Search NASA⌕ Search

SEARCH · Search NASA

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

On the occurrence of fast neutrino flavor conversions in multidimensional supernova models

The dense neutrino medium in a core-collapse supernova or a neutron-star merger event can experience fast flavor conversions on time/distance scales that are much smaller than those of vacuum oscillations. It is believed that fast neutrino flavor transformation occurs in the region where the angular distributions of ν e and v¯ e cross each other. We present the first study of this crossing phenomenon and the fast neutrino flavor conversions in multidimensional (multi-D) supernova models. We examine the neutrino distributions obtained by solving the Boltzmann transport equation for several fixed profiles which are representative snapshots taken from separate 2D and 3D supernova simulations with an 11.2 M ⊙ progenitor model. Our research shows that the spherically asymmetric patterns of the ν e and v¯ e fluxes in multi-D models can assist the appearance of the crossing between the ν e and v¯ e angular distributions. In the models that we have studied, there exist unstable neutrino oscillation modes in and beyond the neutrino decoupling region which have amplitude growth rates as large as an e-fold per nanosecond. Here, this finding can have important consequences for the explosion mechanism, nucleosynthesis, and neutrino signals of core-collapse supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

Entanglement and correlations in fast collective neutrino flavor oscillations

Collective neutrino oscillations play a crucial role in transporting lepton flavor in astrophysical settings like supernovae and neutron star binary merger remnants, which are characterized by large neutrino densities. In these settings, simulations in the mean-field approximation show that neutrino-neutrino interactions can overtake vacuum oscillations and give rise to fast collective flavor evolution on time-scales t ∝ μ –1 , with μ proportional to the local neutrino density. In this work, we study the full out-of-equilibrium flavor dynamics in simple multi-angle geometries displaying fast oscillations in the mean field linear stability analysis. Focusing on simple initial conditions, we analyze the production of pair correlations and entanglement in the complete many-body-dynamics as a function of the number N of neutrinos in the system, for up to thousands of neutrinos. Similarly to simpler geometries with only two neutrino beams, we identify three regimes: stable configurations with vanishing flavor oscillations, marginally unstable configurations with evolution occurring on long time scales τ ≈ µ –1 $\sqrt{N}$, and unstable configurations showing flavor evolution on short time scales τ ≈ μ –1 log(N). Here, we present evidence that these fast collective modes are generated by the same dynamical phase transition which leads to the slow bipolar oscillations, establishing a connection between these two phenomena and explaining the difference in their time scales. We conclude by discussing a semi-classical approximation which reproduces the entanglement entropy at short to medium time scales and can be potentially useful in situations with more complicated geometries where classical simulation methods starts to become inefficient.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deterministic Fast Scrambling with Neutral Atom Arrays

Fast scramblers are dynamical quantum systems that produce many-body entanglement on a timescale that grows logarithmically with the system size N. Here, we propose and investigate a family of deterministic, fast scrambling quantum circuits realizable in near-term experiments with arrays of neutral atoms. We show that three experimental tools—nearest-neighbor Rydberg interactions, global single-qubit rotations, and shuffling operations facilitated by an auxiliary tweezer array—are sufficient to generate nonlocal interaction graphs capable of scrambling quantum information using only O(logN) parallel applications of nearest-neighbor gates. These tools enable direct experimental access to fast scrambling dynamics in a highly controlled and programmable way and can be harnessed to produce highly entangled states with varied applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Visualization of Fast Ion Phase-Space Flow Driven by Alfvén Instabilities

Fast ion phase-space flow, driven by Alfven eigenmodes (AEs), is measured by an imaging neutral particle analyzer in the DIII-D tokamak. The flow firstly appears near the minimum safety factor at the injection energy of neutral beams, and then moves radially inward and outward by gaining and losing energy, respectively. The flow trajectories in phase space align well with the intersection lines of the constant magnetic moment surfaces and constant E – (ω/n)P ζ surfaces, where E, P ζ are energy and toroidal canonical momentum of ions; ω and n are angular frequencies and toroidal mode numbers of AEs. It is found that the flow is so destructive that the thermalization of fast ions is no longer observed in regions of strong interaction. Here, the measured phase-space flow is consistent with nonlinear hybrid kinetic-magnetohydrodynamics simulation. Calculations of the relatively narrow phase-space islands reveal that fast ions must transition between different flow trajectories to experience large-scale phase-space transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed electron beam generation with fast repetitive double pulse system

