Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct current system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

GMLC Southeast Regional Consortium: Technology Driven Improvements to Power Grid Resiliency

Recognizing that electric grid challenges can differ by geographical regions across the US, the Department of Energy (DOE) created a pioneer regional partnership to provide technical assistance to stakeholders facing grid modernization challenges. The southeast regional teams will transfer technologies developed under DOE auspices to stakeholders for testing, evaluation, and market validation. Regional members will help define critical challenges and pave the way for transition of technologies to the commercial sector. Using the depth and expertise at Oak Ridge National Laboratory, Savannah River National Laboratory, University of Tennessee’s CURENT, CAPER and the Clemson 20 MVA Electrical Grid Laboratory—along with critical industry partners, such as Duke Energy, TVA, Southern Company, EPB, and Santee Cooper—the Southeast Regional Consortium team will conduct collaborative research to advance the state of the grid in the Southeast region and improve power system resiliency to enhance responsiveness, enable faster restoration of power, and increase distributed energy resource (DER) concentrations. This report provides details of the technical research and demonstration projects accomplished by Oak Ridge National Laboratory (ORNL) as part of the Southeast Regional Consortium. Specifically, ORNL analyzed the application of optical current and voltage measurements impedance relays which would enable step distance protection to be deployed on distribution systems. This would improve the precision of determining the geographic location of faults, increase network topology flexibility, and allow bi-directional power flow. Next, ORNL deployed time sensitive networking technology on the EPB fiberoptic data network to study the impact of increased sensor traffic on existing supervisory control and data acquisition data. The deterministic latency and high bandwidth were demonstrated by remotely inspecting a substation using a drone with full HD streaming video operated at the EPB Control Center. Finally, a new application-based communication and control system developed at ORNL call CSEISMIC was tested for future deployment on the EPB Control Center microgrid using a hardware-in-the-loop testbed that was also developed at ORNL. The controller was able to successfully optimize ancillary service when the microgrid is connected to the distribution network. The seamless islanding, resynchronization, and reconnection of the microgrid was also demonstrated through the testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Charge Reduction and Performance Analysis of a Heat Pump Water Heater Using R290 as a Refrigerant—A Field Study

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Soda Pop: A Time-Series Clustering, Alarming and Disease Forecasting Application

To introduce Soda Pop, an R/Shiny application designed to be a disease agnostic time-series clustering, alarming, and forecasting tool to assist in disease surveillance “triage, analysis and reporting” workflows within the Biosurveillance Ecosystem (BSVE). In this poster, we highlight the new capabilities that are brought to the BSVE by Soda Pop with an emphasis on the impact of methodological decisions. The Biosurveillance Ecosystem (BSVE) is a biological and chemical threat surveillance system sponsored by the Defense Threat Reduction Agency (DTRA). BSVE is intended to be user-friendly, multi-agency, cooperative, modular and threat agnostic platform for biosurveillance. In BSVE, a web-based workbench presents the analyst with applications (apps) developed by various DTRA funded researchers, which are deployed on-demand in the cloud(e.g., Amazon Web Services). These apps aim to address emerging needs and refine capabilities to enable early warning of chemical and biological threats for multiple users across local, state, and federal agencies. Soda Pop is an app developed by Pacific Northwest National Laboratory (PNNL) to meet the current needs of the BSVE for early warning and detection of disease outbreaks. Aimed for use bya diverse set of analysts, the application is agnostic to data source and spatial scale enabling it to be generalizable across many diseases and locations. To achieve this, we placed a particular emphasis on clustering and alerting of disease signals within Soda Pop without strong prior assumptions on the nature of observed diseased counts. Although designed to be agnostic to the data source, Soda Pop was initially developed and tested on data summarizing Influenza-Like Illness in military hospitals from collaboration with the Armed Forces Health Surveillance Branch. Currently, the data incorporated also includes the CDC’s National Notifiable Diseases Surveillance System(NNDSS) tables and the WHO’s Influenza A/B Influenza Data(Flunet). These data sources are now present in BSVE’s Postgres data storage for direct access. Soda Pop is designed to automate time-series tasks of data summarization, exploration, clustering, alarming and forecasting. Built as an R/Shiny application, Soda Pop is founded on the powerful statistical tool R.. Where applicable, Soda Pop facilitates nonparametric seasonal decomposition of time-series; hierarchical agglomerative clustering across reporting areas and between diseases within reporting areas; and a variety of alarming techniques including Exponential Weighted Moving Average alarms and Early Aberration Detection. Soda Pop embeds these techniques within a user-interface designed to enhance an analyst’s understanding of emerging trends in their data and enables the inclusion of its graphical elements into their dossier for further tracking and reporting. The ultimate goal of this software is to facilitate the discovery of unknown disease signals along with increasing the speed of detection of unusual patterns within these signals. Soda Pop organizes common statistical disease surveillance tasks in a manner integrated with BSVE data source inputs and outputs. The app analyzes time-series disease data and supports a robust set of clustering and alarming routines that avoid strong assumptions on the nature of observed disease counts. This attribute allows for flexibility in the data source, spatial scale, and disease types making it useful to a wide range of analysts.

