Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Effect of a Second-Order Phase Transition on the Electrical Conductivity of Metal/Semiconductor Structures

The properties of the Cr–p-Si potential barrier near the temperature of the antiferromagnetic–paramagnetic phase transition in chromium are investigated. A significant change in the potential barrier and an anomalous increase in the conductivity in the Cr–p-Si–Au structure are observed near the temperature of the second-order antiferromagnetic–paramagnetic phase transition in chromium. It is established that current fluctuations in the structure are enhanced when approaching the phase-transition point. The experimental results are interpreted based on the assumption that the observed change in the electron-transport properties of the Cr–Si interface is due to a shift of the Fermi quasi-level in chromium as a result of the second-order phase transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron Paramagnetic Resonance of Cr{sup 3+} Ions in Single Crystals of Yttrium Aluminum Borate YAl{sub 3}(BO{sub 3}){sub 4}

Single crystal of yttrium aluminum borate YAl{sub 3}(BO{sub 3}){sub 4} doped with chromium ions (1 at %) was studied using electron paramagnetic resonance spectroscopy. It is shown that chromium ions introduced into the sample occupy yttrium ion sites in the crystal structure. The parameters of the spin Hamiltonian of Cr{sup 3+} ions in the YAl{sub 3}(BO{sub 3}){sub 4} matrix are determined at different temperatures. The sign of the fine structure parameter D allows the conclusion that the chromium ions in YA1{sub 3}(BO{sub 3}){sub 4} single crystals have an easy-plane anisotropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Innovative System for the Efficient and Effective Treatment of Non-Traditional Waters for Reuse in Thermoelectric Power Generation

This study assessed opportunities for improving water quality associated with coal-fired power generation including the use of non-traditional waters for cooling, innovative technology for recovering and reusing water within power plants, novel approaches for the removal of trace inorganic compounds from ash pond effluents, and novel approaches for removing biocides from cooling tower blowdown. This research evaluated specifically designed pilot-scale constructed wetland systems for treatment of targeted constituents in non-traditional waters for reuse in thermoelectric power generation and other purposes. The overall objective of this project was to decrease targeted constituents in non-traditional waters to achieve reuse criteria or discharge limitations established by the National Pollutant Discharge Elimination System (NPDES) and Clean Water Act (CWA). The six original project objectives were completed, and results are presented in this final technical report. These objectives included identification of targeted constituents for treatment in four non-traditional water sources, determination of reuse or discharge criteria for treatment, design of constructed wetland treatment systems for these non-traditional waters, and measurement of treatment of targeted constituents in non-traditional waters, as well as determination of the suitability of the treated non-traditional waters for reuse or discharge to receiving aquatic systems. The four non-traditional waters used to accomplish these objectives were ash basin water, cooling water, flue gas desulfurization (FGD) water, and produced water. The contaminants of concern identified in ash basin waters were arsenic, chromium, copper, mercury, selenium, and zinc. Contaminants of concern in cooling waters included free oxidants (chlorine, bromine, and peroxides), copper, lead, zinc, pH, and total dissolved solids. FGD waters contained contaminants of concern including arsenic, boron, chlorides, selenium, mercury, chemical oxygen demand (COD), and zinc. Similar to FGD waters, produced waters contained contaminants of concern that are predominantly inorganic (arsenic, cadmium, chlorides, chromium, copper, lead, mercury, nickel, sulfide, zinc, total dissolved solids), but also contained some organics (benzene, PAHs, toluene, total organic carbon, total suspended solids, and oil and grease). Constituents of concern that may cause chemical scaling, biofouling and corrosion, such as pH, hardness and ionic strength, and nutrients (P, K, and N) may also be found in all four non-traditional waters. NPDES permits were obtained for these non-traditional waters and these permit limits are summarized in tabular format within this report. These limits were used to establish treatment goals for this research along with toxicity values for Ceriodaphnia dubia, water quality criteria established by the US EPA, irrigation standards established by the United States Department of Agriculture (USDA), and reuse standards focused on minimization of damage to the power plant by treated waters. Constructed wetland treatment systems were designed for each non-traditional water source based on published literature reviews regarding remediation of the constituents of concern, biogeochemistry of the specific contaminants, and previous research. During this study, 4 non-traditional waters, which included ash basin water, cooling water, FGD water and produced water (PW) were obtained or simulated to measure constructed wetland treatment system performance. Based on data collected from FGD experiments, pilot-scale constructed wetland treatment systems can decrease aqueous concentrations of elements of concern (As, B, Hg, N, and Se). Percent removal was specific for each element, including ranges of 40.1% to 77.7% for As, 77.6% to 97.8% for Hg, 43.9% to 88.8% for N, and no measureable removal to 84.6% for Se. Other constituents of interest in final outflow samples should have aqueous characteristics sufficient for discharge, with the exception of chlorides (<2000 mg/L). Based on total dissolved solids, co-management or ion reduction (e.g. reverse osmosis, nanofiltration, ultrafiltration, etc.) techniques will be needed for discharge or reuse of high ionic strength waters. Data collected from produced water experiments indicate that hybrid pilot-scale constructed wetland treatment systems can decrease aqueous concentrations of elements of concern (Zn, Cd, Pb, and Cu). Percent removal was specific for each element, including ranges of 38.4% to 99.6% for Cd, 90.6% to 99.8% for Cu, 93.1% to 99.3% for Pb, and 40.0% to 99.8% for Zn. Reuse of these waters will likely depend on the chloride concentration of the outflow samples, but with use of reverse osmosis technology, chloride concentrations can be decreased sufficiently for reuse as service water. Concentrations of arsenic, selenium, chromium, and zinc were decreased in ash basin waters by pilot-scale constructed wetland treatment systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of Antifoam Agent on Oxidative Leaching of Hanford Tank Sludge Simulants

