Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Experimental Study of RF Pulsed Heating

Cyclic thermal stresses produced by rf pulsed heating can be the limiting factor on the attainable reliable gradients for room temperature linear accelerators. This is especially true for structures that have complicated features for wakefield damping. These limits could be pushed higher by using special types of copper, copper alloys, or other conducting metals in constructing partial or complete accelerator structures. Here we present an experimental study aimed at determining the potential of these materials for tolerating cyclic thermal fatigue due to rf magnetic fields. A special cavity that has no electric field on the surface was employed in these studies. The cavity shape concentrates the magnetic field on one flat surface where the test material is placed. The materials tested in this study have included oxygen free electronic grade copper, copper zirconium, copper chromium, hot isostatically pressed copper, single crystal copper, electroplated copper, Glidcop(reg. sign), copper silver, and silver plated copper. The samples were exposed to different machining and heat treatment processes prior to rf processing. Each sample was tested to a peak pulsed heating temperature of approximately 110 C and remained at this temperature for approximately 10 x 10 6 rf pulses. In general, the results showed the possibility of pushing the gradient limits due to pulsed heating fatigue by the use of copper zirconium and copper chromium alloys.

36 MATERIALS SCIENCE↗

Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: Dose and IAEA-compliant phase space calculations

Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian TrueBeam treatment head geometry imported from cad (computer aided design) without adjusting the input electron phase space parameters. Methods: geant4 v4.9.2.p01 was employed to simulate the 6 MV beam treatment head geometry of the Varian TrueBeam linac. The electron tracks in the linear accelerator were simulated with Parmela, and the obtained electron phase space was used as an input to the Monte Carlo beam transport and dose calculations. The geometry components are tessellated solids included in geant4 as gdml (generalized dynamic markup language) files obtained via STEP (standard for the exchange of product) export from Pro/Engineering, followed by STEP import in Fastrad, a STEP-gdml converter. The linac has a compact treatment head and the small space between the shielding collimator and the divergent arc of the upper jaws forbids the implementation of a plane for storing the phase space. Instead, an IAEA (International Atomic Energy Agency) compliant phase space writer was implemented on a cylindrical surface. The simulation was run in parallel on a 1200 node Linux cluster. The 6 MV dose calculations were performed for field sizes varying from 4 x 4 to 40 x 40 cm{sup 2}. The voxel size for the 60x60x40 cm{sup 3} water phantom was 4x4x4 mm{sup 3}. For the 10x10 cm{sup 2} field, surface buildup calculations were performed using 4x4x2 mm{sup 3} voxels within 20 mm of the surface. Results: For the depth dose curves, 98% of the calculated data points agree within 2% with the experimental measurements for depths between 2 and 40 cm. For depths between 5 and 30 cm, agreement within 1% is obtained for 99% (4x4), 95% (10x10), 94% (20x20 and 30x30), and 89% (40x40) of the data points, respectively. In the buildup region, the agreement is within 2%, except at 1 mm depth where the deviation is 5% for the 10x10 cm{sup 2} open field. For the lateral dose profiles, within the field size for fields up to 30x30 cm{sup 2}, the agreement is within 2% for depths up to 10 cm. At 20 cm depth, the in-field maximum dose difference for the 30x30 cm{sup 2} open field is within 4%, while the smaller field sizes agree within 2%. Outside the field size, agreement within 1% of the maximum dose difference is obtained for all fields. The calculated output factors varied from 0.938{+-}0.015 for the 4x4 cm{sup 2} field to 1.088{+-}0.024 for the 40x40 cm{sup 2} field. Their agreement with the experimental output factors is within 1%. Conclusions: The authors have validated a geant4 simulated IAEA-compliant phase space of the TrueBeam linac for the 6 MV beam obtained using a high accuracy geometry implementation from cad. These files are publicly available and can be used for further research.

