Developing extensible lattice-Boltzmann simulators for general-purpose graphics-processing units

Lattice-Boltzmann methods are versatile numerical modeling techniques capable of reproducing a wide variety of fluid-mechanical behavior. These methods are well suited to parallel implementation, particularly on the single-instruction multiple data (SIMD) parallel processing environments found in computer graphics processing units (GPUs). Although more recent programming tools dramatically improve the ease with which GPU programs can be written, the programming environment still lacks the flexibility available to more traditional CPU programs. In particular, it may be difficult to develop modular and extensible programs that require variable on-device functionality with current GPU architectures. This paper describes a process of automatic code generation that overcomes these difficulties for lattice-Boltzmann simulations. It details the development of GPU-based modules for an extensible lattice-Boltzmann simulation package - LBHydra. The performance of the automatically generated code is compared to equivalent purpose written codes for both single-phase, multiple-phase, and multiple-component flows. The flexibility of the new method is demonstrated by simulating a rising, dissolving droplet in a porous medium with user generated lattice-Boltzmann models and subroutines.

97 MATHEMATICS AND COMPUTING↗

Developing extensible lattice-Boltzmann simulationsfor general-purpose graphics-programming units

Lattice-Boltzmann methods are versatile numerical modeling techniques capable of reproducing a wide variety of fluid-mechanical behavior. These methods are well suited to parallel implementation, particularly on the single-instruction multiple data (SIMD) parallel processing environments found in computer graphics processing units (GPUs). Although more recent programming tools dramatically improve the ease with which GPU programs can be written, the programming environment still lacks the flexibility available to more traditional CPU programs. In particular, it may be difficult to develop modular and extensible programs that require variable on-device functionality with current GPU architectures. This paper describes a process of automatic code generation that overcomes these difficulties for lattice-Boltzmann simulations. It details the development of GPU-based modules for an extensible lattice-Boltzmann simulation package - LBHydra. The performance of the automatically generated code is compared to equivalent purpose written codes for both single-phase, multiple-phase, and multiple-component flows. The flexibility of the new method is demonstrated by simulating a rising, dissolving droplet in a porous medium with user generated lattice-Boltzmann models and subroutines.

97 MATHEMATICS AND COMPUTING↗

THE SECOND STAGE OF FERMI@ELETTRA: A SEEDED FEL IN THE SOFT X-RAY SPECTRAL RANGE

The second stage of the FERMI FEL, named FEL-2, is based on the principle of high-gain harmonic generation and relies on a double-seeded cascade. Recent developments stimulated a revision of the original setup, which was designed to cover the spectral range between 40 and 10 nm. The numerical simulations we present here show that the nominal (expected) electron-beam performance allows extension of the FEL spectral range down to 4 nm. A significant amount of third harmonic power can be also expected. We also show that the proposed setup is flexible enough for exploiting future developments of new seed sources, e.g., high harmonic generation in gases.

43 PARTICLE ACCELERATORS↗

What Is the Value of Alternative Methods for Estimating Ramping Needs?

Power system operators procure and deploy flexibility reserves or ramping products to address balancing needs caused by uncertainty and variability of load and generation. Existing methods estimate ramping needs using calendar information and historical forecast errors. Novel methods investigate if real-time weather information could inform ramping and other balancing requirements. This paper compares estimation methods for ramping requirements in theory and practice. The theoretical framework indicates when an alternative method could yield improved economic or reliability performance than existing methods by requiring lower or higher levels of ramping products. Preliminary simulations on a 118-bus test system for 4 days in May 2019 illustrate how system performance improves or deteriorates when ramping requirements are weather-informed (alternative) instead of calendar-based (baseline). Preliminary results suggest high variability in change of performance and underline the impact of additional factors, such as system conditions, on the realized performance change.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Flexible $I_{Q}\!\!-\!\!V$ Scheme of a DFIG for Rapid Voltage Regulation of a Wind Power Plant

