Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast Fourier transform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,051 records · Page 59

Sensing Super-Position: Human Sensing Beyond the Visual Spectrum

The coming decade of fast, cheap and miniaturized electronics and sensory devices opens new pathways for the development of sophisticated equipment to overcome limitations of the human senses. This paper addresses the technical feasibility of augmenting human vision through Sensing Super-position by mixing natural Human sensing. The current implementation of the device translates visual and other passive or active sensory instruments into sounds, which become relevant when the visual resolution is insufficient for very difficult and particular sensing tasks. A successful Sensing Super-position meets many human and pilot vehicle system requirements. The system can be further developed into cheap, portable, and low power taking into account the limited capabilities of the human user as well as the typical characteristics of his dynamic environment. The system operates in real time, giving the desired information for the particular augmented sensing tasks. The Sensing Super-position device increases the image resolution perception and is obtained via an auditory representation as well as the visual representation. Auditory mapping is performed to distribute an image in time. The three-dimensional spatial brightness and multi-spectral maps of a sensed image are processed using real-time image processing techniques (e.g. histogram normalization) and transformed into a two-dimensional map of an audio signal as a function of frequency and time. This paper details the approach of developing Sensing Super-position systems as a way to augment the human vision system by exploiting the capabilities of Lie human hearing system as an additional neural input. The human hearing system is capable of learning to process and interpret extremely complicated and rapidly changing auditory patterns. The known capabilities of the human hearing system to learn and understand complicated auditory patterns provided the basic motivation for developing an image-to-sound mapping system. The human brain is superior to most existing computer systems in rapidly extracting relevant information from blurred, noisy, and redundant images. From a theoretical viewpoint, this means that the available bandwidth is not exploited in an optimal way. While image-processing techniques can manipulate, condense and focus the information (e.g., Fourier Transforms), keeping the mapping as direct and simple as possible might also reduce the risk of accidentally filtering out important clues. After all, especially a perfect non-redundant sound representation is prone to loss of relevant information in the non-perfect human hearing system. Also, a complicated non-redundant image-to-sound mapping may well be far more difficult to learn and comprehend than a straightforward mapping, while the mapping system would increase in complexity and cost. This work will demonstrate some basic information processing for optimal information capture for headmounted systems.

Maluf, David A.↗

Image phase shift invariance based cloud motion displacement vector calculation method for ultra-short-term solar PV power forecasting

Irradiance received on the earth's surface is the main factor that affects the output power of solar PV plants, and is chiefly determined by the cloud distribution seen in a ground-based sky image at the corresponding moment in time. It is the foundation for those linear extrapolation-based ultra-short-term solar PV power forecasting approaches to obtain the cloud distribution in future sky images from the accurate calculation of cloud motion displacement vectors (CMDVs) by using historical sky images. Theoretically, the CMDV can be obtained from the coordinate of the peak pulse calculated from a Fourier phase correlation theory (FPCT) method through the frequency domain information of sky images. The peak pulse is significant and unique only when the cloud deformation between two consecutive sky images is slight enough, which is likely possible for a very short time interval (such as 1?min or shorter) with common changes in the speed of cloud. Sometimes, there will be more than one pulse with similar values when the deformation of the clouds between two consecutive sky images is comparatively obvious under fast changing cloud speeds. This would probably lead to significant errors if the CMDVs were still only obtained from the single coordinate of the peak value pulse. However, the deformation estimation of clouds between two images and its influence on FPCT-based CMDV calculations are terrifically complex and difficult because the motion of clouds is complicated to describe and model. Therefore, to improve the accuracy and reliability under these circumstances in a simple manner, an image-phase-shift-invariance (IPSI) based CMDV calculation method using FPCT is proposed for minute time scale solar power forecasting. First, multiple different CMDVs are calculated from the corresponding consecutive images pairs obtained through different synchronous rotation angles compared to the original images by using the FPCT method. Second, the final CMDV is generated from all of the calculated CMDVs through a centroid iteration strategy based on its density and distance distribution. Third, the influence of different rotation angle resolution on the final CMDV is analyzed as a means of parameter estimation. Simulations under various scenarios including both thick and thin clouds conditions indicated that the proposed IPSI-based CMDV calculation method using FPCT is more accurate and reliable than the original FPCT method, optimal flow (OF) method, and particle image velocimetry (PIV) method.

