Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Double diffraction in an atomic gravimeter

We demonstrate the realization of a scheme for cold-atom gravimetry based on the recently demonstrated use of double-diffraction beam splitters [T. Leveque, A. Gauguet, F. Michaud, F. Pereira Dos Santos, and A. Landragin, Phys. Rev. Lett. 103, 080405 (2009)], where the use of two retro-reflected Raman beams allows symmetric diffraction in +-(Planck constant/2pi)k{sub eff} momenta. Although in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneously resonant, such diffraction pulses can remain efficient on atoms with nonzero velocity, such as in a gravimeter, when the frequency of one of the two Raman laser sources is modulated. Such pulses are used to realize an interferometer insensitive to laser phase noise and some of the dominant systematics. This approach reduces the technical requirements and would allow the realization of a simple atomic gravimeter. A sensitivity of 1.2x10{sup -7}g per shot is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Complex-valued acquisition of the diffraction imaging by incoherent quasimonochromatic light without a support constraint

A scheme for complex-valued acquisition of the diffraction imaging with quasimonochromatic incoherent light is theoretically proposed. The main idea is to project the real and the imaginary parts of a Fraunhofer diffraction field on intensity distributions, respectively, with the use of a {pi}/2 phase-changing plate. The whole procedure is iterative algorithm free and needs no a priori knowledge of an arbitrary object. A numerical experiment and a quantitative confirmation are also given. To our knowledge, it was the first physical proposal for the complex-valued acquisition of a diffraction imaging by two-dimensional coherent patterns with thermal illumination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Projection of diffraction patterns for use in cold-neutral-atom trapping

Scalar diffraction theory is combined with beam-propagation techniques to investigate the projection of near-field diffraction patterns to spatial locations away from the aperture for use in optically trapping cold neutral alkali-metal atoms. Calculations show that intensity distributions with localized bright and dark spots usually found within a millimeter of the diffracting aperture can be projected to a region free from optical components such as a cloud of cold atoms within a vacuum chamber. Calculations also predict that the critical properties of the optical dipole atom traps are not only maintained for the projected intensity patterns but also can be manipulated and improved by adjustment of the optical components outside the vacuum chamber.

74 ATOMIC AND MOLECULAR PHYSICS↗

Diffraction of slow neutrons by holographic SiO{sub 2} nanoparticle-polymer composite gratings

Diffraction experiments with holographic gratings recorded in SiO{sub 2} nanoparticle-polymer composites have been carried out with slow neutrons. The influence of parameters such as nanoparticle concentration, grating thickness, and grating spacing on the neutron-optical properties of such materials has been tested. Decay of the grating structure along the sample depth due to disturbance of the recording process becomes an issue at grating thicknesses of about 100 microns and larger. This limits the achievable diffraction efficiency for neutrons. As a solution to this problem, the Pendelloesung interference effect in holographic gratings has been exploited to reach a diffraction efficiency of 83% for very cold neutrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light bullets in the spatiotemporal nonlinear Schroedinger equation with a variable negative diffraction coefficient

We report approximate analytical solutions to the (3+1)-dimensional spatiotemporal nonlinear Schroedinger equation, with the uniform self-focusing nonlinearity and a variable negative radial diffraction coefficient, in the form of three-dimensional solitons. The model may be realized in artificial optical media, such as left-handed materials and photonic crystals, with the anomalous sign of the group-velocity dispersion (GVD). The same setting may be realized through the interplay of the self-defocusing nonlinearity, normal GVD, and positive variable diffraction. The Hartree approximation is utilized to achieve a suitable separation of variables in the model. Then, an inverse procedure is introduced, with the aim to select a suitable profile of the modulated diffraction coefficient supporting desirable soliton solutions (such as dromions, single- and multilayer rings, and multisoliton clusters). The validity of the analytical approximation and stability of the solutions is tested by means of direct simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inherent issues regarding the use of in situ x-ray diffraction measurements to determine temperature in shock-compressed metals