This paper proposes a flexible reactive current-to-voltage (I Q -V) scheme of a doubly-fed induction generator (DFIG) for the rapid voltage regulation of a wind power plant (WPP). In the proposed scheme, the WPP controller dispatches different voltage set points to the DFIGs depending on their rotor voltage margins. The DFIGs inject different reactive power with the flexible I Q -V schemes implemented in the rotor-side and grid-side converters. The I Q -V characteristic, which consists of the gain and width of a linear band and I Q capability, varies with time depending on the I Q capability of the converters and a voltage dip at the point of interconnection (POI). To increase the I Q capability during a fault, the active current is reduced in proportion to a voltage dip. If the I Q capability and/or the POI voltage dip are large, the I Q -V gain is set to be high, thereby providing rapid voltage regulation. To avoid an overvoltage after the fault clearance, a rapid I Q reduction scheme is implemented in the WPP and DFIG controllers. The performance of the proposed flexible scheme was verified under scenarios with various disturbances. In conclusion, the proposed scheme can help increase wind power penetration without jeopardizing voltage stability.

17 WIND ENERGY↗

Rapid and Energy‐Efficient Synthesis of Disordered Rocksalt Cathodes

Abstract Lithium‐rich transition metal oxides with a cation‐disordered rocksalt structure (disordered rocksalt oxides or DRX) are promising candidates for sustainable, next‐generation Li‐ion cathodes due to their high energy densities and compositional flexibility, enabling Co‐ and Ni‐free battery chemistries. However, current methods to synthesize DRX compounds require either high temperature (≈1000 °C) sintering for several hours, or high energy ball milling for several days in an inert atmosphere. Both methods are time‐ and energy‐intensive, limiting the scale up of DRX production. The present study reports the rapid synthesis of various DRX compositions in ambient air via a microwave‐assisted solid‐state technique resulting in reaction times as short as 5 min, which are more than two orders of magnitude faster than current synthesis methods. The DRX compounds synthesized via microwave are phase‐pure and have a similar short‐ and long‐range structure as compared to DRX materials synthesized via a standard solid‐state route, resulting in nearly identical electrochemical performance. In some cases, microwave heating allows for better particle size and morphology control. Overall, the rapid and energy‐efficient microwave technique provides a more sustainable route to produce DRX materials, further incentivizes the development of next‐generation DRX cathodes, and is key to accelerating their optimization via high‐throughput studies.

25 ENERGY STORAGE↗

Water transport properties of virtual fractal porous media: Implications for the unsaturated transport properties of cement-based materials

Cement-based materials are more and more recognized as fractal materials. From a practical point of view, fractality means that the pore size distribution can be described using fractal scaling law (i.e. power functions). Here, the simplest scaling law making use of a single fractal dimension was used to generate simple and virtual fractal porous media (based on bundles of parallel cylindrical pores). The capillary curve and permeability (relative and intrinsic) of the virtual porous media were then estimated through theoretical and numerical approaches. The results show that: (1) although bereft of any physical basis, van Genuchten equation bears some fractal information; (2) although highly flexible, van Genuchten equation fails to perfectly fit the capillary curves and can thus generate error in inverse analysis (for intrinsic permeability evaluation) and (3) there seems to be a relation between the intrinsic permeability and van Genuchten pressure parameter.

36 MATERIALS SCIENCE↗

Economic Assessment of Hydrogen Technologies Participating in California Electricity Markets

