Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Artificial-intelligence-based prediction and control of combustion instabilities in spark-ignition engines

In recent years, as engine control strategies have grown increasingly sophisticated in a continued drive for increasing efficiency and reducing emissions, engine operation has been pushed into regimes that are limited by combustion instabilities. These instabilities produce undesirable abnormal combustion events, which pose barriers to further improvement in engine efficiency. Many of the phenomena involved are difficult to model or control using traditional, purely physics-based models and reactive control approaches. Artificial intelligence (AI) techniques offer some promise for achieving more effective combustion stability control, especially when appropriately applied within a physics-informed framework. This chapter illustrates the current state-of-the-art in applying AI to combustion stability control and examines three case studies with application to the dilute stability limit in spark-ignition engines to illustrate the utility and limitations of AI in these applications.

Maldonado Puente, Bryan↗

Proof-of-Concept for Sensor Modeling in MOOSE for the Design of Autonomous Nuclear Reactor Control

Autonomous operation is essential for the deployment of microreactors and fission batteries, both in terrestrial and space applications. For this reason, recent studies have investigated autonomous control by using adaptive model predictive control and multi-objective optimization for heat pipe–cooled microreactors under normal and heat pipe failure conditions. However, prototypes of microreactors and fission batteries do not exist yet, and even the design space has not been narrowed down conclusively, making the instrumentation and control system design difficult. For this reason, there is a need for flexible computational capabilities to create a numerical stand-in of potential microreactor and fission battery designs. The latter can be used to design and test control strategies to support autonomous operations. In this poster, we describe the initial implementation of a pluggable sensor system for the easy implementation of realistic sensor models in the multiphysics object-oriented simulation environment (MOOSE) framework. This new capability will enable MOOSE users to create a numerical stand-in of microreactors and fission batteries, ultimately allowing them to easily test new control algorithms, and instrumentation strategies for advanced systems in the design phase.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A centralized-based method to determine the local voltage control strategies of distributed generator operation in active distribution networks

The increasing penetration of distributed generators (DGs) exacerbates the risk of voltage violations in active distribution networks (ADNs). The var capacity provided by DG inverters is a potential solution for voltage regulation. The conventional centralized control strategies limited by computation and communication burdens are difficult to meet the requirement of rapid voltage control. However, the local control strategies based on real-time measurements have a fast response to the frequent fluctuations of DG outputs. The performance of these local controllers depends on the tuning of the control parameters. This paper proposes a centralized-based method to determine the local voltage control strategies for DGs. A centralized parameter tuning model of control curves is built, in which and curves of DG inverters are mathematically formulated based on piecewise linearization. The original mixed-integer nonlinear programming (MINLP) model is converted into an effectively solved mixed-integer second-order cone programming (MISOCP) model using convex relaxation. The potential benefits of DG inverters are explored to regulate both reactive and curtailed active power, based on local voltage measurements. Case studies on a modified PG&E 69-node distribution system are carried out to verify the effectiveness of the proposed method. Results show that power losses of ADNs are significantly reduced and voltage profiles are also improved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NO x adsorption with CO and C 2 H 4 on Pd/SSZ-13: Experiments and modeling

A transient monolith model containing microkinetic schemes for NO uptake and release over Pd/SSZ-13 without and with reductants CO or C2H4 is presented. The scheme involves three cationic Pd species (Z – [PdOH] + , Z – Pd 2+ Z – , Z – Pd + ) as the active sites during uptake of NO, CO and C 2 H 4 , and their desorption and conversion at higher temperature. Kinetic parameters are estimated through a combination of density functional theory (DFT) estimates and a fit of uptake, desorption and conversion data. The tuned model is validated at different uptake temperatures, ramp rates, and flowrates. A “degree of uptake control” parameter is defined that helps to identify the step(s) that are uptake controlling. The model helps to interpret the data features and is used to identify operating conditions to meet application-relevant performance metrics, including NO trapping efficiency and NO release temperature. Furthermore, the model demonstrates higher NO uptake on Pd/SSZ-13 compared to Pd/ZSM-5.

