Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Field Measurement Results of the 15 T Nb 3 Sn Dipole Demonstrator MDPCT1b

A 15 T Nb 3 Sn dipole with cos-theta-type coils was developed to demonstrate a possible magnet design for a post-LHC proton-proton Collider. The magnet has 4-layer coils with 60-mm aperture, and has graded current density between the inner and outer layers to maximize performance. The coils are constrained by vertically-split, thick iron laminations, connected by aluminum Iclamps, and a thick stainless-steel skin. The magnet was previously tested at the Vertical Magnet Test Facility (VMTF) at Fermilab with reduced pre-load, and achieved record 14.1 T fields at maximum current. Now the magnet has been reassembled with full pre-load and has been cryogenically retested at VMTF. We report here on the magnetic measurements results of these tests, including field strength, geometrical harmonics, coil magnetization, and iron saturation characteristics of the demonstrator.

43 PARTICLE ACCELERATORS↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GUIDELINES FOR THE DESIGN, FABRICATION, TESTING, INSTALLATION AND OPERATION OF SRF CAVITIES

Superconducting Radio-Frequency (SRF) cavities containing cryogens under pressure pose a potential rupture hazard to equipment and personnel. Generally, pressure vessels fall within the scope of the ASME Boiler and Pressure Vessel Code however, the use of niobium as a material for the SRF cavities is beyond the applicability of the Code. Fermilab developed a guideline to ensure sound engineering practices governing the design, fabrication, testing, installation and operation of SRF cavities. The objective of the guideline is to reduce hazards and to achieve an equivalent level of safety afforded by the ASME Code. The guideline addresses concerns specific to SRF cavities in the areas of materials, design and analysis, welding and brazing, pressure relieving requirements, pressure testing and quality control.

42 ENGINEERING↗

Proposal for GPD studies at COMPASS

The study of nucleon structure through Generalised Parton Distributions (GPD) is one major part of the future COMPASS-II physics program and can be performed using exclusive reactions like Deeply Virtual Compton Scattering (DVCS) and Meson Production. The high energy of the muon beam allows to measure the x{sub B}-dependence of the t-slope of the DVCS cross section. The use of positive and negative polarised muon beams allows to determine the Beam Charge and Spin Difference of the DVCS cross sections to access the real part of the Compton form factor related to the dominant GPD H. The sensitivity of both measurements is examined and confronted to existing models or global fits of the data. Preliminary beam test data were analyzed and demonstrated the feasibility of the identification of the DVCS reaction using the COMPASS experimental set-up.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photopion Physics at the HI{gamma}S Facility

Future photopion experiments at the HI{gamma}S facility are described. It is shown that they will provide accurate tests of ChPT and will be sensitive to isospin breaking dynamics due to the mass difference of the up and down quarks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasmonic Au nanoparticles embedding enhances the activity and stability of CdS for photocatalytic hydrogen evolution

A composite photocatalyst of embedding plasmonic Au nanoparticle into CdS (Au@CdS) was prepared with a cysteine-assisted hydrothermal approach. This structure could take fully advantage of electromagnetic fields at the surface of the Au nanoparticles under visible light illumination. The photocatalytic hydrogen evolution activity of CdS could be significantly improved. Without the use of any other metal or metal oxide as cocatalysts, the quantum efficiency can reach 12.1 % over 0.5%Au@CdS at 420 nm. When using 0.1%Pt as a cocatalyst, the quantum efficiency of 0.5%Au@CdS can be further improved to 45.6%. This efficiency can be maintained more than 100 h in the test 12 days, exhibiting a relatively high stability. Photoluminescence (PL) characterization shows that the formation rate of photoexcited e-/h+ was dramatically increased when Au nanoparticles were embedded into CdS. Time-resolved PL measurement shows that Au@CdS also has a longer luminescence lifetime than that of CdS, reflecting that the photoexcited electrons in Au@CdS be with much longer lifetime to reduce H+ forming H2. All these enhancements can be attributed to the effective energy transfer between the Au surface and CdS due to the well matched composite nanostructure. Dr. Xiang Wang gratefully acknowledges the US Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Chemical Sciences, Geosciences, and Biosciences Division for the support of this work.

