Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Expanding Energy Performance Contracting in china: policy solutions and market mechanisms

Energy performance contracting is an important market mechanism that uses energy savings to pay over time for the upfront costs of energy efficiency retrofits in buildings, industries, and other types of facilities. Through energy performance contracts (EPCs), Energy Service Companies (ESCOs) play an important role in implementing energy efficiency retrofits. Both China and the United States have large markets for EPCs and significant opportunities for growth. The Chinese government has made great efforts in promoting the country’s ESCO business and expanding its EPC markets. This paper makes a series of recommendations for China to adopt more ambitious policy measures to encourage deep energy savings projects via EPCs. These recommendations are built on initial insights from a white paper developed by researchers at the Pacific Northwest National Laboratory and the Lawrence Berkeley National Laboratory with the assistance from the ESCO Committee of China’s Energy Conservation Association (EMCA). Key recommendations are listed below.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial Building Energy Asset Rating Program -- Market Research

Under contract to Pacific Northwest National Laboratory, HaydenTanner, LLC conducted an in-depth analysis of the potential market value of a commercial building energy asset rating program for the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy. The market research objectives were to: (1) Evaluate market interest and need for a program and tool to offer asset rating and rapidly identify potential energy efficiency measures for the commercial building sector. (2) Identify key input variables and asset rating outputs that would facilitate increased investment in energy efficiency. (3) Assess best practices and lessons learned from existing national and international energy rating programs. (4) Identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to adopt a voluntary asset rating program and, as a consequence, deploy high-performance strategies and technologies across new and existing buildings. (5) Identify leverage factors and incentives that facilitate increased investment in these buildings. To meet these objectives, work consisted of a review of the relevant literature, examination of existing and emergent asset and operational rating systems, interviews with industry stakeholders, and an evaluation of the value implication of an asset label on asset valuation. This report documents the analysis methodology and findings, conclusion, and recommendations. Its intent is to support and inform the DOE Office of Energy Efficiency and Renewable Energy on the market need and potential value impacts of an asset labeling and diagnostic tool to encourage high-performance new buildings and building efficiency retrofit projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of a Hot-Dry Climate Whole-House Retrofit

The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Implementation for Transforming a Home Energy Management System to a Multi-agent System

In the United States, 41% of produced energy is consumed by the building sector, i.e. residential and commercial buildings (Building Energy Data Book, Buildings Sector, US Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Office, 2012. n.d.). The anticipation is that Home Energy Management Systems (HEMS) will support energy efficiency gains through control of the devices in an optimal fashion. New opportunities are offering the ability to integrate grid type controls and the most suitable way to perform these controls is through a multi-agent system (MAS). In this paper, approaches on supporting a HEMS and MAS integration are discussed.

Zandi, Helia↗

Procedures for Calculating Residential Dehumidification Loads

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

47 OTHER INSTRUMENTATION↗

DeepHyper: A Python Package for Massively Parallel Hyperparameter Optimization in Machine Learning

Machine learning models are increasingly applied across scientific disciplines, yet their effectiveness often hinges on heuristic decisions—such as data transformations, training strategies, and model architectures—that are not learned by the models themselves. Automating the selection of these heuristics and analyzing their sensitivity is crucial for building robust and efficient learning workflows. DeepHyper addresses this challenge by democratizing hyperparameter optimization, providing accessible tools to streamline and enhance machine learning workflows from a laptop to the largest supercomputer in the world. Building on top of hyperparameter optimization, it unlocks new capabilities around ensembles of models for improved accuracy and uncertainty quantification. All of these organized around efficient parallel computing.