Longer duration high voltage pulse (∼ 100 kV, 260 ns) is generated and reported using helical pulse forming line in compact geometry. The transmission line characteristics of the helical pulse forming line are also used to develop fast repetition double pulse system with very short inter pulse interval. It overcomes the limitations caused due to circuit parameters, power supplies and load characteristics for fast repetitive high voltage pulse generation. The high voltage double pulse of 100 kV, 100 ns with an inter pulse repetition interval of 30 ns is applied across the vacuum field emission diode for pulsed electron beam generation. The electron beam is generated from cathode material by application of negative high voltage (> 100 kV) across the diode by explosive electron emission process. The vacuum field emission diode is made of 40 mm diameter graphite cathode and SS mesh anode. The anode cathode gap was 6 mm and the drift tube diameter was 10 cm. The initial experimental results of pulsed electron beam generation with fast repetitive double pulse system are reported and discussed. (author)

43 PARTICLE ACCELERATORS↗

Design and Optimization of a Fast-Switching Electromagnetic Valve Actuator for Off-highway Vehicle Hydraulic Systems

Electrification of off-highway vehicles offers improved efficiency and reduction in greenhouse gas emissions. However, the extremely low power densities of electric machines relative to the hydraulics used in conventional off-highway vehicles makes electrification challenging. Although the recently proposed Hybrid Hydraulic Electric Architecture (HHEA) can overcome this limitation, it requires frequent switching between the pressure rails using switching valves resulting in losses. Fast switching minimizes the switching losses in these valves, which otherwise significantly reduce the overall efficiency of the system. The primary contribution of this paper is the design and optimization of a linear electromagnetic actuator for a fast-switching valve. This paper identifies the actuator requirements to enable fast switching and presents a design and optimization technique to realize actuators that meet the design objectives. In addition, a multi-physics approach is proposed to model the performance of the complete switching valve by considering the electromagnetic, fluidic, and mechanical physics. An optimal actuator design is obtained using the developed optimization framework, and the multi-physics model demonstrates that the selected design achieves a 30% reduction in throttling-related switching losses by switching 70 % faster than comparable commercial valve designs.

Linear actuators, off-highway vehicle electrificat↗

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

Asynchronous Grid Connections Providing Fast-Frequency Response: System Integration Study

This paper presents an integration study for the recent power electronic-based fast-frequency response technology, "asynchronous grid connection" which operates as an aggregator for behind-the-meter resources and distributed generators. Both technical feasibility and techno-economic viability studies are presented. The fast-frequency response characteristics, validated against Power Hardware-in-the-Loop experiments, are integrated into an IEEE 9- bus system in DigSilent PowerFactory for system-level dynamic analysis. It demonstrates that droop-based control enhancements to local distributed generators allow their aggregation to provide grid-supporting functionalities and participate in the ancillary service markets. To this end, a long-term simulation embedding the system within the ancillary service market framework of PJM has been performed. The fast-frequency response regulation is subsequently used to calculate the potential revenue and project the results on a 15-year investment horizon. Finally, the techno-economic analysis provides recommendations for enhancements to access the full potential of distributed generators on a technical and regulatory level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast transit portal dosimetry using density-scaled layer modeling of aSi-based electronic portal imaging device and Monte Carlo method

Purpose: Fast and accurate transit portal dosimetry was investigated by developing a density-scaled layer model of electronic portal imaging device (EPID) and applying it to a clinical environment. Methods: The model was developed for fast Monte Carlo dose calculation. The model was validated through comparison with measurements of dose on EPID using first open beams of varying field sizes under a 20-cm-thick flat phantom. After this basic validation, the model was further tested by applying it to transit dosimetry and dose reconstruction that employed our predetermined dose-response-based algorithm developed earlier. The application employed clinical intensity-modulated beams irradiated on a Rando phantom. The clinical beams were obtained through planning on pelvic regions of the Rando phantom simulating prostate and large pelvis intensity modulated radiation therapy. To enhance agreement between calculations and measurements of dose near penumbral regions, convolution conversion of acquired EPID images was alternatively used. In addition, thickness-dependent image-to-dose calibration factors were generated through measurements of image and calculations of dose in EPID through flat phantoms of various thicknesses. The factors were used to convert acquired images in EPID into dose. Results: For open beam measurements, the model showed agreement with measurements in dose difference better than 2% across open fields. For tests with a Rando phantom, the transit dosimetry measurements were compared with forwardly calculated doses in EPID showing gamma pass rates between 90.8% and 98.8% given 4.5 mm distance-to-agreement (DTA) and 3% dose difference (DD) for all individual beams tried in this study. The reconstructed dose in the phantom was compared with forwardly calculated doses showing pass rates between 93.3% and 100% in isocentric perpendicular planes to the beam direction given 3 mm DTA and 3% DD for all beams. On isocentric axial planes, the pass rates varied between 95.8% and 99.9% for all individual beams and they were 98.2% and 99.9% for the composite beams of the small and large pelvis cases, respectively. Three-dimensional gamma pass rates were 99.0% and 96.4% for the small and large pelvis cases, respectively. Conclusions: The layer model of EPID built for Monte Carlo calculations offered fast (less than 1 min) and accurate calculation for transit dosimety and dose reconstruction.