Au nanoparticles↗

Diagnostics principle of microwave cut-off probe for measuring absolute electron density

A generalized diagnostics principle of microwave cut-off probe is presented with a full analytical solution. In previous studies on the microwave cut-off measurement of weakly ionized plasmas, the cut-off frequency ω{sub c} of a given electron density is assumed to be equal to the plasma frequency ω{sub p} and is predicted using electromagnetic simulation or electric circuit model analysis. However, for specific plasma conditions such as highly collisional plasma and a very narrow probe tip gap, it has been found that ω{sub c} and ω{sub p} are not equal. To resolve this problem, a generalized diagnostics principle is proposed by analytically solving the microwave cut-off condition Re[ε{sub r,eff}(ω = ω{sub c})] = 0. In addition, characteristics of the microwave cut-off condition are theoretically tested for correct measurement of the absolute electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-JeP1-05: Clinical Impact of MLC Tracking for Lung SABR

Purpose: The objective of this study was to investigate the dosimetric benefits of multi-leaf collimator (MLC) tracking for lung SABR treatments in end-to-end clinically realistic planning and delivery scenarios. Methods: The clinical benefits of MLC tracking were assessed using previously delivered treatment plans and physical experiments. The 10 most recent single lesion lung SABR patients were re-planned following a 4D-GTV-based real-time adaptive protocol (PTV defined as the end-of-exhalation GTV plus 5.0 mm margins). The plans were delivered on a Trilogy Varian linac. Electromagnetic transponders (Calypso, Varian Medical Systems, USA) were embedded into a programmable moving phantom (HexaMotion platform) tracked with the Varian Calypso system. For each physical experiment, the MLC positions were collected and used as input for dose reconstruction. For both planned and physical experiments, the OAR dose metrics from the conventional and real-time adaptive SABR plans (Mean Lung Dose (MLD), V20 for lung, and near-maximum dose (D2%) for spine and heart) were statistically compared. The Wilcoxon test was used to compare plan and physical experiment dose metrics. Results: While maintaining target coverage, percentage reductions in dose metrics to the OARs were observed for both planned and physical experiments. Comparing the two plans showed MLD percentage reduction (MLDr) of 25.4% (absolute differences of 1.41 Gy) and 28.9% (1.29%) for the V20r. D2% percentage reduction for spine and heart were respectively 27.9% (0.3 Gy) and 20.2% (0.3 Gy). For the physical experiments, MLDr was 23.9% (1.3 Gy), and V20r 37.4% (1.6%). D2% reduction for spine and heart were respectively 27.3% (0.3 Gy) and 19.6% (0.3 Gy). For both plans and physical experiments, significant OAR dose differences (p<0.05) were found between the conventional SABR and real-time adaptive plans. Conclusion: Application of MLC tracking for lung SABR patients has the potential to reduce the dose to OARs during radiation therapy.

60 APPLIED LIFE SCIENCES↗

Modeling Astrophysical Explosions and the Nucleosynthesis of the Heavy Elements

The heavier elements in the Universe were created and dispersed in the supernova explosions of stars. These events involve a fascinating interplay of nuclear physics, gravity, hydrodynamics, neutrino and photon transport, and radioactive decay, all occurring under extreme conditions. Astronomical experiments provide a rich and constraining data set, but our theoretical understanding of supernovae remains incomplete. The goal of this project is to advance numerical models of astrophysical explosions and use them to connect the nuclear theory of supernovae to current observational and experimental programs. Our contributions focus on one important aspect of the problem --modeling the transport of radiation (both neutrino and electromagnetic) which is essential to understanding the supernova explosion mechanism, the resulting nucleosynthesis, and the observable spectra and light curves. We will exploit recent advances in high performance computing to improve 3-dimensional simulations of core collapse supernovae and neutron star mergers. The benefits include: 1) Further defining the explosive astrophysical environments that govern the nucleosynthesis of r-process nuclei. 2) Preparing the way for more realistic treatments of neutrino interactions, with the ultimate goal of making supernovae a testing ground for probing fundamental neutrino physics, e.g., unknown mixing angles and new aspects of the MSW mechanism. 3) Providing a means for testing explosion simulations and nucleosynthesis calculations against data from optical and x-ray telescopes, thereby permitting the experimental validation or falsification of supernova models. 4) Helping position nuclear physics, through the development of new algorithms of the type incorporated in our simulation codes, to play a leading role in DOE large scale computing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulating the filamentation of smoothed laser beams with three-dimensional nonlinear dynamics