97 MATHEMATICS AND COMPUTING↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗

Geothermal Resource Potential Assessment White Pine County, Nevada, NBMG Report 55

Geothermal resources can potentially contribute toward the renewable energy portfolio of White Pine County (WPC) in two ways: first through the direct conversion of heat energy into electricity, and the second by way of direct-use applications in which thermal energy is used as a source of heat for buildings, greenhouses, and related structures. Several known geothermal areas within WPC lie proximal to the Southwest Intertie power line currently under construction. A potential source of electricity could come from conventional geothermal systems associated with young faults and regions of active crustal deformation. These systems have a total installed capacity in the Great Basin region of nearly 1,000 MWe. White Pine County hosts several geothermal systems of this type, but none are currently producing electricity. White Pine County has relatively low rates of crustal deformation relative to western NV or the Wasatch region of Utah (e.g., faulting accommodating crustal extension). However, based on a review of the geology in the region, we conclude that sustained and reasonable exploration efforts could result in the discovery and development of one or more electricity-grade geothermal systems, with potential generation capacity at each system in the range of 1–20 MWe. In addition, a new and unproven type of potential geothermal resource termed “deep stratigraphic reservoirs” or “hot sedimentary aquifers” has recently been proposed in the western United States. White Pine County, and in particular, the northern Steptoe Valley, has some of the most promising potential for electricity generation from this type of reservoir in the United States. Preliminary calculations suggest that as much as 500 MWe of baseload electricity in the northern Steptoe Valley could be produced from this type of reservoir using wells reaching depths of 2 to 4 km. The economic feasibility remains unproven, but initial estimates are encouraging. Based on observed surface temperatures and flow rates of springs, several geothermal systems in WPC also have the potential for direct use, including the heating of buildings and greenhouses. Such uses could reduce the consumption of electricity generated from fossil fuels and could lead to economic expansion by extending the growing season for certain agricultural products and reducing utility costs.

15 GEOTHERMAL ENERGY↗

Performance of solid oxide fuel cells operated with coal syngas provided directly from a gasification process

Solid oxide fuel cells (SOFCs) are presently being developed for gasification integrated power plants that generate electricity from coal at 50+% efficiency. The interaction of trace metals in coal syngas with the Ni-based SOFC anodes is being investigated through thermodynamic analyses and in laboratory experiments, but direct test data from coal syngas exposure are sparsely available. This research effort evaluates the significance of SOFC performance losses associated with exposure of a SOFC anode to direct coal syngas. SOFC specimen of industrially relevant composition are operated in a unique mobile test skid that was deployed to the research gasifier at the National Carbon Capture Center (NCCC) in Wilsonville, AL. The mobile test skid interfaces with a gasifier slipstream to deliver hot syngas (up to 300°C) directly to a parallel array of 12 button cell specimen, each of which possesses an active area of approximately 2 cm2. During the 500 hour test period, all twelve cells were monitored for performance at four discrete operating current densities, and all cells maintained contact with a data acquisition system. Of these twelve, nine demonstrated good performance throughout the test, while three of the cells were partially compromised. Degradation associated with the properly functioning cells was attributed to syngas exposure and trace material attack on the anode structure that was accelerated at increasing current densities. Cells that were operated at 0 and 125 mA/cm² degraded at 9.1 and 10.7% per 1000 hours, respectively, while cells operated at 250 and 375 mA/cm² degraded at 18.9 and 16.2% per 1000 hours, respectively. Post-trial spectroscopic analysis of the anodes showed carbon, sulfur, and phosphorus deposits; no secondary Ni-metal phases were found.

