At least 1,063 records · Page 59

FIFTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton{reg_sign} GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200-350 F. Room temperature leak test failures have been experienced in 6 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30-48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the Orings displayed a compression set ranging from 51-95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350-400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests the CSR model predictions provide a conservative prediction of service life relative to the leak rate criterion. Failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FIFTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton{sup reg.} GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200--350 F. Room temperature leak test failures have been experienced in 5 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30--48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200--300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51--95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350--400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests that CSR model predictions provide a conservative prediction of service life relative to the leak rate criterion. Failure data at lower temperatures is needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

42 ENGINEERING↗

Effect of deposition rate on microstructure and mechanical properties of 17-4 PH stainless steel fabricated by laser engineered net shaping

Laser engineered net shaping (LENS) is an additive manufacturing technique for fabricating and repairing metallic components. However, the relationships between its process parameters and the resulting mechanical properties of alloys such as 17-4 precipitation-hardening (PH) stainless steel require further investigation to enable reliable application. This study examines the specific effect of LENS deposition rate on the microstructure and mechanical properties of 17-4 PH stainless steel. Specimens were fabricated at two different deposition rates (8.47 and 9.31 mm s−1), subjected to subsequent solution and H900 aging treatment, and then evaluated via tensile testing, hardness measurements, and microscopy. A higher deposition rate results in a finer grain structure but increased porosity, leading to greater ultimate tensile strength (∼1294 MPa) yet lower ductility (strain at failure ∼5.8%) compared to the slower deposition rate (∼1266 MPa, ∼9.0% strain). Hardness follows the same trend as tensile strength. Tensile fracture surfaces for both conditions exhibited a mixed mode of ductile dimples and brittle quasi-cleavage regions, with chromium/silicon oxide particles identified within dimples. Complementary finite element modeling indicates that small void fractions primarily reduce ductility by enhancing localized plasticity, with only a marginal decrease in tensile strength. These integrated experimental and numerical results elucidate the mechanical properties linked to deposition rate, providing insight into tailoring LENS processes to achieve desired properties of 17-4 PH stainless steel.

17-4 PH stainlesssteel↗

Design Safety Used in NASA's Human-rated Primary Lithium Batteries

Single cell tests were benign for external short, inadvertent charge and overdischarge into reversal up to 4.5 A. At lower current loads cells die (may be due to excessive dendrite formation) benignly. String level external short circuits lead to an unbalanced overdischarge, with one cell going into reversal. The result is catastrophic violent venting. Unbalanced string overdischarges at different currents causes catastrophic violent venting also. Heat-to-vent is very dramatic displaying violent venting Simulated internal short is also catastrophic and displays violent venting. Battery is not UL-rated; hence does not have dual-fault tolerance or tolerance to inherent cell tolerance to failures Battery Design for NASA JSC's human-rated application for use on ISS was changed to include two bypass diodes per cell to provide for two-failure tolerance to overdischarge into reversal (and external short) hazards.

Jeevarajan, J.↗

Optimal Control Allocation for Distributed Electric Propulsion in A Series/Parallel Partial Hybrid Powertrain

The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept transport aircraft representative of technology anticipated for a 2040 entry-into-service date. The powertrain consists of a single thrust-producing geared turbofan engine with generators driving a series/parallel partial hybrid power/propulsion system. The architecture includes 16 underwing contrarotating fans, eight on each side. The distributed fans can be used by the flight control system to augment or replace the rudder function. This paper sets up the optimal control problem of setpoint determination for individual wingfans in the distributed propulsion system, accounting for electrical string efficiencies, saturations, and failures. The solution minimizes power consumption while maintaining thrust and torque on the airframe for maneuvering. Additionally, thrust that would have been lost due to temporary fan speed or power saturation is optimally redistributed to maintain overall desired thrust and torque on the aircraft. A simulation of a coordinated turn utilizing the distributed electric propulsion for yaw rate control in a multiple wingfan failure scenario demonstrates the robustness of the powertrain design to failures and helps define its limitations.