Temperature determination in shock compressed solids constitutes an important and long-standing scientific need. Since the reduction of Bragg diffracted peaks due to temperature increase, using the Debye-Waller factor, is well established, we examined the use of this approach to determine temperatures in shock compressed gold and platinum by representing the shocked state as a superposition of density and temperature changes. Comparison of the calculated and measured diffraction peaks did not show good agreement, because x-ray diffraction (XRD) profiles in the shock compressed state are not governed solely by density and temperature changes. XRD results are also influenced measurably by shock wave induced microstructural changes. Our results demonstrate that contributions from microstructural changes need to be incorporated and modeled in the theoretical analysis to use XRD measurements for reliable temperature determination in shock compressed solids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of the commensurate magnetic structure in the heavy-fermion compound CePt 2 In 7 using magnetic resonant x-ray diffraction

In this paper, we investigated the magnetic structure of the heavy-fermion compound CePt 2 In 7 below T N = 5.34 (2) K using magnetic resonant x-ray diffraction at ambient pressure. The magnetic order is characterized by a commensurate propagation vector k 1/2 = (1/2, 1/2, 1/2) with spins lying in the basal plane. Our measurements did not reveal the presence of an incommensurate order propagating along the high-symmetry directions in reciprocal space but cannot exclude other incommensurate modulations or weak scattering intensities. The observed commensurate order can be described equivalently by either a single-k structure or by a multi-k structure. Furthermore we explain how a commensurate-only ordering may explain the broad distribution of internal fields observed in nuclear quadrupolar resonance experiments [Sakai et al., Phys. Rev. B 83, 140408 (2011)] that was previously attributed to an incommensurate order. We also report powder x-ray diffraction showing that the crystallographic structure of CePt 2 In 7 changes monotonically with pressure up to P = 7.3 GPa at room temperature. The determined bulk modulus B 0 = 81.1 (3) GPa is similar to those of the Ce-115 family. Broad diffraction peaks confirm the presence of pronounced strain in polycrystalline samples of CePt 2 In 7 . Lastly, we discuss how strain effects can lead to different electronic and magnetic properties between polycrystalline and single crystal samples.

36 MATERIALS SCIENCE↗

Neutron diffraction and μ SR studies of two polymorphs of nickel niobate NiNb 2 O 6

Neutron diffraction and muon spin relaxation (μSR) studies are presented in this paper for the newly characterized polymorph of NiNb 2 O 6 (β-NiNb 2 O 6 ) with space group P4 2 /n and μSR data only for the previously known columbite structure polymorph with space group Pbcn. The magnetic structure of the P4 2 /n form was determined from neutron diffraction using both powder and single-crystal data. Powder neutron diffraction determined an ordering wave vector → k=( 1 / 2 , 1 / 2 , 1 / 2 ). Single-crystal data confirmed the same → k vector and showed that the correct magnetic structure consists of antiferromagnetically coupled chains running along the a or b axis in adjacent Ni 2+ layers perpendicular to the c axis, which is consistent with the expected exchange interaction hierarchy in this system. The refined magnetic structure is compared with the known magnetic structures of the closely related trirutile phases, NiSb 2 O 6 and NiTa 2 O 6 . μSR data finds a transition temperature of T N ~15K for this system, while the columbite polymorph exhibits a lower T N =5.7(3) K. Our μSR measurements also allowed us to estimate the critical exponent of the order parameter β for each polymorph. We found β =0.25(3) and 0.16(2) for the β and columbite polymorphs, respectively. The single-crystal neutron scattering data give a value for the critical exponent β =0.28(3) for β-NiNb 2 O 6 , in agreement with the μSR value. While both systems have β values less than 0.3, which is indicative of reduced dimensionality, this effect appears to be much stronger for the columbite system. Finally, in other words, although both systems appear to be well described by S=1 spin chains, the interchain interactions in the β polymorph are likely much larger.