Oxidative leaching of simulant tank waste containing an antifoam agent (AFA) to reduce the chromium content of the sludge was tested using permanganate as the oxidant in 0.25 M NaOH solutions. AFA is added to the waste treatment process to prevent foaming. The AFA, Dow Corning Q2-3183A, is a surface-active polymer that consists of polypropylene glycol, polydimethylsiloxane, octylphenoxy polyethoxy ethanol, treated silica, and polyether polyol. Some of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) waste slurries contain high concentrations of undissolved solids that would exhibit undesirable behavior without AFA addition. These tests were conducted to determine the effect of the AFA on oxidative leaching of Cr(III) in waste by permanganate. It has not previously been determined what effect AFA has on the permanganate reaction. This study was conducted to determine the effect AFA has on the oxidation of the chromium, plus plutonium and other criticality-related elements, specifically Fe, Ni and Mn. During the oxidative leaching process, Mn is added as liquid permanganate solution and is converted to an insoluble solid that precipitates as MnO2 and becomes part of the solid waste. Caustic leaching was performed followed by an oxidative leach at either 25°C or 45°C. Samples of the leachate and solids were collected at each step of the process. Initially, Battelle-Pacific Northwest Division (PNWD) was contracted by Bechtel National, Inc. to perform these further scoping studies on oxidative alkaline leaching. The data obtained from the testing will be used by the WTP operations to develop procedures for permanganate dosing of Hanford tank sludge solids during oxidative leaching. Work was initially conducted under contract number 24590-101-TSA-W000-00004. In February 2007, the contract mechanism was switched to Pacific Northwest National Laboratory (PNNL) operating Contract DE-AC05-76RL01830. In summary, this report describes work focused on determining the effect of AFA on chromium oxidation by permanganate with Hanford sludge simulant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NASA and ESA Collaboration on Hexavalent Chrome Alternatives: Pretreatments Only Final Test Report

Hexavalent chromium (hex chrome or CR(VI)) is a widely used element within applied coating systems because of its self-healing and corrosion-resistant properties. The replacement of hex chrome in the processing of aluminum for aviation and aerospace applications remains a goal of great significance. Aluminum is the major manufacturing material of structures and components in the space flight arena. The National Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) are engaged in a collaborative effort to test and evaluate alternatives to hexavalent chromium containing corrosion coating systems. NASA and ESA share common risks related to material obsolescence associated with hexavalent chromium used in corrosion-resistant coatings.

