Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

πScope: Python based scientific workbench with MDSplus data visualization tool

In this work, a newly developed python based scientific data analysis and visualization tool, πScope (http://piscope.psfc.mit.edu), is reported. The primary motivation is 1) to provide an updated tool to browse the MDSplus data beyond existing dwscope/jScope and 2) to realize a universal foundation to construct interface tools to perform computer modeling from experimental data. To visualize MDSplus data, πScope has many features including overplotting different signals and discharges, generating various plot types (line, contour, image, etc.), performing in-panel data analysis using python scripts, and producing publication quality graphics. The logic to generate multi-panel plots is designed to be backward compatible with dwscope, enabling smooth migration for users. πScope uses multi-threading in data loading, and is easy to modify and expand due to its object-oriented design. Furthermore, A user can access the data structure both from a GUI and a script, enabling relatively complex data analysis workflow built quickly on πScope.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An automated and portable method for selecting an optimal GPU frequency

Power consumption poses a significant challenge in current and emerging graphics processing unit (GPU) enabled high-performance computing systems. In modern GPUs, dynamic voltage frequency scaling (DVFS) appears to be a reliable control to regulate power consumption and performance. However, the DVFS design space is large - hence, brute-force approaches are infeasible to select the optimal frequency. Furthermore, no single frequency can be universally optimal for applications with varying computational intensities. Thus, the application's complexity and the availability of a wide range of frequency settings are a challenge in selecting the optimal frequency configuration for a given GPU workload. To that end, this paper proposes a systematic approach that consists of three steps. The feature characterization study identifies the fine-grain GPU utilization metrics that influence the power consumption and execution time of a given workload. To understand the performance, power, and energy consumption behaviors of a workload across GPU's DVFS design space, we derived analytical power and performance models using the identified fine-grain features. Here, it is shown that the same set of GPU utilization metrics can estimate both the power consumption and execution time while being agnostic of changes to frequency and input sizes. Applying a power control with the single objective of reducing power may cause performance degradation, leading to more energy consumption. A multi-objective approach is proposed to select the optimal GPU DVFS configuration for a workload that reduces power consumption with negligible degradation in performance. The evaluation was conducted using SPEC ACCEL benchmarks and three real applications - NAMD LAMMPS, and LSTM on NVIDIA GV100, GA100, and AMD MI210 GPUs. On average, real applications showed 29.6% energy savings with a performance loss of 5.2% on GA100 and 22.6% energy savings with a performance loss of 4.7% on GV100. Moreover, the proposed models are portable to real applications, GPU architectures, and vendors, and require metric collection at only the default frequency rather than all supported DVFS configurations. Additionally, we conducted a comparison between our models and the GPU assembly instructions (PTX)-based static models. The results revealed a significant reduction in the average error rates, with a decrease from 19.7% to 3.1% for power models and from 29.4% to 5.2% for performance models.

97 MATHEMATICS AND COMPUTING↗

Generalized fiducial inference on differentiable manifolds

We introduce a novel approach to inference on parameters that take values in a Riemannian manifold embedded in a Euclidean space. Parameter spaces of this form are ubiquitous across many fields, including chemistry, physics, computer graphics, and geology. Here, this new approach uses generalized fiducial inference (GFI) to obtain a posterior-like distribution on the manifold, without needing to know local parameterizations that map to the constrained space from an unconstrained Euclidean space. Using mathematical tools from Riemannian geometry, we construct a constrained generalized fiducial distribution (CGFD). A Bernstein-von Mises-type result for the CGFD, which provides intuition for how the desirable asymptotic qualities of the unconstrained generalized fiducial distribution are inherited by the CGFD, is provided. To illustrate the practical use of the CGFD, we provide a proof-of-concept example in the context of a linear logspline density estimation problem, and demonstrate that CGFD-based confidence sets exhibit desirable coverage properties via simulation. As an application, we fit a CGFD to COVID-19 case count data from North Carolina, USA.

