Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

H- Ion Sources for High Intensity Proton Drivers

Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H + and H - ion generation around 3 to 5 mA/cm 2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm 2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

43 PARTICLE ACCELERATORS↗

Temperature peaking at beginning of breakdown in 2.45 GHz pulsed off-resonance electron cyclotron resonance ion source hydrogen plasma

An experimental study of temperature and density evolution during breakdown in off-resonance ECR hydrogen plasma is presented. Under square 2.45 GHz microwave excitation pulses with a frequency of 50 Hz and relative high microwave power, unexpected transient temperature peaks that reach 18 eV during 20 {mu}s are reported at very beginning of plasma breakdown. Decays of such peaks reach final stable temperatures of 5 eV at flat top microwave excitation pulse. Evidence of interplay between incoming power and duty cycle giving different kind of plasma parameters evolutions engaged to microwave coupling times is observed. Under relative high power conditions where short microwave coupling times are recorded, high temperature peaks are measured. However, for lower incoming powers and longer coupling times, temperature evolves gradually to a higher final temperature without peaking. On the other hand, the early instant where temperature peaks are observed also suggest a possible connection with preglow processes during breakdown in ECRIS plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discrimination of ionic species from broad-beam ion sources

The performance of a broad-beam, three-grid, ion extraction system incorporating radio frequency (RF) mass discrimination was investigated experimentally. This testing demonstrated that the system, based on a modified single-stage Bennett mass spectrometer, can discriminate between ionic species having about a 2-to-1 mass ratio while producing a broad-beam of ions with low kinetic energy (less than 15 eV). Testing was conducted using either argon and krypton ions or atomic and diatomic oxygen ions. A simple one-dimensional model, which ignores magnetic field and space-charge effects, was developed to predict the species separation capabilities as well as the kinetic energies of the extracted ions. The experimental results correlated well with the model predictions. This RF mass discrimination system can be used in applications where both atomic and diatomic ions are produced, but a beam of only one of the species is desired. An example of such an application is a 5 eV atomic oxygen source. This source would produce a beam of atomic oxygen with 5 eV kinetic energy, which would be directed onto a material specimen, to simulate the interaction between the surface of a satellite and the rarefied atmosphere encountered in low-Earth orbit.

Anderson, J. R.↗

Photodetachment diagnostics of a volume production type negative ion source with a diode-laser

Time evolution of photodetachment perturbation signal induced by a diode laser was observed in an O{sub 2} plasma. Photodetachment current collected by a Langmuir probe was directly measured and recorded by a digital oscilloscope. After integrating the recorded signal data, the waveform of the photodetachment current showed a time dependence resembling an error function. The waveform had changed its shape in accordance as the position between the probe and the laser beam axis was changed. These characteristics of the photodetachment signal are well explained by a diffusion model. The method has the possibility to yield information on various negative ion containing plasmas, but requires quiescence in the electron saturation current with the fluctuation level less than 10{sup -4}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The NEW DESY RF-Driven Multicusp H{sup -} Ion Source

The HERA RF-Volume source is the only source that can deliver a H{sup -} current of 40 mA without Cs routinely and for periods of several years. Step by step improvements have led to a completely new design. The plasma is now contained in an Al{sub 2}O{sub 3} ceramic chamber and has no contact to metal surfaces except for the collar. The sensitive antenna and also the pair of filter magnets are outside of the plasma. The plasma chamber is mounted in a ceramic disk for high voltage insulation. The ignition of the plasma is done with an ignition source utilizing the higher pressure at the gas input. Details about the setup, performance, H{sup +} containment, sparking suppression and experience with a new 10 cm diameter LEBT will be given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact surface plasma H{sup −} ion source with geometrical focusing

Factors limiting operating lifetime of a Compact Surface Plasma Sources (CSPS) are analyzed and possible treatments for lifetime enhancement are considered. Increased cooling permeate increased discharge power and increased beam intensity and duty factor. A design of an advanced CSPS with geometrical focusing of H{sup −} flux is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion source and low energy injection line for a central region model cyclotron