43 PARTICLE ACCELERATORS↗

Electron contamination modeling and skin dose in 6 MV longitudinal field MRIgRT: Impact of the MRI and MRI fringe field

Purpose: In recent times, longitudinal field MRI-linac systems have been proposed for 6 MV MRI-guided radiotherapy (MRIgRT). The magnetic field is parallel with the beam axis and so will alter the transport properties of any electron contamination particles. The purpose of this work is to provide a first investigation into the potential effects of the MR and fringe magnetic fields on the electron contamination as it is transported toward a phantom, in turn, providing an estimate of the expected patient skin dose changes in such a modality. Methods: Geant4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam were performed. Longitudinal magnetic fields of strengths between 0 and 3 T were applied to a 30 x 30 x 20 cm{sup 3} phantom. Surrounding the phantom there is a region where the magnetic field is at full MRI strength, consistent with clinical MRI systems. Beyond this the fringe magnetic field entering the collimation system is also modeled. The MRI-coil thickness, fringe field properties, and isocentric distance are varied and investigated. Beam field sizes of 5 x 5, 10 x 10, 15 x 15 and 20 x 20 cm{sup 2} were simulated. Central axis dose, 2D virtual entry skin dose films, and 70 {mu}m skin depth doses were calculated using high resolution scoring voxels. Results: In the presence of a longitudinal magnetic field, electron contamination from the linear accelerator is encouraged to travel almost directly toward the patient surface with minimal lateral spread. This results in a concentration of electron contamination within the x-ray beam outline. This concentration is particularly encouraged if the fringe field encompasses the collimation system. Skin dose increases of up to 1000% were observed for certain configurations and increases above Dmax were common. In nonmagnetically shielded cases, electron contamination generated from the jaw faces and air column is trapped and propagated almost directly to the phantom entry region, giving rise to intense dose hot spots inside the x-ray treatment field. These range up to 1000% or more of Dmax at the CAX, depending on field size, isocenter, and coil thickness. In the case of a fully magnetically shielded collimation system and the lowest MRI field of 0.25 T, the entry skin dose is expected to increase to at least 40%, 50%, 65%, and 80% of Dmax for 5 x 5, 10 x 10, 15 x 15, and 20 x 20 cm{sup 2}, respectively. Conclusions: Electron contamination from the linac head and air column may cause considerable skin dose increases or hot spots at the beam central axis on the entry side of a phantom or patient in longitudinal field 6 MV MRIgRT. This depends heavily on the properties of the magnetic fringe field entering the linac beam collimation system. The skin dose increase is also related to the MRI-coil thickness, the fringe field, and the isocenter distance of the linac. The results of this work indicate that the properties of the MRI fringe field, electron contamination production, and transport must be considered carefully during the design stage of a longitudinal MRI-linac system.

43 PARTICLE ACCELERATORS↗

Neutron production in the beryllium filter of a linac using 6 MeV treatment beam - 25425

In most conventional radiation therapy treatments, special attention is paid for neutron contamination when working with energy beams above 8 MeV. Generally, neutron generation it is only considered for shielding requirements, not for dose study in patients or employees. The present work is focused on studying the unwanted generated photoneutrons in a Medical Linear Accelerator (Linac) Varian TrueBeam using a 6 MeV radiation treatment beam. To that, Monte Carlo (MC) simulation code MCNP6.1.1 was used. This new version of the code allows the use of unstructured mesh geometries models, offering more geometric reliable results. The particularity of the studied Linac is the presence of a beryllium filter at the treatment head. Since Beryllium causes photonuclear reactions (γ, n) at energies much lower than other Linac composing materials, this work aims to analyze if this type of unit, when using low energy treatment beams (6 MeV), produce significant neutron dose and to ensure that this unwanted radiation can be considered negligible. (authors)