As the electric sector evolves and increasing amounts of variable renewable generation are installed on the system, there are greater needs for system flexibility and sufficient capacity, and greater concern for overgeneration from renewable sources not well matched in time with electric loads. Hydrogen systems have the potential to support the grid in each of these areas. However, limited information is available about the economic competitiveness of hydrogen system configurations. This paper quantifies the value for hydrogen energy storage and demand response systems to participate in select California wholesale electricity markets using 2012 data. For hydrogen systems and conventional storage systems (e.g., pumped hydro, batteries), the yearly revenues from energy, ancillary service, and capacity markets are compared to the yearly cost to establish economic competitiveness. Hydrogen systems can present a positive value proposition for current markets. Three main findings include: (1) For hydrogen systems participating in California electricity markets, producing and selling hydrogen was found to be much more valuable than producing and storing hydrogen to later produce electricity; therefore systems should focus on producing and selling hydrogen and opportunistically providing ancillary services and arbitrage. (2) Tighter integration with electricity markets generates greater revenues (i.e., systems that participate in multiple markets receive the highest revenue). (3) More storage capacity, in excess of what is required to provide diurnal shifting, does not increase competitiveness in current California wholesale energy markets. As more variable renewable generation is installed, the importance of long duration storage may become apparent in the energy price or through additional markets, but currently, there is not a sufficiently large price differential between days to generate enough revenue to offset the cost of additional storage. Future work will involve expanding to consider later year data and multiple regions to establish more generalized results.

25 ENERGY STORAGE↗

Ultra-low radioactivity flexible printed cables

Abstract Flexible printed cables and circuitry based on copper-polyimide materials are widely used in experiments looking for rare events due to their unique electrical and mechanical characteristics. However, past studies have found copper-polyimide flexible cables to contain 400-4700 pg 238 U/g, 16-3700 pg 232 Th/g, and 170-2100 ng nat K/g, which can be a significant source of radioactive background for many current and next-generation ultralow background detectors. This study presents a comprehensive investigation into the fabrication process of copper-polyimide flexible cables and the development of custom low radioactivity cables for use in rare-event physics applications. A methodical step-by-step approach was developed and informed by ultrasensitive assay to determine the radiopurity in the starting materials and identify the contaminating production steps in the cable fabrication process. Radiopure material alternatives were identified, and cleaner production processes and treatments were developed to significantly reduce the imparted contamination. Through the newly developed radiopure fabrication process, fully-functioning cables were produced with radiocontaminant concentrations of 20-31 pg 238 U/g, 12-13 pg 232 Th/g, and 40-550 ng nat K/g, which is significantly cleaner than cables from previous work and sufficiently radiopure for current and next-generation detectors. This approach, employing witness samples to investigate each step of the fabrication process, can hopefully serve as a template for investigating radiocontaminants in other material production processes.

36 MATERIALS SCIENCE↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IDAES Enterprise: Generation Expansion Planning with Enhanced Requirements for Capacity Adequacy Under Renewable Intermittency

Achieving net zero carbon emissions likely requires future power systems to integrate new, flexible energy technologies to accommodate higher levels of capacity from variable renewable energy sources. To determine the optimal deployment of new electricity capacity and to study the likelihood of deployments of new energy technologies, an expansion planning model has been developed as part of the IDAES-Enterprise suite of grid models. The Generation Expansion Planning (GEP) model is a multi-period model in which investment decisions occur yearly, and a Unit Commitment (UC) problem is examined on an hourly timescale. To reduce computational complexity of the GEP model, the UC problem is solved for average “representative days” which leaves out extreme, but relatively common, scenarios in which low renewable generation occurs, leaving the system with inadequacy in capacity. The IDAES-Enterprise GEP model has been modified to include these extreme scenarios while keeping the model reasonably tractable. Specifically, a lazy constraint technique was implemented to check for capacity adequacy on an hourly basis over a large data set of aligned load-wind-solar profiles. As a vast majority of the capacity constraints will not be violated, the technique lowers computational expense by searching for violated capacity constraints over an “iterative manner,” adding those infeasible constraints back into the model. Results on a test case of the Southwest Power Pool shows that the lazy constraint technique significantly reduces retirements and increases installments of natural gas combined cycles and flexible natural gas units. It also reduces some retirements of coal units. These modifications provide a more reasonable estimation of required dispatchable power generation capacity to ensure feasibility during peak net load.

Liu, Peng↗

Modular CO 2 Capture Processes for Integration with Modular Scale Gasification Technologies: Literature Review and Gap Analysis for Future R&D

The motivation for this report is the recent focus of the U.S. Department of Energy’s (DOE) gasification program to develop modular scale gasification processes for electricity generation and other applications. Mass-produced, modular gasification systems have been proposed to decrease the upfront capital costs and to encourage flexible deployment of advanced gasification technology using a diverse set of feedstocks. To fully realize the benefits of advanced gasification technology for power generation as well as other chemical applications, precombustion carbon dioxide (CO 2 ) capture must be considered. Therefore, the aim of this report is to assess the potential of integrating modular scale carbon capture processes with modular scale coal gasification technologies, and to help guide future research and development efforts in this area.

20 FOSSIL-FUELED POWER PLANTS↗

Cooperation between somatic mutation and germline-encoded residues enables antibody recognition of HIV-1 envelope glycans

Viral glycoproteins are a primary target for host antibody responses. However, glycans on viral glycoproteins can hinder antibody recognition since they are self glycans derived from the host biosynthesis pathway. During natural HIV-1 infection, neutralizing antibodies are made against glycans on HIV-1 envelope glycoprotein (Env). However, such antibodies are rarely elicited with vaccination. Previously, the vaccine-induced, macaque antibody DH501 was isolated and shown to bind to high mannose glycans on HIV-1 Env. Understanding how DH501 underwent affinity maturation to recognize glycans could inform vaccine induction of HIV-1 glycan antibodies. Here, we show that DH501 Env glycan reactivity is mediated by both germline-encoded residues that contact glycans, and somatic mutations that increase antibody paratope flexibility. Only somatic mutations in the heavy chain were required for glycan reactivity. The paratope conformation was fragile as single mutations within the immunoglobulin fold or complementarity determining regions were sufficient for eliminating antibody function. Taken together, the initial germline V H DJ H rearrangement generated contact residues capable of binding glycans, and somatic mutations were required to form a flexible paratope with a cavity conducive to HIV-1 envelope glycan binding. The requirement for the presence of most somatic mutations across the heavy chain variable region provides one explanation for the difficulty in inducing anti-Env glycan antibodies with HIV-1 Env vaccination.

59 BASIC BIOLOGICAL SCIENCES↗

Flexible Approximation Model Approach for Bi-Level Integrated System Synthesis

Bi-Level Integrated System Synthesis (BLISS) is an approach that allows design problems to be naturally decomposed into a set of subsystem optimizations and a single system optimization. In the BLISS approach, approximate mathematical models are used to transfer information from the subsystem optimizations to the system optimization. Accurate approximation models are therefore critical to the success of the BLISS procedure. In this paper, new capabilities that are being developed to generate accurate approximation models for BLISS procedure will be described. The benefits of using flexible approximation models such as Kriging will be demonstrated in terms of convergence characteristics and computational cost. An approach of dealing with cases where subsystem optimization cannot find a feasible design will be investigated by using the new flexible approximation models for the violated local constraints.

Sobieszczanski-Sobieski, Jaroslaw↗

Fast Primary Frequency Response using Coordinated DER and Flexible Loads: Framework and Residential-scale Demonstration

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (~8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Primary Frequency Response Using Coordinated DER and Flexible Loads: Framework and Residential-Scale Demonstration: Preprint

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (about 8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Post-flight investigation programmes of recently retrieved solar generators

In 1993 two ESA solar power generators were successfully retrieved from space: EURECA with its 10 panel rigid array in August, after 11 months in a 500 km orbit, and one of the two flexible Hubble Space Telescope (HST) arrays in December, after almost 4 years in a 600 km orbit. Both solar generators are undergoing separate post-flight investigation programs (PFIP). These programs cover investigations of all solar array (SA) components and mechanisms. Since both programs have much in common, most of the component and material investigations are the same. Extremely valuable information on numerous essential subjects, such as atomic oxygen, radiation, meteoroid and space debris environment resulting damage, low cycle fatigue, material degradation, etc. are expected to be obtained for both types of arrays. We will also be able to explain and understand the anomalies experienced on both solar arrays in orbit. The paper will outline both post-flight investigation programs and will concentrate on reporting the first results and findings.

Grelach, Lothar↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.