36 MATERIALS SCIENCE↗

Nuclear enhancement and suppression of diffractive structure functions at high energies

We compute diffractive structure functions for both protons and nuclei in the framework of color glass condensate models with impact parameter dependence. These models have previously been shown to provide good agreement with inclusive F{sub 2} measurements and exclusive vector meson measurements at DESY's Hadron-Electron Ring Accelerator (HERA). For nuclei, they provide good (parameter free) agreement with the inclusive F{sub 2} data. We demonstrate good agreement of our computations with HERA measurements on inclusive diffraction. We extend our analysis to nuclei and predict the pattern of enhancement and suppression of the diffractive structure functions that can be measured at an electron-ion collider. We discuss how the impact parameter dependence crucially affects our analysis, in particular for large invariant masses at fixed Q{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Incoherent diffractive J/{Psi} production in high-energy nuclear deep-inelastic scattering

We compute cross sections for incoherent diffractive J/{Psi} production in lepton-nucleus deep-inelastic scattering (DIS). The cross section is proportional to A in the dilute limit and to A{sup 1/3} in the black disk limit, with a large nuclear suppression due to saturation effects. The t dependence of the cross section, if it can be measured accurately enough, is sensitive to the impact parameter profile of the gluons in the nucleus and their fluctuations, a quantity that determines the initial conditions of a relativistic heavy-ion collision. The nuclear suppression in incoherent diffraction shows how the transverse spatial distribution of the gluons in the nucleus gradually becomes smoother at high energy. Since the values of the momentum transfer |t| involved are relatively large, this process should be easier to measure in future nuclear DIS experiments than coherent diffraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coherent diffraction of a single virus particle: The impact of a water layer on the available orientational information

Coherent diffractive imaging using x-ray free-electron lasers (XFELs) may provide a unique opportunity for high-resolution structural analysis of single particles sprayed from an aqueous solution into the laser beam. As a result, diffraction images are measured from randomly oriented objects covered by a water layer. We analyze theoretically how the thickness of the covering water layer influences the structural and orientational information contained in the recorded diffraction images. This study has implications for planned experiments on single-particle imaging with XFELs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent X-Ray Diffraction Imaging with Nanofocused Illumination

Coherent x-ray diffraction imaging is an x-ray microscopy technique with the potential of reaching spatial resolutions well beyond the diffraction limits of x-ray microscopes based on optics. However, the available coherent dose at modern x-ray sources is limited, setting practical bounds on the spatial resolution of the technique. By focusing the available coherent flux onto the sample, the spatial resolution can be improved for radiation-hard specimens. A small gold particle (size <100 nm) was illuminated with a hard x-ray nanobeam (E=15.25 keV, beam dimensions {approx_equal}100x100 nm{sup 2}) and is reconstructed from its coherent diffraction pattern. A resolution of about 5 nm is achieved in 600 s exposure time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-Shot Diffractive Imaging with a Table-Top Femtosecond Soft X-Ray Laser-Harmonics Source

Coherent x-ray diffractive imaging is a powerful method for studies on nonperiodic structures on the nanoscale. Access to femtosecond dynamics in major physical, chemical, and biological processes requires single-shot diffraction data. Up to now, this has been limited to intense coherent pulses from a free electron laser. Here we show that laser-driven ultrashort x-ray sources offer a comparatively inexpensive alternative. We present measurements of single-shot diffraction patterns from isolated nano-objects with a single 20 fs pulse from a table-top high-harmonic x-ray laser. Images were reconstructed with a resolution of 119 nm from the single shot and 62 nm from multiple shots.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 7 µm mini-beam improves diffraction data from small or imperfect crystals of macromolecules