ensemble↗

Transparent window film with embedded nano-shades for thermoregulation

Every year, more than 20% of the energy consumption in the United States and more than 10% of the global consumption is used towards HVAC (Heating, Ventilating, Air-Conditioning) systems in buildings. Although continued efforts in advancing renewable energy, efficient appliances, and smart building systems are desired, the most critical factors that cause extensive indoor energy consumption are thermal leakage and thermal waste generation. We demonstrate a smart window film that allows natural lighting with a clear view while blocking oblique incident sunlight to make the building interior cooler without using electricity or generating heat. Building upon the concept of, often overlooked, traditional window shades and privacy window films, we emphasize and elevate the application and impact of using magnetically arranged nanoscale material for energy conservation purpose in buildings. By embedding vertically aligned Ni flakes (VANF) in a polymer matrix film, nanoscale mirror array serve as shades to block the high-angled incident sunlight, blocking approximately 73% of total solar irradiance and bringing down the indoor temperature by 1.92 °C during the daytime in a model house while providing nearly 90% transparency. Global application was simulated by applying the respective solar angle and intensity at selected latitudes, indicating their potential. This passively energy-conserving smart film is a low cost, maintenance free, and simple product for users and easy-to-manufacture product for the industry.

36 MATERIALS SCIENCE↗

A Business Case for Home Performance Contracting

This report was prepared by PNNL for the DOE Building America program. The report provides information for businesses considering entering the home performance contracting industry. Metrics discussed include industry trends and drivers, specific points of entry, business models, startup costs, and marketing strategies. The report includes detailed analysis of eight businesses around the country that have successfully entered the home performance contracting industry. Data is provided on their financial structures, program participation, marketing efforts, and staff training. This report will be distributed via the DOE Building America website, www.buildingamerica.gov. Individual case studies will also be cleared separately.

Building America↗

Technology Solutions Case Study: Improving the Field Performance of Natural Gas Furnaces

The objective of this project is to examine the impact that common installation practices and age-induced equipment degradation may have on the installed performance of natural gas furnaces, as measured by steady-state efficiency and AFUE. PARR identified twelve furnaces of various ages and efficiencies that were operating in residential homes in the Des Moines Iowa metropolitan area and worked with a local HVAC contractor to retrieve them and test them for steady-state efficiency and AFUE in the lab. Prior to removal, system airflow, static pressure, equipment temperature rise, and flue loss measurements were recorded for each furnace. After removal from the field the furnaces were transported to the Gas Technology Institute (GTI) laboratory, where PARR conducted steady-state efficiency and AFUE testing. The test results show that steady-state efficiency in the field was 6.4% lower than that measured for the same furnaces under standard conditions in the lab, which included tuning the furnace input and air flow rate. Comparing AFUE measured under ASHRAE standard conditions with the label value shows no reduction in efficiency for the furnaces in this study over their 15 to 24 years of operation when tuned to standard conditions. Further analysis of the data showed no significant correlation between efficiency change and the age or the rated efficiency of the furnace.

AFUE↗

Demand Control Ventilation - Code Notes

A demand control ventilation system is an integral part of a building’s ventilation design. It adjusts outside ventilation air based on the number of occupants and the ventilation demands that those occupants create.

HVAC, sensors and controls, building energy effici↗

Energy Efficiency and Conservation Block Grant (EECBG): Better Buildings Neighborhood Program Final Report