RoHS↗

Influence of Carbon Sources and Electron Shuttles on Ferric Iron Reduction by Cellulomonas sp. Strain ES6

The reduction of hexavalent chromium, Cr(VI), to trivalent chromium, Cr(III), can be an important aspect of remediation processes at Department of Energy (DOE) and other contaminated sites. Cellulomonas species are found at several Cr(VI) contaminated and uncontaminated locations at the DOE site in Hanford, Washington. Members of this genus have demonstrated the ability to effectively reduce Cr(VI) to Cr(III) fermentatively and therefore play a potential role in hexavalent chromium remediation at this site. Batch studies were conducted with Cellulomonas sp. strain ES6 to assess the influence of various carbon sources, iron minerals, and electron shuttling compounds on Cr(VI) reduction. These chemical species are likely to be present in these terrestrial environments during in situ bioremediation. Results indicated that there were a number of interactions between these compounds that influenced Cr(VI) reduction rates. The type of carbon source as well as the type of electron shuttle present influenced Cr(VI) reduction rates. When an electron shuttle, such as anthraquinone-2,6-disulfonate (AQDS), was present in the system, reduction rates increased significantly. Biologically reduced AQDS (AHDS) reduced Cr(VI) almost instantaneously. The presence of iron minerals and their concentrations did not significantly influence Cr(VI) reduction rates. However, strain ES6 or AQDS could directly reduce surface-associated Fe(III) to Fe(II) which was capable of reducing Cr(VI) at a near instantaneous rate. These results suggest the rate limiting step in these systems is the transfer of electrons from strain ES6 to the intermediate or terminal electron acceptor whether that is Cr(VI), Fe(III), or AQDS.

60 APPLIED LIFE SCIENCES↗

Startup of the New 200 West Pump-and-Treat, Hanford Site, Richland, Washington - 13214