43 PARTICLE ACCELERATORS↗

Shielding maze design for Line C tunnel at LANSCE - 25456

The Los Alamos Neutron Science Center (LANSCE) is a major experimental facility at Los Alamos National Laboratory. The LANSCE linear accelerator (linac) supplies proton beams to five experimental areas simultaneously. The Isotope Production Facility (IPF) utilizes a 100-MeV beam after the first stage of acceleration, all other facilities use proton beams at 800 MeV. However, the facility can support sole-use experiments at 200-600 MeV proton beam energies. There are three spallation neutron sources providing neutrons in different energy regimes: Weapons Neutron Research (WNR), Lujan Neutron Scattering Center (Lujan Center) and the Ultra Cold Neutron source (UCN). The proton radiography (pRAD) facility utilizes the energetic proton beam for imaging and tomography directly. The beam to pRAD and UCN facilities is delivered via line X that splits into line C (pRAD) and line B (UCN). Due to engineering access controls it is impossible to deliver beam to UCN while the pRAD facility is occupied. The goal of our project was to design a shielding maze arrangement for line C to allow for simultaneous beam delivery to UCN while pRAD area (dome) is occupied. (authors)

43 PARTICLE ACCELERATORS↗

Study of K_S Production with the BaBar Experiment

We study the inclusive production of short-lived neutral kaons (K{sub S}) with the BABAR experiment at the Stanford Linear Accelerator Center. The study is based on a sample of 383 million B{bar B} pairs produced in e{sup +}e{sup -}collisions at the {Upsilon}(4S) resonance, in which one B meson has been fully reconstructed. We select a clean sample of K{sub S} mesons and compare kinematic spectra for data and simulation. We find that the simulation overestimates the total production rate of K{sub S} and we see differences in the shape of the K{sub S} momentum spectra. We derive correction factors for different momentum intervals to bring the simulation into better agreement with the observed data.

43 PARTICLE ACCELERATORS↗

Radiation monitoring with CVD Diamonds and PIN Diodes at BaBar

The BaBar experiment at the Stanford Linear Accelerator Center has been using two polycrystalline chemical vapor deposition (pCVD) diamonds and 12 silicon PIN diodes for radiation monitoring and protection of the Silicon Vertex Tracker (SVT). We have used the pCVD diamonds for more than 3 years, and the PIN diodes for 7 years. We will describe the SVT and SVT radiation monitoring system as well as the operational difficulties and radiation damage effects on the PIN diodes and pCVD diamonds in a high-energy physics environment.

36 MATERIALS SCIENCE↗

Measurement of the Color-Suppressed B0->D(*)0 pi0 /omega/eta/eta Prime Branching Fractions

The authors report results on the branching fraction (BF) measurement of the color-suppressed decays {bar B}{sup 0} {yields} D{sup 0}{pi}{sup 0}, D*{sup 0}{pi}{sup 0}, D{sup 0}{eta}, D*{sup 0}{eta}, D{sup 0}{omega}, D*{sup 0}{omega}, D{sup 0}{eta}{prime}, and D*{sup 0}{eta}{prime}. They measure the branching fractions BF(D{sup 0}{pi}{sup 0}) = (2.78 {+-} 0.08 {+-} 0.20) x 10{sup -4}, BF(D*{sup 0}{pi}{sup 0}) = (1.78 {+-} 0.13 {+-} 0.23) x 10{sup -4}, BF(D{sup 0}{eta}) = (2.41 {+-} 0.09 {+-} 0.17) x 10{sup -4}, BF(D*{sup 0}{eta}) = (2.32 {+-} 0.13 {+-} 0.22) x 10{sup -4}, BF(D{sup 0}{omega}) = (2.77 {+-} 0.13 {+-} 0.22) x 10{sup -4}, BF(D*{sup 0}{omega}) = (4.44 {+-} 0.23 {+-} 0.61) x 10{sup -4}, BF(D{sup 0}{eta}{prime}) = (1.38 {+-} 0.12 {+-} 0.22) x 10{sup -4} and BF(D*{sup 0}{eta}{prime}) = (1.29 {+-} 0.23 {+-} 0.23) x 10{sup -4}, where the first uncertainty is statistical and the second is systematic. The result is based on a sample of (454 {+-} 5) x 10{sup 6} B{bar B} pairs collected at the {Upsilon}(4S) resonance from 1999 to 2007, with the BABAR detector at the PEP-II storage rings at the Stanford Linear Accelerator Center. The measurements are compared to theoretical predictions by factorization, SCET and pQCD. The presence of final state interactions predictions by factorization, SCET and pQCD. The presence of final state interactions is confirmed and the measurements seem to be more in favor of SCET compared to pQCD.

