Search NASA⌕ Search

SEARCH · Search NASA

Results for “Assistant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

{sup 18}F-FDG PET/CT-imaging of left ventricular assist device infection: a retrospective quantitative intrapatient analysis

Background: Despite the use of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT), diagnosis of a driveline infection in ventricular assist device (LVAD) recipients remains challenging. Our aim was to evaluate the potential of a baseline {sup 18}F-FDG PET/CT (prior to an infection) for the diagnosis of an LVAD-related infection. Methods: We retrospectively selected all LVAD recipients who had undergone two consecutive whole-body {sup 18}F-FDG PET/CT examinations between January 2010 and December 2016. PET/CT was analyzed qualitatively (uptake pattern) and semi-quantitatively (SUV{sub max} and ∆SUV{sub max}). SUV{sub max} was measured and compared in five distinctive volumes of interest along the LVAD driveline. An SUV{sub max} threshold was calculated. Final diagnosis was made by clinical examination, microbiological parameters, and molecular imaging. Results: Thirty patients were enrolled (mean age 54 ± 12 years; 26 male). Mean difference in SUV{sub max} for all five positions between the first and the second PET/CT along the driveline was significantly higher in patients with an LVAD-related infection (mean ∆SUV{sub max} = 4.38 ± 1.44) compared to those without a driveline infection (mean ∆SUV{sub max} = 0.03 ± 0.43), P < 0.05. Applying ROC analysis, an SUV{sub max} threshold of 3.88 resulted in a sensitivity and specificity of 100%, respectively. There were three distinctive uptake patterns in patients with a driveline infection. Conclusion: PET/CT diagnosis in the context of an LVAD-related infection can be improved by comparison to a baseline examination using a distinctive SUV{sub max} threshold.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Characterization of Laser Ablation Patterns and a New Definition of Resolution in Matrix Assisted Laser Desorption Ionization Imaging Mass Spectrometry (MALDI-IMS)

Matrix assisted laser desorption ionization imaging mass spectrometry (MALDI-IMS) is a technique that has seen a sharp rise in both use and development. Despite this rapid adoption, there have been few thorough investigations into the actual physical mechanisms that underlie the acquisition of IMS images. We therefore set out to characterize the effect of IMS laser ablation patterns on the surface of a sample. We also concluded that the governing factors that control spatial resolution have not been correctly defined and therefore propose a new definition of resolution. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Pulse Width Dependence and Ionization Mechanism of Matrix-Assisted Laser Desorption/Ionization

Ultraviolet laser pulses at 355 nm with variable pulse widths in the region from 170 ps to 1.5 ns were used to investigate the ionization mechanism of matrix-assisted laser desorption/ionization (MALDI) for matrices 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), and sinapinic acid (SA). The mass spectra of desorbed ions and the intensity and velocity distribution of desorbed neutrals were measured simultaneously for each laser shot. These quantities were found to be independent of the laser pulse width. A comparison of the experimental measurements and numerical simulations according to the multiphoton ionization, coupled photophysical and chemical dynamics (CPCD), and thermally induced proton transfer models showed that the predictions of thermally induced proton transfer model were in agreement with the experimental data, but those of the multiphoton ionization model were not. Moreover, the predictions of the CPCD model based on singlet–singlet energy pooling were inconsistent with the experimental data of CHCA and SA, but were consistent with the experimental data of DHB only when some parameters used in the model were adjusted to extreme values. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of Collimating Lens Focusing on Laser Beam Shape in Matrix Assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS)

Tissue imaging using matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a well-established technique that, in recent years, has seen wider adoption and novel application. Applications such imaging mass spectrometry (IMS) and biotyping are beginning to gain greater exposure and use; however, with limitations in optimization methods, producing the best result often relies on the ability to customize the physical characteristics of the instrumentation, a task that is challenging for most mass spectrometry laboratories. With this in mind, we have described the effect of making simple adjustments to the laser optics at the final collimating lens area, to adjust the laser beam size and shape in order to allow greater customization of the instrument for improving techniques such as IMS. We have therefore been able to demonstrate that improvements can be made without requiring the help of an electrical engineer or external funding in a way that only costs a small amount of time. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerosol Vacuum-Assisted Plasma Ionization (Aero-VaPI) Coupled to Ion Mobility-Mass Spectrometry