Environmental Molecular Sciences Laboratory↗

Increase resistance for efficient heating

Conductors for use in heating systems are provided. The conductors are configured to have an extended current path for the current and increased resistance as seen by the current. The heating system may be an induction system. For example, the conductor may comprise a conductive material having a surface which faces an induction coil of an oscillating circuit. This surface may have a predetermined pattern of peaks and valleys. The peaks and valleys form a non-linear current path for the induced current when exposed to an electromagnetic field generated by the oscillating circuit. Other conductors such as a heat pipe may be used. The pipe may have walls with varying thicknesses over its length. The varying thicknesses may include a first thickness and a second thickness which alternate. The heat pipe may be used in an induction or direct contact heating system where AC is directly applied to the pipe.

Kisner, Roger A.↗

System Architecture Directions for Post-SoC/32-bit Networked Sensors

The emergence of low-power 32-bit Systems-on-Chip (SoCs), which integrate a 32-bit MCU, radio, and flash, presents an opportunity to re-examine design points and trade-offs at all levels of the system architecture of networked sensors. To this end, we develop a post-SoC/32-bit design point called Hamilton, showing that using integrated components enables a ~$7 core and shifts hardware modularity to design time. We study the interaction between hardware and embedded operating systems, identifying that (1) post-SoC motes provide lower idle current (5.9 μA) than traditional 16-bit motes, (2) 32-bit MCUs are a major energy consumer (e.g., tick increases idle current >50 times), comparable to radios, and (3) thread-based concurrency is viable, requiring only 8.3 μs of context switch time. We design a system architecture, based on a tickless multithreading operating system, with cooperative/adaptive clocking, advanced sensor abstraction, and preemptive packet processing. Its efficient MCU control improves concurrency with ~30% less energy consumption. Together, these developments set the system architecture for networked sensors in a new direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results and lessons learned from accelerating radio frequency modeling using machine learning [slides]

The “advanced tokamak” reactor concept is a leading candidate for a steady state fusion pilot plant. An advanced tokamak (AT) sustains a majority of the required plasma current with effects resulting from maintenance of the peaked pressure at the device center. This current is augmented by auxiliary current drive sources. These auxiliary actuators may consist of neutral particle beams and/or radio frequency (RF) systems such as lower hybrid current drive (LHCD) and high harmonic fast wave (HHFW) current drive using radio and microwaves from antennas. The primary focus of this work is to develop models of RF current profile control suitable for use in integrated modeling frameworks and for real-time control in experiments. Direct physics models of RF current drive can be computationally intensive. In order to achieve predictive times appropriate for the thousands of calls needed in real-time control of experiments and for use in integrated models, we will apply modern machine learning (ML) techniques to accelerate these models and interpolate their results. To generate the fast and accurate models for use in control level algorithms and integrated modeling we need to replace present models with high dimensional interpolation of their results. We will perform additional simulations across a broader parameter range for EAST and other tokamaks in different physics regimes (Alcator C-Mod, DIII-D, WEST, CFETR, ARC, ITER) and combine them into a larger database for training and testing of the ML models. Further testing of the control level models with experimental current profile data from EAST and C-Mod tokamaks will provide additional confirmation of the control level model before integration in a tokamak control system or integrated modeling suite. ML will be used to optimize the selection of training data consisting of RF current driven at different values of density profile, temperature profile, plasma current, and wavenumber. ML will also be used to facilitate classification of current drive from these input data. The output of this effort will be a validated classifier capable of determining the current drive profiles for HHFW CD and LHCD on a mille-second timescale. This will provide a breakthrough capability enabling real-time control of RF driven current profiles in experiments including ITER ICRF and use integrated modeling frameworks requiring thousands of current profile calculations in discharge simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementing a Low-Activity Waste Direct Feed Capability in the Waste Treatment and Immobilization Plant Project - 15594

