Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Solar Infrared Radiation Station (SIRS), Sky Radiation (SKYRAD), Ground Radiation (GNDRAD), and Broadband Radiometer Station (BRS) Instrument Handbook

The solar infrared radiation station (SIRS), ground radiometers on stand for upwelling radiation (GNDRAD), and sky radiometers on stand for downwelling radiation (SKYRAD) provide continuous measurements of broadband shortwave (solar) and longwave (atmospheric or infrared) irradiances for downwelling and upwelling components. The following six irradiance measurements are collected from a network of stations to help determine the total radiative flux exchange at each of the primary U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) field research sites—(Southern Great Plains [SGP], North Slope of Alaska [NSA)]and Eastern North Atlantic [ENA])—as well as the ARM mobile facilities (AMF): Direct normal shortwave (solar beam), Diffuse horizontal shortwave (sky), Global horizontal shortwave (total hemispheric), Upwelling shortwave (reflected), Downwelling longwave (atmospheric infrared), Upwelling longwave (surface infrared).

54 ENVIRONMENTAL SCIENCES↗

Micro Reactor Instrumentation and Control FY2019 Report

Micro-reactors (i.e., very small transportable or mobile nuclear reactors with a capacity less than 20 MWt) are being developed to supply heat and power for various applications in remote areas, military installations, emergency operations, humanitarian missions, and disaster relief zones. A wide variety of reactor types are under consideration, including sodium-cooled fast reactors, molten salt reactors, light water reactors, very-high-temperature gas reactors, and heat pipe reactors. These miniaturized transportable reactor designs remain largely untested and unproven. System and component testing are needed to demonstrate design safety and system robustness, reliability and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Precision Gas System Isotope Analyzer (PGSISO) Instrument Handbook

The PGSISO is a combination of several systems in series; (1) gas processing components that pressurize and prevent liquid water entering the sample stream, and (2) the Spectronus FTIR spectrometer, which measures continuous CO 2 , 12 CO 2 , 13 CO 2 , CH 4 , CO, N 2 O, and H 2 O. The Spectronus analyzer has been developed by the Centre for Atmospheric Chemistry at the University of Wollongong, Australia, and manufactured by Ecotech Pty Ltd, headquartered in Melbourne, Australia.

54 ENVIRONMENTAL SCIENCES↗

Collider Physics Instrumentation

We are developing new technologies for particle tracking. These include 3D silicon sensors and devices for calibration and dosimetry in the HL-LHC fluence regime. We collaborate in the development of a new model for radiation damage in silicon - this is immediately relevant to extrapolations about the future of LHC tracker hardware. We lead radiation damage campaigns on behalf of many collaborating LHC institutes as well as ourselves, and we apply the results of these to development of new techniques for particle beam monitoring and operation of silicon detectors in variable environmental conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Scattering Instrumentation Research and Development for High Spatial and Temporal Resolution Imaging at Oak Ridge National Laboratory

Neutron scattering facilities like those available at ORNL are enabling the discovery and development of advanced materials include those to be used for next generation energy storage systems. In spite of all the success that neutron imaging has enjoyed in recent years, even higher-impact research is limited by the current temporal and spatial resolution of neutron detection devices. In particular, the spatial resolution of all neutron imaging methods in use and under development is fundamentally limited by the variance introduced by the charged particles emitted from neutron absorption. Thus, we are investigating, designing and demonstrating an array of ~1 micron-sized glass scintillating fibers arranged via photonics-crystal-fiber patterning techniques-- with particle tracking (a must) so that position resolution can be finer than than that allowed by the charged particle ranges. The processes, knowledge and algorithms developed will allow for spatially (1 micron) and time resolved (<100 ns), high throughput neutron transmission imaging in large areas at reasonable costs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Literature Review of Thermomechanical Analysis, Its Instrument Components and Applications

Thermomechanical analysis (TMA) is used to measure the dimensional changes in a sample as a function of temperature. TMA allows for several modes of analysis, with expansion and compression being the most common. TMA is based on the theory of dilatometry and relies on the fact that polymers are viscoelastic materials, possessing both viscous and elastic properties. TMA yields information about the thermal effects on a polymer such as shrinkage, expansion, softening, melting, glass transition temperature and allows for the calculation of the coefficient of thermal expansion (CTE), which can be useful for many applications of polymers.

36 MATERIALS SCIENCE↗

Literature Review of Thermomechanical Analysis, Its Instrument Components and Applications

Thermomechanical analysis (TMA) is used to measure the dimensional changes in a sample as a function of temperature. TMA allows for several modes of analysis, with expansion and compression being the most common. TMA is based on the theory of dilatometry and relies on the fact that polymers are viscoelastic materials, possessing both viscous and elastic properties. TMA yields information about the thermal effects on a polymer such as shrinkage, expansion, softening, melting, glass transition temperature and allows for the calculation of the coefficient of thermal expansion (CTE), which can be useful for many applications of polymers.

36 MATERIALS SCIENCE↗

Time-Resolved Aerosol Filter Sampler Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook describes the principles and operations of the filter sampler.

54 ENVIRONMENTAL SCIENCES↗

Advanced Mixing Condensation Particle Counter (aMCPC) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (aMCPC, 9403), a miniaturized optical practical counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook focuses on the aMCPC, which measures the ultra-fast total aerosol particle number concentration at 180 ms response rate with a detection diameter (D 50 = 7 nm).

54 ENVIRONMENTAL SCIENCES↗

Aircraft-Integrated Meteorological Measurement System (AIMMS) Instrument Handbook

The AIMMS-20 probe is manufactured by Aventech Research Inc. and measures platform position, velocity, attitude, ambient temperature, static pressure, and the differential pressures from a 5-port hemispheric gust probe, and combines all these measured data into a calculation of the ambient winds. A detailed description of the AIMMS-20 specifications is available here. Note: The Aventech engineers use the aircraft-centric frame of reference common to aeronautical engineering, which defines z as down.

54 ENVIRONMENTAL SCIENCES↗

Miniaturized Optical Particle Counter (MOPC) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (mOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook focuses on the mOPC, which measures the aerosol particle size distribution between 0.19 and 3 μm.

54 ENVIRONMENTAL SCIENCES↗

First ARM Mobile Facility (AMF1) Aerosol Observing System (AOS01) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Mobile Aerosol Observing System – Aerosols (MAOS-A), designated AOS01, entered service in March of 2012 at the Los Alamos National Laboratory for the Pajarito Aerosol Coupling to Ecosystems (PACE) field campaign. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floor are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