In this communication, we report on the real-time analysis of organic aerosol particles by Vacuum-assisted Plasma Ionization-Mass Spectrometry (Aero-VaPI-MS) using a home-built VaPI ion source coupled to a Synapt G2-S HDMS ion mobility-mass spectrometry (IM-MS) system. Standards of organic molecules of interest in prebiotic chemistry were used to generate aerosols. Monocaprin and decanoic acid aerosol particles were successfully detected in both the positive and negative ion modes, respectively. A complex aerosol mixture of different sizes of polymers of L-malic acid was also examined through ion mobility (IM) separations, resulting in the detection of polymers of up to eight monomeric units. This noncommercial plasma ion source is proposed as a low cost alternative to other plasma ionization platforms used for aerosol analysis, and a higher-performance alternative to more traditional aerosol mass spectrometers. VaPI provides robust online ionization of organics in aerosols without extensive ion activation, with the coupling to IM-MS providing higher peak capacity and excellent mass accuracy. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matrix Assisted and/or Laser Desorption Ionization Quadrupole Ion Trap Time-of-Flight Mass Spectrometry of WO{sub 3} Clusters Formation in Gas Phase. Nanodiamonds, Fullerene, and Graphene Oxide Matrices

The formation of W{sub x}O{sub y}{sup +●/-●} clusters in the gas phase was studied by laser desorption ionization (LDI) and matrix assisted laser desorption ionization (MALDI) of solid WO{sub 3}. LDI produced (WO{sub 3}){sub n}{sup +●/-●} (n = 1-7) clusters. In MALDI, when using nano-diamonds (NDs), graphene oxide (GO), or fullerene (C{sub 60}) matrices, higher mass clusters were generated. In addition to (WO{sub 3}){sub n}{sup -●} clusters, oxygen-rich or -deficient species were found in both LDI and MALDI (with the total number of clusters exceeding one hundred ≈ 137). This is the first time that such matrices have been used for the generation of(WO{sub 3}){sub n}{sup +●/-●} clusters in the gas phase, while new high mass clusters (WO{sub 3}){sub n}{sup -●} (n = 12-19) were also detected. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas Chromatography-Tandem Mass Spectrometry of Lignin Pyrolyzates with Dopant-Assisted Atmospheric Pressure Chemical Ionization and Molecular Structure Search with CSI:FingerID

Dopant-assisted atmospheric pressure chemical ionization (dAPCI) is a soft ionization method rarely used for gas chromatography-mass spectrometry (GC-MS). The current study combines GC-dAPCI with tandem mass spectrometry (MS/MS) for analysis of a complex mixture such as lignin pyrolysis analysis. To identify the structures of volatile lignin pyrolysis products, collision-induced dissociation (CID) MS/MS using a quadrupole time-of-flight mass spectrometer (QTOFMS) and pseudo MS/MS through in-source collision-induced dissociation (ISCID) using a single stage TOFMS are utilized. To overcome the lack of MS/MS database, Compound Structure Identification (CSI):FingerID is used to interpret CID spectra and predict best matched structures from PubChem library. With this approach, a total of 59 compounds were positively identified in comparison to only 22 in NIST database search of GC-EI-MS dataset. This study demonstrates the effectiveness of GC-dAPCI-MS/MS to overcome the limitations of traditional GC-EI-MS analysis when EI-MS database is not sufficient. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-Area Graphene Films as Target Surfaces for Highly Reproducible Matrix-Assisted Laser Desorption Ionization Suitable for Quantitative Mass Spectrometry

Due to the known sweet-spot issues that intrinsically arise from inhomogeneous formation of matrix-analyte crystals utilized as samples in matrix-assisted laser desorption ionization (MALDI) mass spectrometry, its reproducibility and thus its applications for quantification have been somewhat limited. In this paper, we report a simple strategy to improve the uniformity of matrix-analyte crystal spots, which we realized by adapting large-area graphene films, i.e., non-inert, interacting surfaces, as target surfaces. In this example, the graphitic surfaces of the graphene films interact with excess matrix molecules during the sample drying process, which induces spontaneous formation of optically uniform MALDI sample crystal layers on the film surfaces. Further, mass spectrometric imaging reveals that the visible uniformity is indeed accompanied by reproducible MALDI ionization over an entire sample spot, which greatly suppresses the appearance of sweet spots. The results of this study confirm that the proposed method achieves good linear responses of ion intensity to the analyte concentration (R{sup 2} > 0.99) with small relative standard deviations (σ < 10%), which is a range applicable for quantitative measurements using MALDI mass spectrometry. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dual-Channel Enzymatic Inhibition Measurement (DEIM) Coupling Isotope Substrate via Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry

A novel dual-channel enzymatic inhibition measurement (DEIM) method was developed to improve the repeatability with light/heavy isotope substrates, producing reliable relative standard deviations (< 3%) by employing acetylcholinesterase (AChE) as the model enzyme. The matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) was adapted for enzyme-inhibited method due to its good salt-tolerance and high throughput; meanwhile, dual-channel enzymatic reactions were performed to improve the repeatability of each well. The acetylcholinesterase inhibition measurement was conducted by mixing the quenched enzyme reaction solution of blank group (with heavy isotope as substrate) and experimental group (with light isotope as substrate), of which the inhibition rate might be affected by isotope effects. Hence, inverse study and Km measurement were implemented to validate the method. The inverse study shows similar inhibition rate (68.9 and 70.3%) and the Km of isotope substrates are analogous (0.139 and 0.135 mM), which demonstrated that the novel method is feasible to AChE inhibition measurement. Finally, the method was applied to herb extracts, half of which exhibit inhibition to AChE. The precise dual-channel enzymatic inhibition measurement (DEIM) method could be regarded as a promising approach to potential enzyme inhibitor screening. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parameters, Properties, and Process: Conditional Neural Generation of Realistic SEM Imagery Toward ML-Assisted Advanced Manufacturing

Abstract The research and development cycle of advanced manufacturing processes traditionally requires a large investment of time and resources. Experiments can be expensive and are hence conducted on relatively small scales. This poses problems for typically data-hungry machine learning tools which could otherwise expedite the development cycle. We build upon prior work by applying conditional generative adversarial networks (GANs) to scanning electron microscope (SEM) imagery from an emerging advanced manufacturing process, shear-assisted processing and extrusion (ShAPE). We generate realistic images conditioned on temper and either experimental parameters or material properties. In doing so, we are able to integrate machine learning into the development cycle, by allowing a user to immediately visualize the microstructure that would arise from particular process parameters or properties. This work forms a technical backbone for a fundamentally new approach for understanding manufacturing processes in the absence of first-principle models. By characterizing microstructure from a topological perspective, we are able to evaluate our models’ ability to capture the breadth and diversity of experimental scanning electron microscope (SEM) samples. Our method is successful in capturing the visual and general microstructural features arising from the considered process, with analysis highlighting directions to further improve the topological realism of our synthetic imagery.

36 MATERIALS SCIENCE↗

Manufacturing of magnesium/aluminum bimetallic ring components by friction stir assisted simultaneous forging and solid-state joining

Here, a bimetallic ring component is forged by a friction stir assisted forging (FS-forging). A cylindrical bimetallic blank, magnesium AZ31 cylinder (Mg core) tightly fitted inside an aluminum 6061-T6 tube (Al skin), is used. In the FS-forging, the frictional heat and stirring of rotating tool forge the blank into a desired shape, while simultaneously generate a solid-state joint between the Mg core and the Al skin, without additional external heating, as confirmed by the microstructural analysis and mechanical tests. The microstructural analysis also shows that the characteristics of the solid-state joint can be different depending on the process parameters.

42 ENGINEERING↗

Grid-assisted magnetron sputtering deposition of nitrogen graded TiN thin films

Titanium Nitride (TiN) films were obtained using the grid-assisted magnetron sputtering deposition technique on Al substrates in two conditions: under constant and variable nitrogen concentration along the thin solid film thickness. The formation of a film with variable N concentration (herein referred as graded film) was confirmed using energy filtered transmission electron microscopy, X-ray photoelectron spectroscopy and grazing incidence X-ray diffraction. The TiN thin films microstructures were also analysed using scanning and transmission electron microscopies (SEM and TEM). Finally, the viability of synthesizing TiN thin films with variable N concentration is herein proposed as an alternative method for tailoring the properties of such functional coating materials.

36 MATERIALS SCIENCE↗

Dislocation channel broadening–A new mechanism to improve irradiation-assisted stress corrosion cracking resistance of additively manufactured 316 L stainless steel

Additively manufactured (AM) 316 L stainless steel (SS) after hot isostatic pressing (HIP) was found to exhibit superior resistance to irradiation-assisted stress corrosion cracking (IASCC) in high-temperature water, as compared to wrought 316 L SS. The well-accepted IASCC factors of radiation-induced segregation (RIS) and radiation hardening are not accurate descriptions of IASCC susceptibility in this case. A decreased strain localization along grain boundaries, caused by dislocation channel broadening, was confirmed to suppress crack initiation. A unique distribution of irradiation-induced defects in HIP AM 316 L SS eased dislocation cross-slip compared to those in the wrought counterpart, thus increasing the channel width near the grain boundaries. Here for the first time, this study highlights the importance of dislocation channel broadening as a potential mechanism to further improve the IASCC resistance of 316 L SS and provides direct experimental evidence based on commercial-grade materials.

