Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Optimal control of a repowered vehicle: Plug-in fuel cell against plug-in hybrid electric powertrain

This paper describes two different powertrain configurations for the repowering of a conventional vehicle, equipped with an internal combustion engine (ICE). A model of a mid-sized ICE-vehicle is realized and then modified to model both a parallel plug-in hybrid electric powertrain and a proton electrolyte membrane (PEM) fuel cell (FC) hybrid powertrain. The vehicle behavior under the application of an optimal control algorithm for the energy management is analyzed for the different scenarios and results are compared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EnCache: A Dynamic Profiling Based Reconfiguration Technique for Improving Cache Energy Efficiency

With each CMOS technology generation, leakage energy consumption has been dramatically increasing and hence, managing leakage power consumption of large last-level caches (LLCs) has become a critical issue in modern processor design. In this paper, we present EnCache, a novel software-based technique which uses dynamic profiling-based cache reconfiguration for saving cache leakage energy. EnCache uses a simple hardware component called profiling cache, which dynamically predicts energy efficiency of an application for 32 possible cache configurations. Using these estimates, system software reconfigures the cache to the most energy efficient configuration. EnCache uses dynamic cache reconfiguration and hence, it does not require offline profiling or tuning the parameter for each application. Furthermore, EnCache optimizes directly for the overall memory subsystem (LLC and main memory) energy efficiency instead of the LLC energy efficiency alone. The experiments performed with an x86-64 simulator and workloads from SPEC2006 suite confirm that EnCache provides larger energy saving than a conventional energy saving scheme. For single core and dual-core system configurations, the average savings in memory subsystem energy over a shared baseline configuration are 30.0% and 27.3%, respectively.

Cache Energy Saving↗

Theoretical and calculable dependent variables and their covariance in nuclear data libraries [Slides]

This presentation begins by defining observables, including theoretical observable, calculable observable, and measured observable. It also provides definitions and examples of experimental effects. Additionally, uncertainty in evaluated libraries and a metric to probe evaluated uncertainty is presented. In conclusion, being related to theoretical quantities such as resonance parameters, the uncertainty in ENDF libraries (e.g., ENDF/B-VIII.0) can be overestimated because it is usually evaluated under the guidance of experimental uncertainty: lim Δσexp.corr.→0 Δσ = Δσ theoretical model . The presentation states that a clear distinction of the uncertainty between nuclear theoretical models and experimental corrections should be revisited and this is important since (e.g., transport) simulations need theoretical quantities convoluted with specific operational parameters and material configurations. It also states that strong coupling between uncertainty quantification methodologies and optimization procedures exists, and it is necessary to develop methodologies to obtain uncertainty on theoretical models from physical and mathematical constraints.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of the HV-C2 Stack Sampling Probe Location

Tests were performed to evaluate the location of the air-sampling probe in the proposed design for the Waste Treatment Plant’s HV-C2 air exhaust stack. The evaluation criteria come from ANSI/HPS N13.1-1999, “Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities.” Pacific Northwest National Laboratory conducted the tests on a 3.67:1 scale model of the stack. Limited confirmatory tests on the actual stack will need to be conducted during cold startup of the High Level Waste Treatment Facility. The tests documented here assessed the capability of the air-monitoring probe to extract a sample representative of the effluent stream in accordance with criteria in ANSI/HPS N13.1. The test parameters covered the expected range of system flowrates with both one and two operating fans. The current stack design calls for the sampling probe to be located about 10 diameters downstream of the junction of the duct from Fan A with the stack. In accordance with the statement of work and the test plan, the test measurements were made at that location and also at one point upstream and another downstream. An adjustment was made for the distance between a typical sampling probe inlet and the centerline of its mounting flange. Thus, the test measurements were made at three positions designated as Test Port 1, 2, and 3, respectively. The designed HV-C2 exhaust system includes dampers on the fan discharges. Custom-scale model dampers were fabricated to simulate the same number and configuration of damper blades shown in the design documents received from BNI. A subset of the test runs was run without the dampers to determine whether the dampers should be included in future tests on scale models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Processes, data structures, and apparatuses for representing knowledge