Distributed Electric Propulsion↗

Optimal Control Allocation for Distributed Electric Propulsion in A Series/Parallel Partial Hybrid Powertrain

The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept transport aircraft representative of technology anticipated for a 2040 entry-into-service date. The powertrain consists of a single thrust-producing geared turbofan engine with generators driving a series/parallel partial hybrid power/propulsion system. The architecture includes 16 underwing contrarotating fans, eight on each side. The distributed fans can be used by the flight control system to augment or replace the rudder function. This paper sets up the optimal control problem of setpoint determination for individual wingfans in the distributed propulsion system, accounting for electrical string efficiencies, saturations, and failures. The solution minimizes power consumption while maintaining thrust and torque on the airframe for maneuvering. Additionally, thrust that would have been lost due to temporary fan speed or power saturation is optimally redistributed to maintain overall desired thrust and torque on the aircraft. A simulation of a coordinated turn utilizing the distributed electric propulsion for yaw rate control in a multiple wingfan failure scenario demonstrates the robustness of the powertrain design to failures and helps define its limitations.

Distributed Electric Propulsion↗

Ice-Crystallization Kinetics in the Catalyst Layer of a Proton-Exchange-Membrane Fuel Cell

Nucleation and growth of ice in the catalyst layer of a proton-exchange-membrane fuel cell (PEMFC) are investigated using isothermal differential scanning calorimetry and isothermal galvanostatic cold-starts. Isothermal ice-crystallization rates and ice-nucleation rates are obtained from heat-flow and induction-time measurements at temperatures between 240 and 273 K for four commercial carbon-support materials with varying ionomer fraction and platinum loading. Measured induction times follow expected trends from classical nucleation theory and reveal that the carbon-support material and ionomer fraction strongly impact the onset of ice crystallization. Conversely, dispersed platinum particles play little role in ice crystallization. Following our previous approach, a nonlinear ice-crystallization rate expression is obtained from Johnson-Mehl-Avrami-Kolmogorov (JMAK) theory. A validated rate expression is now available for predicting ice crystallization within water-saturated catalyst layers. Using a simplified PEMFC isothermal cold-start continuum model, we compare cell-failure time predicted using the newly obtained rate expression to that predicted using a traditional thermodynamic-based approach. From this comparison, we identify conditions under which including ice-crystallization kinetics is critical and elucidate the impact of freezing kinetics on low-temperature PEMFC operation. The numerical model illustrates that cell-failure time increases with increasing temperature due to a longer required time for ice nucleation. Hence, ice-crystallization kinetics is critical when induction times are long (i.e., in the "nucleation-limited" regime for T > 263 K). Cell-failure times predicted using ice-freezing kinetics are in good agreement with the isothermal cold-starts, which also exhibit long and distributed cell-failure times for T > 263 K. These findings demonstrate a significant departure from cell-failure times predicted using the thermodynamic-based approach.

Dursch, T. J.↗

Failure Diameter Resolution Study

Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Predicting Rupture Pressure and Leak Rate of Alloy 600 Tubes with ODSCC and Comparing with Test Results (Technical Letter Report)

This report summarizes structural integrity work performed for the U.S. NRC that predicts the rupture pressure and leak rate of flawed steam generator (SG) tubes. The work includes pressure testing of straight tubes with lab-induced outer diameter stress corrosion cracks (ODSCC). Existing models for predicting rupture pressure and leak rate of straight tubes with well-defined, rectangular, electro-discharge-machined (EDM) flaws were modified and used to predict the measured rupture pressures and leak rates from straight tubes with ODSCC. Models previously developed for EDM notches in straight tubes were modified for ODSCC by using the equivalent rectangular crack (ERC) method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Chapter 3: Photovoltaic Module Stability and Reliability

Profits realized from investment in photovoltaic will benefit from decades of reliable operation. Service life prediction through accelerated tests is only possible if indoor tests duplicate power loss and failure modes observed in fielded systems. Therefore, detailing and quantifying power loss and failure modes is imperative. In the first section, we examine recent trends in degradation rates, the gradual power loss observed for different technologies, climates and other significant factors. In the second section, we provide a summary of the most commonly observed failure modes in fielded systems.

