Pressure Correction in the Calibration of Heat Dissipation Sensors

Heat dissipation sensors (HDSs) infer soil matric potential based on the measured rate of temperature rise from a heat source. The process for calibrating these sensors may use a pressure plate apparatus (PPA) to remove water to a certain calibration point that is controlled by pressure. Conventionally, the pressure within the PPA is released before the temperature change calibration points are measured ( ΔT 0 ). This conventional HDS calibration approach can take several weeks. We propose that the equilibrated temperature change at pressure ( ΔT p ) can be corrected empirically to the value at zero pressure. Based on measurements of 14 HDSs between 0.02 and 0.1 MPa, ΔT p was on average 6.2% larger than ΔT 0 . After pressure correction, using an empirical equation, the difference between the corrected ΔT p and ΔT 0 was only 0.28%. These results demonstrate that this empirical approach provides sufficient accuracy to achieve HDS calibration without performing a PPA pressure release.

47 OTHER INSTRUMENTATION↗

WM-SVS-TP-003, Rev. 0, effective date 10/15/2015, WM-SVS Characterization Services User-Performed Calibration (UPC) Program

Los Alamos National Laboratory (LANL) Procedure P330-2, Control and Calibration of Measuring and Test Equipment (M&TE), requires the establishment of a Measurement Assurance Program and/or a User-Performed Calibration (UPC) Process, as applicable. This UPC has been developed in accordance with the authorization provided in QPA-VAR-2013. This program ensures that qualified individuals perform measurement control and develop measurement control and calibration procedures. Nondestructive analysis (NDA) instruments used for accountability, confirmation, and verification measurements are maintained by the Waste Management Services (WM-SVS) Characterization Services Team. NDA reference standards used for instrument control and calibration are certified for use by the Standards and Calibration Laboratory (S&CL) before use. The Characterization Services Team performs the measurements, develops procedures for performing instrument UPC, and ensures the measurement systems’ control before measurements are performed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calibration of MAMBA and CRUD Sources Using Full-Core CTF+MAMBA

This report outlines a process for the deterministic calibration of MAMBA using the computational toolkit Dakota. The tools and processes for deterministic calibration have been built and are laid out in this report. While completing this milestone, issues emerged with MAMBA that resulted in delays. The consequences for these difficulties to the calibration process are briefly discussed. The report concludes with an outline of a path forward for Bayesian calibration. The Bayesian calibration will be performed next year. This process was laid out by Benjamin Collins, Robert Salko, and Adam Hetzler.

42 ENGINEERING↗

Extending Beryllium Strength Calibration To High Strain-rate Regimes

Current calibration of the PTW strength model for beryllium is accomplished using fits to Hopkinson bar experiments. Unfortunately, Hopkinson bar tests on beryllium only allow for strain-rates of up to $5 * 10^{3} s^{-1}.$ It has been shown previously that, in higher strain-rate experiments such as flyer-plate impact tests, this calibrated strength model causes simulations with beryllium to diverge from the observed response. In this work we use a particle swarm optimization algorithm to arrive at a better calibration of beryllium strength through fits to observed material responses during flyer-plate impact experiments. We show that the PTW strength model for beryllium can be tuned to provide a much better fit to flyer-plate responses. To mitigate the effect of this new calibration on fits to Hopkinson bar data we calibrate to flyer-plate impact data using only parameters within the medium strain-rate regime of the PTW model.

36 MATERIALS SCIENCE↗

Calibration and modification of the constitutive model for the mechanical response of P91

The objective of this first milestone was to calibrate and if necessary, modify a constitutive model predicting the primary and secondary creep response of P91. The overall path to be followed consists of first calibrating this constitutive model against experimental data available from the literature (this milestone). In parallel, data acquired by indentation tests will be used to calibrate the model (this involves transforming the indentation data into equivalent uniaxial tests). An overall comparison of model parameters will allow assessing to what extent these rapid tests can be used to calibrate models predicting the overall mechanical response of the bulk. Given that COVID naturally hindered the gathering of new experimental data, the choice was made to ensure that LANL would have sufficient funds in year two to perform the bulk of the new calibration work. The following report details (i) how and which of the bulk experimental data was selected, (ii) constitutive model formulation, (iii) predictions of the constitutive model: effects of imposed stress, temperature and precipitate content, (iv) future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Calibration System Report for High-Temperature Irradiation-Resistant Thermocouples