14 SOLAR ENERGY↗

Novel microwave assisted sol–gel synthesis (MW-SGS) and electrochromic performance of petal like h-WO{sub 3} thin films

Graphical abstract: Electrochromic intercalation and deintercalation of Li{sup +} ions and electrons is facilitated by providing hexagonal tunnel, trigonal cavity and square window which allows easy and fast insertion and extraction of ions. Highlights: ► Novel two step MW-SGS is first time employed to prepare WO{sub 3} thin films. ► MW-SGS is simple and cost effective technique for preparation of nanostructures. ► Petal-like hexagonal WO{sub 3} nanodisks were successfully deposited. ► O/W ratio calculated by XPS studies is 2.89. ► Good electrochromic performance suggests practical usability of proposed technique. -- Abstract: Use of domestic microwave oven is first time employed for chemical deposition of nanocrystalline hexagonal WO{sub 3} (h-WO{sub 3}) thin films. Low cost precursors like sodium tungstate, hydrochloric acid, oxalic acid and potassium sulfate signifies cost effectiveness of this thin film fabrication route. Scanning electron microscopy images reveal formation of petal like nanodisks. A number of analytical techniques were used to characterize the WO{sub 3} petal like nanodisks, including X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy, FT-IR spectroscopy, Raman scattering spectroscopy, UV–visible spectrophotometry and cyclic voltammetry (CV). The X-ray photoelectron spectroscopic studies revealed 2.89 O/W atomic ratio. The electrical transport studies on WO{sub 3} thin films show semiconducting behavior with n-type semiconductivity. The value of determined coloration efficiency is 57.90 cm{sup 2}/C. The mechanism of Li{sup +} intercalation and deinercalation in h-WO{sub 3} matrix is proposed for enhanced electrochromism.

36 MATERIALS SCIENCE↗

NiAl{sub 2}O{sub 4} catalysts prepared by combustion reaction using glycine as fuel

Graphical abstract: The reaction temperature was found to remain is practically constant throughout the interval preceding ignition, after which the temperature increased abruptly, reaching the maximum combustion temperature. All the reactions occurred in a matter of minutes, i.e., 5.8, 5.8 and 6 min, respectively, for compositions GES, 10GE and 20GE. Among the benefits of the combustion synthesis method are low processing cost, energy efficiency, high production rate and, especially, short reaction periods when compared with conventional methods (solid state reaction) to prepare ceramic oxide powders that require high calcination temperatures and long reaction periods. Highlights: {yields} We use a simple, fast and inexpensive technique for processing NiAl{sub 2}O{sub 4} catalyst nanopowders. {yields} We study the preparation of powders with nanometric sized particles. {yields} This material is extremely attractive for use in the development of new catalysts for a variety of chemical processes. {yields} Nanometric sized particles depend of the amount of glycine used in the synthesis process. -- Abstract: The aim of this work is to evaluate the influence of glycine fuel used in a stoichiometric proportion and with a 10% and 20% excess of this fuel in the preparation of NiAl{sub 2}O{sub 4} catalyst by combustion reaction. The powders were characterized by XRD, textural analysis by the BET nitrogen adsorption method, particle size distribution, and FTIR. The results show the presence of NiAl{sub 2}O{sub 4} as a major phase and traces of NiO and Ni in all the catalysts studied here. The crystallite sizes were 22 nm in the stoichiometric composition and 18 and 9 nm, respectively, in the composition containing 10% and 20% excess glycine. The powder obtained from all the compositions presented morphological characteristics with irregular plate-shaped agglomerates. The increase in excess glycine caused the particle size in the three compositions to decrease to 59, 54 and 38 nm and the agglomerate size to increase to 7, 8 and 12 {mu}m, respectively.

36 MATERIALS SCIENCE↗

Remote Thermal IR Spectroscopy of our Solar System

Indirect methods to detect extrasolar planets have been successful in identifying a number of stars with companion planets. No direct detection of an extrasolar planet has yet been reported. Spectroscopy in the thermal infrared region provides a potentially powerful approach to detection and characterization of planets and planetary systems. We can use knowledge of our own solar system, its planets and their atmospheres to model spectral characteristics of planets around other stars. Spectra derived from modeling our own solar system seen from an extrasolar perspective can be used to constrain detection strategies, identification of planetary class (terrestrial vs. gaseous) and retrieval of chemical, thermal and dynamical information. Emission from planets in our solar system peaks in the thermal infrared region, approximately 10 - 30 microns, substantially displaced from the maximum of the much brighter solar emission in the visible near 0.5 microns. This fact provides a relatively good contrast ratio to discriminate between stellar (solar) and planetary emission and optimize the delectability of planetary spectra. Important molecular constituents in planetary atmospheres have rotational-vibrational spectra in the thermal infrared region. Spectra from these molecules have been well characterized in the laboratory and studied in the atmospheres of solar system planets from ground-based and space platforms. The best example of such measurements are the studies with Fourier transform spectrometers, the Infrared Interferometer Spectrometers (IRIS), from spacecraft: Earth observed from NIMBUS 8, Mars observed from Mariner 9, and the outer planets observed from Voyager spacecraft. An Earth-like planet is characterized by atmospheric spectra of ozone, carbon dioxide, and water. Terrestrial planets have oxidizing atmospheres which are easily distinguished from reducing atmospheres of gaseous giant planets which lack oxygen-bearing species and are characterized by spectra containing hydrocarbons such as methane and ethane. Spectroscopic information on extrasolar planets thus can permit their classification. Spectra and spectral lines contain information on the temperature structure of the atmosphere. Line and band spectra can be used to identify the molecular constituents and retrieve species abundances, thereby classifying and characterizing the planet. At high enough spectral resolution characteristic planetary atmospheric dynamics and unique phenomena such as failure of local thermodynamic equilibrium can be identified. Dynamically induced effects such as planetary rotation and orbital velocity shift and change the shape of spectral features and must be modeled in detailed spectral studies. We will use our knowledge of the compositional, thermal and dynamical characteristics of planetary atmospheres in our own solar system to model spectra observed remotely on similar planets in extrasolar planetary systems. We will use a detailed radiative transfer and beam integration program developed for the modeling and interpretation of thermal infrared spectra measured from nearby planet planets to generate models of an extra-solar "Earth" and "Jupiter". From these models we will show how key spectral features distinguish between terrestrial and gaseous planets, what information can be obtained with different spectral resolution, what spectral features can be used to search for conditions for biogenic activity, and how dynamics and distance modify the observed spectra. We also will look at unique planetary phenomena such as atmospheric lasing and discuss their utility as probes for detection and identification of planets. Results of such studies will provide information to constrain design for instrumentation needed to directly detect extrasolar planets.