97 MATHEMATICS AND COMPUTING↗

GPU-resident sparse direct linear solvers for alternating current optimal power flow analysis

Integrating renewable resources within the transmission grid at a wide scale poses significant challenges for economic dispatch as it requires analysis with more optimization parameters, constraints, and sources of uncertainty. This motivates the investigation of more efficient computational methods, especially those for solving the underlying linear systems, which typically take more than half of the overall computation time. In this paper, we present our work on sparse linear solvers that take advantage of hardware accelerators, such as graphical processing units (GPUs), and improve the overall performance when used within economic dispatch computations. We treat the problems as sparse, which allows for faster execution but also makes the implementation of numerical methods more challenging. We present the first GPU-native sparse direct solver that can execute on both AMD and NVIDIA GPUs. We demonstrate significant performance improvements when using high-performance linear solvers within alternating current optimal power flow (ACOPF) analysis. Furthermore, we demonstrate the feasibility of getting significant performance improvements by executing the entire computation on GPU-based hardware. Finally, we identify outstanding research issues and opportunities for even better utilization of heterogeneous systems, including those equipped with GPUs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pressure falloff testing to characterize CO 2 plume and dry-out zone during CO 2 injection in saline aquifers

The fluid mobilities and the lateral extent of the CO 2 plume and the dry-out zone are among important unknowns required to effectively manage CO 2 storage in saline aquifers projects. These unknowns can be derived from pressure falloff testing which has been widely used to characterize the subsurface. This paper provides a three-region analytical solution for falloff pressure during the infinite-acting period of CO 2 injection in saline aquifers. The solution is derived using Laplace transformation technique of the governing diffusivity equations and the accompanying initial and boundary conditions. The exact solution is validated against numerical results obtained from a black-oil reservoir simulator for two cases. The solution is approximated into simple forms in real-time domain considering different time periods. Then, a graphical semi-log analysis technique based on the approximate solutions is provided as an interpretation tool of falloff tests where the fluid mobilities and the extents of dry-out zone and CO 2 plume can be inferred. The interpretation technique is applied to synthetic falloff test data to investigate its potential and reliability.

02 PETROLEUM↗

Common risk segment mapping: Streamlining exploration for carbon storage sites, with application to coastal Texas and Louisiana

Large-scale deployment of Carbon Capture and Storage (CCS) will require a commensurately large number of sites. Efficient screening methods are needed to create investment assurance and focus efforts on the most promising sites. The problem is similar to petroleum exploration, for which there are well-developed (though seldom published) workflows, including Common Risk Segment (CRS) mapping. In brief, the process requires 1) defining the key play elements; 2) identifying candidate geologic intervals for each; 3) creating fact-based maps for those intervals; 4) determining minimum criteria for the success of each element; 5) reinterpreting the fact-based maps in terms of chance of success; and 6) combining the individual maps to form a composite, basin-scale view of prospectivity. We adapt the CRS process to screening for CO 2 storage sites. Critically, we redefine the process in terms of cost of characterization and development, rather than chance of success. For illustration, we apply the process to the example of the Lower Miocene on the Texas and Louisiana Gulf Coast. We show that the predictions are consistent with historic hydrocarbon production volumes and rates. The power of the CRS method is that it creates a systematic approach to geologic evaluation and translates complex, multidimensional analysis into clear, graphical and easily comprehended business inputs. The results highlight sweet spots and identifies critical risks, suggesting a focus for further data collection and analysis. Furthermore, the method developed here can be applied to both surface and subsurface factors anywhere that there is interest in geologic storage of CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Development of a CPU/GPU portable software library for Lagrangian–Eulerian simulations of liquid sprays

The Lagrangian–Eulerian method is widely used for simulations of fuel sprays in turbulent combustion because of the advantage of treating the spray droplets as discrete points. One challenge of the Lagrangian–Eulerian method is the intense computational requirement when tracking the large number of Lagrangian particles needed for high fidelity. We have developed a performance-portable library, Grit, to track the Lagrangian particles in parallel on central processing unit (CPU) and graphics processing unit (GPU) accelerated high performance computing (HPC) architectures. Grit is a C++ library which employs Message Passing Interface (MPI) for distributed memory parallelism and Kokkos programming model for on-node shared memory parallelism with performance portability across different architectures of GPUs and multi-core/manycore CPUs. The parallel algorithms, key parallel kernels, and their performances on the pre-exascale supercomputer, Summit, are presented. Grit is coupled with a direct numerical simulation (DNS) solver, S3D, for multiphase simulations. A conservative formulation has been developed and implemented in Grit for phase coupling with thermodynamic consistency. The formulation separates the conservation of mass, momentum and energy from the physical models to prevent accidental violation of conservation laws due to inconsistent models. The formulation also enforces consistent definitions of enthalpies of the fuel for both phases and the latent heat of evaporation. Finally, simulations of turbulent particle-laden flow and the evaporation of dilute turbulent spray jet are performed to verify the software implementation, and to demonstrate the scalability of Grit for large-scale multiphase simulations.

