Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Statistical evaluation of control inputs and eye movements in the use of instruments clusters during aircraft landing

Two different types of analyses were done on data from a study in which eye movements and other variables were recorded while four pilots executed landing sequences in a Boeing 737 simulation. Various conditions were manupulated, including changes in turbulence, starting position, and instrumentation. Control inputs were analyzed in the context of the various conditions and compared against ratings of workload obtained using the Cooper-Harper scale. A number of eye-scanning measures including mean dwell time and transition from one instrument to another were entered into a principal components factor analysis. The results show a differentiation between control inputs and eye-scanning behavior. This shows the need for improved definition of workload and experiments to uncover the important differences among control inputs, eye-scanning and cognitive processes of the pilot.

Dick, A. O.↗

The effect of variations in controls and displays on helicopter instrument approach capability

A flight investigation was conducted with a variable stability helicopter to determine the effects of variations in controls and displays on helicopter instrument approach capabilities. The baseline instrument approach task was a decelerating approach to a hover along a 6 deg glide slope. Pilot evaluations were obtained for both the constant speed part of the task and the deceleration and hover part of the task. The attitude stability augmentation system (SAS) was strongly preferred over the rate SAS because the aircraft had a divergent pitch response. From a display variation standpoint, it was not possible to decelerate to a hover in a consistent manner, regardless of the control system employed, with situation information only. In particular, the deceleration and hover part of the task was unacceptable without flight director command information.

Niessen, F. R.↗

Analytical procedure for evaluating speckle-effect instrumentation

A general analysis suitable for developing speckle effect instruments and a simplified analysis suitable for evaluating laser speckle instrumentation are presented. The simplified analysis is summarized as a list of equations. Several sample applications are discussed.

Decker, A. J.↗

Research instrumentation for tornado electromagnetics emissions detection

Instrumentation for receiving, processing, and recording HF/VHF electromagnetic emissions from severe weather activity is described. Both airborne and ground-based instrumentation units are described on system and subsystem levels. Design considerations, design decisions, and the rationale behind the decisions are given. Performance characteristics are summarized and recommendations for improvements are given. The objectives, procedures, and test results of the following are presented: (1) airborne flight test in the Midwest U.S.A. (Spring 1975) and at the Kennedy Space Center, Florida (Summer 1975); (2) ground-based data collected in North Georgia (Summer/Fall 1975); and (3) airborne flight test in the Midwest (late Spring 1976) and at the Kennedy Space Center, Florida (Summer 1976). The Midwest tests concentrated on severe weather with tornadic activity; the Florida and Georgia tests monitored air mass convective thunderstorm characteristics. Supporting ground truth data from weather radars and sferics DF nets are described.

Jenkins, H. H.↗

Electric vehicle power train instrumentation: Some constraints and considerations

The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high harmonic components contained in the current waveforms require frequency response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement requires not only adequate frequency response but must also address phase errors caused by the finite bandwidths and component characteristics involved. The implications of these problems are assessed.

Triner, J. E.↗

Instrumentation and data acquisition systems

A comprehensive and integrated measurement system was identified and a design and development effort initiated to meet the criteria imposed by the National Transonic Facility operating environment. Specific measurement areas receiving concentrated attention include: data acquisition, force measurement, pressure instrumentation, flow visualization techniques, model attitude and model deformation measurement, and temperature measurement. The NTF instrument complex will be centered around four 32-bit, 1-microsecond-cycle-time central processing units connected in a multipoint-distributed network configuration. The principal activities to be supported by these computers are: (1) data base management and processing; (2) research measurement data acquisition and display; (3) tunnel and model control; and (4) process monitoring and communication control. The distributed network approach was chosen to modularize the functional software into definable and implementable parts by the various groups involved in the design and to permit use of similar hardware configurations to improve reliability and maintainability.

Guarino, J. F.↗

Evaluation of two gas-dilution methods for instrument calibration

Two gas dilution methods were evaluated for use in the calibration of analytical instruments used in air pollution studies. A dual isotope fluorescence carbon monoxide analyzer was used as the transfer standard. The methods are not new but some modifications are described. The rotary injection gas dilution method was found to be more accurate than the closed loop method. Results by the two methods differed by 5 percent. This could not be accounted for by the random errors in the measurements. The methods avoid the problems associated with pressurized cylinders. Both methods have merit and have found a place in instrument calibration work.

Evans, A., Jr.↗

The HEAO-A Scanning Modulation Collimator instrument

The Scanning Modulation Collimator X-ray instrument for the HEAO-A satellite was designed to measure celestial radiation in the range between 1 and 15 KeV and to resolve, and correlate, the position of X-ray sources with visible light sources on the celestial sphere to within 5 arc seconds. The positional accuracy is made possible by mechanical collimation of the X-ray sources viewed by the instrument. High sensitivity is provided from two systems each containing four gas filled proportional counters followed by preamplification, signal summing, pulse height analysis, pulse shape discrimination, X-ray event accumulators and telemetry processing electronics.

Roy, A.↗

Instrumentation for space flight experiments

The selection of measurement systems for experiments conducted in the context of a space flight must be guided by the criteria applicable to any scientific study requiring objective measurements of physiological variables. Steps fundamental to the process of choosing the best instrumentation system are identified and the key factors in matching the operational characteristics of the instrumentation to its intended use are discussed. Special problems in obtaining data from nonhuman primates, whether restrained or unrestrained, are explored. Choices for data processing are evaluated as well as the use of prototype flight tests and simulations to assess future life science experiments for spacelab or payloads for the space shuttle biomedical scientific satellite.