An established calibration procedure is presented for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Standard calibration curves for both an individual (i.e. case by case basis) and common calibrations is shown. The error limits within ±3 σ are ±1% for the individual calibrations and ±2% for the common calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Spectacular Viscoelastic Model Calibration for 828/D230/Alox Generated from Legacy Sandia Data

The nonlinear viscoelastic Spectacular model is calibrated to the thermo-mechanical behavior of 828/D230/Alox with an alox volume fraction of 20 %. Legacy experimental data from Sandia’s polymer properties database (PPD) is used to calibrate the model. Based on known densities of the epoxy 828/D230 and the alox filler, the alox volume fractions listed on the PPD were likely reported incorrectly. The alox volume fractions are recalculated here. Using the recalculated alox volume fractions, the PPD contains experimental data for 828/D230/Alox with alox volume fractions of 16 %, 24 %, and 33 %, so the thermo-mechanical behavior at 20 % alox volume fraction is estimated by interpolating between the bounding cases of of 16 % and 24 %. Because the Spectacularmodel can be fairly challenging to calibrate, the calibration procedure is described in detail. Several of the calibration steps involve inverse parameter identification, where an experiment is simulated and parameters are iteratively updated until the model response matches the experimental data. As the PPD does not fully describe all experimental procedures, the experimental simulations use assumed thermal and mechanical loading rates that are typical for the viscoelastic characterization of epoxies. Spectacular uses four independent relaxation functions related to volumetric (ƒ 1 ), shear (ƒ 2 ), thermal strain (ƒ 3 ), and thermal relaxations (ƒ 4 ). The previous SPEC model form, also known as the universal_polymer model, uses two independent relaxation functions related to volumetric and thermal relaxation (ƒ ν = ƒ 1 = ƒ 3 = ƒ 4 ) and shear relaxation (ƒ s = ƒ 2 ). The two constitutive choices are briefly evaluated here, where it is found that the four relaxation function approach of Spectacular was better suited for fitting the coefficient of thermal expansion during both heating and cooling.

36 MATERIALS SCIENCE↗

Automated Calibration System for Beam Current Monitor

The Beam Current Monitor (BCM) measures the instantaneous current in a beam. This work aims to develop an automated calibration system for the BCM to address the need for calibration without interrupting beam operation. We strive to create a synchronous calibration method integrated into the master timeline by utilizing the pulsed nature of synchrotrons to run calibration pulses during inter-pulse gaps. This improvement should enhance operational efficiency, ensure safe operation, and help mitigate beam loss, all by enabling intermittent calibration during the operation of the accelerator. This is accomplished by developing a Python program that interfaces with a Keithley 6221 DC and AC source and a Keithley 2182A Nanovoltmeter. The program configures both of these devices to perform a selected mode of the current sweep, allows for the initiation of the current sweep, collects the measured voltage data from the 2182A, stores the collected data to the computer in a CSV file, and graphs the collected data.

Haller, James↗

Calibration of Al7075 with Plate-Puncture Predictions

The following details calibration of a material model for Al7075-T6511. This aluminum alloy is commonly used across a host of engineering applications. Owing to its widespread prevalence, there is great benefit in improving simulation predictions for this alloy. In the present effort, a calibration is performed of its elastic-plastic response accounting for both rate and temperature dependence. The calibration is informed by a series of tests that include specimens of different geometries tested at different rates and temperatures. All specimens are derived from the same barstock, 3.5 inches in diameter. The fitted model itself uses an anisotropic, Hill yield surface coupled with a Johnson-Cook hardening model. Failure predictions are had by means of a modified Wilkins failure criterion. Following calibration of the material model, a validation exercise is performed against platepuncture experiments. These experiments include multiple probe shapes, probe diameters, and plate thicknesses. The puncture experiments are replicated in simulation with mesh studies performed to assess uncertainty. Key quantities of interest, notably the absorbed energy up to failure, are compared between simulation and experiment providing a means to assess the suitability of the calibration in puncture simulations.

