Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Analyzing the properties of acceptor mode in two-dimensional plasma photonic crystals based on a modified finite-difference frequency-domain method

In this paper, the properties of acceptor mode in two-dimensional plasma photonic crystals (2D PPCs) composed of the homogeneous and isotropic dielectric cylinders inserted into nonmagnetized plasma background with square lattices under transverse-magnetic wave are theoretically investigated by a modified finite-difference frequency-domain (FDFD) method with supercell technique, whose symmetry of every supercell is broken by removing a central rod. A new FDFD method is developed to calculate the band structures of such PPCs. The novel FDFD method adopts a general function to describe the distribution of dielectric in the present PPCs, which can easily transform the complicated nonlinear eigenvalue equation to the simple linear equation. The details of convergence and effectiveness of proposed FDFD method are analyzed using a numerical example. The simulated results demonstrate that the enough accuracy of the proposed FDFD method can be observed compared to the plane wave expansion method, and the good convergence can also be obtained if the number of meshed grids is large enough. As a comparison, two different configurations of photonic crystals (PCs) but with similar defect are theoretically investigated. Compared to the conventional dielectric-air PCs, not only the acceptor mode has a higher frequency but also an additional photonic bandgap (PBG) can be found in the low frequency region. The calculated results also show that PBGs of proposed PPCs can be enlarged as the point defect is introduced. The influences of the parameters for present PPCs on the properties of acceptor mode are also discussed in detail. Numerical simulations reveal that the acceptor mode in the present PPCs can be easily tuned by changing those parameters. Those results can hold promise for designing the tunable applications in the signal process or time delay devices based on the present PPCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ordering of Trotterization: Impact on Errors in Quantum Simulation of Electronic Structure

Trotter–Suzuki decompositions are frequently used in the quantum simulation of quantum chemistry. They transform the evolution operator into a form implementable on a quantum device, while incurring an error—the Trotter error. The Trotter error can be made arbitrarily small by increasing the Trotter number. However, this increases the length of the quantum circuits required, which may be impractical. It is therefore desirable to find methods of reducing the Trotter error through alternate means. The Trotter error is dependent on the order in which individual term unitaries are applied. Due to the factorial growth in the number of possible orderings with respect to the number of terms, finding an optimal strategy for ordering Trotter sequences is difficult. In this paper, we propose three ordering strategies, and assess their impact on the Trotter error incurred. Initially, we exhaustively examine the possible orderings for molecular hydrogen in a STO-3G basis. We demonstrate how the optimal ordering scheme depends on the compatibility graph of the Hamiltonian, and show how it varies with increasing bond length. We then use 44 molecular Hamiltonians to evaluate two strategies based on coloring their incompatibility graphs, while considering the properties of the obtained colorings. We find that the Trotter error for most systems involving heavy atoms, using a reference magnitude ordering, is less than 1 kcal/mol. Relative to this, the difference between ordering schemes can be substantial, being approximately on the order of millihartrees. The coloring-based ordering schemes are reasonably promising—particularly for systems involving heavy atoms—however further work is required to increase dependence on the magnitude of terms. Finally, we consider ordering strategies based on the norm of the Trotter error operator, including an iterative method for generating the new error operator terms added upon insertion of a term into an ordered Hamiltonian.

97 MATHEMATICS AND COMPUTING↗

Retrofitting stoves with forced jets of primary air improves speed, emissions, and efficiency: Evidence from six types of biomass cookstoves

Incorporating jets of forced air into biomass cookstove combustion has been shown to potentially decrease harmful emissions, leading to a variety of designs in recent years. These have shown mixed success in terms of real-world performance, usability, and durability. The Jet-Flame forced draft retrofit accessory was recently developed to implement forced jets of primary air at a low cost into a wide range of types of cookstoves using a small 1.5-W fan housed in a low-cost cast iron body to be inserted beneath the fuel bed of a biomass cooking fire. This research sought to quantify the potential efficiency and emissions performance impacts of the Jet-Flame when installed in six different types of biomass cookstoves (three open or shielded fires and three rocket stoves) versus the natural draft performance of each. The effect of the operating fan voltage was also measured. A series of tests following a modified ISO 19867-1:2018 protocol were performed in the laboratory using the Aprovecho Laboratory Emissions Measurement System (LEMS) equipped with additional oxygen and temperature sensors. Results for each stove carefully tended with a single layer of sticks showed that the global average PM 2.5 reduction with the Jet-Flame was 89 % relative to the natural draft cases, with larger relative improvements seen in the most rudimentary stoves. CO was reduced by a global average of 74 %, reaching tier 4 or 5 for all stoves. Thermal efficiency was also improved by 34 % when calculated without taking into account the energy content of the remaining char (or 21 % with char), illustrating the value of burning char to provide cooking energy rather than leaving it unburned in the combustion chamber as is common in many natural draft stoves. Time to boil was also reduced by 8 %. In addition, adjusting the voltage of the jet-flame assisted in modulating firepower, improving the usability of the stove. These results indicate a strong potential for the Jet-Flame to help reduce emissions and fuel consumption in a wide range of cookstove designs at a relatively low cost or need for changes in behavior, fuel, or cooking device. The unit also provides enhanced usability in terms of ease of startup, cooking speed, low PM emissions at high power, and burning char. Additional studies are needed to measure performance in the field and under a variety of operational conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Loss, High-Isolation Microwave Microelectromechanical Systems (MEMS) Switches Being Developed

