Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Validation of ANSI N42.34 – American National Standard Performance Criteria for Hand-Held Instruments for the Detection and Identification of Radionuclides

SRNL’s validation of ANSI N42.34-D6 for the Domestic Nuclear Detection Office (DNDO) was performed utilizing one hand-held instrument (or RID) – the FLIR identiFINDER 2. Each section of the standard was evaluated via a walk-through or test. NOTE: In Table 1, W = walk-through and T = test, as directed by the Domestic Nuclear Detection Office (DNDO). For a walk-through, the experiment was either setup or reviewed for setup; for a test, the N42.34-D6 procedures were followed with some exceptions and comments noted. SRNL is not fully able to evaluate a RID against Sections 7 (Environmental), 8 (Electromagnetic), and 9 (Mechanical) of N42.34, so those portions of this validation were done in collaboration with Qualtest, Inc. in Orlando, Florida. The walk-throughs and tests of Sections 7, 8, and 9 were performed in Qualtest, Inc. facilities with SRNL providing radiological sources as necessary. Where applicable, assessment results and findings of the walk-throughs and tests were recorded on datasheets and a validation summary is provided. A general comment pertained to test requirements found in another standard and referenced in N42.34-D6. For example, step 1 of the test method in section 8.1.2 states “RF test set up information can be found in IEC 61000-4-3.” It is recommended that any information from other standards necessary for conducting the tests within N42.34 should be posted in N42.34 for simplicity and to prevent the user from having to peruse other documents. Another general comment, as noted by Qualtest, is that a tolerance reference is not listed for each test in sections 7-9. Overall, the N42.34-D6 was proven to be practicable, but areas for improvement and recommendations were identified for consideration prior to final ballot submittal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electroproduction of Excited Baryons with the CLAS Detector in Hall B of Jefferson Lab

Recent results from Jefferson Lab (JLab) on the extraction of single-and double-polarization observables in both the 1{pi}-and 2{pi}-channel show their high sensitivity to resonant production amplitudes and therefore their importance for the extraction of resonance parameters. The CEBAF Large Acceptance Spectrometer (CLAS) has access to the baryon resonance (N*) form factors at high Q{sup 2}, which is advantageous for the study of the dynamical properties of nucleon resonances. In anticipation of the 12 GeV energy upgrade to JLab, our group plans to extract the electromagnetic transition form factors (electrocouplings) for many well-established excited nucleon states in the unexplored domain of Q{sup 2}>5 GeV{sup 5}. The expected data on resonance electro-couplings will allow us to systematically explore how in the strong interaction regime of QCD bare quarks are dressed with gluons and how quark cores of the various N* states emerge from QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of laser wavelength on emission and particle dynamics of Sn plasma

We investigated the effects of laser wavelength on the atomic, ionic, and radiative emission from laser-produced tin plasmas. For generating plasmas, planar tin targets were excited using either high intensity neodymium-doped yttrium aluminum garnet (Nd:YAG, 1.06 {mu}m) or carbon dioxide (CO{sub 2}, 10.6 {mu}m) laser pulses; both are considered to be potential excitation lasers for an extreme ultraviolet (EUV) lithography laser-produced plasma light source. Various diagnostic tools were utilized for investigating ionic, neutral, and radiative emission from Sn plasmas including Faraday cup, witness plate in conjunction with x-ray photoelectron spectroscopy (XPS), EUV, and visible emission spectroscopy and photography. Atomic and ionic analysis showed that the amount of debris emitted by the Nd:YAG generated plasmas was considerably higher than the CO{sub 2} laser-produced plasmas. The angular distributions of both atomic and ionic debris were found to be more forward-centric for the 1.06 {mu}m generated plasma while being much more uniform for the 10.6 {mu}m heated plasma. EUV and visible emission images of the plasma also showed a forward-centric appearance for 1.06 {mu}m heated plasmas. The strength of excited neutral emission was considerably lower for the case of the 10.6 {mu}m plasma while the kinetic energies of ions debris were found to be much higher for CO{sub 2} generated plasmas. Surface analysis of the craters created by the lasers showed that the mass ablation rate is 3.6 times higher for Nd:YAG laser generated plasmas compared to CO{sub 2} generated plasmas at maximum EUV emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DVCS - HERMES

The study of Generalised Parton Distributions (GPDs) promises to provide new knowledge of the structure of the nucleon, including, most notably, access to the total angular momentum of quarks within the nucleon. It can be difficult to ascertain new information on the distributions, but amongst all the exclusive processes that can provide access, Deeply Virtual Compton Scattering (DVCS) is relatively simple and experimentally accessible. The HERMES collaboration has the most diverse results pertaining to DVCS of any experiment, extracting asymmetries in the azimuthal distribution of produced photons according to both beam helicity and charge and target spin state. In this talk, we provide an overview of the HERMES DVCS result catalogue and explain how the results are used to improve constraints on the underlying GPDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coherent photoproduction of {pi}{sup +} from {sup 3}He with CLAS at Jefferson Lab