60 APPLIED LIFE SCIENCES↗

TH-A-19A-08: Intel Xeon Phi Implementation of a Fast Multi-Purpose Monte Carlo Simulation for Proton Therapy

Purpose: Recent studies have demonstrated the capability of graphics processing units (GPUs) to compute dose distributions using Monte Carlo (MC) methods within clinical time constraints. However, GPUs have a rigid vectorial architecture that favors the implementation of simplified particle transport algorithms, adapted to specific tasks. Our new, fast, and multipurpose MC code, named MCsquare, runs on Intel Xeon Phi coprocessors. This technology offers 60 independent cores, and therefore more flexibility to implement fast and yet generic MC functionalities, such as prompt gamma simulations. Methods: MCsquare implements several models and hence allows users to make their own tradeoff between speed and accuracy. A 200 MeV proton beam is simulated in a heterogeneous phantom using Geant4 and two configurations of MCsquare. The first one is the most conservative and accurate. The method of fictitious interactions handles the interfaces and secondary charged particles emitted in nuclear interactions are fully simulated. The second, faster configuration simplifies interface crossings and simulates only secondary protons after nuclear interaction events. Integral depth-dose and transversal profiles are compared to those of Geant4. Moreover, the production profile of prompt gammas is compared to PENH results. Results: Integral depth dose and transversal profiles computed by MCsquare and Geant4 are within 3%. The production of secondaries from nuclear interactions is slightly inaccurate at interfaces for the fastest configuration of MCsquare but this is unlikely to have any clinical impact. The computation time varies between 90 seconds for the most conservative settings to merely 59 seconds in the fastest configuration. Finally prompt gamma profiles are also in very good agreement with PENH results. Conclusion: Our new, fast, and multi-purpose Monte Carlo code simulates prompt gammas and calculates dose distributions in less than a minute, which complies with clinical time constraints. It has been successfully validated with Geant4. This work has been financialy supported by InVivoIGT, a public/private partnership between UCL and IBA.

07 ISOTOPE AND RADIATION SOURCES↗

TH-A-19A-10: Fast Four Dimensional Monte Carlo Dose Computations for Proton Therapy of Lung Cancer

Purpose: To develop and validate a fast and accurate four dimensional (4D) Monte Carlo (MC) dose computation system for proton therapy of lung cancer and other thoracic and abdominal malignancies in which the delivered dose distributions can be affected by respiratory motion of the patient. Methods: A 4D computer tomography (CT) scan for a lung cancer patient treated with protons in our clinic was used to create a time dependent patient model using our in-house, MCNPX-based Monte Carlo system (“MC{sup 2}”). The beam line configurations for two passively scattered proton beams used in the actual treatment were extracted from the clinical treatment plan and a set of input files was created automatically using MC{sup 2}. A full MC simulation of the beam line was computed using MCNPX and a set of phase space files for each beam was collected at the distal surface of the range compensator. The particles from these phase space files were transported through the 10 voxelized patient models corresponding to the 10 phases of the breathing cycle in the 4DCT, using MCNPX and an accelerated (fast) MC code called “FDC”, developed by us and which is based on the track repeating algorithm. The accuracy of the fast algorithm was assessed by comparing the two time dependent dose distributions. Results: The error of less than 1% in 100% of the voxels in all phases of the breathing cycle was achieved using this method with a speedup of more than 1000 times. Conclusion: The proposed method, which uses full MC to simulate the beam line and the accelerated MC code FDC for the time consuming particle transport inside the complex, time dependent, geometry of the patient shows excellent accuracy together with an extraordinary speed.