In a plasma, the ponderomotive force of an inhomogeneous electromagnetic field expels plasma from regions of high intensity. When a laser propagates through a plasma, this force creates density wells that subsequently modify the index of refraction. The beam refracts and focuses into these wells and may filament. In extreme cases, the laser beam will spray due to increasing angular divergence of the beam. The threshold for ponderomotive self-focusing is well established for isolated laser hotspots or speckles. Here, we define a practical threshold for characterizing the filamentation of thousands of speckles that are found in the focal plane of high-power laser beams spatially smoothed with random phase plates as used at high energy and power laser facilities studying inertial confinement fusion. This threshold is tested against three-dimensional simulations of speckled laser light propagating through plasma. Four metrics are applied to assess filamentation: the fraction of power above five times the average intensity, an effective f-number, the mean-squared perpendicular wavenumber, and the fraction of rarefied density with deviation from the initial density exceeding | δn/ n| = 0.1. The speckled beams studied are generated by random phase plates, both with and without additional polarization smoothing, in a parameter regime of relevance to indirect drive experiments. While filamentation has been discussed extensively in the literature, we believe this to be the first published simulation study with three-dimensional nonlinear hydrodynamics that addresses the onset threshold of ponderomotive filamentation and establishes the lengths and time scales necessary to reach a statistical steady state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A fine-focusing x-ray source using carbon-nanofiber field emitter

A fine-focusing x-ray source has been constructed employing a field electron emitter prepared by growing carbon-nanofibers (CNFs) on a metal tip. The x-ray source is composed of a CNF field electron emitter, an electrostatic lens, two magnetic lenses, and a W-target for generating x-rays by electron impact. The CNFs provided field electrons with a current density of J{approx}5x10{sup 9} A/m{sup 2}, which was evaluated with the aid of Fowler-Nordheim theory. The electron beam extracted from the CNF emitter was accelerated to the energies of E=10-25 keV, and then focused by the lenses. By recording the x-ray images of test charts, the optimum resolution of the x-ray source was estimated to be approximately D{sub x}=0.5 {mu}m.

07 ISOTOPE AND RADIATION SOURCES↗

Photoemission Studies of Metallic Photocathodes Prepared by Pulsed Laser Ablation Deposition Technique

We present the results of our investigation on metallic films as suitable photocathodes for the production of intense electron beams in RF photoinjector guns. Pulsed laser ablation deposition technique was used for growing Mg and Y thin films onto Si and Cu substrates in high vacuum and at room temperature.Different diagnostic methods were used to characterize the thin films deposited on Si with the aim to optimize the deposition process. Photoelectron performances were investigated on samples deposited on Cu substrate in an ultra high vacuum photodiode chamber at 10{sup -7} Pa. Relatively high quantum efficiencies have been obtained for the deposited films, comparable to those of corresponding bulks. Samples could stay for several months in humid open air before being tested in a photodiode cell. The deposition process and the role of the photocathode surface contamination and its influence on the photoelectron performances are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soft magnetic properties of (Ni{sub 80}Fe{sub 20}){sub 1-x}(Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4}){sub x} films for high frequency applications

A series of (Ni{sub 80}Fe{sub 20}){sub 1-x}(Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4}){sub x} films were fabricated on Si substrates by means of radio frequency magnetron sputtering and the electrical and magnetic properties were studied. Optimal films with the desired properties of low coercivity H{sub c} {approx} 4 Oe, high saturation magnetization 4{pi}Ms {approx} 14.5 kG, and high electrical resistivity {rho} {approx} 1500 {mu}{Omega} cm were obtained. The permeability spectra measured shows that its natural ferromagnetic resonant frequency was about 3.4 GHz. The tested results shown that the sputtering power had an important effect on the films properties and that it can be convenient to adjust the natural ferromagnetic resonant frequency of the films.