We have measured the differential cross section for the {gamma}{sup 3}He{yields}{pi}{sup +}t reaction. This reaction was studied using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. Real photons produced with the Hall-B bremsstrahlung tagging system in the energy range from 0.5 to 1.55 GeV were incident on a cryogenic liquid {sup 3}He target. The differential cross sections for the {gamma}{sup 3}He{yields}{pi}{sup +}t reaction were measured as a function of photon-beam energy and pion-scattering angle. Theoretical predictions to date cannot explain the large cross sections except at backward angles, showing that additional components must be added to the model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 10{sup 9} neutrons/pulse transportable pulsed D-D neutron source based on flexible head plasma focus unit

A 17 kJ transportable plasma focus (PF) device with flexible transmission lines is developed and is characterized. Six custom made capacitors are used for the capacitor bank (CB). The common high voltage plate of the CB is fixed to a centrally triggered spark gap switch. The output of the switch is coupled to the PF head through forty-eight 5 m long RG213 cables. The CB has a quarter time-period of 4 μs and an estimated current of 506 kA is delivered to the PF device at 17 kJ (60 μF, 24 kV) energy. The average neutron yield measured using silver activation detector in the radial direction is (7.1 ± 1.4) × 10{sup 8} neutrons/shot over 4π sr at 5 mbar optimum D{sub 2} pressure. The average neutron yield is more in the axial direction with an anisotropy factor of 1.33 ± 0.18. The average neutron energies estimated in the axial as well as in the radial directions are (2.90 ± 0.20) MeV and (2.58 ± 0.20) MeV, respectively. The flexibility of the PF head makes it useful for many applications where the source orientation and the location are important factors. The influence of electromagnetic interferences from the CB as well as from the spark gap on applications area can be avoided by putting a suitable barrier between the bank and the PF head.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-contrast tomography at the nanoscale using hard x rays

Synchrotron-based full-field tomographic microscopy established itself as a tool for noninvasive investigations. Many beamlines worldwide routinely achieve micrometer spatial resolution while the isotropic 100-nm barrier is reached and trespassed only by few instruments, mainly in the soft x-ray regime. We present an x-ray, full-field microscope with tomographic capabilities operating at 10 keV and with an isotropic resolution of 144 nm. Custom-designed optical components allow for ideal, aperture-matched sample illumination and very sensitive phase contrast imaging. We show here that the instrument has been successfully used for the nondestructive, volumetric investigation of single cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent photoproduction of {pi}{sup +} from {sup 3}He

We have measured the differential cross section for the {gamma}{sup 3}He{yields}{pi}{sup +}t reaction. This reaction was studied using the Continuous Electron Beam Accelerator Facility (CEBAF) Large Acceptance Spectrometer (CLAS) at Jefferson Lab. Real photons produced with the Hall-B bremsstrahlung tagging system in the energy range from 0.50 to 1.55 GeV were incident on a cryogenic liquid {sup 3}He target. The differential cross sections for the {gamma}{sup 3}He{yields}{pi}{sup +}t reaction were measured as a function of photon-beam energy and pion-scattering angle. Theoretical predictions to date cannot explain the large cross sections except at backward angles, showing that additional components must be added to the model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Holographic Lithography for Industrial Nanomanufacturing

The participant constructed interference lithography experiments on their prototype of a coordinated holographic industrial-scale electromagnetic lithography (CHISEL) tool. These experiments involved generating several laser beams and interfering them in photosensitive materials, whereupon subsequent development resulted in micro- and nano-structured samples. We characterized these samples using scanning electron microscopy and various optical interrogation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seismic wave generation systems and methods for cased wells

A vibration source (10) includes an armature bar (12) having a major length dimension, and a driver (20A) positioned about the armature bar. The driver (20A) is movably coupled to the armature bar (12), and includes an electromagnet (40). During operation the electromagnet (40) is activated such that the driver (20A) moves with respect to the armature bar (12) and a vibratory signal is generated in the armature bar. A described method for generating a vibratory signal in an object includes positioning the vibration source (10) in an opening of the object, coupling the armature bar (12) to a surface of the object within the opening, and activating the electromagnet (40) of the driver (20A) such that the driver moves with respect to the armature bar (12) and a vibratory signal is generated in the armature bar and the object.