At CIAE, a 100 MeV H{sup -} cyclotron (CYCIAE-100) is under design and construction. A central region model (CRM) cyclotron was built for various experimental verifications for the CYCIAE-100 project and for research and development of high current injection to accelerate milliampere H{sup -} beam. The H{sup -} multicusp source built in 2003 has been improved recently to make the source operation more stable. A new injection line for axial low energy high current injection has been designed and constructed for the CRM cyclotron.

43 PARTICLE ACCELERATORS↗

A collimator for hot plasma x-ray diagnostics in ion sources

We present a collimator configuration for measuring energy resolved x-ray plasma volume bremsstrahlung emitted, e.g., by an ECRIS. Special attention we paid to shielding the detector against interfering Compton scattered radiation and wall bremsstrahlung stemming from the collimator entrance aperture. We estimate the efficiency for shielding of Compton scattered radiation at least attainable by this arrangement.

43 PARTICLE ACCELERATORS↗

Dependence of the Performance of the Long Pulse RF Driven Negative Ion Source on the Magnetic Filter Field

In the long pulse RF source the plasma drift caused by the magnetic filter field leads to different plasma parameters close to the top and bottom halves of the plasma. In order to investigate the effect of the plasma density on the extracted currents, the bottom grid halve was covered and the direction of the drift was converted by changing the polarity of the magnets. The asymmetry of the plasma density was measured by H{sub {beta}} spectroscopy. By biasing the plasma grid the asymmetry could be enlarged, but the current of co-extracted electrons could be minimized in a similar way for both polarities. The extracted currents of H{sup -} ions as well as of the electrons, however, depend only weakly on the direction of the drift i. e. on the plasma densities. The results indicate that the source performance is determined to a greater degree by the plasma sheath close to the plasma grid which is not yet accessible by diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Workshop on Performance Variations in H- Ion Sources 2012: PV H-12

This paper briefly summarizes a workshop held in Jyvaskyla the day after NIBS 12. The half-day workshop aimed at globally capturing the issue of performance variations in H- sources. There was a focus on production facilities and facilities that work under production like conditions, because there are often high expectations to be met.

cesium↗

Recent performance of the SNS H{sup −} ion source and low-energy beam transport system

Recent measurements of the H{sup −} beam current show that SNS is injecting about 55 mA into the RFQ compared to ∼45 mA in 2010. Since 2010, the H{sup −} beam exiting the RFQ dropped from ∼40 mA to ∼34 mA, which is sufficient for 1 MW of beam power. To minimize the impact of the RFQ degradation, the service cycle of the best performing source was extended to 6 weeks. The only degradation is fluctuations in the electron dump voltage towards the end of some service cycles, a problem that is being investigated. Very recently, the RFQ was retuned, which partly restored its transmission. In addition, the electrostatic low-energy beam transport system was reengineered to double its heat sinking and equipped with a thermocouple that monitors the temperature of the ground electrode between the two Einzel lenses. The recorded data show that emissions from the source at high voltage dominate the heat load. Emissions from the partly Cs-covered first lens cause the temperature to peak several hours after starting up. On rare occasions, the temperature can also peak due to corona discharges between the center ground electrode and one of the lenses.

43 PARTICLE ACCELERATORS↗

Final design of thermal diagnostic system in SPIDER ion source

The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H{sup −} production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density matrix in technique of polarized ion sources

The use of the density matrix is the most direct way to work with polarization parameters. The solutions of the equation for the density matrix are obtained for hydrogen and deuterium. The magnetic moments of nuclei are explicitly incorporated into the equations, even though numerically it does not make a big difference. It is shown that in the general case the density matrix can not be reduced to the one with the only spin variables of the nucleus in contradiction with the statement of K. Blum [K. Blum, Density Matrix Theory and Applications].

