The evaluation of volume integrals that arise in boundary integral formulations for non-homogeneous problems is considered. Using the 'Galerkin vector' to represent the Green's function, the volume integral is decomposed into a boundary integral plus a simpler volume integral wherein the source function is everywhere zero on the boundary. This new volume integral can be evaluated using a regular grid of cells covering the domain, with all cell integrals, including partial cells at the boundary, evaluated by simple linear interpolation of vertex values. For grid vertices that lie close to the boundary, the near-singular integrals are handled by partial analytic integration. The method employs a Galerkin approximation and is presented in terms of the 3D Poisson problem. An axi-symmetric formulation is also presented, and in this setting, the solution of a nonlinear problem is considered.

99 GENERAL AND MISCELLANEOUS↗

Electrochemical Modeling of PID Leakage Current of PV Modules: Steady-State Current, Transient Current, and RC-Equivalent Circuit

Potential-induced degradation (PID) remains a significant reliability concern for photovoltaic (PV) modules, arising when a voltage difference between the module frame and the solar cells drives unintended leakage current through the glass-encapsulant stack. Although PID ultimately manifests as PID-s, PID-p, or PID-c, the underlying behavior of the leakage current-its magnitude and time dependence-requires clearer electrochemical interpretation. Traditional explanations attribute the initial transient current to bulk capacitive elements of the glass, encapsulant, and antireflection coatings, and the steady-state current according to their effective ohmic resistance. More recent studies, however, indicate that electrochemical charge-transfer processes at the encapsulant-metallization interface can play a dominant role in defining the leakage-current path. This paper develops a unified electrochemical framework for modeling PID leakage current. First, an RC-equivalent circuit is formulated by combining conventional RC elements with a Randles-type interface to capture transient leakage current through double-layer capacitance and faradaic processes at ionic-electronic boundaries. Second, the steady-state current-voltage behavior is explained using a linearized Butler-Volmer relationship, showing that the measured ohmic response corresponds to the low-overpotential limit of charge-transfer kinetics. Analytical results demonstrate that, for typical module materials-3.2-mm soda-lime glass and 0.45-mm encapsulant-the dominant modulators to PID leakage current are the glass surface resistance (under dry-surface conditions), the glass bulk capacitance, and the encapsulant resistance (under wet-surface conditions), with soda lime glass surface and EVA/POE encapsulant resistances primarily governing steady-state current. The proposed electrochemical model is validated against measured leakage-current data, showing good agreement in both the magnitude and the time-dependent evolution of PID leakage current.

14 SOLAR ENERGY↗

Solving phase appearance/disappearance two-phase flow problems with high resolution staggered grid and fully implicit schemes by the Jacobian-free Newton–Krylov Method

The phase appearance/disappearance issue presents serious numerical challenges in two-phase flow simulations. Many existing reactor safety analysis codes use different kinds of treatments for the phase appearance/disappearance problem. However, to our best knowledge, there are no fully satisfactory solutions. Additionally, the majority of the existing reactor system analysis codes were developed using low-order numerical schemes in both space and time. In many situations, it is desirable to use high-resolution spatial discretization and fully implicit time integration schemes to reduce numerical errors. In this work, we adapted a high-resolution spatial discretization scheme on staggered grid mesh and fully implicit time integration methods (such as BDF1 and BDF2) to solve the two-phase flow problems. The discretized nonlinear system was solved by the Jacobian-free Newton Krylov (JFNK) method, which does not require the derivation and implementation of analytical Jacobian matrix. These methods were tested with a few two-phase flow problems with phase appearance/disappearance phenomena considered, such as a linear advection problem, an oscillating manometer problem, and a sedimentation problem. The JFNK method demonstrated extremely robust and stable behaviors in solving the two-phase flow problems with phase appearance/disappearance. No special treatments such as water level tracking or void fraction limiting were used. High-resolution spatial discretization and second- order fully implicit method also demonstrated their capabilities in significantly reducing numerical errors.