60 APPLIED LIFE SCIENCES↗

TH-C-18A-12: Evaluation of the Impact of Body Size and Tube Output Limits in the Optimization of Fast Scanning with High-Pitch Dual Source CT

Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, and B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRD-07: Fast Monte Carlo-Based Biological Optimization of Proton Therapy Treatment Plans for Thyroid Tumors

Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) based biological planning for the treatment of thyroid tumors in spot-scanning proton therapy. Methods: Recently, we developed a fast and accurate GPU-based MC simulation of proton transport that was benchmarked against Geant4.9.6 and used as the dose calculation engine in a clinically-applicable GPU-accelerated IMPT optimizer. Besides dose, it can simultaneously score the dose-averaged LET (LETd), which makes fast biological dose (BD) estimates possible. To convert from LETd to BD, we used a linear relation based on cellular irradiation data. Given a thyroid patient with a 93cc tumor volume, we created a 2-field IMPT plan in Eclipse (Varian Medical Systems). This plan was re-calculated with our MC to obtain the BD distribution. A second 5-field plan was made with our in-house optimizer, using pre-generated MC dose and LETd maps. Constraints were placed to maintain the target dose to within 25% of the prescription, while maximizing the BD. The plan optimization and calculation of dose and LETd maps were performed on a GPU cluster. The conventional IMPT and biologically-optimized plans were compared. Results: The mean target physical and biological doses from our biologically-optimized plan were, respectively, 5% and 14% higher than those from the MC re-calculation of the IMPT plan. Dose sparing to critical structures in our plan was also improved. The biological optimization, including the initial dose and LETd map calculations, can be completed in a clinically viable time (∼30 minutes) on a cluster of 25 GPUs. Conclusion: Taking advantage of GPU acceleration, we created a MC-based, biologically optimized treatment plan for a thyroid patient. Compared to a standard IMPT plan, a 5% increase in the target’s physical dose resulted in ∼3 times as much increase in the BD. Biological planning was thus effective in escalating the target BD.

60 APPLIED LIFE SCIENCES↗

Fast automatic 3D liver segmentation based on a three-level AdaBoost-guided active shape model

Purpose: A robust, automatic, and rapid method for liver delineation is urgently needed for the diagnosis and treatment of liver disorders. Until now, the high variability in liver shape, local image artifacts, and the presence of tumors have complicated the development of automatic 3D liver segmentation. In this study, an automatic three-level AdaBoost-guided active shape model (ASM) is proposed for the segmentation of the liver based on enhanced computed tomography images in a robust and fast manner, with an emphasis on the detection of tumors. Methods: The AdaBoost voxel classifier and AdaBoost profile classifier were used to automatically guide three-level active shape modeling. In the first level of model initialization, fast automatic liver segmentation by an AdaBoost voxel classifier method is proposed. A shape model is then initialized by registration with the resulting rough segmentation. In the second level of active shape model fitting, a prior model based on the two-class AdaBoost profile classifier is proposed to identify the optimal surface. In the third level, a deformable simplex mesh with profile probability and curvature constraint as the external force is used to refine the shape fitting result. In total, three registration methods—3D similarity registration, probability atlas B-spline, and their proposed deformable closest point registration—are used to establish shape correspondence. Results: The proposed method was evaluated using three public challenge datasets: 3Dircadb1, SLIVER07, and Visceral Anatomy3. The results showed that our approach performs with promising efficiency, with an average of 35 s, and accuracy, with an average Dice similarity coefficient (DSC) of 0.94 ± 0.02, 0.96 ± 0.01, and 0.94 ± 0.02 for the 3Dircadb1, SLIVER07, and Anatomy3 training datasets, respectively. The DSC of the SLIVER07 testing and Anatomy3 unseen testing datasets were 0.964 and 0.933, respectively. Conclusions: The proposed automatic approach achieves robust, accurate, and fast liver segmentation for 3D CTce datasets. The AdaBoost voxel classifier can detect liver area quickly without errors and provides sufficient liver shape information for model initialization. The AdaBoost profile classifier achieves sufficient accuracy and greatly decreases segmentation time. These results show that the proposed segmentation method achieves a level of accuracy comparable to that of state-of-the-art automatic methods based on ASM.