47 OTHER INSTRUMENTATION↗

Nano structural anodes for radiation detectors

Anodes for proportional radiation counters and a process of making the anodes is provided. The nano-sized anodes when present within an anode array provide: significantly higher detection efficiencies due to the inherently higher electric field, are amenable to miniaturization, have low power requirements, and exhibit a small electromagnetic field signal. The nano-sized anodes with the incorporation of neutron absorbing elements (e.g., .sup.10B) allow the use of neutron detectors that do not use .sup.3He.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Footwear scanning systems and methods

Methods and apparatus for scanning articles, such as footwear, to provide information regarding the contents of the articles are described. According to one aspect, a footwear scanning system includes a platform configured to contact footwear to be scanned, an antenna array configured to transmit electromagnetic waves through the platform into the footwear and to receive electromagnetic waves from the footwear and the platform, a transceiver coupled with antennas of the antenna array and configured to apply electrical signals to at least one of the antennas to generate the transmitted electromagnetic waves and to receive electrical signals from at least another of the antennas corresponding to the electromagnetic waves received by the others of the antennas, and processing circuitry configured to process the received electrical signals from the transceiver to provide information regarding contents within the footwear.

47 OTHER INSTRUMENTATION↗

The Status and Prospects of the Muon $g-2$ Experiment at Fermilab

The E989 Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic anomaly, $a_\mu$, to an unprecedented precision of 140 parts per billion (ppb), representing a four-fold improvement over the current best measurement, achieved at Brookhaven National Lab. There stands a greater than 3 standard deviations discrepancy between the Brookhaven measurement of $a_\mu$ and the theoretical value predicted using the Standard Model. The Fermilab experiment seeks to either resolve or confirm this discrepancy, which is suggestive of new physics interactions. To achieve the E989 target precision, the anomalous precession frequency of muons in a magnetic storage ring must be determined with a systematic uncertainty below 70\,ppb, and the average magnetic field experienced by these stored muons must be known equally well. The muon anomalous precession frequency is imprinted on the time-dependent energy distribution of decay positrons observed by 24 electromagnetic calorimeters. A suite of pulsed NMR probes continually monitors the magnetic field. This document presents the current status of the Fermilab experiment while emphasizing the ongoing analysis of the 2018 Run 1 dataset and the systematic effects that complicate it.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

$\nu_e$ CC Event Identification Based on Shower Energy Profiles in LArTPCs

• Neutrino oscillations → Neutrinos have mass. Insight into physics beyond the Standard Model. • Liquid Argon Time Projection Chamber (LArTPC): - Distinguish between $e^-$ and $\gamma$ electromagnetic showers. - Exceptional calorimetry and tracking capabilities. • Weak interaction: - Neutral current (NC): $\nu_e \eta \to \nu_e \eta$ - Charged current (CC): $\nu_e \eta \to e^- p$ • Goal: Identify and select $e^-$ showers to do $\nu_e$ CC analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OBSERVED CORE OF A GRADUAL SOLAR ENERGETIC PARTICLE EVENT

Using space-borne particle and EUV detection and radio spectrograms from both ground-based and space-borne instruments, we study the first phase of the major solar energetic particle (SEP) event associated with the western solar flare and fast and wide coronal mass ejection (CME) on 2000 April 4. The SEP event being observed at the magnetic connection to the eruption's center starts with deka-MeV nucl{sup -1} helium- and relativistic electron-rich production from coronal sources identified with the electromagnetic diagnostics and the SEP event modeling. The broadband observations and modeling of the initial phase of the 'well-connected' major SEP event support the idea that acceleration of SEPs starts in the helium-rich plasma of the eruption's core in association with coronal shocks and magnetic reconnections caused by the CME liftoff, and that the coronal component dominates during the first hour of the SEP event considered, not yet being shielded by the CME bow shock in the solar wind. The first phase of the SEP event is followed by a second phase of SEP production associated with a decelerating CME-driven shock wave in the solar wind, which accelerates ions from a distinct, helium-poor seed particle population that may originate from the CME interaction with a coronal streamer.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrical Resistivity Investigation of Gas Hydrate Distribution in Mississippi Canyon Block 118, Gulf of Mexico

Electrical methods offer a geophysical approach for determining the sub-bottom distribution of hydrate in deep marine environments. Methane hydrate is essentially non-conductive. Hence, sediments containing hydrate are more resistive than sediments without hydrates. To date, the controlled source electromagnetic (CSEM) method has been used in marine hydrates studies. This project evaluated an alternative electrical method, direct current resistivity (DCR), for detecting marine hydrates. DCR involves the injection of direct current between two source electrodes and the simultaneous measurement of the electric potential (voltage) between multiple receiver electrodes. The DCR method provides subsurface information comparable to that produced by the CSEM method, but with less sophisticated instrumentation. Because the receivers are simple electrodes, large numbers can be deployed to achieve higher spatial resolution. In this project a prototype seafloor DCR system was developed and used to conduct a reconnaissance survey at a site of known hydrate occurrence in Mississippi Canyon Block 118. The resulting images of sub-bottom resistivities indicate that high-concentration hydrates at the site occur only in the upper 50 m, where deep-seated faults intersect the seafloor. Overall, there was evidence for much less hydrate at the site than previously thought based on available seismic and CSEM data alone.

03 NATURAL GAS↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