On June 28, 2012, CH2M HILL Plateau Remediation Company (CHPRC) completed the construction and acceptance testing for a new 2,500 gallon-per-minute (gpm) pump-and-treat (P and T) system in the 200 West Area of the Hanford Site in Washington State. This system is designed to remove Tc-99, carbon tetrachloride, trichloroethene (TCE), nitrate, and total and hexavalent chromium from groundwater using ion exchange, anoxic and aerobic bioreactors, and air stripping. The system will eventually remove uranium from groundwater using ion exchange as well. The startup of the P and T system is important because it will ensure that contaminants from the 200 West Area never reach the Columbia River. When fully operational, the 200 West P and T will include approximately 23 extraction wells and 21 injection wells. The extraction wells are 8 inches in diameter, are completed with well screens 100 feet or more in length, and are distributed throughout the central portion of the 5-square-mile carbon tetrachloride plume. The injection wells are also 8 inches in diameter and are installed up-gradient of the plumes to recharge the aquifer and down-gradient of the plumes for flow-path control. Groundwater in the 200 West Area is approximately 250 feet below ground surface, and the aquifer is 200 feet or more in thickness. All of the contaminants (except nitrate) are found within the perimeter of the carbon tetrachloride plume and occur at various depths throughout the aquifer. The 200 West P and T consists of two separate buildings to conduct groundwater treatment. The RAD building contains an ion exchange system to remove Tc-99 from groundwater at a maximum flow rate of 600 gpm. The RAD building only accepts water from those extraction wells showing elevated Tc-99 concentrations. Groundwater initially fills an influent tank, is then pumped through particulate filters (to remove suspended materials), and then passes through two parallel treatment trains containing Purolite{sup R} A530E resin (which has been proven effective in removing Tc-99). The water is then transferred to the biological treatment building for further treatment. When the lead vessel in each of the two treatment trains becomes fully loaded with Tc-99, the Purolite A530E resin is transferred to a separate tank where it is heated to 160 deg. F to remove volatile organics prior to disposal at the Environmental Restoration Disposal Facility. The biological treatment building has a maximum flow capacity of 2,500 gpm. Groundwater from the nonradiological extraction wells and treated groundwater from the RAD building are initially pumped into an equalization tank and then into two parallel fluidized bed reactors (FBRs). The FBRs contain granulated activated carbon in suspension for microbes to populate, a carbon-based food source for the microbes to eat (e.g., MicroCg{sup TM}, molasses, or sodium lactate), and nitrate for the microbes to breathe (represents 'anoxic' conditions that contain little or no dissolved oxygen). The FBRs are maintained at a temperature between 55 deg. F and 90 deg. F, and at a pH between 6.5 and 6.8, to maximize microbial growth. The FBRs break down the nitrate, reduce the hexavalent chromium to trivalent chromium, and break down a good portion of the carbon tetrachloride and TCE. From the FBRs, groundwater is pumped through a carbon separation tank, then through a splitter box that divides the water evenly between four membrane bioreactors (MBRs) that further break down the contaminants. The MBRs have aeration capacity to provide sufficient oxygen for maintaining the aerobic biological process. The MBRs use submerged membranes for filtration. Vertically strung fibers are found in the membrane zone where a vacuum draws water through tiny pores in the fibers. The liquid is then pumped to air strippers to remove any volatile organics that have passed through the bioreactors. Solids from the MBRs are pumped to rotary drum thickeners and centrifuges for dewatering prior to lime being added to kill the bacteria and control odor. The conditioned sludge is then disposed at the Environmental Restoration Disposal Facility. The final treated water is then pumped to the injection well field. The 200 West P and T is a Leadership in Energy and Environmental Design (LEED) gold-certified facility that has an expected 70% energy cost savings over the lifetime of the plant. Fifty percent of the steel used in construction was recycled, 420 tons of recycled concrete were used, and over 75% of construction waste was diverted from landfills. The plant is only staffed one shift per day, and it uses a call-out system if the plant goes down during off-shift hours. Initial sampling results have shown that the 200 West P and T is successfully reducing contaminant levels well below the cleanup levels specified in the Record of Decision, Hanford 200 Area 200-ZP-1 Superfund Site, Benton County, Washington [1]. CHPRC and the U.S. Department of Energy are continuing to look for ways to reduce operational costs, such as testing alternative resins for removing radionuclides and finding less expensive carbon substrate sources. The benefit to others is a LEED gold-certified, 2,500 gpm P and T system that may be used as a model for other complex sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chromate Removal by Long Life IX Resins Without Continuous pH Adjustment - 20083

Long life resins are available for chromate removal from water but have traditionally had the disadvantage of requiring pH adjustment, first to reduce pH before treatment, and then to raise pH following treatment. The requirement for double pH adjustment leads to a significant increase in TDS, added complexity, risks associated with the use of strong acids and bases, and the ongoing costs of purchasing and using these chemicals. The mechanism of removal in long life resins used for chromate removal is ion exchange, followed by reduction of hexavalent chromium to trivalent chromium, followed by immobilization of trivalent chromium within the IX resin polymer. The second step is rate limiting and pH dependent and is the reason why lowering pH before treatment has until now been necessary. However, there is a reasonably simple way to use these long life resins that does not require continuous pH adjustment. By taking a portion of the treatment vessels off line and soaking them in a low pH solution, the rate constant for the reduction step is increased sufficiently to catch up, making the ion exchange step the limiting factor. The long life resin is effectively regenerated by the low pH soaks. Rejuvenated resin beds can then be put back on line and operated at the natural pH of the feedwater. This method of operation is protected by US Patent no. US20150136706A1. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Degradation of SOFCs in contact with E-brite.