The current design of the Waste Treatment and Immobilization Plant (WTP) requires that all waste be processed through the Pretreatment (PT) Facility. The U.S. Department of Energy (DOE) has developed a strategic, phased approach to completing the WTP Project, beginning with feeding some liquid waste from the tank farms to the Low-Activity Waste (LAW) Facility, bypassing the PT Facility. To accomplish this, the DOE Office of River Protection (ORP) will construct a new capability outside WTP to remove cesium and solids from the liquid portion of the tank waste before transferring that waste to the LAW Facility. This new capability, referred to as the Low-Activity Waste Pretreatment System, is outside WTP and not included in the project's scope. The primary driver for the Direct-Feed LAW (DFLAW) approach is to enable commissioning of the LAW Facility for low-activity waste processing before the PT and High-Level Waste Facilities are complete and operational. As such, the functions intended to be provided to the LAW Facility by the PT Facility and the common functionality with the High-Level Waste Facility must be refined and modified. The DFLAW approach will provide necessary systems and facilities to replace these enabling PT Facility functions until the PT Facility is completed and commissioned. In February 2014, ORP requested the WTP contractor to develop separate contract modification proposals for completing: (1) the LAW Facility, Balance of Facilities, and Analytical Laboratory work scope in the current contract through hot commissioning in a manner to accommodate a phased start of the WTP mission; and (2) initial planning and design for incorporating a permanent capability to accommodate DFLAW in the WTP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems

Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved closed-loop proportional control algorithms was compared with that of the current (modified) closed-loop proportional control algorithm. In the results, the average maintenance percentage and the average discrepancies of the target illuminance, as well as the average time under 90percent of target illuminance for the integrated systems significantly improved in comparison with the current closed-loop proportional control algorithm for daylight responsive dimming systems as a single system.

30 DIRECT ENERGY CONVERSION↗

Grain Handling and Transportation Policy in Canada: Implications for the United States

The grain handling and transportation system in Canada (GHTS) is currently going through a major transition, both with respect to handling and transportation. Historically, the system has pitted farmers against the railways with respect to securing individual fair shares of grain revenues. But with the removal of the single desk marketing and logistics function of the Canadian Wheat Board (CWB) in late 2012, a very interesting and potentially game-changing outcome is emerging with respect to the new functionality of the grain companies in the Canadian system. While historical awareness of rail s natural monopoly position in the grain handling system has kept that sector regulated (in several ways) for close to a century, we are now starting to see the effects of a less than competitive Canadian grain handling sector on revenue sharing, along with renewed movement in the industry with respect to buyouts and potential mergers. This overview will highlight some of the changes now occurring and how they are potentially going to interact or evolve as the system moves forward. For example, the on-going regulatory instrument used to regulate grain transportation rates in Canada (called the maximum revenue entitlement (MRE) or revenue cap) is under current debate because of the introduction a few months ago of a modification to an old regulatory instrument known as extended (or reciprocal) interswitching. As opposed to the revenue cap which is a direct intervention on monopoly behavior, extended interswitching is designed to encourage the major Canadian grain carriers to compete with one another and potentially seek out new traffic (Nolan and Skotheim, 2008). But the most intriguing aspect of extended interswitching is how it might allow a major rail carrier from the U.S. to solicit grain traffic in some areas of the Canadian grain transportation system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sandia Cloud Forensics and Incident Response Platform v 1.0

As systems and devices become virtualized and deployed in the cloud, the hypervisor becomes an increasingly appropriate place to collect performance data, system state, system landscape, function calls, transaction traces, and other characteristics. We developed a method by which an introspection application may be coupled with a hypervisor to “reach into” the VM with minimal intrusiveness to collect data critical to the reconstruction of events, files, and operations. Such a capability is required to take advantage of the hypervisor as an instrumentation platform and to integrate that data with more traditional collection mechanisms. The concept of a VM serviced by a lightweight hypervisor is a relatively new paradigm for forensic practitioners. Traditional forensic techniques, based on assumptions that the filesystem was directly interacting with the hardware through an abstraction, afforded the forensic practitioner the assumption that there was nothing controlling the application below the filesystem. This is not the case when using virtualized technologies. Hypervisors can covertly monitor, introspect and interact with the guest in a transparent fashion. The problems of storage and collection of actionable data are exhausting. The current challenge is most hypervisors do not expose a useful application programming interface (API) at a sufficient level to do transparent, fine-grained and customizable introspection. Scalable VM instrumentation and introspection at an in-depth level requires fast handling of events, as well as direct access to VM state. Furthermore, deep introspection benefits greatly from the ability to gather data from the hardware during the VM’s exit to the hypervisor. All of this requires identical access to the system as the hypervisor itself; improper use of this ability could easily cause system instability. It is for this reason we believe that the hypervisor developers have been hesitant to grant this much control through their APIs. However, our approach leverages other means to collect and monitor the guests in a targeted fashion. Virtual machine introspection (VMI) is a technique used to monitor the runtime state of a system-level virtual machine. The runtime state can be may include processor registers, memory, disk, network, and any other hardware-level events A review of research literature and current VMI technologies exposed several limitations and tradeoffs in VMI approaches, including: the use of in-guest agents; kernel to user space transitions (dramatically slowing down processing); VMI tool pre-configuration requirements; hypervisor version lock-in or source code patching; reliance on operating system symbols; limited processor features due to hypervisor (even if the hardware could do more). To address these constraints, a VMI tool was envisioned to provide the cloud forensic capabilities while having as few of these limitations as possible. The Kernel-based Virtual Machine Introspection (KVMi) tool was developed for hypervisors on Intel’s x86-64 architecture. To meet performance, scoping and use-case demands, the follow criteria were applied to KVMi to support live, forensic data collection: • Shall not require in-guest agents. • Shall work with any recent version of modern hypervisors. • Shall introspect upon any guest (VM) running modern versions of Windows, Linux and OS X. • Shall have the ability to find and track operating system artifacts • Shall not require operating system symbol files. • Shall be able to fully handle VM-exits, bypassing execution of the hypervisor if necessary, to facilitate new features the hypervisor may not support. • Shall be compilable/loadable on a running system with standard build tools.