The Neighbor to Neighbor Energy Challenge (N2N) brought together a consortium of 14 leading clean energy rural, suburban, and low income communities throughout Connecticut. N2N was awarded $4.2 million from the U.S. Department of Energy (DOE) competitive BetterBuildings Neighborhood Program on August 10, 2010 to run a two-year pilot program (plus one year of transition and evaluation) (Award No. EMCBC- 00969-10). N2N tested innovative program models and hypotheses for improving Connecticut’s existing residential energy efficiency programs that are overseen by the ratepayer fund board and administered by CT utilities. N2N’s original goal was to engage 10 percent of households in participating communities to reduce their energy usage by 20 percent through energy upgrades and clean energy measures. N2N planned for customers to complete more comprehensive whole-home energy efficiency and clean energy measures and to achieve broader penetration than existing utility-administered regulated programs. Since this was an ARRA award, we report the following figures on job creation in Table 1. Since N2N is not continuing in its current form, we do not provide figures on job retention. Table 1 N2N Job Creation by Quarter Jobs Created 2010 Q4 6.65 2011 Q1 7.13 2011 Q2 4.98 2011 Q3 9.66 2011 Q4 5.43 2012 Q1 11.11 2012 Q2 6.85 2012 Q3 6.29 2012 Q4 6.77 2013 Q1 5.57 2013 Q2 8.35 2013 Q3 6.52 Total 85.31 The N2N team encountered several gaps in the existing efficiency program performance that hindered meeting N2N’s and DOE’s short-term program goals, as well as the State of Connecticut’s long-term energy, efficiency, and carbon reduction goals. However, despite the slow program start, N2N found evidence of increasing upgrade uptake rates over time, due to delayed customer action of one to two years from N2N introduction to completion of deeper household upgrades. Two main social/behavioral principles have contributed to driving deeper upgrades in CT: 1. Word of mouth, where people share their experience with others, which leads to others to take action; and 2. Self-herding, where people follow past behavior, which leads to deeper and deeper actions within individual households.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy and Energy Cost Savings Analysis of the 2018 IECC for Commercial Buildings

The U.S. Department of Energy (DOE) Building Energy Codes Program supports the development and implementation of building energy codes and standards, which set minimum requirements for energy-efficient design and construction for new and renovated buildings, and impact energy use and greenhouse gas emissions for the life of buildings. As required by federal statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2016 would achieve greater energy efficiency in buildings compared to the 2013 edition of the standard. In support of DOE’s determination, Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2016 (DOE 2017). While Standard 90.1 is the national model energy standard for commercial buildings (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether new buildings constructed to the commercial energy efficiency provisions of the 2018 IECC would save energy and energy costs as compared to the 2015 IECC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)

The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit energy efficiency measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings nationwide. U.S. K-12 school districts spend more than $8 billion each year on energy - more than they spend on computers and textbooks combined. Most occupy older buildings that often have poor operational performance - more than 30% of schools were built before 1960. The average age of a school is about 42 years - which is nearly the expected serviceable lifespan of the building. K-12 schools offer unique opportunities for deep, cost-effective energy efficiency improvements, and this guide provides convenient and practical guidance for exploiting these opportunities in the context of public, private, and parochial schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A concept of integrated environmental approach for building upgrades and new construction: Part 1—setting the stage

This article highlights the need for an active role for building physics in the development of near-zero energy buildings while analyzing an example of an integrated system for the upgrade of existing buildings. The science called either Building Physics in Europe or Building Science in North America has so far a passive role in explaining observed failures in construction practice. In its new role, it would be integrating modeling and testing to provide predictive capability, so much needed in the development of near-zero energy buildings. The authors attempt to create a compact package, applicable to different climates with small modifications of some hygrothermal properties of materials. This universal solution is based on a systems approach that is routine for building physics but in contrast to separately conceived sub-systems that are typical for the design of buildings today. One knows that the building structure, energy efficiency, indoor environmental quality, and moisture management all need to be considered to ensure durability of materials and control cost of near-zero energy buildings. These factors must be addressed through contributions of the whole design team. The same approach must be used for the retrofit of buildings. As this integrated design paradigm resulted from demands of sustainable built environment approach, building physics must drop its passive role and improve two critical domains of analysis: (i) linked, real-time hygrothermal and energy models capable of predicting the performance of existing buildings after renovation and (ii) basic methods of indoor environment and moisture management when the exterior of the building cannot be modified.

Building physics↗

City of Indianapolis Better Buildings Program

In June 2010, the City of Indianapolis’ Office of Sustainability was awarded $10 million in grant funds through the U.S. Department of Energy’s Better Buildings Neighborhood Program (CFDA 81.128) funded by the 2009 American Recovery and Reinvestment Act. The purpose of the grant funds was to achieve energy savings in residential and commercial buildings through energy efficiency upgrades such as air sealing and insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