Processes, data structures, and apparatuses to represent knowledge are disclosed. The processes can comprise labeling elements in a knowledge signature according to concepts in an ontology and populating the elements with confidence values. The data structures can comprise knowledge signatures stored on computer-readable media. The knowledge signatures comprise a matrix structure having elements labeled according to concepts in an ontology, wherein the value of the element represents a confidence that the concept is present in an information space. The apparatus can comprise a knowledge representation unit having at least one ontology stored on a computer-readable medium, at least one data-receiving device, and a processor configured to generate knowledge signatures by comparing datasets obtained by the data-receiving devices to the ontologies.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Data structures and apparatuses for representing knowledge

Data structures and apparatuses to represent knowledge are disclosed. The processes can comprise labeling elements in a knowledge signature according to concepts in an ontology and populating the elements with confidence values. The data structures can comprise knowledge signatures stored on computer-readable media. The knowledge signatures comprise a matrix structure having elements labeled according to concepts in an ontology, wherein the value of the element represents a confidence that the concept is present in an information space. The apparatus can comprise a knowledge representation unit having at least one ontology stored on a computer-readable medium, at least one data-receiving device, and a processor configured to generate knowledge signatures by comparing datasets obtained by the data-receiving devices to the ontologies.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Miniature Inspection Robot for Restricted Access exploration (MIRRAX) - 18324

The MIRRAX remote inspection vehicle has been developed to explore and characterise enclosed legacy facilities on the Sellafield site which have limited access ports. Its re-configurable design means that it can be deployed through a 150 mm port before changing its footprint shape to provide a stable platform for mobile characterisation. It can support both geometric and radiometric scanning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Highly Automated Module Production Incorporating Advanced Light Management

The objective was to enable a high volume, cost effective solution for increasing the amount of light captured by PV modules through utilization of an advanced Light Re-directing Film and to follow a phased approach to develop and implement this new technology in order to achieve an expected power gain of up to 12 watts per module. Full size PV modules were manufactured using a new Light Redirecting Film (LRF) material applied to two different areas of PV modules in order to increase the amount of light captured by the modules. One configuration involved applying thin strips of LRF film over the tabbing ribbon on the cells in order to redirect the light that is normally absorbed by the tabbing ribbon to the active areas of the cells. A second configuration involved applying thin strips of LRF film over the white spaces between cells within a module in order to capture some of the light that is normally reflected from the white areas back through the front glass of the modules. Significant power increases of 1.4% (3.9 watts) and 1.0% (3.2 watts), respectively, compared to standard PV modules were measured under standard test conditions. The performance of PV modules with LRF applied to the tabbing ribbon was modeled. The results showed that the power increase provided by LRF depended greatly on the angle of incident light with the optimum performance only occurring when the light was within a narrow range of being perpendicular to the solar module. The modeling showed that most of the performance gain would be lost when the angle of incident light was greater than 28 degrees off axis. This effect made the orientation of modules with LRF applied to tabbing ribbons very important as modules mounted in “portrait” mode were predicted to provide little to no power gain from LRF under real world conditions. Based on these results, modules with LRF on tabbing ribbons would have to be mounted in “landscape” mode to realize a performance advantage. In addition, modeling showed that under diffuse lighting conditions such as when the sky is overcast, there would be no significant performance advantage for modules with LRF. Modules were sent to an outside contractor to measure the power performance under different angles of incident light in order to validate the modeling results. The measured data agreed very well with the modeling predictions and showed that the power gain for modules with LRF applied to tabbing ribbons was completely lost at an angle of 25 degrees off of perpendicular. At even larger angles, the power was lower than standard modules. From 35 degrees to 55 degrees off axis, the power loss was about 1.4% or equal to the power gain at the optimum condition of perfectly on-axis light.