Stout, WilliamM.S.↗

Energy Efficient Clothes Dryer with IR Heating and Electrostatic Precipitator

The project goal was to develop a revolutionary energy saving technology for residential clothes drying. The team developed an IR (infrared) heating system and NESP (Nebulizer and Electro-Static Precipitator) for integration into a ventless clothes dryer. The proposed technology addresses two of the major inefficiencies in current electric vented dryers by providing effective energy transfer for the removal of the water and recapture of the vapor latent heat. The IR heaters operating in the mid wave (2.5-10um) are very efficient as they target the 3-micron peak absorption of the water molecule. This allows direct energy absorption, unlike conventional element heaters where heat is transferred by convection. The low power NESP removes water vapor from the exhausted stream and recaptures the latent heat in the ESP (Electro-Static Precipitator) exchanger section. This allows the warm dry air to be recirculated back into the drum for additional efficiency savings. The remaining majority of the dryer hardware stays the same. Summing the efficiency gain from the two subcomponents we anticipated the EF (Efficiency Factor) to exceed the goal of 4.04. EF is obtained by dividing the weight (lbs) of water removed by the energy (kWhr) used, where the test load size is 8.45 lbs of bone dry clothing wetted to 57.5% or 4.8lbs of water, and dried to a remaining moisture content of 2.5-5%. Additional benefits include not having to recondition (heat or cool) the large amounts of make-up air to replace the air exhausted by a vented dryer. It was anticipated that the NESP/heat exchanger would be the most challenging and highest risk element in the program. Therefore, the team focused their efforts during Phase 1 of the program on the design, construction, testing, and optimization of the NESP/heat exchanger. At the end Phase 1, the team compared the performance of the NESP/heat exchanger with the system level requirements and made a Go/No-Go decision on proceeding with the second portion of the program. Phase 2 of the program was structured to develop the IR heating system and then integrate it and the NESP/heat exchanger into a residential clothes dryer prototype for final testing. The proposed technology utilizes heat recovery which is known to have the biggest impact on dryer efficiency. The two current mainstream recovery approaches are air to air exchangers and heat pump condenser systems. Air to air exchanges can be very efficient but require large surface areas which are prone to fouling from uncaptured lint. Dryers based on heat pump condenser recovery systems have shown efficiency improvements of 20–60% and are commercially available. The issue with a heat pump condenser approach is the added cost, as typical prices are twice that of standard vented dryers and they are only available in small to medium capacities. The energy factor (EF) for these systems is 5.50 to 6.88 pounds/kWh compared to conventional dryers at 2.75 to 3.67 pounds/kWh. The efficiency improvements for the proposed technology come from the use of IR heating and the NESP. As the concept is in its infancy, and these improvements were difficult to predict without experimental data, assumptions were made based on available literature. IR radiant drying times, when compared to convection, are typically 30% less. This is a result of the fact that radiant energy heats directly and is absorbed at and below the surface, unlike convection heating, that must conduct the heat through the boundary film of air at the clothes surface and rely on wicking of the moisture to the surface. The second area of improvement comes from the NESP. The NESP operation is as follows: 1. Highly charged, micron sized, droplets of water are injected into the dryer exhaust by the Nebulizer. 2. These charged droplets attract water molecules and continue to grow in size, until losing their charge. During this process, latent heat is rejected back into the air stream. 3. The large droplets enter the ESP, where they are recharged and drawn to the ESP wall, to be extracted at the bottom of the ESP. The warm dry air is then recirculated back into the dryer. The proposed technology, at the time of the proposal submission was estimated to have an EF of 4.79. At program completion we have designed, built, tested, integrated and optimized the proposed technologies into a prototype “high efficiency” residential clothes dryer. Testing of the integrated prototype dryer provided insight into the technical effectiveness and economic feasibility of the proposed technologies. The program has the potential of greatly impacting energy savings. The predicted EF of the proposed technology is 4.79, yielding an energy savings of 42% when compared to conventional electric vented dryers. Given there are approximately 84 million dryers in the US consuming ~64 billion kWh per year, a net savings of 27 billion kWh per year or 0.092 quads could be realized. Since the dryer is not vented, make up air from the room is not needed, adding an additional savings of ~1kWh per load, or 23.8 billion kWh per year. In addition, it is envisioned that the proposed ESP, when successful, would potentially find applications in industrial and residential dehumidification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determining Utility System Value of Demand Flexibility From Grid-interactive Efficient Buildings