43 PARTICLE ACCELERATORS↗

Fermilab Steering Group Report

The Fermilab Steering Group has developed a plan to keep U.S. accelerator-based particle physics on the pathway to discovery, both at the Terascale with the LHC and the ILC and in the domain of neutrinos and precision physics with a high-intensity accelerator. The plan puts discovering Terascale physics with the LHC and the ILC as Fermilab's highest priority. While supporting ILC development, the plan creates opportunities for exciting science at the intensity frontier. If the ILC remains near the Global Design Effort's technically driven timeline, Fermilab would continue neutrino science with the NOvA experiment, using the NuMI (Neutrinos at the Main Injector) proton plan, scheduled to begin operating in 2011. If ILC construction must wait somewhat longer, Fermilab's plan proposes SNuMI, an upgrade of NuMI to create a more powerful neutrino beam. If the ILC start is postponed significantly, a central feature of the proposed Fermilab plan calls for building an intense proton facility, Project X, consisting of a linear accelerator with the currently planned characteristics of the ILC combined with Fermilab's existing Recycler Ring and the Main Injector accelerator. The major component of Project X is the linac. Cryomodules, radio-frequency distribution, cryogenics and instrumentation for the linac are the same as or similar to those used in the ILC at a scale of about one percent of a full ILC linac. Project X's intense proton beams would open a path to discovery in neutrino science and in precision physics with charged leptons and quarks. World-leading experiments would allow physicists to address key questions of the Quantum Universe: How did the universe come to be? Are there undiscovered principles of nature: new symmetries, new physical laws? Do all the particles and forces become one? What happened to the antimatter? Building Project X's ILC-like linac would offer substantial support for ILC development by accelerating the industrialization of ILC components in the U.S. and creating an engineering opportunity for ILC cost reductions. It o.ers an early and tangible application for ILC R&D in superconducting technology, attracting participation from accelerator scientists worldwide and driving forward the technology for still higher-energy accelerators of the future, such as a muon collider. To prepare for a future decision, the Fermilab Steering Group recommends that the laboratory seek R&D support for Project X, in order to produce an overall design of Project X and to spur the R&D and industrialization of ILC linac components needed for Project X. Advice from the High Energy Physics Advisory Panel will guide any future decision to upgrade the Fermilab accelerator complex, taking into account developments a.ecting the ILC schedule and the continuing evaluation of scientific priorities for U.S. particle physics. Fermilab should also work toward increased resources for longer-term future accelerators such as a muon collider, aiming at higher energies than the ILC would provide.

43 PARTICLE ACCELERATORS↗

Preliminary Conceptual Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

Plasma wakefield acceleration has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider is the focus of FACET, a National User Facility at SLAC. The existing FACET National User Facility uses part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and positrons. FACET-II is a new test facility to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. It is the only facility in the world with high energy positron beams. FACET-II provides a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique. It will synergistically pursue accelerator science that is vital to the future of both advanced acceleration techniques for High Energy Physics, ultra-high brightness beams for Basic Energy Science, and novel radiation sources for a wide variety of applications. The design parameters for FACET-II are set by the requirements of the plasma wakefield experimental program. To drive the plasma wakefield requires a high peak current, in excess of 10kA. To reach this peak current, the electron and positron design bunch size is 10μ by 10μ transversely with a bunch length of 10μ. This is more than 200 times better than what has been achieved at the existing FACET. The beam energy is 10 GeV, set by the Linac length available and the repetition rate is up to 30 Hz. The FACET-II project is scheduled to be constructed in three major stages. Components of the project discussed in detail include the following: electron injector, bunch compressors and linac, the positron system, the Sector 20 sailboat and W chicanes, and experimental area and infrastructure.