97 MATHEMATICS AND COMPUTING↗

The Radiation Dose-Response of the Human Spinal Cord

Purpose: To characterize the radiation dose-response of the human spinal cord. Methods and Materials: Because no single institution has sufficient data to establish a dose-response function for the human spinal cord, published reports were combined. Requisite data were dose and fractionation, number of patients at risk, number of myelopathy cases, and survival experience of the population. Eight data points for cervical myelopathy were obtained from five reports. Using maximum likelihood estimation correcting for the survival experience of the population, estimates were obtained for the median tolerance dose, slope parameter, and {alpha}/{beta} ratio in a logistic dose-response function. An adequate fit to thoracic data was not possible. Hyperbaric oxygen treatments involving the cervical cord were also analyzed. Results: The estimate of the median tolerance dose (cervical cord) was 69.4 Gy (95% confidence interval, 66.4-72.6). The {alpha}/{beta} = 0.87 Gy. At 45 Gy, the (extrapolated) probability of myelopathy is 0.03%; and at 50 Gy, 0.2%. The dose for a 5% myelopathy rate is 59.3 Gy. Graphical analysis indicates that the sensitivity of the thoracic cord is less than that of the cervical cord. There appears to be a sensitizing effect from hyperbaric oxygen treatment. Conclusions: The estimate of {alpha}/{beta} is smaller than usually quoted, but values this small were found in some studies. Using {alpha}/{beta} = 0.87 Gy, one would expect a considerable advantage by decreasing the dose/fraction to less than 2 Gy. These results were obtained from only single fractions/day and should not be applied uncritically to hyperfractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Validation of the Updated Partin Tables in a Cohort of French and Italian Men

Purpose: To test the discrimination and calibration properties of the newly developed 2007 Partin Tables in two European cohorts with localized prostate cancer. Methods: Data on clinical and pathologic characteristics were obtained for 1,064 men treated with radical prostatectomy at the Creteil University Health Center in France (n = 839) and at the Milan University Vita-Salute in Italy (n = 225). Overall discrimination was assessed with receiver operating characteristic curve analysis, which quantified the accuracy of stage predictions for each center. Calibration plots graphically explored the relationship between predicted and observed rates of extracapsular extension (ECE), seminal vesicle invasion (SVI) and lymph node invasion (LNI). Results: The rates of ECE, SVI, and LNI were 28%, 14%, and 2% in the Creteil cohort vs. 11%, 5%, and 5% in the Milan cohort. In the Creteil cohort, the accuracy of ECE, SVI, and LNI prediction was 61%, 71%, and 82% vs. 66%, 92% and 75% for the Milan cohort. Important departures were recorded between Partin Tables' predicted and observed rates of ECE, SVI, and LNI within both cohorts. Conclusions: The 2007 Partin Tables demonstrated worse performance in European men than they originally did in North American men. This indicates that predictive models need to be externally validated before their implementation into clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Preliminary Study of In-House Monte Carlo Simulations: An Integrated Monte Carlo Verification System