14 SOLAR ENERGY↗

Quantifying Reaction and Rate Heterogeneity in Battery Electrodes in 3D through Operando X-ray Diffraction Computed Tomography

In composite battery electrode architectures, local limitations in ionic and electronic transport can result in nonuniform energy storage reactions. Understanding such reaction heterogeneity is important to optimizing battery performance, including rate capability and mitigating degradation and failure. Here, we use spatially resolved X-ray diffraction computed tomography to map the reaction in a composite electrode based on the LiFePO 4 active material as it undergoes charge and discharge. Accelerated reactions at the electrode faces in contact with either the separator or the current collector demonstrate that both ionic and electronic transport limit the reaction progress. The data quantify how nonuniformity of the electrode reaction leads to variability in the charge/discharge rate, both as a function of time and position within the electrode architecture. Importantly, this local variation in the reaction rate means that the maximum rate that individual cathode particles experience can be substantially higher than the average, control charge/discharge rate, by a factor of at least 2-5 times. As a result, this rate heterogeneity may accelerate rate-dependent degradation pathways in regions of the composite electrode experiencing faster-than-average reaction and has important implications for understanding and optimizing rate-dependent battery performance. Benchmarking multiscale continuum model parameters against the observed reaction heterogeneity permits extension of these models to other electrode geometries.

25 ENERGY STORAGE↗

A latent fault Markov model for a highly reliable triplex computer system

A Markov model of a highly reliable triplex system was constructed to evaluate the probability of system failure as a function of the propagation of latent faults. It is found that if the propagation rate of latent faults is extremely high, they do not significantly affect the probability of system failure, while if the propagation rate is extremely low, the survivability of the system is improved. The propagation rate that is most harmful to the survivability of the system is determined as a function of the duration of the flight. A decrease in the probability of system failure due to latency is noted if the probability of any two faults giving the same output is extremely low.

Swern, Frederic L.↗

Sensor Data Quality and Angular Rate Down-Selection Algorithms on SLS EM-1

The NASA Space Launch System Block 1 launch vehicle is equipped with an Inertial Navigation System (INS) and multiple Rate Gyro Assemblies (RGA) that are used in the Guidance, Navigation, and Control (GN&C) algorithms. The INS provides the inertial position, velocity, and attitude of the vehicle along with both angular rate and specific force measurements. Additionally, multiple sets of co-located rate gyros supply angular rate data. The collection of angular rate data, taken along the launch vehicle, is used to separate out vehicle motion from flexible body dynamics. Since the system architecture uses redundant sensors, the capability was developed to evaluate the health (or validity) of the independent measurements. A suite of Sensor Data Quality (SDQ) algorithms is responsible for assessing the angular rate data from the redundant sensors. When failures are detected, SDQ will take the appropriate action and disqualify or remove faulted sensors from forward processing. Additionally, the SDQ algorithms contain logic for down-selecting the angular rate data used by the GNC software from the set of healthy measurements. This paper explores the trades and analyses that were performed in selecting a set of robust fault-detection algorithms included in the GN&C flight software. These trades included both an assessment of hardware-provided health and status data as well as an evaluation of different algorithms based on time-to-detection, type of failures detected, and probability of detecting false positives. We then provide an overview of the algorithms used for both fault-detection and measurement down selection. We next discuss the role of trajectory design, flexible-body models, and vehicle response to off-nominal conditions in setting the detection thresholds. Lastly, we present lessons learned from software integration and hardware-in-the-loop testing.

Park, Thomas↗

Rehabilitation Needs for Burbot in the Kootenai River, Idaho, USA, and British Columbia, Canada

Abstract We developed rehabilitation goals for burbot Lota lota in the Kootenai River, Idaho and British Columbia. After developing a catchability model for burbot in the Kootenai River, we used capture rates in two Alaskan rivers to develop surrogate rehabilitation targets for burbot in the Kootenai River. Then we used demographic statistics for burbot in the Kootenai River in a stochastic density-dependent population model to estimate recruitment rates for population rehabilitation. If recruitment failure continued, the population would decline to extinction by 2018. However, the population would reach the interim target abundance of 5,500 individuals (45 fish/km; 3.0 fish/ha) within 25 years if each adult produced 0.85 recruits per year, and it would reach the ultimate target abundance of 17,500 individuals (143 fish/km; 9.6 fish/ha) if each adult produced 1.1 recruits per year. After 25 years, 5,500 burbot would be present with 50% likelihood at a recruitment rate of 0.85 recruits per adult and 95% likelihood at a recruitment rate of 0.88 recruits per adult; 17,000 burbot would be present with 50% likelihood at a recruitment rate of 1.03 recruits per adult and 95% likelihood at a recruitment rate of 1.16 recruits per adult. The time to reach the interim rehabilitation goal of 5,500 burbot would decline from 50 to 25 years as the recruitment rate increased from 0.72 to 0.87 recruits per adult; the time to reach the ultimate rehabilitation goal of 17,500 burbot would decline from 50 to 25 years as recruitment increased from 0.82 to 1.07 recruits per adult. We recommend the following rehabilitation goals for burbot in the Kootenai River: (1) an interim population goal of 5,500 burbot (0.484 fish per net-day) and an ultimate population goal of 17,500 burbot (1.23 fish per net-day); (2) population rehabilitation within 25 years; and (3) an annual recruitment rate of 0.85–1.1 recruits per adult.