The results presented in this report seem to raise concerns about the effects of chromium at lower temperature and higher current densities. However, we need to remember that these results were obtained withuncoated E-Brite and coated material would have two orders of magnitude lower formation rates of the oxyhydroxide. More importantly, the dramatic effects of the chromium precipitation at lower temperature point to the solution to the problem. We need more active cathodes. The results with the chromium doped manganite show already that the currently preferred cathode material can still be improved, and ferrites or mixed manganese/iron cathode would be much less affected because of the higher oxide ion vacancy concentration and mobility.

36 MATERIALS SCIENCE↗

Synthesis and characterization of Cr-MSU-1 and its catalytic application for oxidation of styrene

Chromium-containing mesoporous silica material Cr-MSU-1 was synthesized using lauryl alcohol-polyoxyethylene (23) ether as templating agent under the neutral pH condition by two-step method. The sample was characterized by XRD, TEM, FT-IR, UV-Vis, ESR, ICP-AES and N{sub 2} adsorption. Its catalytic performance for oxidation of styrene was studied. Effects of the solvent used, the styrene/H{sub 2}O{sub 2} mole ratio and the reaction temperature and time on the oxidation of styrene over the Cr-MSU-1 catalyst were examined. The results indicate that Cr ions have been successfully incorporated into the framework of MSU-1 and the Cr-MSU-1 material has a uniform worm-like holes mesoporous structure. After Cr-MSU-1 is calcined, most of Cr{sup 3+} is oxidized to Cr{sup 5+} and Cr{sup 6+} in tetrahedral coordination and no extra-framework Cr{sub 2}O{sub 3} is formed. The Cr-MSU-1 catalyst is highly active for the selective oxidation of styrene and the main reaction products over Cr-MSU-1 are benzaldehyde and phenylacetaldehyde. Its catalytic performance remains stable within five repeated runs and no leaching is noticed for this chromium-based catalyst. - Graphical abstract: Mesoporous Cr-MSU-1 with worm-like holes was synthesized by a novel two-step method. The Cr-MSU-1 material is highly active and stable for the selective oxidation of styrene.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Incorporation of trace metals in Hanford waste boehmite mineral phases and dissolution rate impacts

Abstract Data from radioactive Hanford tank waste samples was analyzed to assess whether trace metals present were incorporated into the bulk boehmite matrix or were simply intermingled with the bulk material and subsequent impacts to the boehmite dissolution rate. Results suggest that chromium is primarily blended into the bulk boehmite, with a small fraction present on the surface of the solids. However, increasing the level of chromium incorporation 30‐fold decreased the dissolution rate of boehmite by only 8%, suggesting incorporation of chromium into these samples had a minimal impact on the dissolution rate. Iron was also found to be incorporated in the boehmite solids. Silicon appears to be simply intermingled and not blended into the boehmite crystals.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Porous Salts as Platforms for Heterogeneous Catalysis

In this study, the preparation of a new class of reactive porous solids, prepared via straightforward salt metathesis reactions, is described here. Reaction of the dimethylammonium salt of a magnesium-based porous coordination cage with the chloride salt of [Cr II Cl(Me 4 cyclam)] + affords a porous solid with concomitant removal of dimethylammonium chloride. The salt consists of the ions combined in the expected ratio based on their charge as confirmed by UV–vis and X-ray photoelectron spectroscopies, ion chromatography (IC), and inductively coupled plasma mass spectrometry (ICP-MS). The porous salt boasts a Brunauer-Emmett-Teller (BET) surface area of 213 m 2 g -1 . Single crystal X-ray diffraction reveals the chromium(II) cations in the structure reside in the interstitial space between porous cages. Importantly, the chromium(II) centers, previously shown to react with O 2 to afford reactive chromium(III)-superoxide adducts, are still accessible in the solid state as confirmed by UV–vis spectroscopy. The site-isolated reactive centers have competence toward hydrogen atom abstraction chemistry and display significantly increased stability and reactivity as compared to dissolved ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cr-free Fe-based metal oxide catalysts for high temperature water gas shift reaction of fuel processor using LPG