36 MATERIALS SCIENCE↗

The Tianlai dish pathfinder array: design, operation, and performance of a prototype transit radio interferometer

ABSTRACT The Tianlai Dish Pathfinder Array is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization universe as a means for measuring large-scale cosmic structure. It performs drift scans of the sky at constant declination. We describe the design, calibration, noise level, and stability of this instrument based on the analysis of about 5% of 6200 h of on-sky observations through 2019 October. Beam pattern determinations using drones and the transit of bright sources are in good agreement, and compatible with electromagnetic simulations. Combining all the baselines, we make maps around bright sources and show that the array behaves as expected. A few hundred hours of observations at different declinations have been used to study the array geometry and pointing imperfections, as well as the instrument noise behaviour. We show that the system temperature is below 80 K for most feed antennas and that noise fluctuations decrease as expected with integration time, at least up to a few hundred seconds. Analysis of long integrations, from 10 nights of observations of the North Celestial Pole (NCP), yielded visibilities with amplitudes of 20–30 mK, consistent with the expected signal from the NCP radio sky with ${\lt}10\,$ mK precision for 1 MHz × 1 min binning. Hi-pass filtering the spectra to remove smooth spectrum signal yields a residual consistent with zero signal at the $0.5\,$ mK level.

(cosmology:) large-scale structure of the Universe↗

Optimal Transport for e/$\pi^0$ Particle Classification in LArTPC Neutrino Experiments

Separation of electron signals from $\pi^0$ backgrounds is crucial for neutrino oscillation measurements and searches for Beyond Standard Model (BSM) physics in current and future Liquid Argon Time Projection Chamber (LArTPC) experiments. e/$\pi^0$ separation has been a reconstruction challenge since both e and $\pi^0$ present as electromagnetic showers, and often only one out of the two showers produced by $\pi^0$ is reconstructed correctly. This research aims to improve the performance of e/$\pi^0$ separation using optimal transport (OT), by leveraging on the topological differences in the showers produced by the two particles. OT is a method which compares two distributions by finding the most efficient way to transform, or “move” from one to the other. This work uses the MicroBooNE open samples public dataset to test the e/$\pi^0$ separation performance of the method on events which incorporate realistic modeling of LArTPC detector response. Reconstructed 3D energy deposits are projected onto a plane perpendicular to the primary shower, allowing OT to better detect the topological differences between the two types of particles without the need to separately reconstruct all the showers in the events. Different distance metrics for OT are tested and preliminary results on e/$\pi^0$ separation are presented.