Purpose: To develop an infrastructure for the integrated Monte Carlo verification system (MCVS) to verify the accuracy of conventional dose calculations, which often fail to accurately predict dose distributions, mainly due to inhomogeneities in the patient's anatomy, for example, in lung and bone. Methods and Materials: The MCVS consists of the graphical user interface (GUI) based on a computational environment for radiotherapy research (CERR) with MATLAB language. The MCVS GUI acts as an interface between the MCVS and a commercial treatment planning system to import the treatment plan, create MC input files, and analyze MC output dose files. The MCVS consists of the EGSnrc MC codes, which include EGSnrc/BEAMnrc to simulate the treatment head and EGSnrc/DOSXYZnrc to calculate the dose distributions in the patient/phantom. In order to improve computation time without approximations, an in-house cluster system was constructed. Results: The phase-space data of a 6-MV photon beam from a Varian Clinac unit was developed and used to establish several benchmarks under homogeneous conditions. The MC results agreed with the ionization chamber measurements to within 1%. The MCVS GUI could import and display the radiotherapy treatment plan created by the MC method and various treatment planning systems, such as RTOG and DICOM-RT formats. Dose distributions could be analyzed by using dose profiles and dose volume histograms and compared on the same platform. With the cluster system, calculation time was improved in line with the increase in the number of central processing units (CPUs) at a computation efficiency of more than 98%. Conclusions: Development of the MCVS was successful for performing MC simulations and analyzing dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Toxicity Grade and Scoring System on the Relationship Between Mean Lung Dose and Risk of Radiation Pneumonitis in a Large Cohort of Patients With Non-Small Cell Lung Cancer

Purpose: To compute the risk of radiation pneumonitis (RP) as a function of mean lung dose (MLD), with RP scored using three grading systems and analyzed at four threshold levels of toxicity in a large cohort of patients with non-small cell lung cancer (NSCLC) treated with definitive radiotherapy (RT). Methods and Materials: On the basis of medical records and radiographic images, RP was scored retrospectively in 442 patients with NSCLC who had {>=}6 months of follow-up after the end of RT. The severity of RP was scored for each patient using the National Cancer Institute (NCI) Common Toxicity Criteria, version 2.0 (CTC2.0); the NCI Common Terminology Criteria for Adverse Events, version 3.0 (CTCAE3.0); and the grading system of the Radiation Therapy Oncology Group (RTOG). For each grading system and for each of four levels of toxicity (Grade {>=}1, {>=}2, {>=}3, {>=}4), the Lyman, logistic, and log-logistic normal tissue complication probability (NTCP) models were fitted to the data as functions of MLD. The parameter estimates from the model fits are listed in table form, and the RP risk estimates are presented graphically for the Lyman and log-logistic NTCP models. Results: The results presented here illustrate the impact of scoring system and level of toxicity on the relationship between MLD and RP risk. Conclusions: These results facilitate quantitative comparisons between our data and studies of RP risk reported by others, and several examples of such comparisons are provided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Validation of a Preoperative Nomogram for Prediction of the Risk of Recurrence After Radical Prostatectomy

Purpose: To test the validity of an updated version of the preoperative Kattan nomogram for prediction of recurrence after radical prostatectomy (RP), published by Stephenson et al. Methods and Materials: We relied on clinical and postoperative prostate-specific antigen follow-up data of 1978 patients treated with open RP at our institution between 1992 and 2006. The accuracy of the nomogram-derived recurrence-free survival predictions were separately tested at 1 to 10 years after RP. Moreover, the relationship between the nomogram-predicted recurrence-free survival rate and the observed recurrence-free survival rate was graphically explored in calibration plots. Results: Median follow-up of censored patients was 32 months. For nomogram-derived recurrence-free survival predictions at 1 to 10 years, the accuracy of the nomogram ranged from 70% to 76%. The calibration between the predicted and observed recurrence-free survival rates was good at 1 and 2 years after RP. However, at all other examined time points, departures from ideal predictions were recorded. Conclusions: Our findings indicate that the preoperative biochemical recurrence nomogram reported by Stephenson et al. can be applied to European patients with good accuracy. However, its calibration was only suboptimal for predictions made 3 or more years after RP, with a tendency to overestimate the probability of recurrence-free survival. This potential limitation should be considered when this tool is applied to European patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breath-Hold Target Localization With Simultaneous Kilovoltage/Megavoltage Cone-Beam Computed Tomography and Fast Reconstruction