43 PARTICLE ACCELERATORS↗

Radio frequency ion source operated with field effect transistor based radio frequency system

Characteristics of radio frequency (RF) plasma production are investigated using a field effect transistor inverter power supply as an RF wave source. With the frequency of around 0.3 MHz, an electron density over 10{sup 18} m{sup -3} is produced in argon plasma. Although lower densities are obtained in hydrogen plasma, it drastically increased up to 5x10{sup 18} m{sup -3} with an axial magnetic field of around 100 G applied in the driver region. Effects of the magnetic field and gas pressure are investigated in the RF produced plasma with the frequency of several hundred kilohertz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical and experimental study of atomic transport and Balmer line intensity in Linac4 negative ion source

Time structure of Balmer H{sub α} line intensity in Linac4 RF plasma has been analyzed by the combined simulation model of atomic transport and Collisional-Radiative models. As a preliminary result, time variation of the line intensity in the ignition phase of RF plasma is calculated and compared with the experimental results by photometry. For the comparison, spatial distribution of the local H{sub α} photon emission rate at each time is calculated from the numerical model. The contribution of the local photon emission rates to the observed line intensity via optical viewing port is also investigated by application of the mock-up of the optical viewing port and the known light source. It has been clarified from the analyses that the higher and the lower peaks of the H{sub α} line intensity observed during 1 RF cycle is mainly due to the different spatial distributions in the electron energy distribution function and the resultant local photon emission rate. These results support previous suggestion that the existence of the capacitive electric field in axial direction leads to the higher/lower peaks of the line intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 3D Monte Carlo code for the modeling of plasma dynamics and beam formation mechanism in electron cyclotron resonance ion sources

The code here presented is the first part of a Monte Carlo (MC) self-consistent 3D plasma simulator. It is yet able to solve the equation of motion for thousands of independent charged particles. The procedure allows to understand the consequences of each phenomenon introduced in the evolution steps of the code. MC random selection of starting parameters is used for each particles; the environmental conditions enclosed in the simulation are ECRIS magnetic field, resonant electromagnetic wave, initial plasma density distribution and MC calculation of Spitzer collision. The results of the first simulations explain some typical effects as the hollow beam formation and the main plasma deconfinement mechanism.

43 PARTICLE ACCELERATORS↗

Inductively driven surface-plasma negative ion source for N-NBI use (invited)

The long-pulse surface-plasma source prototype is developed at Budker Institute of Nuclear Physics for negative-ion based neutral beam injector use. The essential source features are (1) an active temperature control of the ion-optical system electrodes by circulation of hot thermal fluid through the channels, drilled in the electrode bodies, (2) the concaved transverse magnetic field in the extraction and acceleration gaps, preventing the electrons trapping and avalanching, and (3) the directed cesium deposition via distribution tubes adjacent to the plasma grid periphery. The long term effect of cesium was obtained just with the single cesium deposition. The high voltage strength of ion-optical system electrodes was improved with actively heated electrodes. A stable H{sup −} beam with a current ∼1 A and energy 90 keV was routinely extracted and accelerated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Multi-cusp Magnetic Field in Cylindrical Geometry for H{sup -} Ion Source

The computation of magnetic field generated by the permanent magnets (PM) in the multipole configuration in a cylindrical geometry has been carried out analytically and compared with the experimental measurements. It has been shown that the magnetic field intensity variation inside the cylindrical plasma chamber follows a power law functional form rather than the conventionally used exponential functional form. The measurement of magnetic field inside the cylindrical multicusp geometry has been performed using a Hall probe method with 3-D motorized movement bench which shows excellent agreement with the analytical calculations. A detailed analytical computations of multi-cusp magnetic field for the cylindrical geometry and its comparison with the conventional exponential functional form has been presented.

43 PARTICLE ACCELERATORS↗