The goal of this study was to identify the most suitable chromium-free iron-based catalysts for the HTS (high temperature shift) reaction of a fuel processor using LPG. Hexavalent chromium (Cr6+) in the commercial HTS catalyst has been regarded as hazardous material. We selected Ni and Co as the substitution for chromium in the Fe-based HTS catalyst and investigated the HTS activities of these Crfree catalysts at LPG reformate condition. Cr-free Fe-based catalysts which contain Ni, Zn, or Co instead of Cr were prepared by coprecipitation method and the performance of the catalysts in HTS was evaluated under gas mixture conditions (42% H2, 10% CO, 37% H2O, 8% CO2, and 3% CH4; R (reduction factor): about 1.2) similar to the gases from steam reforming of LPG (100% conversion at steam/carbon ratio = 3), which is higher than R (under 1) of typically studied LNG reformate condition. Among the prepared Cr-free Febased catalysts, the 5 wt%-Co/Fe/20 wt%-Ni and 5 wt%-Zn/Fe/20 wt%-Ni catalysts showed good catalytic activity under this reaction condition simulating LPG reformate gas.

02 PETROLEUM↗

Radiation tolerance of neutron-irradiated model Fe-Cr-Al alloys

The Fe Cr Al alloy system has the potential to form an important class of enhanced accident-tolerant cladding materials in the nuclear power industry owing to the alloy system's higher oxidation resistance in high-temperature steam environments compared with traditional zirconium-based alloys. However, radiation tolerance of Fe Cr Al alloys has not been fully established. In this study, a series of Fe Cr Al alloys with 10 18 wt % Cr and 2.9 4.9 wt % Al were neutron irradiated at 382 C to 1.8 dpa to investigate the irradiation-induced microstructural and mechanical property evolution as a function of alloy composition. Dislocation loops with Burgers vector of a/2 111 and a 100 were detected and quantified. Results indicate precipitation of Cr-rich is primarily dependent on the bulk chromium composition. Mechanical testing of sub-size-irradiated tensile specimens indicates the hardening response seen after irradiation is dependent on the bulk chromium composition. Furthermore, a structure property relationship was developed; it indicated that the change in yield strength after irradiation is caused by the formation of these radiation-induced defects and is dominated by the large number density of Cr-rich α' precipitates at sufficiently high chromium contents after irradiation.

36 MATERIALS SCIENCE↗

Mechanical properties of neutron-irradiated model and commercial FeCrAl alloys

The development and understanding of the mechanical properties of neutron-irradiated FeCrAl alloys is increasingly a critical need as these alloys continue to become more mature for nuclear reactor applications. This study focuses on the mechanical properties of model FeCrAl alloys and of a commercial FeCrAl alloy neutron-irradiated to up to 13.8 displacements per atom (dpa) at irradiation temperatures between 320 and 382 °C. Tensile tests were completed at room temperature and at 320 °C, and a subset of fractured tensile specimens was examined by scanning electron microscopy. Results showed typical radiation hardening and embrittlement indicative of high chromium ferritic alloys with strong chromium composition dependencies at lower doses. At and above 7.0 dpa, the mechanical properties saturated for both the commercial and model FeCrAl alloys, although brittle cleavage fracture was observed at the highest dose in the model FeCrAl alloy with the highest chromium content (18 wt %). Finally, the results suggest the composition and microstructure of FeCrAl alloys plays a critical role in the mechanical response of FeCrAl alloys irradiated near temperatures relevant to light water reactors.