Purpose: Hypofractionated high-dose radiotherapy for small lung tumors has typically been based on stereotaxy. Cone-beam computed tomography and breath-hold techniques have provided a noninvasive basis for precise cranial and extracranial patient positioning. The cone-beam computed tomography acquisition time of 60 s, however, is beyond the breath-hold capacity of patients, resulting in respiratory motion artifacts. By combining megavoltage (MV) and kilovoltage (kV) photon sources (mounted perpendicularly on the linear accelerator) and accelerating the gantry rotation to the allowed limit, the data acquisition time could be reduced to 15 s. Methods and Materials: An Elekta Synergy 6-MV linear accelerator, with iViewGT as the MV- and XVI as the kV-imaging device, was used with a Catphan phantom and an anthropomorphic thorax phantom. Both image sources performed continuous image acquisition, passing an angle interval of 90{sup o} within 15 s. For reconstruction, filtered back projection on a graphics processor unit was used. It reconstructed 100 projections acquired to a 512 x 512 x 512 volume within 6 s. Results: The resolution in the Catphan phantom (CTP528 high-resolution module) was 3 lines/cm. The spatial accuracy was within 2-3 mm. The diameters of different tumor shapes in the thorax phantom were determined within an accuracy of 1.6 mm. The signal-to-noise ratio was 68% less than that with a 180{sup o}-kV scan. The dose generated to acquire the MV frames accumulated to 82.5 mGy, and the kV contribution was <6 mGy. Conclusion: The present results have shown that fast breath-hold, on-line volume imaging with a linear accelerator using simultaneous kV-MV cone-beam computed tomography is promising and can potentially be used for image-guided radiotherapy for lung cancer patients in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FDG-PET Assessment of the Effect of Head and Neck Radiotherapy on Parotid Gland Glucose Metabolism

Purpose: Functional imaging with [F-18]-fluorodeoxyglucose positron emission tomography (FDG-PET) provides the opportunity to define the physiology of the major salivary glands before and after radiation therapy. The goal of this retrospective study was to identify the radiation dose-response relationship of parotid gland glucose metabolism in patients with head and neck squamous cell carcinoma (HNSCC). Materials and Methods: Forty-nine adults with HNSCC were identified who had curative intent intensity-modulated radiation therapy (IMRT) and FDG-PET imaging before and after treatment. Using a graphical user interface, contours were delineated for the parotid glands on axial CT slices while all authors were blinded to paired PET slices. Average and maximal standard uptake values (SUV) were measured within these anatomic regions. Changes in SUV and volume after radiation therapy were correlated with parotid gland dose-volume histograms from IMRT plans. Results: The average parotid gland volume was 30.7 mL and contracted 3.9 {+-} 1.9% with every increase of 10 Gy in mean dose (p = 0.04). However, within the first 3 months after treatment, there was a uniform reduction of 16.5% {+-} 7.3% regardless of dose. The average SUV{sub mean} of the glands was 1.63 {+-} 0.48 pretreatment and declined by 5.2% {+-} 2.5% for every increase of 10 Gy in mean dose (p = 0.04). The average SUV{sub max} was 4.07 {+-} 2.85 pretreatment and decreased in a sigmoid manner with mean dose. A threshold of 32 Gy for mean dose existed, after which SUV{sub max} declined rapidly. Conclusion: Radiation dose responses of the parotid glands can be measured by integrated CT/FDG-PET scans. Retrospective analysis showed sigmoidal declines in the maximum metabolism but linear declines in the average metabolism of the glands with dose. Future studies should correlate this decline in FDG uptake with saliva production to improve treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions

Purpose: Gantry-mounted megavoltage electronic portal imaging devices (EPIDs) have become ubiquitous on linear accelerators. WatchDog is a novel application of EPIDs, in which the image frames acquired during treatment are used to monitor treatment delivery in real time. We report on the preliminary use of WatchDog in a prospective study of cancer patients undergoing intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) and identify the challenges of clinical adoption. Methods and Materials: At the time of submission, 28 cancer patients (head and neck, pelvis, and prostate) undergoing fractionated external beam radiation therapy (24 IMRT, 4 VMAT) had ≥1 treatment fraction verified in real time (131 fractions or 881 fields). EPID images acquired continuously during treatment were synchronized and compared with model-generated transit EPID images within a frame time (∼0.1 s). A χ comparison was performed to cumulative frames to gauge the overall delivery quality, and the resulting pass rates were reported graphically during treatment delivery. Every frame acquired (500-1500 per fraction) was saved for postprocessing and analysis. Results: The system reported the mean ± standard deviation in real time χ 91.1% ± 11.5% (83.6% ± 13.2%) for cumulative frame χ analysis with 4%, 4 mm (3%, 3 mm) criteria, global over the integrated image. Conclusions: A real-time EPID-based radiation delivery verification system for IMRT and VMAT has been demonstrated that aims to prevent major mistreatments in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinically Applicable Monte Carlo–based Biological Dose Optimization for the Treatment of Head and Neck Cancers With Spot-Scanning Proton Therapy