60 APPLIED LIFE SCIENCES↗

Experimental investigations of fast-proton production in a picosecond laser plasma

Results of experimental investigations of fast-proton production in a laser plasma are presented for the case where the intensity of laser radiation at the targets is 2 x 10{sup 18} W/cm{sup 2}. Three processes of fast-proton acceleration in laser plasma are investigated: (1) the acceleration of protons from the front surface toward the laser pulse, (ii) the acceleration of protons from the front surface of the target toward its interior, and (iii) the acceleration of protons from the rear foil surface in the outward direction. The activation procedure and CR-39 tracker detectors featuring a set of various-thickness aluminum filters were used to record fast protons. It turned out that the proton-acceleration process is the most efficient in the case of proton acceleration from the rear foil surface in the outward direction. Experimental results revealed that about N{sub p} = 10{sup 7} protons of energy in the region E{sub p} > 1.9 MeV that are accelerated from the target surface toward a laser ray, N{sub p} = 4x 10{sup 7} protons of energy in the region E{sub p} > 1.9 MeV that are accelerated fromthe front surface of the target toward its interior, and N{sub p} = 4x10{sup 8} protons of energy in the region E{sub p} > 1.9 MeV that are accelerated from the rear foil surface in the outward direction are generated at a laser-radiation intensity of 2 x 10{sup 18} W/cm{sup 2} at the surface of aluminum, copper, and titanium targets. Experimental investigations aimed at optimizing the process of proton acceleration from the rear surface of aluminum foils were performed by varying the foil thickness over the range between 1 and 100 {mu}m. The results of these experiments showed that there is an optimum foil thickness of 10 {mu}m, in which case protons of maximum energy 5 MeV are generated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Parameters of an ion beam and characteristic features of its slowing-down in a plasma during fast ignition of an inertial fusion target

The physics of the heating of an inertial fusion target by a high-energy ion beam under the conditions of fast ignition of fusion reactions is studied theoretically. The characteristic features of the formation of the spatial distribution of the energy transferred to the plasma from a beam of ions with different initial energies, masses, and charges under fast ignition conditions are determined. The notion of the Bragg peak is extended with respect to the spatial distribution of the temperature of the ion-beam-heated medium. The parameters of the ion beams are determined with which to initiate different regimes of fast ignition of a thermonuclear fuel precompressed to a density of 300-500 g/cm{sup 3}-the edge regime, in which the ignition region is formed at the outer boundary of the target, and the internal regime, in which the ignition region is formed within the target and, in particular, in its central parts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and theoretical studies of the spatial distribution of the ionization rate in a non-self-sustained discharge controlled by a fast electron beam

The spatial distribution of the current density of fast electrons and the ionization rate in a gap filled with atmospheric-pressure air under the conditions of a non-self-sustained discharge controlled by a fast electron beam were investigated. The experiments were carried out in a gas-discharge chamber with a grid electrode arranged in parallel to the exit window of the ionization source. Spatial variations in the current density of fast electrons resulting from the grid were measured. The propagation of the electron beam through the discharge system was simulated numerically by the Monte Carlo method in the so-called 'effective collision' approximation. The calculated results agree well with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beams of fast neutral atoms and molecules in low-pressure gas-discharge plasma

Fast neutral atom and molecule beams have been studied, the beams being produced in a vacuum chamber at nitrogen, argon, or helium pressure of 0.1-10 Pa due to charge-exchange collisions of ions accelerated in the sheath between the glow discharge plasma and a negative grid immersed therein. From a flat grid, two broad beams of molecules with continuous distribution of their energy from zero up to e(U + U{sub c}) (where U is voltage between the grid and the vacuum chamber and U{sub c} is cathode fall of the discharge) are propagating in opposite directions. The beam propagating from the concave surface of a 0.2-m-diameter grid is focused within a 10-mm-diameter spot on the target surface. When a 0.2-m-diameter 0.2-m-high cylindrical grid covered by end disks and composed of parallel 1.5-mm-diameter knitting needles spaced by 4.5 mm is immersed in the plasma, the accelerated ions pass through the gaps between the needles, turn inside the grid into fast atoms or molecules, and escape from the grid through the gaps on its opposite side. The Doppler shift of spectral lines allows for measuring the fast atom energy, which corresponds to the potential difference between the plasma inside the chamber and the plasma produced as a result of charge-exchange collisions inside the cylindrical grid.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