Switches, electrical components that either permit or prevent the flow of electricity, are the most important and widely used electrical devices in integrated circuits. In microwave systems, switches are required for switching between the transmitter and receiver; in communication systems, they are needed for phase shifters in phased-array antennas, for radar and communication systems, and for the new class of digital or software definable radios. Ideally, switches would be lossless devices that did not depend on the electrical signal's frequency or power, and they would not consume electrical power to change from OFF to ON or to maintain one of these two states. Reality is quite different, especially at microwave frequencies. Typical switches in microwave integrated circuits are pin diodes or gallium arsenide (GaAs) field-effect transistors that are nonlinear, with characteristics that depend on the power of the signal. In addition, they are frequency-dependent, lossy, and require electrical power to maintain a certain state. A new type of component has been developed that overcomes most of these technical difficulties. Microelectromechanical (MEMS) switches rely on mechanical movement as a response to an applied electrical force to either transmit or reflect electrical signal power. The NASA Glenn Research Center has been actively developing MEMS for microwave applications for over the last 5 years. Complete fabrication procedures have been developed so that the moving parts of the switch can be released with near 100-percent yield. Moreover, the switches fabricated at Glenn have demonstrated state-of-the-art performance. A typical MEMS switch is shown. The switch extends over the signal and ground lines of a finite ground coplanar waveguide, a commonly used microwave transmission line. In the state shown, the switch is in the UP state and all the microwave power traveling along the transmission line proceeds unimpeded. When a potential difference is applied between the cantilever and the transmission line, the cantilever is pulled downward until it connects the signal line to the ground planes, creating a short circuit. In this state, all the microwave power is reflected. The graph shows the measured performance of the switch, which has less than 0.1 dB of insertion loss and greater than 30dB of isolation. These switches consume negligible electrical power and are extremely linear. Additional research is required to address reliability and to increase the switching speed.

Ponchak, George E.↗

Viscous Heating At Stagnation In Z-Pinches

The viscous heating associated with m = 0 MHD instabilities in the stagnated Z-pinch is developed further. It would appear that the larger numerical (Neumann) viscosity plus De Bar corrections in simulation codes to yield energy conservation might be another way of representing viscous heating, but in this case the viscosity is inserted to smooth shock discontinuities. However the viscous heating per unit volume appears to be independent of the coefficient of viscosity itself because the fastest growing MHD mode is itself determined by the viscous damping. Therefore it could be argued that, though the correct physics is not in the codes, the resulting heating is not sensitive to the fact that numerical viscosity instead is employed. In addition, by chance, the model of magnetic bubbles first introduced by Lovberg et al. and Riley et al., and later by Rudakov et al. to explain phenomenologically extra heating of the ions leads to the same heating rate as in Haines et al. For the stainless steel array in which T{sub i} was predicted and measured to be >200 KeV while T{sub e} = 3 KeV the ion viscous heating is dominant. However, for the low current experiment by Kroupp et al. in which the ion kinematic viscosity is much smaller than the resistive diffusivity there is resistive damping of MHD modes, and no ions viscous heating should be expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ka-Band Waveguide Two-Way Hybrid Combiner for MMIC Amplifiers

The design, simulation, and characterization of a novel Ka-band (32.05 0.25 GHz) rectangular waveguide two-way branch-line hybrid unequal power combiner (with port impedances matched to that of a standard WR-28 waveguide) has been created to combine input signals, which are in phase and with an amplitude ratio of two. The measured return loss and isolation of the branch-line hybrid are better than 22 and 27 dB, respectively. The measured combining efficiency is 92.9 percent at the center frequency of 32.05 GHz. This circuit is efficacious in combining the unequal output power from two Ka-band GaAs pseudomorphic high electron mobility transistor (pHEMT) monolithic microwave integrated circuit (MMIC) power amplifiers (PAs) with high efficiency. The component parts include the branch-line hybrid-based power combiner and the MMIC-based PAs. A two-way branch-line hybrid is a four-port device with all ports matched; power entering port 1 is divided in phase, and into the ratio 2:1 between ports 3 and 4. No power is coupled to port 2. MMICs are a type of integrated circuit fabricated on GaAs that operates at microwave frequencies, and performs the function of signal amplification. The power combiner is designed to operate over the frequency band of 31.8 to 32.3 GHz, which is NASA's deep space frequency band. The power combiner would have an output return loss better than 20 dB. Isolation between the output port and the isolated port is greater than 25 dB. Isolation between the two input ports is greater than 25 dB. The combining efficiency would be greater than 90 percent when the ratio of the two input power levels is two. The power combiner is machined from aluminum with E-plane split-block arrangement, and has excellent reliability. The flexibility of this design allows the combiner to be customized for combining the power from MMIC PAs with an arbitrary power output ratio. In addition, it allows combining a low-power GaAs MMIC with a high-power GaN MMIC. The arbitrary port impedance allows matching the output impedance of the MMIC PA directly to the waveguide impedance without transitioning first into a transmission line with characteristic impedance of 50 ohms. Thus, by eliminating the losses associated with a transition, the overall SSPA efficiency is enhanced. For reducing the cost and weight when required in very large quantities, such as in the beam-forming networks of phased-array antenna systems, the combiner can be manufactured using metal-plated plastic. Two hybrid unequal power combiners can be cascaded to realize a non-binary combiner (for e.g., a three-way) and can be synergistically optimized for low VSWR (voltage standing wave ratio), low insertion loss, high isolation, and wide bandwidth using commercial off-the-shelf electromagnetic software design tools.