14 SOLAR ENERGY↗

Closure Device For a Containment Vessel in a Small Gram Quantity Shipping Package

SRNL has been chartered by DOE Environmental Management (DOE-EM) to develop a new Type B shipping package for Small Gram Quantities (SGQ) of radioactive material. Design a containment vessel (CV) closure device that will reduce the operation time and improve the ease-of- use for Operations Personnel. The Containment Vessel (CV) includes a closure lid cap with spring shaft and locking tabs, multiple disc springs, and vessel with integral locking ring. The CV is assembled by aligning the tabs on the lid cap with the openings in the locking ring. Next, the lid cap is pushed down to compress the disc springs. Finally, the lid is rotated 45-degrees to locking location. When released, the tabs are secured against the locking ring. Disc springs (e.g. Belleville washers, coned-disc springs, Belleville spring, etc.) exert axial loads on the mating parts when compressed. The orientation of the disc springs can be configured to change the deflection and axial loads for specific designs. In addition to securing the lid cap to the vessel, the compressed disc springs can be used to apply a load to a containment seal (e.g. o-ring). A prototype of the CV closure was 3D printed to evaluate the locking mechanism design and functionality. A test plan will be developed to evaluate the mechanical properties (i.e. compression forces) and functionality of the CV closure design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Criticality Analysis of FSV Spent Nuclear Fuel in the DOE Standard Canister

The U.S. Department of Energy (DOE) is responsible for managing over 300 types of spent nuclear fuel (SNF). To manage this large variety of fuel types, DOE plans to employ standardized canisters for the transportation, long-term storage, and eventual disposal of SNF. Idaho National Laboratory is currently supporting DOE’s SNF Packaging Demonstration Project, in which Fort Saint Vrain (FSV) fuel assemblies will be loaded into a DOE Standard Canister. This paper presents criticality calculations demonstrating that all four or five FSV fuel assemblies loaded into the DOE Standard Canister will remain subcritical in any expected normal or credible abnormal conditions. Previous criticality analyses were performed for one FSV fuel assembly and 12 Peach Bottom Core 2 fuel elements loaded into a DOE Standard Canister. This paper covers the criticality analysis performed for loading both four and five FSV fuel assemblies into a DOE Standard Canister. Various intact and degraded mode configurations were modeled in conducting the criticality calculations. This analysis encompassed three different configurations: (1) a single DOE Standard Canister loaded into a concrete storage overpack, (2) seven DOE Standard Canisters loaded into a concrete storage overpack, and (3) nine DOE Standard Canisters loaded into a concrete storage overpack. The overpack dimensions were varied for each of the three configurations, and transport, storage, and disposal scenarios were analyzed for each configuration. For transport scenarios, a pair of degradation cases was analyzed. In the first case, the fuel compacts became degraded and were removed from the fuel block, then deposited at the bottom of a horizontally placed canister, thereby simulating a drop event. The canister was considered to remain intact. In the second case, the spacing between horizontally placed canisters in a nine-canister overpack was reduced such that the canisters were piled on top of each other, simulating a drop event. For this case, no degradation of the canister internals or fuel was considered. For storage scenarios, the water moderator location in the system was varied to enable identification of the most reactive configurations. Dry and wet conditions were analyzed for the fuel materials, canister, and overpack. For disposal scenarios, two degradation cases were analyzed. In the first, the stainless-steel internals of the canister degraded to either hematite or goethite under both dry and wet conditions. In the second case, degraded FSV fuel formed a uranium-water slurry that filled the coolant/void holes. None of the cases presented exceeded the application specific upper subcritical limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic parameter estimation of generators

Various examples are provided for parameter estimation of generators. In one example, among others, a method includes collecting data corresponding to a generator using a phasor management unit (PMU) and estimating dynamic parameters of the generator using extended Kalman filtering (EKF) and the collected PMU data. In another example, a system includes at least one application executable in a processing device that obtains operational data corresponding to a generator and estimates a dynamic parameter of the generator using EKF and the operational data. In another example, an EKF estimator includes a dynamics estimator configured to estimate a state variable of a generator, a geometry estimator configured to estimate phasor values associated with the generator, and a Kalman filter gain configured to determine a correction to the state variable.