36 MATERIALS SCIENCE↗

Performance and automatic calibration scheme of the waveform sampler in the ETROC2 ASIC chip

The waveform sampler in the CMS ETROC2 chip for LGAD gain aging monitoring is a 2.56-GS/s 12-bit 8x-Interleaved ADC that consists of a coarse SAR stage, and a fine stage. This architecture delivers high performance on a relatively modest 65 nm process, while requires finding up to 24 calibration constants through calibration. We developed an automatic calibration method using charge injection test data. After calibration, the baseline random error is reduced by a factor of 2.5–3 compared to the default calibration, and a 5% charge measurement precision is achieved in 15 fC charge injection tests.

Fu, Tao [Unlisted, US]↗

SBND Calibration

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber (LArTPC) serving as the near detector of the Short-Baseline Neutrino Program at Fermilab. SBND aims to make precise measurements of neutrino-argon interactions, necessitating an extensive calibration program for the LArTPC to ensure precision/accuracy in these measurements. This talk describes the use of cosmogenic, radiogenic, and neutrino interaction activity with both Monte Carlo simulation and data in calibrating the SBND subsystems of the Time Projection Chamber, Photon Detection System, and Cosmic Ray Tagger. We will highlight some of SBND's first calibration results, including electronics calibrations, measurement of the electron lifetime, shower calibration, and studies of space charge effects in the detector.

Oh, Sungbin [Fermilab]↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

Calibration of the Mu2e momentum scale using $\pi^{+}\rightarrow e^{+}\nu_{e}$ decays

The Mu2e experiment at Fermilab will search for the neutrinoless muon-to-electron conversion in the nuclear field by stopping negative muons on an Al target. The experimental signature of $\mu^{-}$ to $e^{-}$ conversion on Al is the observation of mono-energetic electrons with 104.97 MeV produced by the lepton violating reaction. Rejection of one of the most important experimental backgrounds coming from muon Decays-In-Orbit requires a momentum resolution $<1\%$ FWHM and a momentum scale calibrated to an accuracy of better than $0.1\%$ or $0.1$ MeV at an electron energy of $\sim$100 MeV. Among other momentum scale calibration techniques, the collaboration is considering using 68.9 MeV positrons from decays of stopped positive pions. This calibration measurement has a significant background dominated by the muon decays-in-flight affecting the calibration accuracy. In this article, we discuss the momentum calibration measurement results.

Tripathy, Sridhar [UC, Davis (main)] (ORCID:000000↗

Validation of Calibrated k–ε Model Parameters for Jet-in-Crossflow

Previous efforts determined a set of calibrated, optimal model parameter values for Reynolds-averaged Navier–Stokes (RANS) simulations of a compressible jet in crossflow (JIC) using a $k–ε$ turbulence model. These parameters were derived by comparing simulation results to particle image velocimetry (PIV) data of a complementary JIC experiment under a limited set of flow conditions. Here, a $k–ε$ model using both nominal and calibrated parameters is validated against PIV data acquired from a much wider variety of JIC cases, including a realistic flight vehicle. The results from the simulations using the calibrated model parameters showed considerable improvements over those using the nominal values, even for cases that were not used in the calibration procedure that defined the optimal parameters. This improvement is demonstrated using a number of quality metrics that test the spatial alignment of the jet core, the magnitudes of multiple flow variables, and the location and strengths of vortices in the counter-rotating vortex cores on the PIV planes. These results suggest that the calibrated parameters have applicability well outside the specific flow case used in defining them and that with the right model parameters, RANS solutions for the JIC can be improved significantly over those obtained from the nominal model.