36 MATERIALS SCIENCE↗

Grand potential sintering simulations of doped UO 2 accident-tolerant fuel concepts

Chromium-doped UO is a widely-studied near-term deployable accident-tolerant fuel concept because it results in a dense, large-grain structure that increases the fuel resistance to densification, swelling, and fission gas release. A new charged-interstitial mechanism was recently proposed to describe the behavior of dopants like chromium in sintered UO 2 . Based on that mechanism, manganese was suggested as an even stronger dopant than chromium. In the current work we use mesoscale sintering simulations in an effort to validate the new mechanism. We compare the relative behavior of Cr-doped and undoped UO 2 against experimental data in the literature. We also make predictions of the relative behavior of Mn-doped UO 2 . Simulations are done using the phase field-based grand potential sintering model. Dopants have two effects on sintered UO 2 . They marginally increase the densification rate and greatly increase the average grain size. Both of these effects are individually tested in small-scale simulations. Then large 3D sintering simulations are used to test the combined behavior of both effects. The results for the densification rate simulations are consistent with experiments for Cr-doped fuels. However, we note the grain growth rates are lower than what is found in the literature for Cr-doped fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Effects of Mixing Multi-Component HLW Glasses on Spinel Crystal Size

The Hanford Waste Treatment and Immobilization Plant will vitrify radioactive waste into borosilicate glass. The high-level waste (HLW) glass formulations are constrained by processing and property requirements, including restrictions aimed at avoiding detrimental impacts of spinel crystallization in the melter. To understand the impact of glass chemistry on crystallization, two HLW glasses precipitating small (?5 µm) spinel crystals were individually mixed with a glass that precipitated large (?45 µm) spinel crystals in ratios of 25, 50, and 75 wt%. The size of spinel crystals in the mixed glasses varied from 5 to 20 µm. Small crystal size was attributed to: (1) high concentrations of nuclei due to the presence of ruthenium oxide and (2) chromium oxide aiding high rates of nucleation. Results indicate that the spinel crystal size can be controlled using chromium oxide and/or noble metal concentrations in the melt, even in complex mixtures like HLW glasses. Small crystals tend to settle slowly, so they are acceptable in the melter without a risk of failure. Allowing higher concentrations of spinel-forming waste components in the waste glass enables glass compositions with higher waste loading, thus increasing plant operational flexibility. An additional benefit to the presence of chromium oxide in the glass composition is the potential for the oxide to protect melter walls against corrosion.

Lonergan, Charmayne E.↗

Interaction of beryllium with 316H stainless steel in molten Li 2 BeF 4 (FLiBe)

The increased demand in renewable energy resources has led to a renewed interest in nuclear reactors including a new generation of molten salt reactors. One of the issues encountered in handling of molten chloride or fluoride salts is the inability of metals to form and retain a protective oxide surface layer, generally chromium oxide. The low chromium content, nickel-based alloy INOR-8, later marketed as Hastelloy N, was specifically developed to contain molten fluorides. This alloy had some deficiencies, but its composition resulted in it incurring far less chromium depletion by the molten fluoride salts than alloys like 316 stainless steel. For the next generation of molten salt reactors, an alloy with pressure vessel code approval and higher temperature capability than Hastelloy N is required. Consequently, several reactor designers have reportedly chosen to build the reactor containment vessel from 316H stainless steel. In order to minimize corrosion of the stainless steel by the molten fluoride salt (2LiF-BeF 2 ), it is proposed to add beryllium metal to the salt to react with impurities and provide a means to lower the oxidation potential thus making the salt less corrosive. Even so, there is a concern whether the beryllium would react with components of the stainless steel. To address this concern, static capsule tests were conducted in which selected amounts of beryllium were added to capsules containing 2LiF-BeF 2 (FLiBe) salt and 316H stainless steel and Hastelloy N samples. Following exposure, the samples were cleaned and examined using a variety of analysis techniques including, optical microscopy, SEM-EDS, XPS, LIBS, XRD and EPMA. Tensile samples were also exposed in capsules, and those were subjected to tensile testing. Notably, It was found that for the level of beryllium additions used in this study, intermetallic compounds were formed which could be detrimental to the long-term performance of the 316H stainless steel.

36 MATERIALS SCIENCE↗