316L stainless steel↗

Multi-objective surrogate-assisted calibration of CPFEM models using macroscopic response and in situ EBSD measurements of grain reorientation trajectories

Crystal plasticity finite element method (CPFEM) models are widely used to simulate the deformation behaviour of polycrystalline materials, but their calibration is often limited by their high computational cost and the non-convexity of the optimisation landscape. Here, this study develops a multi-objective surrogate-assisted calibration workflow that couples a multi-objective genetic algorithm (MOGA) with an adaptively trained deep neural network (DNN) surrogate model to efficiently identify CPFEM parameters from experimental data. The workflow is demonstrated on three crystal plasticity (CP) formulations of increasing complexity — Voce hardening (VH), two-coefficient latent hardening (LH2), and six-coefficient latent hardening (LH6) — using in situ electron backscatter diffraction (EBSD) measurements of Alloy 617 under uniaxial tensile loading. The CPFEM models are calibrated against the experimentally observed stress–strain response and reorientation trajectories of eight grains, then validated against eight additional trajectories and overall texture evolution. Across the CP formulations, the macroscopic response was reproduced reliably, while differences emerged in the robustness and accuracy of the grain-scale predictions. Including grain reorientation trajectories in the multi-objective calibration improved texture evolution predictions and filtered out physically inconsistent parameter sets that can arise from calibrating against only the stress–strain data. The workflow also demonstrates good transferability of calibrated parameters from a low- to a high-fidelity microstructural model. These results provide practical guidance for integrating in situ microstructural data into CPFEM through efficient, repeatable, and physically meaningful multi-objective calibration.

Crystal plasticity finite element method↗

Refined hyperentanglement purification of two-photon systems for high-capacity quantum communication with cavity-assisted interaction

Hyperentanglement, defined as the entanglement in multiple degrees of freedom (DOFs) of a photonic quantum system, has attracted much attention recently as it can improve the channel capacity of quantum communication largely. Here we present a refined hyperentanglement purification protocol (hyper-EPP) for two-photon systems in mixed hyperentangled states in both the spatial-mode and polarization DOFs, assisted by cavity quantum electrodynamics. By means of the spatial (polarization) quantum state transfer process, the quantum states that are discarded in the previous hyper-EPPs can be preserved. That is, the spatial (polarization) state of a four-photon system with high fidelity can be transformed into another four-photon system with low fidelity, not disturbing its polarization (spatial) state, which makes this hyper-EPP take the advantage of possessing a higher efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Classical-driving-assisted entanglement dynamics control

We propose a scheme of controlling entanglement dynamics of a quantum system by applying the external classical driving field for two atoms separately located in a single-mode photon cavity. It is shown that, with a judicious choice of the classical-driving strength and the atom–photon detuning, the effective atom–photon interaction Hamiltonian can be switched from Jaynes–Cummings model to anti-Jaynes–Cummings model. By tuning the controllable atom–photon interaction induced by the classical field, we illustrate that the evolution trajectory of the Bell-like entanglement states can be manipulated from entanglement-sudden-death to no-entanglement-sudden-death, from no-entanglement-invariant to entanglement-invariant. Furthermore, the robustness of the initial Bell-like entanglement can be improved by the classical driving field in the leaky cavities. This classical-driving-assisted architecture can be easily extensible to multi-atom quantum system for scalability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heralded quantum gates for atomic systems assisted by the scattering of photons off single emitters

Quantum logic gates are essential in quantum information processing. Here, we propose three heralded schemes for universal quantum gates, including the controlled-NOT, Toffoli, and Fredkin gates on atomic systems, assisted by the scattering of photons off single emitters in one-dimensional waveguides. Interestingly, our schemes can turn faulty scattering processes of photons off atoms into the detection of the photon polarization. Furthermore, auxiliary atomic qubits are not needed and only one photon medium is adopted. With current technology, we discuss the feasibility of these universal quantum gates, concluding that they are feasible and scalable in solid-state quantum systems. We provide a different method for realizing universal quantum gates, and it may be useful in quantum information processing in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-thermal plasma-assisted steam methane reforming for electrically-driven hydrogen production

Plasma-assisted steam methane reforming (SMR) has become a promising approach for low temperature and small-scale hydrogen production. To increase H 2 yields, water-gas-shift reactions are needed to drive the formed CO to CO 2 and H 2 . In this study, bulk gas temperature, plasma power and water feed rate strongly impacted the CO and CO 2 product selectivity at high methane conversions of 60–80% in the presence of a Ni-based catalyst. CO 2 -enriched hydrogen could be formed directly with H 2 O/methane ratios > 4. To further increase the CO 2 /CO product selectivity, a “one-pot” cascade design with a Cu/ZnO/Al 2 O 3 /MgO catalyst bed placed downstream of the plasma zone achieved substantially higher CO 2 /CO selectivity (>15) in the effluent gas at 60% methane conversion and 300°C. Comparably, placing the Cu-based catalyst in the plasma zone does not alter the CO 2 /CO selectivity. Further, this study highlights the use of plasma reactor systems to directly tune the catalytic SMR performance and lead to an electrified route for hydrogen production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