Simons, Rainee N.↗

Fast scanning probe for the NSTX spherical tokamak

We describe a fast reciprocating Langmuir probe and drive system, which has four main new features: (1) use of high-temperature, vacuum, circuit boards instead of cables to reduce weight and increase to 21 the number of possible connections, (2) rotatable and removable shaft, (3) 10 tip construction with designed hardware bandwidth up to 10 MHz, and (4) a detachable and modular tip assembly for easy maintenance. The probe is mounted in a fast pneumatic drive capable of speeds {approx}7 m/s and {approx}20g's acceleration in order to reach the scrape-off layer (SOL) and pedestal regions and remain inserted long enough to obtain good statistics while minimizing the heat deposition to the tips and head in a power density environment of 1-10 MW/m{sup 2}. The National Spherical Torus Experiment SOL features electron temperature, T{sub e}{approx}10-30 eV, and electron density, n{sub e}{approx}0.1-5x10{sup 12} cm{sup -3} while the pedestal features n{sub e}{approx}0.5-1.5x10{sup 13} cm{sup -3} and T{sub e}{approx}30-150 eV. The probe described here has ten tips which obtain a wide spectrum of plasma parameters: electron temperature profile T{sub e}(r), electron density profile n{sub e}(r) and Mach number profile M(r), floating potential V{sub f}(r), poloidal and radial electric field profiles E{sub {theta}}(r) and E{sub {rho}}(r), saturation current profile I{sub sat}(r), and their fluctuations up to 3 MHz. We describe the probe and show representative radial profiles of various parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of InGaAs interlayer on the properties of GaAs grown on Si (111) substrate by molecular beam epitaxy

High-quality GaAs films have been epitaxially grown on Si (111) substrates by inserting an In{sub x}Ga{sub 1−x}As interlayer with proper In composition by molecular beam epitaxy (MBE). The effect of In{sub x}Ga{sub 1−x}As (0 < x < 0.2) interlayers on the properties of GaAs films grown on Si (111) substrates by MBE has been studied in detailed. Due to the high compressive strain between InGaAs and Si, InGaAs undergoes partial strain relaxation. Unstrained InGaAs has a larger lattice constant than GaAs. Therefore, a thin InGaAs layer with proper In composition may adopt a close lattice constant with that of GaAs, which is beneficial to the growth of high-quality GaAs epilayer on top. It is found that the proper In composition in In{sub x}Ga{sub 1−x}As interlayer of 10% is beneficial to obtaining high-quality GaAs films, which, on the one hand, greatly compensates the misfit stress between GaAs film and Si substrate, and on the other hand, suppresses the formation of multiple twin during the heteroepitaxial growth of GaAs film. However, when the In composition does not reach the proper value (∼10%), the In{sub x}Ga{sub 1−x}As adopts a lower strain relaxation and undergoes a lattice constant smaller than unstrained GaAs, and therefore introduces compressive stress to GaAs grown on top. When In composition exceeds the proper value, the In{sub x}Ga{sub 1−x}As will adopt a higher strain relaxation and undergoes a lattice constant larger than unstrained GaAs, and therefore introduces tensile stress to GaAs grown on top. As a result, In{sub x}Ga{sub 1−x}As interlayers with improper In composition introduces enlarged misfit stress to GaAs epilayers grown on top, and deteriorates the quality of GaAs epilayers. This work demonstrates a simple but effective method to grow high-quality GaAs epilayers and brings up a broad prospect for the application of GaAs-based optoelectronic devices on Si substrates.

36 MATERIALS SCIENCE↗

SU-G-BRB-09: Kompeito-Shot: Development of a Novel Verification System for 3D Beam Alignment Including the Sag of Gantry Head

Purpose: High accuracy of beam axis is required for high-precision radiation therapy. It is impossible to quantitatively and directly evaluate the sagging effect of the gantry head using current methods (star-shot and Winston-Lutz tests) when the gantry head sags under the weight of MLC and X-Y jaws. We introduce a novel method “Kompeito-shot (3D star-shot)” for the verification of 3D beam alignment (3D isocentricity). This method enables direct measurement of the sagging effect. We developed the system and examined the concept of this system. Methods: The system composed of a plastic scintillator (PS), a truncated cone-shaped mirror, a plane mirror and a CCD camera. Two types of PS were compared. One consisted of a column PS (Co system), the other consisted of a column PS inserted into a barrel PS with shading film in between (Co-Ba system). The system was irradiated with a 6-MV photon beam and the scintillation light was measured using the CCD camera through the mirror system. The gantry angle was set from 270 to 300 degrees to mimic the sagging of the gantry head for evaluating the accuracy of the system. The distance between a center of PS and entrance / exit points were calculated to analyze the gantry angle. And, the calculated gantry angle and the irradiated gantry angle were compared. Results: We compared the measured image of Co system and that of Co-Ba system. Entrance and exit areas were visualized clearly. The histogram showing the difference between the calculated gantry angle and the irradiated gantry angle was fitted with a Gaussian function. Mean and standard deviation of Co-Ba system were smaller than that of Co system by one order of magnitude. Conclusion: We developed the Kompeito-shot system and evaluated the accuracy of the system. The basic concept works for the verification of 3D isocentricity.