42 ENGINEERING↗

Bilayer Thickness Mismatch Controls Domain Size in Model Membranes

The observation of lateral phase separation in lipid bilayers has received considerable attention, especially in connection to lipid raft phenomena in cells. It is widely accepted that rafts play a central role in cellular processes, notably signal transduction. While micrometer-sized domains are observed with some model membrane mixtures, rafts much smaller than 100 nm beyond the reach of optical microscopy are now thought to exist, both in vitro and in vivo. We have used small-angle neutron scattering, a probe free technique, to measure the size of nanoscopic membrane domains in unilamellar vesicles with unprecedented accuracy. These experiments were performed using a four-component model system containing fixed proportions of cholesterol and the saturated phospholipid 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), mixed with varying amounts of the unsaturated phospholipids 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) and 1,2-dioleoylsn- glycero-3-phosphocholine (DOPC). We find that liquid domain size increases with the extent of acyl chain unsaturation (DOPC:POPC ratio). Furthermore, we find a direct correlation between domain size and the mismatch in bilayer thickness of the coexisting liquid-ordered and liquid-disordered phases, suggesting a dominant role for line tension in controlling domain size. While this result is expected from line tension theories, we provide the first experimental verification in free-floating bilayers. Importantly, we also find that changes in bilayer thickness, which accompany changes in the degree of lipid chain unsaturation, are entirely confined to the disordered phase. Together, these results suggest how the size of functional domains in homeothermic cells may be regulated through changes in lipid composition.

Heberle, Frederick A↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of abatement potentials and costs of air pollution emissions in China

Understanding the air pollution emission abatement potential and associated control cost is a prerequisite to design cost ef?cient control policies. In this study, a linear programming algorithm model, International Control Cost Estimate Tool, was updated with cost data for applications of 56 types of end-of-pipe technologies and ?ve types of renewable energy in 10 major sectors namely power generation, industry combustion, cement pro-duction, iron and steel production, other industry processes, domestic combustion, transportation, solvent use, livestock rearing, and fertilizer use. The updated model was implemented to estimate the abatement potential and marginal cost of multiple pollutants in China. The total maximum abatement potentials of sulfur dioxide (SO2), nitrogen oxides (NOx), primary particulate matter (PM2.5), non-volatile organic compounds (NMVOCs), and ammonia (NH3) in China were estimated to be 19.2, 20.8, 9.1, 17.2 and 8.6 Mt, respectively, which accounted for 89.7%, 89.9%, 94.6%, 74.0%, and 80.2% of their total emissions in 2014, respectively. The associated control cost of such reductions was estimated as 92.5, 469.7, 75.7, 449.0, and 361.8 billion CNY in SO2, NOx, primary PM2.5, NMVOCs and NH3, respectively. Shandong, Jiangsu, Henan, Zhejiang, and Guangdong provinces exhibited large abatement potentials for all pollutants. Provincial disparity analysis shows that high GDP regions tend to have higher reduction potential and total abatement costs. End-of-pipe technologies tended be a cost-ef?cient way to control pollution in industries processes (i.e., cement plants, iron and steel plants, lime production, building ceramic production, glass and brick production), whereas such technologies were less cost- effective in fossil fuel-related sectors (i.e., power plants, industry combustion, domestic combustion, and transportation) compared with renewable energy. The abatement potentials and marginal abatement cost curves developed in this study can further be used as a crucial component in an integrated model to design optimized cost-ef?cient control policies.

Zhang, Fenfen↗

SELF-CONSISTENT MODEL OF THE INTERSTELLAR PICKUP PROTONS, ALFVENIC TURBULENCE, AND CORE SOLAR WIND IN THE OUTER HELIOSPHERE

A self-consistent model of the interstellar pickup protons, the slab component of the Alfvenic turbulence, and core solar wind (SW) protons is presented for r {>=} 1 along with the initial results of and comparison with the Voyager 2 (V2) observations. Two kinetic equations are used for the pickup proton distribution and Alfvenic power spectral density, and a third equation governs SW temperature including source due to the Alfven wave energy dissipation. A fraction of the pickup proton free energy, f{sub D} , which is actually released in the waveform during isotropization, is taken from the quasi-linear consideration without preexisting turbulence, whereas we use observations to specify the strength of the large-scale driving, C{sub sh}, for turbulence. The main conclusions of our study can be summarized as follows. (1) For C{sub sh} Almost-Equal-To 1-1.5 and f{sub D} Almost-Equal-To 0.7-1, the model slab component agrees well with the V2 observations of the total transverse magnetic fluctuations starting from {approx}8 AU. This indicates that the slab component at low-latitudes makes up a majority of the transverse magnetic fluctuations beyond 8-10 AU. (2) The model core SW temperature agrees well with the V2 observations for r {approx}> 20 AU if f{sub D} Almost-Equal-To 0.7-1. (3) A combined effect of the Wentzel-Kramers-Brillouin attenuation, large-scale driving, and pickup proton generated waves results in the energy sink in the region r {approx}< 10 AU, while wave energy is pumped in the turbulence beyond 10 AU. Without energy pumping, the nonlinear energy cascade is suppressed for r {approx}< 10 AU, supplying only a small energy fraction into the k-region of dissipation by the core SW protons. A similar situation takes place for the two-dimensional turbulence. (4) The energy source due to the resonant Alfven wave damping by the core SW protons is small at heliocentric distances r {approx}< 10 AU for both the slab and the two-dimensional turbulent components. As a result, adiabatic cooling mostly controls the model SW temperature in this region, and the model temperature disagrees with the V2 observations in the region r {approx}< 20 AU.

79 ASTRONOMY AND ASTROPHYSICS↗

Model-based data center cooling controls comparative co-design

This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter

This paper presents a sensor-less current model predictive control (MPC) scheme via a full state observer based current estimator. The grid interactive inverters’ control schemes require current and voltage sensors. Elimination of current sensor enhances the inverter reliability. This paper leverages the inherent characteristics of MPC towards robust current sensor-less grid interactive inverter with LC filter. The observer for inductor current is developed based on the existing capacitor voltage measurement. The estimator dynamic state-space matrices are then obtained through reconstruction of the inverter model with the capacitor voltage and inductor current being the state variables. The controller objectives are to regulate active and reactive power in a decoupled manner. The theoretical expectation, controller performance, and accuracy of the current estimation are verified by conducting a real-time simulation via Typhoon HIL.

Zhang, Zhen↗

Current profile and normalized beta control via feedback linearization and Lyapunov techniques

Abstract Simultaneous control of the current profile and normalized plasma beta is an essential control problem in the development of advanced tokamak scenarios. However, this control problem is especially challenging due to the nonlinear nature of the current, heat, and particle transport dynamics, as well as the difficulty to understand and accurately model such processes. In this work, a nonlinear, robust, model-based controller for the simultaneous regulation of the current profile and normalized beta has been designed using feedback linearization and Lyapunov redesign techniques. Feedback linearization avoids approximate linearization of the plasma dynamics, retaining the original physics content of the model. Moreover, the use of Lyapunov redesign techniques makes the controller robust against the uncertainties arising during the modeling process. The controller’s performance in the presence of unknown dynamics is tested in nonlinear, one-dimensional simulations using the Control Oriented Transport SIMulator (COTSIM) code, which employs plasma models that are significantly more complex than those employed for control synthesis.

Physics↗

Optimal Power Flow for Distribution Systems under Uncertain Forecasts

The paper focuses on distribution systems featuring renewable energy sources and energy storage devices, and develops an optimal power flow (OPF) approach to optimize the system operation in spite of forecasting errors. The proposed method builds on a chance-constrained multi-period AC OPF formulation, where probabilistic constraints are utilized to enforce voltage regulation with a prescribed probability. To enable a computationally affordable solution approach, a convex reformulation of the OPF task is obtained by resorting to i) pertinent linear approximations of the power flow equations, and ii) convex approximations of the chance constraints. Particularly, the approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive optimization strategy is then obtained by embedding the proposed OPF task into a model predictive control framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic simulation and techno-economic analysis of a concentrated solar power (CSP) plant hybridized with both thermal energy storage and natural gas

The addition of thermal energy storage and natural gas as a complementary energy source improves the flexibility, reliability, and value of concentrated solar power (CSP) plants. Nevertheless, due to the transient nature of solar energy, transitions from solar-only mode and natural-gas mode to hybrid solar-natural gas mode is quite challenging, especially when the plant is equipped with thermal storage. Thus, it is important to develop proper dynamic modeling and control schemes to accurately simulate such transitions. The objective of this study is to address this subject by demonstrating a dynamic model with reliable control schemes for a highly integrated hybrid parabolic trough-natural gas plant equipped with thermal energy storage. The specific goal is to study the dynamics of adding thermal storage to the hybrid plant. It is found that the developed control schemes assist smooth transitions between different operational modes and effective utilization of thermal storage and natural gas to maintain steady power production and steam mass flow rates under different solar conditions. The results demonstrate that the integration of storage regulates power production by solar energy and natural gas during the day time. It also enables an increase in the solar fraction of the hybrid plant while it causes a small decrease in thermodynamic efficiency. The analysis shows that the hybrid plant with the storage has a substantially lower specific CO 2 emission (0.320 tonne/MWh) than single natural gas plant (0.413 tonne/MWh) although it has a higher levelized cost of electricity (86.32/MWh against 74.92/MWh). The hybrid plant with storage demonstrates a promising potential for reliable and clean production of electricity, although research and development should be conducted to lower its cost.