43 PARTICLE ACCELERATORS↗

Development of an RF Conditioning System for Charged-Particle Accelerators

Charged-particle accelerators use various vacuum windows on their accelerating radio-frequency (RF) cavities to throughput very high RF power. Before being placed on the cavities, the windows should be cleaned, baked, and fully RF conditioned to prevent a poor vacuum from outgassing, as well as other forms of contamination. An example is the coaxial fundamental power coupler (FPC) with an annular alumina ceramic window for each of the 81 superconducting RF cavities in the Spallation Neutron Source (SNS) linear accelerator. The FPCs needed to be tested up to 650-kW peak in a traveling wave and 2.6 MW with standing wave peaks in 1.3 and 60 pulses/s at 805 MHz. In this paper, an Experimental-Physics-and-Industrial-Control-System-based RF conditioning system for the SNS RF test facility is presented. This paper summarizes the hardware and software design strategies, provides the results obtained, and describes the future research scope.

43 PARTICLE ACCELERATORS↗

Measurement of Branching Fractions of B0 Decays to K1(1270)+ pi- and K1(1400)+ pi-

We present a measurement of the branching fraction of neutral B meson decaying to final states containing a K1 meson, i.e. K{sub 1}(1270) and K{sub 1}(1400), and a charged pion. The data, collected with the BABAR detector at the Stanford Linear Accelerator Center, represent 454 million B{bar B} pairs produced in e{sup +}e{sup -} annihilation. We measure the branching fraction {Beta}(B{sup 0} {yields} K{sub 1}{sup +}{pi}{sup -}) = (31.0 {+-} 2.7 {+-} 6.9) x 10{sup -6}, where the first error quoted is statistical and the second is systematic. In the framework of the K-matrix formalism used to describe these decays, we also set limits on the ratio of the production constants for the K{sub 1}(1270){sup +} and K{sub 1}(1400){sup +} mesons in B{sup 0} decays.

43 PARTICLE ACCELERATORS↗

Doppler Broadening Analysis of Steel Specimens Using Accelerator Based In Situ Pair Production

Positron Annihilation Spectroscopy (PAS) techniques can be utilized as a sensitive probe of defects in materials. Studying these microscopic defects is very important for a number of industries in order to predict material failure or structural integrity. We have been developing gamma-induced pair-production techniques to produce positrons in thick samples ({approx}4-40 g/cm{sup 2}, or {approx}0.5-5 cm in steel). These techniques are called 'Accelerator-based Gamma-induced Positron Annihilation Spectroscopy'(AG-PAS). We have begun testing the capabilities of this technique for imaging of defect densities in thick structural materials. As a first step, a linear accelerator (LINAC) was employed to produce photon beams by stopping 15 MeV electrons in a 1 mm thick tungsten converter. The accelerator is capable of operating with 30-60 ns pulse width, up to 200 mA peak current at 1 kHz repetition rate. The highly collimated bremsstrahlung beam impinged upon our steel tensile specimens, after traveling through a 1.2 m thick concrete wall. Annihilation radiation was detected by a well-shielded and collimated high-purity germanium detector (HPGe). Conventional Doppler broadening spectrometry (DBS) was performed to determine S, W and T parameters for our samples.