Kostiuk, Theodor↗

Comparing gas composition from fast pyrolysis of live foliage measured in bench-scale and fire-scale experiments

Background: Fire models have used pyrolysis data from oxidising and non-oxidising environments for flaming combustion. In wildland fires pyrolysis, flaming and smouldering combustion typically occur in an oxidising environment (the atmosphere). Aims: Using compositional data analysis methods, determine if the composition of pyrolysis gases measured in non-oxidising and ambient (oxidising) atmospheric conditions were similar. Methods: Permanent gases and tars were measured in a fuel-rich (non-oxidising) environment in a flat flame burner (FFB). Permanent and light hydrocarbon gases were measured for the same fuels heated by a fire flame in ambient atmospheric conditions (oxidising environment). Log-ratio balances of the measured gases common to both environments (CO, CO 2 , CH 4 , H 2 , C 6 H 6 O (phenol), and other gases) were examined by principal components analysis (PCA), canonical discriminant analysis (CDA) and permutational multivariate analysis of variance (PERMANOVA). Key results: Mean composition changed between the non-oxidising and ambient atmosphere samples. PCA showed that flat flame burner (FFB) samples were tightly clustered and distinct from the ambient atmosphere samples. CDA found that the difference between environments was defined by the CO-CO 2 log-ratio balance. PERMANOVA and pairwise comparisons found FFB samples differed from the ambient atmosphere samples which did not differ from each other. Conclusion: Relative composition of these pyrolysis gases differed between the oxidising and non-oxidising environments. This comparison was one of the first comparisons made between bench-scale and field scale pyrolysis measurements using compositional data analysis. Implications: These results indicate the need for more fundamental research on the early time-dependent pyrolysis of vegetation in the presence of oxygen.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Strategies for Obtaining Confident Identifications in Bottom-Up Proteomics Measurements Using Hybrid FTMS instruments

Hybrid FTMS instruments, such as the LTQ-FTTM and LTQ-OrbitrapTM, are capable of generating fast duty cycle linear ion trap MS/MS data along with high resolution information without compromising the overall throughput of measurements. Combined with online LC separations, these instruments represent powerful and flexible tools for proteomics research. In the present work, we explore strategies for high throughput, high coverage proteomics measurements using hybrid FTMS instruments. Our accurate mass and time tag (AMT tag) strategy enables identification of thousands of peptides in a single LC-FTMS analysis by comparing accurate molecular mass and LC elution time information from the analysis to a reference database. An alternative strategy considered here employs linear ion trap (low resolution) MS/MS identifications generated by an appropriate search engine, such as SEQUEST; the high resolution precursor ion spectra were used to refine the MS/MS identifications, an approach termed Accurate Precursor Mass Filter (APMF). The APMF results can be additionally filtered using the LC elution time information from the AMT tag database, which constitutes a Precursor Mass and Time Filter (PMTF), the third approach implemented in this study. Both the APMF and the PMTF approaches are evaluated for coverage and confidence of peptide identifications and contrasted with the current AMT tag strategy. Two separate methodologies were used to reliably quantify identification confidence: a commonly used decoy database method and an alternative method based on the mass accuracy histogram. The two methodologies produced consistent results, confirming the validity of the identification confidence evaluations. Comparison of the three approaches has shown that the AMT tag data analysis approach may be preferential for studies giving a priority to the highest achievable coverage. The APMF approach by itself does not require AMT tag database and provides a moderate coverage combined with acceptable confidence values of ~99%.The PMTF approach yielded a significantly better peptide identification confidence, >99.9%, that essentially excluded any false peptide identifications. The results suggest that even with a perfect peptide ID (0% FDR in the peptide MS/MS database), the peak matching FDR is a function of the database size, so smaller high confidence databases are the goal. Thus a combined strategy can implement multi-pass APMF approach to generate high confidence AMT tag databases, which can be then validated using PMTF approach; the compact high quality databases will be used for subsequent high-throughput, high coverage AMT tag studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