60 APPLIED LIFE SCIENCES↗

Quantification of Electrochemical Nanoscale Processes in Lithium Batteries By OperandoEC-(S)TEM

Lithium (Li)-ion batteries are currently used for a wide variety of portable electronic devices, electric vehicles and renewable energy applications. In addition, extensive worldwide research efforts are now being devoted to more advanced “beyond Li-ion” battery chemistries - such as lithium-sulfur (Li-S) and lithium-air (Li-O2) - in which the carbon anode is replaced with Li metal. However, the practical application of Li metal anode systems has been highly problematic. The main challenges involve controlling the formation of a solid-electrolyte interphase (SEI) layer and the suppression of Li dendrite growth during the charge/discharge process (achieving “dendrite-free” cycling). The SEI layer formation continuously consumes the electrolyte components creating highly resistive layer, which leads to the rapid decrease of cycling performance and degradation of the Li anode. The growth of Li metal dendrites at the anode contributes to rapid capacity fading (the presence of “dead Li” created during the discharge leads to an increased overpotential) and, in the case of continuous growth, leads to internal short circuits and extreme safety issues. Here we demonstrate the application of an operando electrochemical scanning transmission electron microscopy (ec-(S)TEM) cell to study the SEI layer formation and the initial stages of Li dendrite growth - the goal is to develop a mechanism for mitigating the degradation processes and increasing safety. Bright field (BF) STEM images in Figure 1 A-C show Li metal deposition and dissolution processes at the interface between the Pt working electrode and the lithium hexafluorophosphate (LiPF6) in propylene carbonate (PC) electrolyte during three charge/discharge cycles. A contrast reversal caused by Li metal being lighter/less dense than surrounding electrolyte (Li appears brighter than the background in BF STEM images) allows Li to be uniquely identified from the other components in the system - the only solid material that is less dense than the electrolyte is Li metal. Using these images, we can precisely quantify the total volume of Li deposition, the thickness of the SEI layer (observed as a ring of positive contrast around the electrode) and alloy formation due to Li+ ion insertion during each cycle. Furthermore, at the end of each discharge cycle we can quantify the presence of “dead Li” detached from the Pt electrode, thereby demonstrating the degree of irreversibility (and degradation of Pt electrode) associated with insertion/removal of Li+during this process with direct correlation to electrochemical performance. Such analyses provide significant insights into Li metal dendrite growth, which is critical to understand the complex interfacial reactions needed to be controlled for future Li-based and next generation energy storage systems.

batteries↗

Single-Event Gate Rupture in Power MOSFETs: A New Radiation Hardness Assurance Approach

Almost every space mission uses vertical power metal-semiconductor-oxide field-effect transistors (MOSFETs) in its power-supply circuitry. These devices can fail catastrophically due to single-event gate rupture (SEGR) when exposed to energetic heavy ions. To reduce SEGR failure risk, the off-state operating voltages of the devices are derated based upon radiation tests at heavy-ion accelerator facilities. Testing is very expensive. Even so, data from these tests provide only a limited guide to on-orbit performance. In this work, a device simulation-based method is developed to measure the response to strikes from heavy ions unavailable at accelerator facilities but posing potential risk on orbit. This work is the first to show that the present derating factor, which was established from non-radiation reliability concerns, is appropriate to reduce on-orbit SEGR failure risk when applied to data acquired from ions with appropriate penetration range. A second important outcome of this study is the demonstration of the capability and usefulness of this simulation technique for augmenting SEGR data from accelerator beam facilities. The mechanisms of SEGR are two-fold: the gate oxide is weakened by the passage of the ion through it, and the charge ionized along the ion track in the silicon transiently increases the oxide electric field. Most hardness assurance methodologies consider the latter mechanism only. This work demonstrates through experiment and simulation that the gate oxide response should not be neglected. In addition, the premise that the temporary weakening of the oxide due to the ion interaction with it, as opposed to due to the transient oxide field generated from within the silicon, is validated. Based upon these findings, a new approach to radiation hardness assurance for SEGR in power MOSFETs is defined to reduce SEGR risk in space flight projects. Finally, the potential impact of accumulated dose over the course of a space mission on SEGR susceptibility is explored. SEGR evaluation of gamma-irradiated power MOSFETs suggests a non-significant SEGR susceptibility enhancement due to accumulated dose from gamma rays. During SEGR testing, an unexpected enhanced dose effect from heavy-ion irradiation was detected. We demonstrate that this effect could be due to direct ionization by two or more ions at the same channel location. The probability on-orbit for such an occurrence is near-zero given the low heavy-ion fluence over a typical mission lifetime, and did not affect SEGR susceptibility. The results of this work can be used to bound the risk of SEGR in power MOSFETs considered for insertion into spacecraft and instruments.

Lauenstein, Jean-Marie↗

SU-E-I-60: Quality Assurance Testing Methods and Customized Phantom for Magnetic Resonance Imaging and Spectroscopy

Purpose: The objectives of this study are to develop an magnetic resonance imaging and spectroscopy (MRI-MRS) fused phantom along with the inserts for metabolite quantification and to conduct quantitative analysis and evaluation of the layered vials of brain-mimicking solution for quality assurance (QA) performance, according to the localization sequence. Methods: The outer cylindrical phantom body is made of acrylic materials. The section other than where the inner vials are located was filled with copper sulfate and diluted with water so as to reduce the T1 relaxation time. Sodium chloride was included to provide conductivity similar to the human body. All measurements of MRI and MRS were made using a 3.0 T scanner (Achiva Tx 3.0 T; Philips Medical Systems, Netherlands). The MRI scan parameters were as follows: (1) spin echo (SE) T1-weighted image: repetition time (TR), 500ms; echo time (TE), 20ms; matrix, 256×256; field of view (FOV), 250mm; gap, 1mm; number of signal averages (NSA), 1; (2) SE T2-weighted image: TR, 2,500 ms; TE, 80 ms; matrix, 256×256; FOV, 250mm; gap, 1mm; NSA, 1; 23 slice images were obtained with slice thickness of 5mm. The water signal of each volume of interest was suppressed by variable pulse power and optimized relaxation delays (VAPOR) applied before the scan. By applying a point-resolved spectroscopy sequence, the MRS scan parameters were as follows: voxel size, 0.8×0.8×0.8 cm{sup 3}; TR, 2,000ms; TE, 35ms; NSA, 128. Results: Using the fused phantom, the results of measuring MRI factors were: geometric distortion, <2% and ±2 mm; image intensity uniformity, 83.09±1.33%; percent-signal ghosting, 0.025±0.004; low-contrast object detectability, 27.85±0.80. In addition, the signal-to-noise ratio of N-acetyl-aspartate was consistently high (42.00±5.66). Conclusion: The MRI-MRS QA factors obtained simultaneously using the phantom can facilitate evaluation of both images and spectra, and provide guidelines for obtaining MRI and MRS QA factors simultaneously. This study was supported by grant (2012-007883 and 2014R1A2A1A10050270) from the Mid-career Researcher Program through the NRF funded by Ministry of Science. In addition, this study was supported by the Industrial R&D of MOTIE/KEIT (10048997, Development of the core technology for integrated therapy devices based on real-time MRI-guided tumor tracking)

60 APPLIED LIFE SCIENCES↗

Infections in patients using ventricular-assist devices: Comparison of the diagnostic performance of {sup 18}F-FDG PET/CT scan and leucocyte-labeled scintigraphy

Background: The usage of left-ventricular-assist device (LVAD) is increasing in patients presenting with advanced heart failure. However, device-related infections are a challenge to recognize and to treat, with an important morbidity and mortality rate. The role of nuclear medicine imaging remains not well established for LVAD infections. The present study compared the accuracy of positron emission tomography/computed tomography with {sup 18}F-fludeoxyglucose ({sup 18}F-FDG PET/CT) and radiolabeled leucocyte scintigraphy for the diagnosis of infections in patients supported with a continuous-flow LVAD. Methods: From a prospectively maintained database, we retrospectively analyzed the diagnostic performance of radiolabeled leucocyte scintigraphy and {sup 18}F-FDG PET/CT in 24 patients who had a LVAD with a suspected device-related infection. Both examinations were routinely performed in all patients. Infection was assessed by the International Society for Heart and Lung Transplantation criteria. Results: Twenty-four patients were included: 15 had a specific VAD infection (5 cardiac-LVAD and 10 driveline), 6 had a VAD-related infection, while 3 patients had a non-VAD-related infection. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.2%, 66.7%, 95.2%, 66.7%, and 91.6%, respectively, for {sup 18}F-FDG-PET; and 71.4%, 100%, 100%, 33.3%, and 75%, respectively, for leucocyte scintigraphy. {sup 18}F-FDG PET/CT showed significantly higher sensitivity (P = 0.01) than leucocyte scintigraphy. Conclusion: {sup 18}F-FDG PET/CT and radiolabeled leucocyte scintigraphy single-photon emission computed tomography carry high performance in the diagnostic of LVAD infections. {sup 18}F-FDG PET/CT shows significantly higher sensitivity and could be proposed as first-line nuclear medicine procedure. [French] French Abstract: Contexte: L’utilisation du dispositif d’assistance ventriculaire gauche (DAVG) est en utilisation croissante chez les patients avec insuffisance cardiaque avancée. Cependant, les infections liées au dispositif sont un défi à reconnaître et à traiter en raison d’ un taux de morbidité et de mortalité important. Le rôle de l’imagerie de médecine nucléaire n’est pas encore bien établi pour les infections secondaires au DAVG. La présente étude compare la précision de la tomographie par émission de positrons / tomodensitométrie au 18F-fluorodéoxyglucose (18F-FDG TEP/TDM) et la scintigraphie leucocytaire radio-marquée pour le diagnostic d’infections chez des patients porteurs par un DAVG à flux continu. Méthodes: A partir d’une base de données complétée de manière prospective nous avons analysé rétrospectivement les performances diagnostiques de la scintigraphie leucocytaire radio-marquée et de la TEP / TDM au 18F-FDG chez 24 patients ayant un DAVG avec une infection suspectée liée à l’appareillage. Les deux types d’examens scintigraphiques ont été systématiquement réalisé chez tous les patients. Le diagnostic d’infection fut établi selon les critères ISHLT. Résultats: Parmi les 24 patients inclus, 15 avaient une infection spécifique de l’appareillage AVG (5 au niveau de la pompe et/ou canule d’insertion myocardique) et 10 au niveau du driveline, 6 avaient une infection indirectement liée à l’appareillage AVG, tandis que 3 patients avaient une infection non liée au DAVG. La sensibilité, la spécificité, la valeur prédictive positive, la valeur prédictive négative et la précision étaient de 95,2%, 66,7%, 95,2%, 66,7% et 91,6%, respectivement, pour le 18F-FDG-PET et 71,4%, 100%, 100%, 33,3 %, et 75%, respectivement, pour la scintigraphie leucocytaire. La TEP / TDM au 18F-FDG a montré une sensitivité significativement plus élevée (p = 0,01) que la scintigraphie leucocytaire. Conclusion: 18F-FDG TEP/TDM et scintigraphie leucocytaire radio-marquée SPECT s’avèrent très efficaces pour le diagnostic des infections à DVAG. La TEP/TDM au 18F-FDG montre une sensibilité significativement plus élevée et pourrait être proposée en tant que la procédure de médecine nucléaire de premier choix. [Spanish] Spanish Abstract: Antecedentes: El uso de dispositivos de asistencia ventricular izquierda (DAVI) está incrementando en pacientes con insuficiencia cardiaca avanzada. Sin embargo, las infecciones relacionadas al dispositivo representan un reto diagnóstico y de tratamiento, con una importante tasa de morbilidad y mortalidad. El papel de los estudios de imagen de medicina nuclear en las infecciones de DAVI no se ha establecido claramente. El presente estudio comparó la precisión de la tomografía por emisión de positrones/tomografía computada con {sup 18}F-fluorodesoxiglucosa ({sup 18}F-FDG PET/CT) y la gammagrafía con leucocitos marcados para el diagnóstico de infecciones en pacientes utilizando un DAVI de flujo continuo. Métodos: Desde una base de datos obtenida de manera prospectiva, analizamos de manera retrospectiva el rendimiento diagnóstico de la gammagrafía de leucocitos marcados y del {sup 18}F-FDG PET/CT en 24 pacientes quienes tenían un DAVI con sospecha de infección relacionada al dispositivo. Ambos estudios fueron realizados rutinariamente en todos los pacientes. Se determinó la presencia de infección mediante los criterios de la ISHTL. Resultados: Se incluyeron veinticuatro pacientes, de los cuales 15 tuvieron una infección específica de DAV (5 con infecciones DAVI, y 10 con infección del driveline), 6 tuvieron una infección relacionada al DAV, y 3 pacientes tuvieron una infección no relacionada al DAV. La sensibilidad, especificidad, valor predictivo positivo, valor predictivo negativo y precisión diagnóstica fueron 95.2%, 66.7%, 95.2%, 66.7% y 91.6%, respectivamente para {sup 18}F-FDG PET/CT, y 71.4%, 100%, 100%, 33.3% y 75%, respectivamente para la gammagrafía de leucocitos marcados. El {sup 18}F-FDG PET/CT mostró una significativa mayor sensibilidad (p=0.01) que la gammagrafía con leucocitos marcados. Conclusión: El {sup 18}F-FDG PET/CT y la gammagrafía de leucocitos marcados tienen un alto desempeño en el diagnóstico de infecciones de DAVI. El {sup 18}F-FDG PET/CT muestra una significativa mayor sensibilidad y podría ser propuesto como el procedimiento de medicina nuclear de primera línea. [Chinese] Chinese Abstract: 背景: 左心室辅助装置 (LVAD) 越来越多的应用于重度心力衰竭患者。然而, 设备相关的感染有着重要的发病率和死亡率, 并且对其诊断和治疗均是一项挑战。对于 LVAD 相关感染, 核医学影像可扮演的角色一直没有完善。本研究针对装备有连续流式 LVAD 的感染病人,对比了 {sup 18}F-FDG PET/CT 造影术和放射性标记白细胞闪烁扫描法对感染诊断的准确性。 方法: 从一个前瞻性的数据库, 入选了24名疑似设备感染的 LVAD 病人, 并回顾性的分析了放射性标记白细胞闪烁扫描法和 {sup 18}F-FDG PET/CT 的诊断表现。所有病人都常规进行了上述两种检查。利用 ISHLT 标准对感染情况进行评估。 结果: 在入选的 24 名病人中, 15 名有明确的 VAD 感染 (5 名心脏的 LVAD 和 10 名动力传动系统装置), 6 名有 VAD 相关的感染,另外3名有 VAD 无关的感染。对于 {sup 18}F-FDG PET/CT 诊断方法,其敏感性,特异性,阳性预测值,阴性预测值和准确率分别为: 95.2%, 66.7%, 95.2%, 66.7%, 和 91.6%; 而对于白细胞闪烁扫描诊断方法, 其敏感性, 特异性, 阳性预测值,阴性预测值和准确率分别为: 71.4%, 100%, 100%, 33.3% 和 75%。相比于白细胞闪烁扫描, {sup 18}F-FDG PET/CT 明显展现出较高的敏感性 (p=0.01)。 结论: {sup 18}F-FDG PET/CT 和白细胞闪烁扫描 SPECT 对于 LVAD 感染的诊断具有很好的表现。{sup 18}F-FDG PET/CT 展现出较高的敏感性,可以作为核医学的首要检查。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measuring, Cutting and Sorting Irradiated Control Rods to Limit the Volume of Intermediate Level Long-lived Waste - 17001

During operation, the PWR control rods are either completely extracted (scram or safety rods) or partially inserted in the operating zone of the core (fine control or operating rods). At the nominal rating conditions or close to them, the operating zone is limited to some steps of insertion in the order of a few tens of cm. In fact, only the lower part of the control rods are subjected to a significant neutron flux with an impact on the neutron activation and so on the waste classification (Low Level Short-lived Waste versus Intermediate Level Long-lived Waste). Our calculative as well as experimental experience confirms the significant presence of radionuclides in the control rods, but only in the lower parts. Measuring, cutting and finally sorting control rod scraps can reduce the volume of Intermediate Level Long-lived Waste planned for our storage deposit facility. This paper presents the EDF/DP2D methodologies followed to determine the sort criteria between the Low Level Short-lived Waste versus the Intermediate Level Long-lived Waste zones for the Silver-Indium-Cadmium control rods. The irradiated control rods are stored in cases without their head. Each case can contain several control rods, and the cases are stored under water in the fuel assembly pool. To calculate the radioactive inventories, we have developed a calculation scheme which is composed of a 3-dimensional mapping of the neutron flux, a calculation of the evolution of the isotopic compositions under neutron flux and finally a comparison between calculated and measured values. The main hypotheses of the control rods calculation take into account: - 3-dimensional geometry and 3-dimensional neutron sources distribution, - the isotopic compositions including impurities, - the history of irradiation resulting mainly from the daily power production, the positions of the control rods in the loading patterns and the positions in the axial operating zone. In order to validate the calculations, measurements were made 20 meters under water in the fuel assembly pool. The experimental results show the presence of many gamma emitter radionuclides. Only Ag-108m was retained for validating the calculations. This is due to the fact that silver is considered as the 'standard' chemical element for our control rods and silver produces Ag-108m which is a long-lived gamma emitter radionuclide. The analysis of the calculated results and the measured values allow us to build a simplified physics model for the simulation of the control rods activation. Finally three sort criteria can be proposed: - Without measurement devices, the sorting is based on an empirical sort criterion. Cuttings must then be made on the 2 back-ends of the control rod pins. This option is due to the difficulty in knowing the orientation of the pins in the storage cases. The cutting lines are placed at approximately 1 m from the 2 back-ends of the pins. This approach does not allow a great optimization of the sorting, less than 50% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. - With a simple dose rate measurement device, the knowledge of the orientation of the pins in the storage cases allows us to limit cuttings to the lower part of the control rods. Depending on the 'top to tail' cases, between approximately 50% and 75% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. - With an accurate measurement device, the sorting can be based on a specific activity of Ag-108m. Over 4400 Bq/g of Ag-108m (corresponding to the Intermediate Level Long-lived Waste limit), the control rod pieces can be considered as a long-lived waste. The measurements must be made over the 2 back-ends of control rod pins to examine the cases of 'top to tail' storage. This approach allows a great optimization of the sorting. Depending on the history of irradiation, more than 75% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dual resolution cone beam breast CT: A feasibility study

Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 {mu}m and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

White LED with High Package Extraction Efficiency

The goal of this project is to develop a high efficiency phosphor converting (white) Light Emitting Diode (pcLED) 1-Watt package through an increase in package extraction efficiency. A transparent/translucent monolithic phosphor is proposed to replace the powdered phosphor to reduce the scattering caused by phosphor particles. Additionally, a multi-layer thin film selectively reflecting filter is proposed between blue LED die and phosphor layer to recover inward yellow emission. At the end of the project we expect to recycle approximately 50% of the unrecovered backward light in current package construction, and develop a pcLED device with 80 lm/W{sub e} using our technology improvements and commercially available chip/package source. The success of the project will benefit luminous efficacy of white LEDs by increasing package extraction efficiency. In most phosphor-converting white LEDs, the white color is obtained by combining a blue LED die (or chip) with a powdered phosphor layer. The phosphor partially absorbs the blue light from the LED die and converts it into a broad green-yellow emission. The mixture of the transmitted blue light and green-yellow light emerging gives white light. There are two major drawbacks for current pcLEDs in terms of package extraction efficiency. The first is light scattering caused by phosphor particles. When the blue photons from the chip strike the phosphor particles, some blue light will be scattered by phosphor particles. Converted yellow emission photons are also scattered. A portion of scattered light is in the backward direction toward the die. The amount of this backward light varies and depends in part on the particle size of phosphors. The other drawback is that yellow emission from phosphor powders is isotropic. Although some backward light can be recovered by the reflector in current LED packages, there is still a portion of backward light that will be absorbed inside the package and further converted to heat. Heat generated in the package may cause a deterioration of encapsulant materials, affecting the performance of both the LED die and phosphor, leading to a decrease in the luminous efficacy over lifetime. Recent studies from research groups at Rensselaer Polytechnic Institute found that, under the condition to obtain a white light, about 40% of the light is transmitted outward of the phosphor layer and 60% of the light is reflected inward.1,2 It is claimed that using scattered photon extraction (SPE) technique, luminous efficacy is increased by 60%. In this project, a transparent/translucent monolithic phosphor was used to replace the powdered phosphor layer. In the normal pcLED package, the powdered phosphor is mixed with silicone either to be deposited on the top of LED die forming a chip level conversion (CLC) white LED or to be casted in the package forming a volume conversion white LED. In the monolithic phosphors there are no phosphor powder/silicone interfaces so it can reduce the light scattering caused by phosphor particles. Additionally, a multi-layer thin film selectively reflecting filter is inserted in the white LED package between the blue LED die and phosphor layer. It will selectively transmit the blue light from the LED die and reflect the phosphor's yellow inward emission outward. The two technologies try to recover backward light to the outward direction in the pcLED package thereby improving the package extraction efficiency.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress in the development of the neutron flux monitoring system of the French GEN-IV SFR: simulations and experimental validations [ANIMMA--2015-IO-392]

France has a long experience of about 50 years in designing, building and operating sodium-cooled fast reactors (SFR) such as RAPSODIE, PHENIX and SUPER PHENIX. Fast reactors feature the double capability of reducing nuclear waste and saving nuclear energy resources by burning actinides. Since this reactor type is one of those selected by the Generation IV International Forum, the French government asked, in the year 2006, CEA, namely the French Alternative Energies and Atomic Energy Commission, to lead the development of an innovative GEN-IV nuclear- fission power demonstrator. The major objective is to improve the safety and availability of an SFR. The neutron flux monitoring (NFM) system of any reactor must, in any situation, permit both reactivity control and power level monitoring from startup to full power. It also has to monitor possible changes in neutron flux distribution within the core region in order to prevent any local melting accident. The neutron detectors will have to be installed inside the reactor vessel because locations outside the vessel will suffer from severe disadvantages; radially the neutron shield that is also contained in the reactor vessel will cause unacceptable losses in neutron flux; below the core the presence of a core-catcher prevents from inserting neutron guides; and above the core the distance is too large to obtain decent neutron signals outside the vessel. Another important point is to limit the number of detectors placed in the vessel in order to alleviate their installation into the vessel. In this paper, we show that the architecture of the NFM system will rely on high-temperature fission chambers (HTFC) featuring wide-range flux monitoring capability. The definition of such a system is presented and the justifications of technological options are brought with the use of simulation and experimental results. Firstly, neutron-transport calculations allow us to propose two in-vessel regions, namely the above-core and under-core structures. We verify that they comply with the main objective, that is the neutron power and flux distribution monitoring. HTFC placed in these two regions can detect an inadvertent control rod withdrawal that is a postulated initiating event for safety demonstration. Secondly, we show that the HTFC reliability is enhanced thanks to a more robust physical design and the fact that it has been justified that the mineral insulation is insensitive to any increase in temperature. Indeed, the HTFC insulation is subject to partial discharges at high temperature when the electric field between their electrodes is greater than about 200 V/mm or so. These discharges give rise to signals similar to the neutron pulses generated by a fission chamber itself, which may bias the HTFC count rate at start-up only. However, as displayed in Figure 1, we have experimentally verified that one can discriminate neutron pulses from partial discharges using online estimation of pulse width. Thirdly, we propose to estimate the count rate of a HTFC using the third order cumulant of its signal that is described by a filtered Poisson process. For such a statistic process, it is known that any cumulant, also called cumulative moment, is proportional to the process intensity that is here the count rate of a fission chamber. One recalls that the so-called Campbelling mode of such a detector is actually based on the signal variance, which is the second-order cumulant as well. The use of this extended Campbelling mode based on the third-order cumulant will permit to ensure the HTFC response linearity over the entire neutron flux range using a signal processing technique that is simple enough to satisfy design constraints on electric devices important for nuclear safety. We also show that this technique, named high order Campbelling method (HOC), is significantly more robust than another technique based on the change in the HTFC filling gas, which consists in adding a few percent of nitrogen. Finally, we also present an experimental campaign devoted to the required calibration process of the so-called HOC method. The Campbelling results show a good agreement with the simple pulse counting estimation at low count rates. It is also shown that the HOC technique provides a linear estimation of the count rates at higher power levels as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recent research and development for the dual coolant blanket concept in the US

The dual-coolant lead-lithium, or DCLL, blanket concept is of strong interest in the US fusion technology program. In the DCLL blanket, the flow channel insert (FCI) is a critical component. FCIs must have low electrical and thermal conductivity and be compatible with lead-lithium eutectic alloy (Pb-17Li) at elevated temperatures. FCIs must retain structural integrity and desirable properties even under irradiation and large temperature gradients during operation. FCIs must not fail in such a way that Pb-17Li enters the FCI and changes its electrical or thermal conductivity significantly. Another important issue for the DCLL is the development of a suitable tritium extraction from the Pb-17Li to achieve low tritium partial pressure, thus facilitating decisive tritium control. In this paper, the state of DCLL development in the US is presented including recent design modifications and results from recent R&D efforts. Such R&D includes the progress on development and property quantification of SiC/SiC composites and SiC foams as candidate FCI materials; Pb-17Li material capability and infiltration studies; simulations of MHD Pb-17Li flow characteristics and of resultant temperature distributions; and the analysis of FCI stress states based on these thermal loads. In addition, tritium extraction from Pb-17Li based on a vacuum permeator concept is shown to have the potential to achieve the desired tritium control. A discussion of DCLL optimization and unresolved DCLL issues and future R&D needs is also presented.

36 MATERIALS SCIENCE↗