Search NASASearch

SEARCH · Search NASA

Results for “Bio-based materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,053 records · Page 59

Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an in situ alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

general physics

High Pressure X-ray Diffraction and Equation of State of Hydrazine

Synchrotron X-ray diffraction has been used to investigate the structure and equation of state (EOS) of hydrazine (N 2 H 4 ) up to 54.3 GPa at 298 K. The diffraction patterns could be fit to a monoclinic unit-cell structure and put strong constraints on previously reported phase transitions documented by vibrational spectroscopy over this pressure range. Pressure–volume ( P–V ) data were fit using a Vinet EOS, yielding parameters: V 0 = 45.2 Å 3 /molecule (fixed), K 0 = 11.8(7) GPa, and K 0 ′ = 6.5(2). Previously measured high-pressure vibrational frequency shifts were used to estimate the vibrational free energy and model P–V–T isotherms from 0 to 1200 K. The results of the P–V–T isotherms are compared to existing shock Hugoniot data on hydrazine and 298 K isotherms for assemblages of possible decomposition products. This comparison suggests dissociation at high density under shock loading. Good correspondence was found between the static lattice EOS as calculated by the model and the previously reported EOS as calculated by density functional theory. Finally, these results resolve existing uncertainties about the EOS and crystal symmetry of hydrazine at high pressure and provide valuable baseline information on this important energetic material.

diffraction

Dark Energy Survey Year 6 results: Clustering redshifts and importance sampling of self-organized-maps 𝑛⁡(𝑧) realizations for 3 × 2 ⁢pt samples

This work is part of a series establishing the redshift framework for the 3 × 2 ⁢pt analysis of the Dark Energy Survey Year 6 (DES Y6). For DES Y6, photometric redshift distributions are estimated using self-organizing maps (SOMs), calibrated with spectroscopic and many-band photometric data. To overcome limitations from color-redshift degeneracies and incomplete spectroscopic coverage, we enhance this approach by incorporating clustering-based redshift constraints (clustering-z, or WZ) from angular cross-correlations with BOSS and eBOSS galaxies and eBOSS quasar samples. We define a WZ likelihood and apply importance sampling to a large ensemble of SOM-derived 𝑛⁡(𝑧) realizations, selecting those consistent with the clustering measurements to produce a posterior sample for each lens and source bin. The analysis uses angular scales corresponding to 1.5–5 Mpc to optimize signal-to-noise ratio while mitigating modeling uncertainties and marginalizes over redshift-dependent galaxy bias and other systematics informed by the N-body simulation CARDINAL . While a sparser spectroscopic reference sample limits WZ constraining power at 𝑧 >1.1, particularly for source bins, we demonstrate that combining SOM with WZ improves redshift accuracy and enhances the overall cosmological constraining power of DES Y6. As a result, we estimate an improvement in 𝑆 8 of approximately 10% for cosmic shear and 3 ×2⁢pt analysis, primarily due to the WZ calibration of the source samples.

Cosmological parameters

Software Validation Work With The ZPPR-15 Data

The analysis activities for fast reactors involve using many different pieces of software that are relied upon for their predictive capabilities. For this software to be considered reliable, documented proof that the predictions of the software are accurate is required. In this manuscript, the validation work that covers some of the Argonne software used in fast reactor design activities is discussed and displayed. This validation work includes neutron and gamma flux distributions, reaction rate distributions, and reactivity worth. In an ideal world, a reactor development program would have access to a comprehensive set of experimental facilities to help inform the design aspects of the reactor itself. While thermal-hydraulics experiments, and to a limited degree mechanical experiments, can be carried out today for validation needs, neutronics related experimental facilities are rather impractical because of the lack of experimental facilities. Given the desired time table for construction of new reactors, the reconstitution or creation of new neutronic experimental facilities is untenable and thus those reactor development programs must rely upon any available experimental measurements that are qualitatively similar to the design. While a methodology has been proposed to assess the similarity between the past experimental measurements and the reactor itself, that aspect is beyond the scope of this manuscript. In this manuscript, the focus is entirely placed on the analysis results for a series of experiments carried out at the ZPPR facility in Idaho in the mid-1980s. In this regard, this manuscript only shows the validation of the stated neutronics software for specific loadings of the ZPPR reactor. Because of the fuel form, its proposed enrichment, and the material content of the reactor core, the ZPPR-15 experiments were identified as potential validation data for the reactor. The ZPPR-15 experiments were intended as mockups of a 330 MWe Integral Fast Reactor program which was a follow on program to the Clinch River Breeder Reactor. In the ZPPR-15 series of experiments, measurements of the neutron spectrum, control rod worth, sodium void worth, foil reaction rate distributions, Doppler worth of heated samples, gamma dose, and axial expansion worth were all carried out and published. In many cases, these reactivity coefficients are good candidates to validate the reactivity coefficient calculation scheme used by the analysis software and included in the safety analysis activities of fast reactor development projects today. This manuscript discusses the modeling methodology and accuracy of the calculated experimental results using the LANL software MCNP and the ANL software package ARC (Argonne Reactor Codes). As will be shown, for many of the experimental measurements, the two software packages are found to be good predictive analysis tools for those experiments. In other cases, problems with the analysis methodology or underlying cross section data are exposed which indicates where predictive analysis is not as reliable. Finally, in some of the measurements the conclusion is reached that the experimental measurement cannot be reproduced with the analysis software as it is simply too difficult.