Paragamian, Vaughn L.↗

Failure Mechanism of Fast-Charged Lithium Metal Batteries in Liquid Electrolyte

In recent years, lithium anode has re-attracted broad interest because of the necessity of employing lithium metal in the next-generation battery technologies such as lithium sulfur (Li-S) and lithium oxygen (Li-O2) batteries. Fast capacity degradation and safety issue associated with rechargeable lithium metal batteries have been reported, although the fundamental understanding on the failure mechanism of lithium metal at high charge rate is still under debate due to the complicated interfacial chemistry between lithium metal and electrolyte. Herein, we demonstrate that, at high current density, the quick growth of porous solid electrolyte interphase towards bulk lithium, instead of towards the separator, dramatically builds up the cell impedance that directly leads to the cell failure. Understanding the lithium metal failure mechanism is very critical to gauge the various approaches used to address the stability and safety issues associated with lithium metal anode. Otherwise, all cells will fail quickly at high rates before the observation of any positive effects that might be brought from adopting the new strategies to protect lithium.

Environmental Molecular Sciences Laboratory↗

Effects of Intercritical Annealing Temperature on Mechanical Properties of Fe-7.9Mn-0.14Si-0.05Al-0.07C Steel

A medium Mn steel has been designed to achieve an excellent combination of strength and ductility based on the TRIP (Transformation Induced Plasticity) concept for automotive applications. Following six passes of hot rolling at 850 °C, the Fe-7.9Mn-0.14Si-0.05Al-0.07C (wt.%) steel was warm-rolled at 630 °C for seven passes and subsequently air cooled to room temperature. The sample was subsequently intercritically annealed at various temperatures for 30 min to promote the reverse transformation of martensite into austenite. The obtained results show that the highest volume fraction of austenite is 39% for the sample annealed at 600 °C. This specimen exhibits a yield stress of 910 MPa and a high ultimate tensile stress of 1600 MPa, with an elongation-to-failure of 0.29 at a strain rate of 1 × 10⁻³/s. The enhanced work-hardening ability of the investigated steel is closely related to martensitic transformation and the interaction of dislocations. Especially, the alternate arrangement of acicular ferrite (soft phase) and ultrafine austenite lamellae (50–200 nm, strong and ductile phase) is the key factor contributing to the excellent combination of strength and ductility. On the other hand, the as-warm-rolled sample also exhibits the excellent combination of strength and ductility, with elongation-to-failure much higher than those annealed at temperatures above 630 °C.

36 MATERIALS SCIENCE↗

Comparative Study of LDR (Manchester System) and HDR Image-guided Conformal Brachytherapy of Cervical Cancer: Patterns of Failure, Late Complications, and Survival

Purpose: To compare patterns of failure, late toxicities, and survival in locally advanced cervical cancer patients treated by either low-dose-rate (LDR) or conformal high-dose-rate (HDRc) brachytherapy as a part of curative radiotherapy. Materials and Methods: A retrospective comparative study of 217 advanced cervix cancer patients was conducted; 90 of these patients received LDR and 127 received HDRc brachytherapy. All patients were staged using International Federation of Gynecology and Obstetrics (FIGO) rules, had pretreatment magnetic resonance imaging (MRI), and were treated with concurrent cisplatin chemoradiotherapy. Both groups matched for FIGO stage, MRI tumor volume, and uterine invasion status. Results: Local and pelvic failures were similar 12-13% and 14% both in both groups. Abdominal and systemic failures in LDR group were 21% and 24%, whereas corresponding failures in HDRc group were 20% and 24%. Sixty-eight percent (87/127) of patients treated by HDRc remained asymptomatic, whereas 42% (38/90) of patients were asymptomatic from the bowel and bladder symptoms after treatment with LDR. The 5-year OS rate was 60% (SE = 4%). The 5-year failure-free survival rate was 55% (SE = 3%). There was no significant difference between the groups. Conclusions: Image-guided HDRc planning led to a large decrease in late radiation effects in patients treated by HDRc. Patterns of failure and survival were similar in patients treated either by LDR or HDRc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