Mccutcheon, E. P.↗

Global sensing of gaseous and aerosol trace species using automated instrumentation on 747 airliners

The Global Atmospheric Sampling Program (GASP) by NASA is collecting and analyzing data on gaseous and aerosol trace species in the upper troposphere and lower stratosphere. Measurements are obtained from automated systems installed on four 747 airliners flying global air routes. Advances were made in airborne sampling instrumentation. Improved instruments and analysis techniques are providing an expanding data base for trace species including ozone, carbon monoxide, water vapor, condensation nuclei and mass concentrations of sulfates and nitrates. Simultaneous measurements of several trace species obtained frequently can be used to uniquely identify the source of the air mass as being typically tropospheric or stratospheric. A quantitative understanding of the tropospheric-stratospheric exchange processes leads to better knowledge of the atmospheric impact of pollution through the development of improved simulation models of the atmosphere.

Perkins, P. J.↗

Instrument technology for remote-surface exploration, prospecting and assaying, part 2

The capability to specify new instrument/mechanism technology needs, for effective remote surface exploration, prospecting and assaying (EPA), requires first, an understanding of the functions or major elements of such a task, and second an understanding of the scientific instruments and support mechanisms that may be involved. An analog or task model was developed from which the various functions, operational procedures, scientific instruments, and support mechanisms for an automated mission could be derived. The task model led to the definition of nine major functions or categories of discrete operational elements that may have to be accomplished on a mission of this type. Each major function may stand alone as an element of an EPA mission, but more probably a major function will require the support of other functions, so they are inter-related.

Brereton, R. G.↗

Instruments for measuring the amount of moisture in the air

A summarization and discussion of the many systems available for measuring moisture in the atmosphere is presented. Conventional methods used in the field of meteorology and methods used in the laboratory are discussed. Performance accuracies, and response of the instruments were reviewed as well as the advantages and disadvantages of each. Methods of measuring humidity aloft by instrumentation onboard aircraft and balloons are given, in addition to the methods used to measure moisture at the Earth's surface.

Johnson, D. L.↗

Electric vehicle power train instrumentation - Some constraints and considerations

The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high-harmonic components contained in the current waveforms require frequency-response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement not only requires adequate frequency response but also must address phase errors caused by the finite bandwidths and component characteristics involved. This paper discusses the implications of these problems and reports on the degree to which they have been solved at Lewis Research Center.

Triner, J. E.↗

Infrared instrumentation on NASA airborne observatories

Two airborne observatories operated above much of the earth's atmosphere are providing effective platforms for infrared astronomical observations. A summary is given of the wide variety of instrumentation currently in use and continuing to be developed for these facilities. The classes of instruments include various far infrared photometers, filter wheel and grating spectrometers, Fourier transform spectrometers, Michelson and Fabry-Perot interferometers, a polarimeter, and a microwave line receiver.

Boggess, N. W.↗

The high-energy celestial X-ray instrument on board OSO-8

The 20 keV-3 MeV celestial X-ray detector on the OSO-8 is described. The primary objectives of this instrument are to measure the energy spectrum of cosmic X-ray sources above 20 keV and to search for time variations, both periodic and irregular, in the intensity of the sources detected. The detector consists of two optically isolated central crystals shielded by a large, active collimator. The sensitive area is 27.5 sq cm and the field-of-view is 5 deg FWHM. The instrument is mounted in the wheel section of OSO-8 with the axis of its field of view offset by 5 deg from the negative spin axis of the wheel. The minimum detectable intensity of a point source which is brought to within 5 deg of the negative spin axis for greater than one day is about 10 to the minus fifth power photons/sq cm-sec at 100 keV.

Dennis, B. R.↗

The HEAO-B Monitor Proportional Counter Instrument

The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.

Gaillardetz, R.↗

Temperature control analysis and flight results for the Viking Orbiter 1975 Mars atmospheric water detection instrument

The Mars atmospheric water detector (MAWD) instrument required a temperature of -70 C at the detector. The monochromator housing required +20 C + or - 1 C. This instrument was located on the scan platform, and slewed across two solar panels. The thermal design for the detector was an open flat plate radiator thermally isolated on four 1-in. tubes, with a flexible strap to the detector. MAWD radiator view factors and heat loads from the spacecraft were determined for the Lander on and off, for all angular positions of the scan platform. Subsystem and system tests were performed using the 25-ft diameter solar simulator. In-flight results have shown no anomalies, and no degradation has been observed. Servo-controlled heaters are used to control the temperature.

Kavanagh, H. M.↗

Instrumental variables algorithm for modal parameter identification in flutter testing

The paper is concerned with the task of estimating modal parameters from system response measurement in aircraft flutter testing. A frequency-domain derivation of an instrumental-variables algorithm is presented for a linear time-invariant dynamic system of order n. Basically, this algorithm fits a set of poles and zeros to the measured transfer function. An illustrative example is provided regarding the application of the algorithm to aeroelasticity testing. It is shown that the algorithm can be implemented for on-line data reduction with a microcomputer-based analysis system. By using instrumental variables the sensitivity of the modal parameter estimates to noise in the system-response measurements is reduced greatly. The algorithm is expected to be a powerful and valuable tool for on-line estimation of modal parameters in flutter testing and should be useful in control system and structural dynamics tests.

Johnson, W.↗