36 MATERIALS SCIENCE↗

LINACS FOR FUTURE MUON FACILITIES

Future Muon Colliders (MC) and Neutrino Factories (NF) based on muon storage rings will require innovative linacs to: produce the muons, cool them, compress longi-tudinally and ‘shape’ them into a beam and finally to rap-idly accelerate them to multi-GeV (NF) and TeV (MC) energies. Each of these four linac applications has new requirements and opportunities that follow from the na-ture of the muon in that it has a short lifetime (τ = 2.2 μsec) in its own rest frame, it is produced in a tertiary process into a large emittance, and its electron, photon, and neutrino decay products can be more than an annoy-ance. As an example, for optimum performance, the linac repetition rates should scale inversely with the laboratory lifetime of the muon in its storage ring, something as high as 1 kHz for a 40 GeV Neutrino Factory or as low as 20 Hz for a 5 TeV Muon Collider. A superconducting 8 GeV Linac capable of CW operation is being studied as a ver-satile option for muon production [1] for colliders, facto-ries, and muon beams for diverse purposes. A linac filled with high pressure hydrogen gas and imbedded in strong magnetic fields has been proposed to rapidly cool muon beams [2]. Recirculating Linear Accelerators (RLA) are possible because muons do not generate significant syn-chrotron radiation even at extremely high energy and in strong magnetic fields. We will describe the present status of linacs for muon applications; in particular the longitu-dinal bunch compression in a single pass linac and multi-pass acceleration in the RLA, especially the optics and technical requirements for RLA designs, using supercon-ducting RF cavities capable of simultaneous acceleration of both μ+ and μ- species, with pulsed linac quadrupoles to allow the maximum number of passes. The design will include the optics for the multi-pass linac and droplet-shaped return arcs.

43 PARTICLE ACCELERATORS↗

Measurements of charge state breeding efficiency at BNL test EBIS

Charge breeding of singly charged ions is required to efficiently accelerate rare isotope ion beams for nuclear and astrophysics experiments, and to enhance the accuracy of low-energy Penning trap-assisted spectroscopy. An efficient charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) to the ANL Tandem Linear Accelerator System (ATLAS) facility is being developed using the BNL Test Electron Beam Ion Source (Test EBIS) as a prototype. Parameters of the CARIBU EBIS charge breeder are similar to those of the BNL Test EBIS except the electron beam current will be adjustable in the range from 1 to 2 {angstrom}. The electron beam current density in the CARIBU EBIS trap will be significantly higher than in existing operational charge state breeders based on the EBIS concept. The charge state breeding efficiency is expected to be about 25% for the isotope ions extracted from the CARIBU. For the success of our EBIS project, it is essential to demonstrate high breeding efficiency at the BNL Test EBIS tuned to the regime close to the parameters of the CARIBU EBIS at ANL. The breeding efficiency optimization and measurements have been successfully carried out using a Cs{sup +} surface ionization ion source for externally pulsed injection into the BNL Test EBIS. A Cs{sup +} ion beam with a total number of ions of 5 x 10{sup 8} and optimized pulse length of 70 {mu}s has been injected into the Test EBIS and charge-bred for 5.3 ms for two different electron beam currents 1 and 1.5 {angstrom}. In these experiments we have achieved 70% injection/extraction efficiency and breeding efficiency into the most abundant charge state 17%.

43 PARTICLE ACCELERATORS↗

ISAC SC-LINAC PHASE-II HELIUM REFRIGERATOR COMMISSIONING AND FIRST OPERATIONAL EXPERIENCE AT TRIUMF

ISAC Phase-II is an upgrade of the radioactive isotope superconducting linear accelerator, SC-linac, at TRIUMF. The Phase-I section of the accelerator, medium-beta, is operational and is cooled with a 600 W helium refrigerator, commissioned in March 2005. An identical refrigerator is being used with the Phase-II segment of the accelerator; which is now under construction. The second refrigerator has been commissioned and tested with the Phase-I section of the linac and is used for Phase-II linac development, including new SC-cavity performance tests. The commissioning of the Phase-II refrigeration system and recent operational experience is presented.

43 PARTICLE ACCELERATORS↗

Ion Solid Interaction And Surface Modification At RF Breakdown In High-Gradient Linacs

Ion solid interactions have been shown to be an important new mechanism of unipolar arc formation in high-gradient rf linear accelerators through surface self-sputtering by plasma ions, in addition to an intense surface field evaporation. We believe a non-Debye plasma is formed in close vicinity to the surface and strongly affects surface atomic migration via intense bombardment by ions, strong electric field, and high surface temperature. Scanning electron microscope studies of copper surface of an rf cavity were conducted that show craters, arc pits, and both irregular and regular ripple structures with a characteristic length of 2 microns on the surface. Strong field enhancements are characteristic of the edges, corners, and crack systems at surfaces subjected to rf breakdown.

43 PARTICLE ACCELERATORS↗