Miao, Zhixin↗

A Comparison of As-loaded Dose Calculations to Measured Dose Rates

Demonstrating that the radiation dose fields surrounding spent nuclear fuel (SNF) storage and transportation systems meet the applicable limits set forth in 10 CFR 72 for storage and 10 CFR 71 for transportation is essential for the safe handling of radioactive material. The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST&DARDS) [2] is used to provide realistic estimates of SNF-related safety margins. The UNF-ST&DARDS dose rate analysis approach differs from that used in typical licensing approaches, which use design-basis assemblies with bounding source term characteristics to demonstrate the packaging design complies with the regulations. These bounding licensing approaches can increase the time needed to qualify fuel for loading into dry storage and the time a loaded system must wait prior to transportation. UNF-ST&DARDS dose rate assessments allow quantification of realistic, uncredited safety margins associated with actual fuel loading compared with the regulatory limits. While realistic estimation of the dose field surrounding SNF systems may allow for additional flexibility in operations, it is essential to understand how these predictions compare to measured doses. The U.S. Department of Energy Office of Integrated Waste Management and the Prairie Island Indian Community conducted a transportation dose assessment to estimate the site-specific incident-free radiation doses from shipping SNF by rail from the Prairie Island Nuclear Generating Plant (PINGP) through the Prairie Island Indian Community Reservation and Trust Land [5,6]. For that effort, the dose rates were obtained for 50 TN-40 and TN-40HT systems in storage configurations. This work compares the predicted dose rates from UNF-ST&DARDS as-loaded calculations with dose rates measured from 50 SNF storage systems at PINGP. The remainder of this paper discusses the data obtained for the evaluation, the modeling methods, and the results of the calculations.

spent nuclear fuel (SNF), UNF-ST&DARDS, Validation↗

Near isothermal compressed air energy storage system in residential and commercial buildings: Techno-economic analysis

Electrical energy storage systems offer a wide range of options to efficiently manage our power supply infrastructure. Energy and environmental security via renewable resources and energy storage devices will also play a critical role in addressing the supply-demand challenges. A novel energy efficient storage system based on near isothermal compressed air energy storage concept, named as Ground-Level Integrated Diverse Energy Storage (GLIDES) is analyzed for integration with residential and commercial buildings. Additionally, the influence of different configurational aspects on key performance and cost attributes is presented in this study. GLIDES modules in the range of 0.5 kWh–15 kWh configurations were considered for residential buildings whereas 25 kW h–500 kW h modules were considered for commercial buildings. Detailed cost and performance analysis of the GLIDES module proved them to be an effective resource in lowering the peak energy demand and corresponding utility bills.

25 ENERGY STORAGE↗

Autonomous management of a recursive area hierarchy for large scale wireless sensor networks using multiple parents

Large scale wireless sensor networks have been proposed for applications ranging from anomaly detection in an environment to vehicle tracking. Many of these applications require the networks to be distributed across a large geographic area while supporting three to five year network lifetimes. In order to support these requirements large scale wireless sensor networks of duty-cycled devices need a method of efficient and effective autonomous configuration/maintenance. This method should gracefully handle the synchronization tasks duty-cycled networks. Further, an effective configuration solution needs to recognize that in-network data aggregation and analysis presents significant benefits to wireless sensor network and should configure the network in a way such that said higher level functions benefit from the logically imposed structure. NOA, the proposed configuration and maintenance protocol, provides a multi-parent hierarchical logical structure for the network that reduces the synchronization workload. It also provides higher level functions with significant inherent benefits such as but not limited to: removing network divisions that are created by single-parent hierarchies, guarantees for when data will be compared in the hierarchy, and redundancies for communication as well as in-network data aggregation/analysis/storage.