Aliberti, Gerardo

SPT clusters with DES and HST weak lensing. II. Cosmological constraints from the abundance of massive halos

We present cosmological constraints from the abundance of galaxy clusters selected via the thermal Sunyaev-Zel’dovich (SZ) effect in South Pole Telescope (SPT) data with a simultaneous mass calibration using weak gravitational lensing data from the Dark Energy Survey (DES) and the Hubble Space Telescope (HST). The cluster sample is constructed from the combined SPT-SZ, SPTpol ECS, and SPTpol 500d surveys, and comprises 1,005 confirmed clusters in the redshift range 0.25–1.78 over a total sky area of 5200 deg 2 . We use DES Year 3 weak-lensing data for 688 clusters with redshifts 𝑧 < 0.95 and HST weak-lensing data for 39 clusters with 0.6 < 𝑧 < 1.7. The weak-lensing measurements enable robust mass measurements of sample clusters and allow us to empirically constrain the SZ observable-mass relation without having to make strong assumptions about, e.g., the hydrodynamical state of the clusters. For a flat Λ⁢ CDM cosmology, and marginalizing over the sum of massive neutrinos, we measure Ω m = 0.286 ± 0.032, 𝜎 8 = 0.817 ± 0.026, and the parameter combination 𝜎 8 ⁢(Ω m /0.3) 0.25 = 0.805 ± 0.016. Our measurement of 𝑆 8 ≡ 𝜎 8 ⁢$\sqrt{Ω_{m}/0.3}$ = 0.795 ± 0.029 and the constraint from Planck CMB anisotropies (2018 TT, TE, EE+lowE) differ by 1.1⁢𝜎. In combination with that Planck dataset, we place a 95% upper limit on the sum of neutrino masses ∑𝑚 𝜈 < 0.18 eV. When additionally allowing the dark energy equation of state parameter 𝑤 to vary, we obtain 𝑤 = −1.45 ± 0.31 from our cluster-based analysis. In combination with Planck data, we measure 𝑤 =−1.3⁢4$^{+0.22}_{−0.15}$, or a 2.2⁢𝜎 difference with a cosmological constant. We use the cluster abundance to measure 𝜎8 in five redshift bins between 0.25 and 1.8, and we find the results to be consistent with structure growth as predicted by the Λ⁢ CDM model fit to Planck primary CMB data.

79 ASTRONOMY AND ASTROPHYSICS

Nonlinear reversal of photoexcitation on the attosecond time scale improves ultrafast X-ray diffraction images

The complex refractive index of a material governs its light-matter interactions, with intense light fields enabling tailored nonlinear optical responses. In the X-ray regime, rapid photoionization limits the potential of nonlinear techniques by inducing irreversible electronic damage. Here we demonstrate that intense, sub-femtosecond X-ray pulses, shorter than typical Auger decay times, can partially reverse photoexcitation via stimulated emission near atomic resonances. By analyzing thousands of coherent diffraction patterns and ion spectra from neon nanoparticles exposed to sub-fs and 15-fs pulses, we observe enhanced X-ray diffraction alongside reduced energy absorption for sub-fs pulses. Theoretical modeling attributes this to dynamics akin to Rabi flopping that prolong the lifetime of resonant states and suppress electronic bleaching. These findings suggest that ultrashort, intense X-ray pulses enable active control of X-ray refractive index and damage pathways, opening avenues for improved high-resolution imaging and nonlinear spectroscopy in complex nanoscale systems.

Ulmer, Anatoli [Universität Hamburg (Germany)] (OR

Application of Nuclear Technology to Art Identification Problems: First Annual Report

Throughout the centuries, as man has become increasingly affluent, his interest in antiquities and objects of art, and the price he has been willing to pay for them, has increased. Inevitably, one result has been to attract the unscrupulous to the production and sale of counterfeit paintings, sculptures, and other works of art. The skill of forgers varies but often is highly sophisticated. However, dealers, museum curators, and other experts have also become more skillful in the detection of forgeries. Scientific tools of increasing sensitivity and sophistication have gradually been applied to the examination of the materials of art and archaeology. Such tools frequently support and render more reliable the judgment of the experts. The quality of forgeries may improve further as their makers become acquainted with the new methods of detection and in turn learn to circumvent or confound the methods. Therefore, the development of still more advanced methods of examination has great utility in the art world. This is particularly true if the ultimate effect is to make circumvention of the methods of examination so costly that the economic incentives for producing forgeries may be substantially reduced, if not eliminated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Single-Nucleon Transfer on Unstable 59 Cu Probes the NiCu Cycle in Astrophysical X-Ray Bursts

Recent models of the rapid proton (𝑟⁢𝑝) capture process indicate that a competition between the 59 Cu⁢(𝑝,𝛾) ⁢60 Zn and 59 Cu⁢(𝑝,𝛼) ⁢56 Ni reactions may result in the formation of a nickel-copper (NiCu) cycle that traps the flux of material between 56 Ni and 60 Zn . Here, in this work, we report the identification of 15 proton-unbound levels in 60 Zn , populated via 59 Cu⁢(𝑑,𝑛) transfer, which govern the rate of the 59 Cu⁢(𝑝,𝛾)⁢ 60 Zn reaction in XRBs. Precise excitation energies for levels in 60 Zn were obtained from observed 𝛾 decays, and spectroscopic factors were determined from angle-integrated cross sections. Incorporating these results into stellar-model calculations, we find that with experimentally constrained uncertainties a NiCu cycle in XRBs is indeed possible, though we limit its branching strength to less than 38%. While modest, such a branching has significant impact on the light curve, motivating further studies of the relevant rates. Our calculations also indicate that a significant NiCu cycle leads to an increase in the amount of odd-𝐴 nuclei in the burst ashes, which may affect Urca cooling processes in neutron star crusts.

direct reactions

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS