Search NASA⌕ Search

SEARCH · Search NASA

Results for “Correlation analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Comparison of Likelihood Methods for Generalized Linear Mixed Models with Application to Quiet Supersonic Flights 2018 Data

Repeated measurement will be a feature of the survey data collected during the Quesst missionX-59 community response tests (CRT). Since each participant will report his or her categorical level of annoyance in response to multiple events, the responses from any single individual may be correlated with one another. Several models within the class of generalized linear mixed models (GLMM) are pertinent to the analysis of correlated categorical outcomes; the random intercept logistic regression model is one example. Both Bayesian and frequentist methods for fitting these models are available, with frequentist methods relying on some form of approximation (of either an integral or the integrand) that appears in the marginal likelihood function. Given several anticipated similarities of the X-59 CRT data to data collected during a past risk reduction, Quiet Supersonic Flights 2018 (QSF18), this short note is intended to create awareness. It documents an instance in which a reported population average dose-response relationship derived from QSF18 single event data was distorted by the integral approximation applied in likelihood-based methods. We review some of the available literature on the topic, compare the outputs of several different computational approaches implemented in available statistical software, and present simple corrective actions that may be useful during the Quesst mission.

dose-response model↗

Pion femtoscopy in p+p collisions at sqrt s= 200 GeV

The STAR Collaboration at the BNL Relativistic Heavy Ion Collider has measured two-pion correlation functions from p+p collisions at {radical}s = 200 GeV. Spatial scales are extracted via a femtoscopic analysis of the correlations, though this analysis is complicated by the presence of strong nonfemtoscopic effects. Our results are put into the context of the world data set of femtoscopy in hadron-hadron collisions. We present the first direct comparison of femtoscopy in p+p and heavy ion collisions, under identical analysis and detector conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial Correlation Function of the Chandra Selected Active Galactic Nuclei

We present the spatial correlation function analysis of non-stellar X-ray point sources in the Chandra Large Area Synoptic X-ray Survey of Lockman Hole Northwest (CLASXS). Our 9 ACIS-I fields cover a contiguous solid angle of 0.4 deg(exp 2) and reach a depth of 3 x 10(exp -15) erg/square cm/s in the 2-8 keV band. We supplement our analysis with data from the Chandra Deep Field North (CDFN). The addition of this field allows better probe of the correlation function at small scales. A total of 233 and 252 sources with spectroscopic information are used in the study of the CLASXS and CDFN fields respectively. We calculate both redshift-space and projected correlation functions in co-moving coordinates, averaged over the redshift range of 0.1 < z < 3.0, for both CLASXS and CDFN fields for a standard cosmology with Omega(sub Lambda) = 0.73,Omega(sub M) = 0.27, and h = 0.71 (H(sub 0) = 100h km/s Mpc(exp -1). The correlation function for the CLASXS field over scales of 3 Mpc< s < 200 Mpc can be modeled as a power-law of the form xi(s) = (S/SO)(exp - gamma), with gamma = 1.6(sup +0.4 sub -0.3) and S(sub o) = 8.0(sup +.14 sub -1.5) Mpc. The redshift-space correlation function for CDFN on scales of 1 Mpc< s < 100 Mpc is found to have a similar correlation length so = 8.55(sup +0.74 sub -0.74) Mpc, but a shallower slope (gamma = 1.3 +/- 0.1). The real-space correlation functions derived from the projected correlation functions, are found to be tau(sub 0 = 8.1(sup +1.2 sub -2.2) Mpc, and gamma = 2.1 +/- 0.5 for the CLASXS field, and tau(sub 0) = 5.8(sup +.1.0 sub -1.5) Mpc, gamma = 1.38(sup +0.12 sub -0.14 for the CDFN field. By comparing the real- and redshift-space correlation functions in the combined CLASXS and CDFN samples, we are able to estimate the redshift distortion parameter Beta = 0.4 +/- 0.2 at an effective redshift z = 0.94. We compare the correlation functions for hard and soft spectra sources in the CLASXS field and find no significant difference between the two groups. We have also found that the correlation between X-ray luminosity and clustering amplitude is weak, which, however, is fully consistent with the expectation using the simplest relations between X-ray luminosity, black hole mass, and dark halo mass. We study the evolution of the AGN clustering by dividing the samples into 4 redshift bins over 0.1 Mpc< z <3.0 Mpc. We find a very mild evolution in the clustering amplitude, which show the same evolution trend found in optically selected quasars in the 2dF survey. We estimate the evolution of the bias, and find that the bias increases rapidly with redshift (b(z = 0.45) = 0.95 +/- 0.15 and b(z = 2.07) = 3.03 +/- 0.83): The typical mass of the dark matter halo derived from the bias estimates show little change with redshift. The average halo mass is found to be log (M(sub halo)/M(sun))approximates 12.1. Subject headings: cosmology: observations - large-scale structure of the universe - x-rays: diffuse background - galaxies: nuclei

Yang, Y.↗

WE-H-BRA-08: A Monte Carlo Cell Nucleus Model for Assessing Cell Survival Probability Based On Particle Track Structure Analysis

Purpose: To correlate the damage produced by particles of different types and qualities to cell survival on the basis of nanodosimetric analysis and advanced DNA structures in the cell nucleus. Methods: A Monte Carlo code was developed to simulate subnuclear DNA chromatin fibers (CFs) of 30nm utilizing a mean-free-path approach common to radiation transport. The cell nucleus was modeled as a spherical region containing 6000 chromatin-dense domains (CDs) of 400nm diameter, with additional CFs modeled in a sparser interchromatin region. The Geant4-DNA code was utilized to produce a particle track database representing various particles at different energies and dose quantities. These tracks were used to stochastically position the DNA structures based on their mean free path to interaction with CFs. Excitation and ionization events intersecting CFs were analyzed using the DBSCAN clustering algorithm for assessment of the likelihood of producing DSBs. Simulated DSBs were then assessed based on their proximity to one another for a probability of inducing cell death. Results: Variations in energy deposition to chromatin fibers match expectations based on differences in particle track structure. The quality of damage to CFs based on different particle types indicate more severe damage by high-LET radiation than low-LET radiation of identical particles. In addition, the model indicates more severe damage by protons than of alpha particles of same LET, which is consistent with differences in their track structure. Cell survival curves have been produced showing the L-Q behavior of sparsely ionizing radiation. Conclusion: Initial results indicate the feasibility of producing cell survival curves based on the Monte Carlo cell nucleus method. Accurate correlation between simulated DNA damage to cell survival on the basis of nanodosimetric analysis can provide insight into the biological responses to various radiation types. Current efforts are directed at producing cell survival curves for high-LET radiation.

60 APPLIED LIFE SCIENCES↗

The lunar swirls - Distribution and possible origins

Correlative data analysis and theoretical modeling methods are used to evaluate models involving both meteoroid and cometary impact processes which can explain the correlation in location of the strongest lunar magnetic anomalies with swirl-like high-albedo and low-albedo markings of the Reiner Gamma class. The results indicate that the relatively strong magnetization of basin antipode zones may have favored the formation of swirls in the same regions. The solar wind deflection model is tested by calculating the trajectories of simulated solar wind ions deflected by the Lorentz force in the presence of model crustal magnetic fields.

Hood, L. L.↗

Space Shuttle Orbiter nose cap thermal analysis

The results of a Space Shuttle Orbiter nose cap entry aeroheating assessment, thermal analysis, and correlation of flight data using multidimensional thermal math models (TMM's) and a chemically reacting boundary-layer program are described in this paper. The object of this study was to verify and revise, if required, the nose cap design heating methods and the TMM's used for flight certification. Flight temperature measurements from two Orbiter vehicles, Columbia and Challenger, have been used in this analysis and provide the basis for verification and correlation of the aerothermodynamic environment. Nose cap thermal response predictions, using TMM's verified from certification tests, show that the aerothermodynamic environment can be satisfactorily predicted using accepted analytical methods.

Curry, D. M.↗

In-Cell Deployment and First Use of Digital Image Correlation for In-Situ Strain Analysis of Irradiated Nuclear Fuel Rods During LOCA Transient

Digital image correlation (DIC) is a noncontact, optical method increasingly used across industries and research environments for acquiring multidimensional strain data. At Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS), DIC has been extensively applied to study the thermomechanical response of nuclear fuel claddings, yielding fundamental insights into material behavior. However, these efforts have focused exclusively on unirradiated materials and relied on the SATS out-of-cell infrastructure. Efforts over the past two years have been made to extend these capabilities to ORNL’s Irradiated Fuels Examination Laboratory SATS system within the hot-cells to enable testing of irradiated fuel cladding materials. Integrating DIC into the hot-cell SATS infrastructure presents unique challenges, including enabling remote operation of optical equipment and adapting auxiliary hot-cell systems for DIC implementation. This report discusses design, stand-up testing, and application of DIC to an irradiated nuclear fuel cladding segment. A DIC testing rig was successfully built and validated out-of-cell through extensive surrogate tests and calibrations. The rig and specialized DIC furnace were installed in the hot-cell, and a DIC test was successfully conducted. Results from that test correspond to expectations for Zr-based alloys and showed similar uncertainties compared to out-of-cell tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multivariate Analysis, Retrieval, and Storage System (MARS). Volume 6: MARS System - A Sample Problem (Gross Weight of Subsonic Transports)

The Mars system is a tool for rapid prediction of aircraft or engine characteristics based on correlation-regression analysis of past designs stored in the data bases. An example of output obtained from the MARS system, which involves derivation of an expression for gross weight of subsonic transport aircraft in terms of nine independent variables is given. The need is illustrated for careful selection of correlation variables and for continual review of the resulting estimation equations. For Vol. 1, see N76-10089.

Hague, D. S.↗

Study Of The Solar Wind Parameters During The 23rd Solar Cycle

In this paper we study the solar wind parameters during the 23rd solar cycle and the possible correlation between them. Those parameters' data, which are Alfven Mach number, plasma beta, flow speed, proton density and temperature, dynamic pressure, average magnetic field, Bx and By, has been taken from OMNI 2. The first part of this project is about analysis and correlation of the data, using Pearson's product moment correlation coefficient and Spearman Rank Correlation Coefficient, during the 11 years of the 23rd cycle. The second part is about Wavelet analysis on those parameters during the 21st, 22nd, 23rd solar cycles in comparison with them. We found that each parameter has different behavior in every cycle and certain periodicities that appear constantly.

79 ASTRONOMY AND ASTROPHYSICS↗

Design/Analysis of the JWST ISIM Bonded Joints for Survivability at Cryogenic Temperatures

A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite bonded joints below the cryogenic temperature of 30K (-405 F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to M55J/954-6 and T300/954-6 hybrid composite tubes (75mm square). Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.

Bartoszyk, Andrew↗

DSN Data Visualization Suite

The DSN Data Visualization Suite is a set of computer programs and reusable Application Programming Interfaces (APIs) that assist in the visualization and analysis of Deep Space Network (DSN) spacecraft-tracking data, which can include predicted and actual values of downlink frequencies, uplink frequencies, and antenna-pointing angles in various formats that can include tables of values and polynomial coefficients. The data can also include lists of antenna-pointing events, lists of antenna- limit events, and schedules of tracking activities. To date, analysis and correlation of these intricately related data before and after tracking have been difficult and time-consuming. The DSN Data Visualization Suite enables operators to quickly diagnose tracking-data problems before, during, and after tracking. The Suite provides interpolation on demand and plotting of DSN tracking data, correlation of all data on a given temporal point, and display of data with color coding configurable by users. The suite thereby enables rapid analysis of the data prior to transmission of the data to DSN control centers. At the control centers, the same suite enables operators to validate the data before committing the data to DSN subsystems. This software is also Web-enabled to afford its capabilities to international space agencies.

Bui, Bach X.↗

X-ray Spectroscopy for Quality Control of Chemotherapy Drugs

We develop a method, employing Compton peak standardization and the use of matrix-matched spiked samples with Total Reflection X-ray Fluorescence (TXRF), for the determination of platinum plasma concentrations of patients undergoing chemotherapy with Pt-bearing drugs. Direct blood plasma analysis attains Pt detection limits of 70 ng/ml. Measurement results of prescribed drug doses are compared to achieved blood Pt concentrations indicating a lack of expected correlations. Direct analysis of Pt-containing infused drugs from a variety of suppliers indicates cases of abnormal concentrations which raises quality control issues. We demonstrate the potential usefulness of the method for pharmacokinetic studies or for routine optimization and quality control of Pt chemotherapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analog computation of auto and cross-correlation functions

For analysis of the data obtained from the cross beam systems it was deemed desirable to compute the auto- and cross-correlation functions by both digital and analog methods to provide a cross-check of the analysis methods and an indication as to which of the two methods would be most suitable for routine use in the analysis of such data. It is the purpose of this appendix to provide a concise description of the equipment and procedures used for the electronic analog analysis of the cross beam data. A block diagram showing the signal processing and computation set-up used for most of the analog data analysis is provided. The data obtained at the field test sites were recorded on magnetic tape using wide-band FM recording techniques. The data as recorded were band-pass filtered by electronic signal processing in the data acquisition systems.

Source record↗

N2O as an indicator of Arctic vortex dynamics: Correlations with O3 over Thule, Greenland in February and March, 1992

We have recovered vertical profiles of stratospheric N2O from spectra observed using a ground-based mm-wave spectrometer during the Arctic spring. The measurements were made from Thule, Greenland (76.3 deg N, 68.4 deg W) on nine occasions from late February to late March, 1992 as part of the Upper Atmosphere Research Satellite (UARS) Correlative Measurements Program and the European Arctic Stratospheric Ozone Experiment (EASOE). During late February Thule was under inside edge of the Arctic vortex and mixing ratio profiles measured in that period are substantially reduced from typical high-latitude summer values. By late March the polar vortex had moved well away from Thule and N2O mixing ratios were greatly increased, coinciding with a basic change in circulation that brought in air from the Aleutian high. The motion of the vortex is also illustrated in the change in potential vorticity above Thule. A correlation with ozone balloonsonde data from Thule is made and compared to similar analyses of the Airborne Arctic Stratospheric Expedition (AASE) measurements. Within the sensitivity of our analysis, the correlation of N2O and O3 shows no evidence of ozone depletion within the vortex during this period; however, there is a distinct difference in the correlation inside and outside the vortex.

Emmons, L. K.↗

SU-E-T-144: Effective Analysis of VMAT QA Generated Trajectory Log Files for Medical Accelerator Predictive Maintenance

Purpose: To determine the effectiveness of SPC analysis for a model predictive maintenance process that uses accelerator generated parameter and performance data contained in trajectory log files. Methods: Each trajectory file is decoded and a total of 131 axes positions are recorded (collimator jaw position, gantry angle, each MLC, etc.). This raw data is processed and either axis positions are extracted at critical points during the delivery or positional change over time is used to determine axis velocity. The focus of our analysis is the accuracy, reproducibility and fidelity of each axis. A reference positional trace of the gantry and each MLC is used as a motion baseline for cross correlation (CC) analysis. A total of 494 parameters (482 MLC related) were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and parameter/system specifications. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: TG-142 and published analysis of VMAT delivery accuracy. Results: All errors introduced were detected. Synthetic positional errors of 2mm for collimator jaw and MLC carriage exceeded the chart limits. Gantry speed and each MLC speed are analyzed at two different points in the delivery. Simulated Gantry speed error (0.2 deg/sec) and MLC speed error (0.1 cm/sec) exceeded the speed chart limits. Gantry position error of 0.2 deg was detected by the CC maximum value charts. The MLC position error of 0.1 cm was detected by the CC maximum value location charts for every MLC. Conclusion: SPC I/MR evaluation of trajectory log file parameters may be effective in providing an early warning of performance degradation or component failure for medical accelerator systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x‐acceleration peak response correlated with the human response at 8 and 10‐G 100 ms but not 10‐G 70 ms. The phase lagged the human response. Head z‐acceleration was not correlated. Chest x‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x‐acceleration was not well correlated. Head and chest z‐acceleration was in phase but had a higher peak response. Chest z‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z‐displacement but the THOR was in phase and was comparable to the mean peak response. Head xand z‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, N.↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post-­‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi-­‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two-­‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x-­‐acceleration peak response correlated with the human response at 8 and 10-­‐G 100 ms but not 10-­‐G 70 ms. The phase lagged the human response. Head z-­‐acceleration was not correlated. Chest x-­‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x-­‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x-­‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x-­‐acceleration was not well correlated. Head and chest z-­‐acceleration was in phase but had a higher peak response. Chest z-­‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z-­‐displacement but the THOR was in phase and was comparable to the mean peak response. Head x-­‐ and z-­‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, Nate↗

The Cognition and Fine Motor Skills Test Batteries: Normative Data and Interdependencies

Space mission success and safety relies upon astronaut functional state. Since spaceflight stressors affect cognitive processing and fine motor skills, NASA requires that measures of performance of these things remain within clinically accepted values (NASA STD 3001). NASA is in the process of developing two test batteries for the assessment of crew cognitive and fine motor skills before, during and after spaceflight. Toward that goal, the current project collected normative scores in 91 “astronaut-like” military and civilian pilots. The Cognition Test Battery (CTB) contains ten sub-tests that measure a range of cognitive abilities. For five of the ten CTB sub-tests, we propose scores to improve the battery’s sensitivity. Among the ten sub-tests, response times were more highly correlated than accuracy scores. Principle component analysis of the correlations revealed that the first response time factor could explain over 40% of the total variance and appeared to represent the tendency of observers to try to respond more quickly. The first accuracy factor (explaining only 20%) gave a high weight to the higher level cognitive sub-tests and a negative weight to tasks associated with motor and lower level cognitive processing. The Fine Motor Skills (FMS) test battery contains four sub-tests (Tracking, Pointing, Tracing, Rotating) performed on an Apple iPad tablet computer. Principle component analysis on the sub-test response time correlations revealed that the first two factors accounted for ~80% of the variance in performance. The first component captured overall speed on all four of the sub-tests. The second factor separated the sub-tasks into two groups (Drag-Point vs Trace-Rotate). Previous work found the first group response times correlated with that of a standard peg board task, while those of the other group did not. Correlations were computed between the first FMS factor and the response time and accuracy scores from each CTB sub-task. Performing fine motor behaviors rapidly was significantly correlated with the ability to perform many of the CTB sub-tests rapidly. This ability cannot be simple motor speed since scores on the Psychomotor Vigilance Test (PVT) subtask did not correlate with the ability to perform the other tasks rapidly. Speed on fine motor skills correlated significantly with accuracy on the short-term-memory sub-test. We hypothesize that eye movements, which can be regarded as a fine motor skill, may explain this relationship.

cognition↗