Purpose: Our aim is to demonstrate the feasibility of fast Monte Carlo (MC)–based inverse biological planning for the treatment of head and neck tumors in spot-scanning proton therapy. Methods and Materials: Recently, a fast and accurate graphics processor unit (GPU)–based MC simulation of proton transport was developed and used as the dose-calculation engine in a GPU-accelerated intensity modulated proton therapy (IMPT) optimizer. Besides dose, the MC can simultaneously score the dose-averaged linear energy transfer (LET{sub d}), which makes biological dose (BD) optimization possible. To convert from LET{sub d} to BD, a simple linear relation was assumed. By use of this novel optimizer, inverse biological planning was applied to 4 patients, including 2 small and 1 large thyroid tumor targets, as well as 1 glioma case. To create these plans, constraints were placed to maintain the physical dose (PD) within 1.25 times the prescription while maximizing target BD. For comparison, conventional intensity modulated radiation therapy (IMRT) and IMPT plans were also created using Eclipse (Varian Medical Systems) in each case. The same critical-structure PD constraints were used for the IMRT, IMPT, and biologically optimized plans. The BD distributions for the IMPT plans were obtained through MC recalculations. Results: Compared with standard IMPT, the biologically optimal plans for patients with small tumor targets displayed a BD escalation that was around twice the PD increase. Dose sparing to critical structures was improved compared with both IMRT and IMPT. No significant BD increase could be achieved for the large thyroid tumor case and when the presence of critical structures mitigated the contribution of additional fields. The calculation of the biologically optimized plans can be completed in a clinically viable time (<30 minutes) on a small 24-GPU system. Conclusions: By exploiting GPU acceleration, MC-based, biologically optimized plans were created for small–tumor target patients. This optimizer will be used in an upcoming feasibility trial on LET{sub d} painting for radioresistant tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Adaptive Hyperthermia Treatment Planning During Locoregional Heating to Suppress Treatment-Limiting Hot Spots

Background: Adequate tumor temperatures during hyperthermia are essential for good clinical response, but excessive heating of normal tissue should be avoided. This makes locoregional heating using phased array systems technically challenging. Online application of hyperthermia treatment planning could help to improve the heating quality. The aim of this study was to evaluate the clinical benefit of online treatment planning during treatment of pelvic tumors heated with the AMC-8 locoregional hyperthermia system. Methods: For online adaptive hyperthermia treatment planning, a graphical user interface was developed. Electric fields were calculated in a preprocessing step using our in-house–developed finite-difference–based treatment planning system. This allows instant calculation of the temperature distribution for user-selected phase-amplitude settings during treatment and projection onto the patient's computed tomographic scan for online visualization. Online treatment planning was used for 14 treatment sessions in 8 patients to reduce the patients' reports of hot spots while maintaining the same level of tumor heating. The predicted decrease in hot spot temperature should be at least 0.5°C, and the tumor temperature should decrease less than 0.2°C. These predictions were compared with clinical data: patient feedback about the hot spot and temperature measurements in the tumor region. Results: In total, 17 hot spot reports occurred during the 14 sessions, and the alternative settings predicted the hot spot temperature to decrease by at least 0.5°C, which was confirmed by the disappearance of all 17 hot spot reports. At the same time, the average tumor temperature was predicted to change on average −0.01°C (range, −0.19°C to 0.34°C). The measured tumor temperature change was on average only −0.02°C (range, −0.26°C to 0.31°C). In only 2 cases the temperature decrease was slightly larger than 0.2°C, but at most it was 0.26°C. Conclusions: Online application of hyperthermia treatment planning is reliable and very useful to reduce hot spots without affecting tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