03 NATURAL GAS↗

A high-fidelity building performance simulation test bed for the development and evaluation of advanced controls

We present an open-source building performance simulation test bed, the Advanced Controls Test Bed (ACTB), that interfaces high-fidelity Spawn of EnergyPlus building models, with advanced controllers implemented in Python. Additionally, the ACTB leverages the Building Optimization Testing and Alfalfa platforms for managing simulations, providing an external clock, a representational state transfer (REST) application programming interface (API), and key performance indicators for evaluating the effectiveness of control strategies. The REST API allows the development of external controllers programmed in languages such as Python, which provides flexibility and a rich choice of scientific libraries for designing control sequences. We present three test cases based on the U.S. Department of Energy's Reference Small Office Building to demonstrate the ACTB's capabilities: (a) rule-based controls compliant with ASHRAE Guideline 36 control sequences; (b) an economic model predictive control implemented using do-mpc; and (c) a deep Q-network reinforcement learning agent implemented using OpenAI Gym.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ActiveBAS: A Low-cost, Scalable Control Solution for Grid-Interactive Small and Medium Sized Commercial Buildings

This project aims to develop and enhance a low-cost, highly scalable control solution for Small and Medium-Sized Commercial Buildings (SMCB), assess the business potential at multiple sites, and perform commercialization efforts. The technology can be applied to any buildings served by multiple units, with the benefits being greatest for open-spaced buildings, such as banks, retail stores, restaurants, and factories. This project aims to develop an affordable control solution for: 1) SMCB grid responsiveness, 2) reduction of GHG by changing unit operations, 3) greater reduction in utility costs, and 4) rapid adoption in the marketplace. The proposed technology will be built on a previously developed and demonstrated MPC solution. The minimal sensor requirement and less need of control expertise are the unique feature of the algorithm that leads to low capital and maintenance costs, and short installation and implementation time. These attributes contribute to low capital and maintenance costs, as well as a short installation and implementation time. However, these advantages come with a trade-off: increased difficulties and unreliability when applying traditional modeling and MPC control approaches due to limited information. This final report describes the modeling approaches developed and tested to overcome these challenges. It begins by outlining the modeling challenge posed by minimal sensor requirements, then delves into the proposed modeling approaches, which primarily involve system identification. Finally, preliminary test results for a simulation case study are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multifidelity Ensemble Kalman Filter with Reduced Order Control Variates

This work develops a new multi delity ensemble Kalman lter (MFEnKF) algorithm based on linear control variate framework. The approach allows for rigorous multi delity extensions of the EnKF, where the uncertainty in coarser delities in the hierarchy of models represent control variates for the uncertainty in ner delities. Small ensembles of high delity model runs are com- plemented by larger ensembles of cheaper, lower delity runs, to obtain much improved analyses at only small additional computational costs. We investigate the use of reduced order models as coarse delity control variates in the MFEnKF, and provide analyses to quantify the improvements over the traditional ensemble Kalman lters. We apply these ideas to perform data assimilation with a quasi-geostrophic test problem, using direct numerical simulation and a corresponding POD-Galerkin reduced order model. Numerical results show that the two- delity MFEnKF provides better analyses than existing EnKF algorithms at comparable or reduced computational costs.

97 MATHEMATICS AND COMPUTING↗

A Modelica-based Model Library for Building Energy and Control Systems

This paper describes an open-source library with component models for building energy and control systems that is based on Modelica, an equation-based objectoriented language that is well positioned to become the standard for modeling of dynamic systems in various industrial sectors. The library is currently developed to support computational science and engineering for innovative building energy and control systems. Early applications will include controls design and analysis, rapid prototyping to support innovation of new building systems and the use of models during operation for controls, fault detection and diagnostics. This paper discusses the motivation for selecting an equation-based object-oriented language. It presents the architecture of the library and explains how base models can be used to rapidly implement new models. To demonstrate the capability of analyzing novel energy and control systems, the paper closes with an example where we compare the dynamic performance of a conventional hydronic heating system with thermostatic radiator valves to an innovative heating system. In the new system, instead of a centralized circulation pump, each of the 18 radiators has a pump whose speed is controlled using a room temperature feedback loop, and the temperature of the boiler is controlled based on the speed of the radiator pump. All flows are computed by solving for the pressure distribution in the piping network, and the controls include continuous and discrete time controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