An X-ray mini-beam of 8 × 6 µm cross-section was used to collect diffraction data from protein microcrystals with volumes as small as 150–300 µm{sup 3}. The benefits of the mini-beam for experiments with small crystals and with large inhomogeneous crystals are investigated. A simple apparatus for achieving beam sizes in the range 5-10 µm on a synchrotron beamline was implemented in combination with a small 125 × 25 µm focus. The resulting beam had sufficient flux for crystallographic data collection from samples smaller than 10 × 10 × 10 µm. Sample data were collected representing three different scenarios: (i) a complete 2.0 Å data set from a single strongly diffracting microcrystal, (ii) a complete and redundant 1.94 Å data set obtained by merging data from six microcrystals and (iii) a complete 2.24 Å data set from a needle-shaped crystal with less than 12 × 10 µm cross-section and average diffracting power. The resulting data were of high quality, leading to well refined structures with good electron-density maps. The signal-to-noise ratios for data collected from small crystals with the mini-beam were significantly higher than for equivalent data collected from the same crystal with a 125 × 25 µm beam. Relative to this large beam, use of the mini-beam also resulted in lower refined crystal mosaicities. The mini-beam proved to be advantageous for inhomogeneous large crystals, where better ordered regions could be selected by the smaller beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unit-cell determination from randomly oriented electron-diffraction patterns

An algorithm is described that calculates the most likely primitive unit cell given a set of randomly oriented electron-diffraction patterns with unknown angular relationships. Unit-cell determination is the first step towards the structure solution of an unknown crystal form. Standard procedures for unit-cell determination cannot cope with data collections that consist of single diffraction patterns of multiple crystals, each with an unknown orientation. However, for beam-sensitive nanocrystals these are often the only data that can be obtained. An algorithm for unit-cell determination that uses randomly oriented electron-diffraction patterns with unknown angular relationships is presented here. The algorithm determined the unit cells of mineral, pharmaceutical and protein nanocrystals in orthorhombic high- and low-symmetry space groups, allowing (well oriented) patterns to be indexed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the combination of molecular replacement and single-wavelength anomalous diffraction phasing for automated structure determination

The combination of molecular replacement and single-wavelength anomalous diffraction improves the performance of automated structure determination with Auto-Rickshaw. A combination of molecular replacement and single-wavelength anomalous diffraction phasing has been incorporated into the automated structure-determination platform Auto-Rickshaw. The complete MRSAD procedure includes molecular replacement, model refinement, experimental phasing, phase improvement and automated model building. The improvement over the standard SAD or MR approaches is illustrated by ten test cases taken from the JCSG diffraction data-set database. Poor MR or SAD phases with phase errors larger than 70° can be improved using the described procedure and a large fraction of the model can be determined in a purely automatic manner from X-ray data extending to better than 2.6 Å resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The design of macromolecular crystallography diffraction experiments

Thoughts about the decisions made in designing macromolecular X-ray crystallography experiments at synchrotron beamlines are presented. The measurement of X-ray diffraction data from macromolecular crystals for the purpose of structure determination is the convergence of two processes: the preparation of diffraction-quality crystal samples on the one hand and the construction and optimization of an X-ray beamline and end station on the other. Like sample preparation, a macromolecular crystallography beamline is geared to obtaining the best possible diffraction measurements from crystals provided by the synchrotron user. This paper describes the thoughts behind an experiment that fully exploits both the sample and the beamline and how these map into everyday decisions that users can and should make when visiting a beamline with their most precious crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The use of a mini-κ goniometer head in macromolecular crystallography diffraction experiments

Hardware and software solutions for MX data-collection strategies using the EMBL/ESRF miniaturized multi-axis goniometer head are presented. Most macromolecular crystallography (MX) diffraction experiments at synchrotrons use a single-axis goniometer. This markedly contrasts with small-molecule crystallography, in which the majority of the diffraction data are collected using multi-axis goniometers. A novel miniaturized κ-goniometer head, the MK3, has been developed to allow macromolecular crystals to be aligned. It is available on the majority of the structural biology beamlines at the ESRF, as well as elsewhere. In addition, the Strategy for the Alignment of Crystals (STAC) software package has been developed to facilitate the use of the MK3 and other similar devices. Use of the MK3 and STAC is streamlined by their incorporation into online analysis tools such as EDNA. The current use of STAC and MK3 on the MX beamlines at the ESRF is discussed. It is shown that the alignment of macromolecular crystals can result in improved diffraction data quality compared with data obtained from randomly aligned crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