This report focuses on ways current methods and practices that establish the value to electric utility systems of distributed energy resource (DER) investments can be enhanced to determine the value of demand flexibility in grid-interactive efficient buildings that can provide grid services. The report introduces key valuation concepts that are applicable to demand flexibility that these buildings can provide and links to other documents that describe these concepts and their implementation in more detail.The scope of this report is limited to the valuation of economic benefits to the utility system. These are the foundational values on which other benefits (and costs) can be built. Establishing the economic value to the grid of demand flexibility provides the information needed to design programs, market rules, and rates that align the economic interest of utility customers with building owners and occupants. By nature, DERs directly impact customers and provide societal benefits external to the utility system. Jurisdictions can use utility system benefits and costs as the foundation of their economic analysis but align their primary cost-effectiveness metric with all applicable policy objectives, which may include customer and societal (non-utility system) impacts.This report suggests enhancements to current methods and practices that state and local policymakers, public utility commissions, state energy offices, utilities, state utility consumer representatives, and other stakeholders might support. These enhancements can improve the consistency and robustness of economic valuation of demand flexibility for grid services. The report concludes with a discussion of considerations for prioritizing implementation of these improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber–physical vulnerability and resiliency analysis for DER integration: A review, challenges and research needs

High penetration of renewable and sustainable Distributed Energy Resources (DER) into the traditional distribution system requires a well-coordinated control strategy for the improvement of system-wide reliability and resiliency. Implementation of such a holistic control architecture requires a flexible, near real-time, and bi-directional communication framework for facilitating the participation of various agents in a multi-vendor heterogeneous smart grid. While the sustainability of energy generation is ensured, this exposes the smart grid to extrinsic cyber threats, and appropriate defense mechanism(s) must be deployed to guarantee continued reliability and resiliency of the power grid. Further, the comprehensive literature review presented in this paper discusses the latest trends in the DER control schemes with fast communication requirements and their accompanying cyber–physical vulnerabilities. These control schemes are compared and contrasted for various traits. A three-level DER system architecture has been depicted, facilitating the deployment of these control schemes. The current developments of standard communication protocols, key security mechanisms, and best practices along major standards and guidelines are explored. The impacts of different attack types with miscellaneous DER functions based on various control schemes and associated mitigation solutions are also provided. Finally, challenges and future research directions for limiting cyber-power susceptibility to enhance resiliency are summarized. The work presented here will help us enabling a cyber-resilient and sustainable smart electric grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Aqueous and Powder Processing Techniques for Production of Pu-238-Fueled General Purpose Heat Sources

This report evaluates alternative processes that could be used to produce Pu-238 fueled General Purpose Heat Sources (GPHS) for radioisotope thermoelectric generators (RTG). Fabricating GPHSs with the current process has remained essentially unchanged since its development in the 1970s. Meanwhile, 30 years of technological advancements have been made in the fields of chemistry, manufacturing, ceramics, and control systems. At the Department of Energy’s request, alternate manufacturing methods were compared to current methods to determine if alternative fabrication processes could reduce the hazards, especially the production of respirable fines, while producing an equivalent GPHS product. An expert committee performed the evaluation with input from four national laboratories experienced in Pu-238 handling.

30 DIRECT ENERGY CONVERSION↗