47 OTHER INSTRUMENTATION↗

Performance Assessment for the Waste Management Area C at the Hanford Site in Southeast Washington - 17515

An initial performance assessment (PA) of Single-Shell Tank (SST) Waste Management Area C (WMA C) located at the U.S. Department of Energy's (DOE) Hanford Site in southeastern Washington has been completed to satisfy the requirements of the Hanford Federal Facility Agreement and Consent Order (HFFACO), as well as other Federal requirements and State-approved closure plans and permits. The WMA C PA assesses the fate, transport, and impacts of radionuclides within residual wastes left in tanks and ancillary equipment and facilities in their assumed closed configuration, and the subsequent risks to humans into the far future. This PA focused on radiological impacts has been developed to meet the requirements for a closure authorization under DOE O 435.1 that includes a waste incidental to reprocessing determination for residual wastes remaining in tanks, ancillary equipment, and facilities. PA results indicate that the performance objectives and measures for the all-pathways dose, the air pathway dose, the radon flux, and groundwater protection are met for both the 1,000-year compliance time period (2020 to 3020) and the post-compliance period (3020 to 12020). The peak dose for the all-pathways analysis in the 1,000-year compliance period is associated with the air pathway, with the peak dose of 4 x 10{sup -5} mSv/yr dominated by tritium resulting from upward gaseous diffusive flux from the residual waste. The peak dose within the sensitivity/uncertainty analysis time period (1,000 to 10,000 years after closure) occurs at about 1,500 years after closure, and results primarily from a peak in {sup 99}Tc groundwater concentration at 100 m down-gradient of the facility. The peak total dose within the sensitivity/uncertainty analysis time period is 0.001 mSv/yr. For all of the sensitivity analyses and uncertainty analyses evaluated, the disposal system also met the performance objectives. In the uncertainty analysis performed with the system level model based on GoldSim{sup C}, the highest calculated groundwater dose in the compliance period was about 7 x 10{sup -4} mSv/yr, and the highest calculated peak dose in the sensitivity/uncertainty analysis period was 0.025 mSv/yr.Doses associated with hypothetical inadvertent human intrusion were calculated for all sources in WMA C and compared to the acute and chronic performance measures in DOE O 435.1. The calculated doses for acute and chronic exposure scenario from potential intrusion into a waste transfer pipeline remain below the DOE O 435.1 performance measure for the time period evaluated beyond 100 years after closure. Acute exposure from drilling into the waste yielded a dose of about 0.36 mSv after the assumed 100-year institutional control period, well below the 5 mSv performance measure for acute exposure. Chronic exposure to waste from drill cuttings in a rural pasture scenario resulted in a dose of about 0.08 mSv/yr after the assumed 100-year institutional control period, well below the 1 mSv/yr performance measure for chronic exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal design analysis for SuperTruck II lithium-titanate battery pack

Here, this paper presents a systematic thermal management analysis for a new lithium-titanate-oxide battery pack to be installed in a SuperTruck II, Class 8 hybrid truck. The authors investigate the feasibility of mounting the battery pack inside the vehicle and air-cooling it with fans supplying conditioned air from the cabin. Moreover, the cells within each module are to be immersed in a heat-transfer fluid to improve temperature homogeneity. A multi-stage thermal analysis is performed to ensure adequate thermal regulation of the battery under the proposed design, considering installation and operational constraints. The authors perform thermal and electrical characterization tests on a single cell. Results inform the development of computational fluid dynamics models of the cells, modules, and pack. Module-level analysis shows that the cell temperatures can be maintained below their upper operational limit of 55 °C with module wall-to-air heat transfer coefficients between 10 and 20 Wm -2 K -1 . Pack-level analysis of distinct configurations determines effective airflow paths for adequate heat transfer and delivers a final battery pack design that achieves sufficient cooling and temperature uniformity. A reduced-order electrothermal model is developed to rapidly predict the transient battery performance and to develop a temperature control strategy.