43 PARTICLE ACCELERATORS↗

Progress in Monitoring Strategies for Risk Reduction in Geologic CO2 Storage

Abstract: This geophysical monitoring review is intended to lay the ground work for an approach to integrating monitoring strategies with risk assessment and risk reduction and to summarize work conducted by U.S. Department of Energy's National Risk Assessment Partnership (NRAP) participants that addresses key questions related to monitoring strategies. Commercial, demonstration and pilot geologic CO2 storage (GCS) projects have provided a wealth of practical experience in monitoring technologies. In this manuscript we review a few key projects, specific geophysical methods, well-based methods, geophysical workflows and some suggested best practices. These practices are often driven and governed by regulatory requirements (e.g. U.S. Environmental Protection Agency [US-EPA] Class VI underground injection regulation) and the need for effective reservoir management of pressures and volumes as well as the site-specific risks to containment, plume migration, and underground sources of drinking water. Reducing uncertainty in monitoring is likely to lead to reducing uncertainty in risk. One of our conclusions is the need for field experiment testing that is risk-driven. It is notable that GCS pilot projects have been designed for safe storage, and to date they have been successful. Technical challenges at all geologic CO2 storage sites include assuring injectivity and capacity predictions are reliable, the fate and subsurface topology of the CO2 plume is acceptable, regulatory permitting and compliance are accomplished in a timely manner, needed business assurances are supported by quantitative technical data, and the storage operation is acceptable to stakeholders. There is risk associated with all of these challenges necessitating a monitoring program utilizing both direct and indirect monitoring methods. Because of the direct association of risk and monitoring in GCS, geophysical monitoring is viewed as a key component in approaching risk assessment. To address monitoring in the context of risk assessment the U.S. Department of Energy's National Risk Assessment Partnership (NRAP) has undertaken a review of work related to monitoring storage sites. In this review we provide a framework for monitoring and then present some specific monitoring tools that may be useful for regulatory compliance, as well as technologies that are applicable to leakage detection.

Harbert, William↗

I. Final Report for DOE SBIR Phase I Project DE-SC0013795 Final Report for DOE SBIR Phase I Project DE-SC0013795 Microtron-based Compact, Portable Gamma-Ray Source

Microtron-based Compact, Portable Gamma-Ray Source. The objective of Phase I of this project was to produce a conceptual design of a prototype compact microtron electron accelerator, which could be designed, built, and demonstrated in Phase II of the project. The conceptual design study included an analysis of the parameters of the microtron and its components, and the expected performance of the prototype microtron as a source of x-rays and/or RF neutrons in the MeV energy range. The major components of the microtron are the magnet, the accelerating system, the power system, the vacuum system, the control system, the beam extraction system and the targets to produce x-rays (and/or neutrons). Our objectives for the design of the prototype were for it to be compact, cost-effective, capable of producing high intensity x-ray (an/or neutron) fluxes. In addition, the prototype was to be easily assembled and disassembled so that components could be easily replaced. The main parameters for the prototype are the following: the range of electron kinetic energies, the output power, the RF frequency band (X-band, C-band, or S-Band), the type of injection (Type I or Type II), the magnet type, i.e. permanent magnet, electromagnet, or a hybrid combination of permanent and electromagnet. The results of the Phase I study and analysis for a prototype microtron are the following: The electron energy range can be varied from below 6 MeV to 9 MeV, the optimal frequency range is S-Band (2-4 GHz) RF frequency, Type II injection (described below), and the magnet type is the hybrid version. The prototype version will be capable of producing gamma ray doses of ~1800 R/min-m and neutron fluxes of up to ~6 x 10 10 n/s with appropriate targets. The results of the Phase I study and analysis are provided below. The proposed Phase II plan was to demonstrate the prototype at low beam power. In the subsequent Phase III, high power tests would be performed, and the design of commercial versions of microtrons with various energies, sizes and types would be produced and marketed, including a more compact and more portable 6 MeV battery-powered model that more closely meets the requirements in the original FOA topic description. In the course of the Phase I study, we also identified another microtron version, one that was larger (not compact) and more powerful than that of the Phase II prototype, which could serve as an intense source of photo- neutrons, up to 4 x 10 12 n/s for use in nuclear medicine, short-lived isotope production, or other applications. In addition, it could produce gamma dose rates up to 130 kR/min-m with a heavy metal bremsstrahlung target. The results and specifications of this were submitted to IPAC16 (Reference [12]) the paper is included in Addendum B. Because this version was beyond the scope of the Phase I project, there is no additional description in the Final Report.

43 PARTICLE ACCELERATORS↗

Diffractive PDF fits and factorisation tests at HERA

A DGLAP next-to-leading-order QCD analysis to extract the diffractive parton distribution functions, using DIS inclusive and dijet diffractive HERA data, is presented. Predictions based on the extracted parton densities are compared to diffractive dijet photoproduction data to discuss factorisation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