42 ENGINEERING↗

The Absolute Reflectance and New Calibration Site of the Moon

How bright the Moon is forms a simple but fundamental and important question. Although numerous efforts have been made to answer this question such as use of sophisticated electro-optical measurements and suggestions for calibration sites, the answer is still debated. An in situ measurement with a calibration panel on the surface of the Moon is crucial for obtaining the accurate absolute reflectance and resolving the debate. China’s Chang’E-3 (CE-3) “Yutu” rover accomplished this type of measurement using the Visible-Near Infrared Spectrometer (VNIS). The measurements of the VNIS, which were at large emission and phase angles, complement existing measurements for the range of photometric geometry. The in situ reflectance shows that the CE-3 landing site is very dark with an average reflectance of 3.86% in the visible bands. The results are compared with recent mission instruments: the Lunar Reconnaissance Orbiter Camera (LROC) Wide Angle Camera (WAC), the Spectral Profiler (SP) on board the SELENE, the Moon Mineralogy Mapper (M{sup 3}) on board the Chandrayaan-1, and the Chang’E-1 Interference Imaging Spectrometer (IIM). The differences in the measurements of these instruments are very large and indicate inherent differences in their absolute calibration. The M{sup 3} and IIM measurements are smaller than LROC WAC and SP, and the VNIS measurement falls between these two pairs. When using the Moon as a radiance source for the on-orbit calibration of spacecraft instruments, one should be cautious about the data. We propose that the CE-3 landing site, a young and homogeneous surface, should serve as the new calibration site.

79 ASTRONOMY AND ASTROPHYSICS↗

The Open Cluster Chemical Abundances and Mapping Survey. VII. APOGEE DR17 [C/N]–Age Calibration

Large-scale surveys open the possibility to investigate Galactic evolution both chemically and kinematically; however, reliable stellar ages remain a major challenge. Detailed chemical information provided by high-resolution spectroscopic surveys of the stars in clusters can be used as a means to calibrate recently developed chemical tools for age-dating field stars. Using data from the Open Cluster Abundances and Mapping survey, based on the Sloan Digital Sky Survey/Apache Point Observatory Galactic Evolution Experiment 2 survey, we derive a new empirical relationship between open cluster stellar ages and the carbon-to-nitrogen ([C/N]) abundance ratios for evolved stars, primarily those on the red giant branch. With this calibration, [C/N] can be used as a chemical clock for evolved field stars to investigate the formation and evolution of different parts of our Galaxy. We explore how mixing effects at different stellar evolutionary phases, like the red clump, affect the derived calibration. We have established the [C/N]–age calibration for APOGEE Data Release 17 (DR17) giant star abundances to be $\mathrm{log}{[\mathrm{Age}(\mathrm{yr})]}_{\mathrm{DR}17}=10.14\,(\pm 0.08)+2.23(\pm 0.19)\,[{\rm{C}}/{\rm{N}}]$, usable for $8.62\leqslant \mathrm{log}(\mathrm{Age}[\mathrm{yr}])\leqslant 9.82$, derived from a uniform sample of 49 clusters observed as part of APOGEE DR17 applicable primarily to metal-rich, thin- and thick-disk giant stars. This measured [C/N]–age APOGEE DR17 calibration is also shown to be consistent with asteroseismic ages derived from Kepler photometry.

79 ASTRONOMY AND ASTROPHYSICS↗

RTN-117: Image Calibration and Instrument Signal Removal for the First Year of the LSST

The NSF-DOE Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) requires calibration products that provide uniform, stable, and accurate photometric and astrometric performance across the 3.2 gigapixel focal plane and throughout the 10-year survey. This paper details the algorithms and workflows used to produce instrument calibrations and remove instrumental artifacts for Data Preview 2 (DP2)---the first end-to-end processing demonstration using on-sky data with the LSST Camera (LSSTCam). We describe the verification, acceptance, and certification framework used to assess calibration quality and quantify residual systematics. We show baseline metrics on calibrated science images to evaluate the robustness of the calibration and instrument signature removal (ISR) data processing pipelines for DP2. Finally, we summarize the known limitations observed in DP2 production and outline expected algorithmic improvements for the first public LSST data release (Data Release~1, DR1).

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of platinum resistance thermometers.

Results of five years experience in calibrating about 1000 commercial platinum resistance thermometers (PRT) are reported. These PRT were relatively small and rugged, with ice-point resistances from 200 to 5000 ohms. Calibrations normalized in terms of resistance-difference ratios (Cragoe Z function) were found to be remarkably uniform for five of six different types of PRT tested, and to agree very closely with normalized calibrations of the primary reference standard type PRT. The Z function normalization cancels residual resistances which are not temperature dependent and simplifies interpolation between calibration points when the quality of a given type of PRT has been established in terms of uniform values of the Z function. Measurements at five or six well spaced base-point temperatures with Z interpolation will suffice to calibrate a PRT accurately from 4 to 900 K.

Sinclair, D. H.↗