97 MATHEMATICS AND COMPUTING↗

A Hybridizable Discontinuous Galerkin solver for the Grad–Shafranov equation

In axisymmetric fusion reactors, the equilibrium magnetic configuration can be expressed in terms of the solution to a semi-linear elliptic equation known as the Grad–Shafranov equation, the solution of which determines the poloidal component of the magnetic field. When the geometry of the confinement region is known, the problem becomes an interior Dirichlet boundary value problem. We propose a high order solver based on the Hybridizable Discontinuous Galerkin method. The resulting algorithm (1) provides high order of convergence for the flux function and its gradient, (2) incorporates a novel method for handling piecewise smooth geometries by extension from polygonal meshes, (3) can handle geometries with non-smooth boundaries and x-points, and (4) deals with the semi-linearity through an accelerated two-grid fixed-point iteration. The effectiveness of the algorithm is verified with computations for cases where analytic solutions are known on configurations similar to those of actual devices (ITER with single null and double null divertor, NSTX, ASDEX upgrade, and Field Reversed Configurations).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dose Effect Relationship for Late Side Effects of the Rectum and Urinary Bladder in Magnetic Resonance Image-Guided Adaptive Cervix Cancer Brachytherapy

Purpose: To establish dose-response relationships for late side effects of the rectum and bladder in cervix cancer patients after magnetic resonance image-guided adaptive brachytherapy (IGABT). Methods and Materials: A cohort of 141 patients was treated with 45 to 50.4 Gy with or without cisplatin plus 4 fractions of 7 Gy IGABT. Doses for the most exposed 2, 1, and 0.1-cm{sup 3} (D{sub 2cc}, D{sub 1cc}, D{sub 0.1cc}) volumes of the rectum and bladder were converted into the equivalent dose in 2 Gy fractions (EQD2), using a linear quadratic model ({alpha}/{beta} = 3 Gy). Late side effects were prospectively assessed (using late effects in normal tissues subjective, objective, management and analytic [LENT SOMA]) scales. Dose-response relationships were determined by logit analyses. Results: Eleven patients developed rectal side effects, and 23 patients had urinary side effects. A significant dose effect was found for all rectal dose-volume histogram (DVH) parameters for patients with side effect grades of 1 to 4 but was only significant for D{sub 2cc} and D{sub 1cc} for grades {>=}2. The ED10 values for D{sub 2cc} were 73 Gy for grades 1 to 4 and 78 Gy for grades 2 to 4 rectal morbidity. For bladder side effects, a significant dose effect was shown for all DVH parameters for complication grades {>=}2; the respective ED10 was 101 Gy. Conclusions: Well-defined dose-response curves could be established for D{sub 2cc} in the rectum and the urinary bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pair plasma instability in homogeneous magnetic guide fields

Pair plasmas, collections of both matter and antimatter particles of equal mass, represent a paradigm for the study of basic plasma science, and many open questions exist regarding these unique systems. They are found in many astrophysical settings, such as gamma-ray bursts, and have recently also been produced in carefully designed laboratory experiments. A central research topic in plasma physics is instability; however, unlike their more common ion–electron siblings, pair plasmas are generally thought to be stable to cross field pressure gradients in homogeneous magnetic fields. It is shown here by means of kinetic full-f simulations that, when a pressure gradient is first established, the Gradient-driven Drift Coupling mode is destabilized and becomes turbulent. Force balance is eventually achieved by a combination of flattened pressure profiles due to turbulent transport and establishment of a magnetic field gradient, saturating the growth. During the unstable phase, key physics can be captured by a δf gyrokinetic description, where it is shown analytically and numerically that parallel particle motion results in a coupling of all electromagnetic field components. A fluid model derived therefrom accurately predicts linear eigenmodes and is used to resolve global profile effects. For laser-based electron–positron plasma experiments, prompt instability is predicted with growth times much shorter than plasma lifetimes. Similarly, growth rates are calculated for the planned APEX experiment as well as gamma-ray burst scenarios, suggesting that the instability may contribute to the early evolution of these systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