25 ENERGY STORAGE↗

Development of a Conditioned System-Level Groundwater Model to Evaluate Long-Term Groundwater Impacts within a Performance Assessment - 20115

A preliminary performance assessment (PA) of single-shell tank Waste Management Area (WMA) A-AX located at the U.S. Department of Energy (DOE)'s Hanford Site in southeastern Washington is being conducted to satisfy the requirements of DOE Order 435.1 [1] as it relates to closure of the single-shell radioactive waste tanks in the WMA A-AX tank farms. A PA assesses the fate, transport, and impacts of radionuclides within a low-level radioactive waste disposal facility in its assumed closure configuration and the subsequent potential doses to humans over a 1,000-year compliance period and a 10,000-year performance evaluation period. The WMA A-AX preliminary PA evaluation is structured around the complementary use of process-level and system-level models to calculate the facility performance against established DOE Order 435.1 [1] performance objectives. Process-level models are those that represent a detailed phenomenological representation of processes of concern in the PA. Process models typically only represent one or a few of the components of the PA, such as groundwater flow and transport, and must be integrated with other modeling elements to perform PA calculations. System-level models are those that are abstracted from the process models, retaining the essential features of the process model, while allowing integration of all aspects of the PA in a single modeling framework. System-level models are often characterized by coarser numerical discretization, lower dimensionality, or other similar simplifications compared to the process-level model. Traditionally, a three-dimensional (3-D) process-level model is utilized primarily to evaluate the long-term impact on groundwater and the potential doses to individuals who consume contaminated groundwater. System-level models are also utilized to evaluate the groundwater pathway in PAs. These models typically have reduced dimensionality (1-D) and are conditioned utilizing flow fields (Darcy fluxes) and moisture content distributions that are abstracted from the process level models. The abstraction approach assures that the flow field in both models is consistent for a specific set of input parameters for flow, differing only in the discretization and dimensionality of the two models. The preliminary WMA A-AX PA incorporates a detailed representation of the geological system and hydraulic properties within the 3-D model STOMP{sup C} numerical code so that the effects of relevant features and processes on water flow and radionuclide transport in the subsurface can be evaluated. The complementary system-level model is developed utilizing the GoldSim{sup C} code to implement a simplified, 1-D equivalent model to represent the groundwater pathway. Contaminant transport through the vadose zone and unconfined aquifer for Tc-99 and I-129 were evaluated in each of the models. Adjustments to the saturated portion of the GoldSim{sup C} 1-D model were required to mimic the dispersion effect captured with the 3-D STOMP{sup C} model. Once this conditioning was conducted, highly similar results for the transport of Tc-99 and I-129 were achieved at the point of calculation, located 100 m downgradient from the WMA A-AX fenceline. These radionuclides represent elements that are regarded as primary dose drivers in the PA groundwater pathway analysis. The high degree of conformance between the two models suggests that the use of the equivalent 1-D system model is suitable for evaluating the full suite of radionuclides that will be released from the tank sources within WMA A-AX over the 1,000-year compliance period and over the 10,000-year evaluation period. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chapter 6: Luminescence and Thermal Imaging of Thin-Film Photovoltaic Materials, Devices, and Modules

In this chapter, we describe luminescence and thermal imaging in the context of thin-film PV devices. First, we discuss both traditional and developing experimental designs, including dark LIT (DLIT), illuminated LIT, PL using different illumination configurations, traditional EL performed under forward -bias current injection, and contactless EL induced with sub -cell illumination patterns. Next, we provide some brief theoretical background to highlight relationships between fundamental materials properties and the resulting luminescence and thermal images. Finally, we give examples of thin-film PV PL, EL, and LIT images to demonstrate the utility of these imaging methods ranging from understanding the microstructure of active layers to managing the quality and reliability of full PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