Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume < 25 cc, most of the cases were underdosed by 18% with 5-mm slice thickness and 27% with 10-mm slickness. For volume > 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume < 25 cc, and 5 mm is optimum for tumor volume > 25 cc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy

To develop a quality assurance (QA) of XVI cone beam system (XVIcbs) for its optimal imaging-guided radiotherapy (IGRT) implementation, and to construe prostate tumor margin required for intensity-modulated radiation therapy (IMRT) if IGRT is unavailable. XVIcbs spatial accuracy was explored with a humanoid phantom; isodose conformity to lesion target with a rice phantom housing a soap as target; image resolution with a diagnostic phantom; and exposure validation with a Radcal ion chamber. To optimize XVIcbs, rotation flexmap on coincidency between gantry rotational axis and that of XVI cone beam scan was investigated. Theoretic correlation to image quality of XVIcbs rotational axis stability was elaborately studied. Comprehensive QA of IGRT using XVIcbs has initially been explored and then implemented on our general IMRT treatments, and on special IMRT radiotherapies such as head and neck (H and N), stereotactic radiation therapy (SRT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Fifteen examples of prostate setup accounted for 350 IGRT cone beam system were analyzed. IGRT accuracy results were in agreement {+-} 1 mm. Flexmap 0.25 mm met the manufacturer's specification. Films confirmed isodose coincidence with target (soap) via XVIcbs, otherwise not. Superficial doses were measured from 7.2-2.5 cGy for anatomic diameters 15-33 cm, respectively. Image quality was susceptible to rotational stability or patient movement. IGRT using XVIcbs on general IMRT treatments such as prostate, SRT, SRS, and SBRT for setup accuracy were verified; and subsequently coordinate shifts corrections were recorded. The 350 prostate IGRT coordinate shifts modeled to Gaussian distributions show central peaks deviated off the isocenter by 0.6 {+-} 3.0 mm, 0.5 {+-} 4.5 mm in the X(RL)- and Z(SI)-coordinates, respectively; and 2.0 {+-} 3.0 mm in the Y(AP)-coordinate as a result of belly and bladder capacity variations. Sixty-eight percent of confidence was within {+-} 4.5 mm coordinates shifting. IGRT using XVIcbs is critical to IMRT for prostate and H and N, especially SRT, SRS, and SBRT. To optimize this modality of IGRT, a vigilant QA program is indispensable. Prostate IGRT reveals treatment accuracy as subject to coordinates' adjustments; otherwise a 4.5-mm margin is required to allow for full dose coverage of the clinical target volume, notwithstanding toxicity to normal tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

Couch height–based patient setup for abdominal radiation therapy

There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on the computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rectal balloon use limits vaginal displacement, rectal dose, and rectal toxicity in patients receiving IMRT for postoperative gynecological malignancies

Pelvic radiotherapy for gynecologic malignancies traditionally used a 4-field box technique. Later trials have shown the feasibility of using intensity-modulated radiotherapy (IMRT) instead. But vaginal movement between fractions is concerning when using IMRT due to greater conformality of the isodose curves to the target and the resulting possibility of missing the target while the vagina is displaced. In this study, we showed that the use of a rectal balloon during treatment can decrease vaginal displacement, limit rectal dose, and limit acute and late toxicities. Little is known regarding the use of a rectal balloon (RB) in treating patients with IMRT in the posthysterectomy setting. We hypothesize that the use of an RB during treatment can limit rectal dose and acute and long-term toxicities, as well as decrease vaginal cuff displacement between fractions. We performed a retrospective review of patients with gynecological malignancies who received postoperative IMRT with the use of an RB from January 1, 2012 to January 1, 2015. Rectal dose constraint was examined as per Radiation Therapy Oncology Group (RTOG) 1203 and 0418. Daily cone beam computed tomography (CT) was performed, and the average (avg) displacement, avg magnitude, and avg magnitude of vector were calculated. Toxicity was reported according to RTOG acute radiation morbidity scoring criteria. Acute toxicity was defined as less than 90 days from the end of radiation treatment. Late toxicity was defined as at least 90 days after completing radiation. Twenty-eight patients with postoperative IMRT with the use of an RB were examined and 23 treatment plans were reviewed. The avg rectal V40 was 39.3% ± 9.0%. V30 was65.1% ± 10.0%. V50 was 0%. Separate cone beam computed tomography (CBCT) images (n = 663) were reviewed. The avg displacement was as follows: superior 0.4 + 2.99 mm, left 0.23 ± 4.97 mm, and anterior 0.16 ± 5.18 mm. The avg magnitude of displacement was superior/inferior 2.22 ± 2.04 mm, laterally 3.41 ± 3.62 mm, and anterior/posterior 3.86 ± 3.45 mm. The avg vector magnitude was 6.60 ± 4.14 mm. For acute gastrointestinal (GI) toxicities, 50% experienced grade 1 toxicities and 18% grade 2 GI toxicities. For acute genitourinary (GU) toxicities, 21% had grade 1 and 18% had grade 2 toxicities. For late GU toxicities, 7% had grade 1 and 4% had grade 2 toxicities. RB for gynecological patients receiving IMRT in the postoperative setting can limit V40 rectal dose and vaginal displacement. Although V30 constraints were not met, patients had limited acute and late toxicities. Further studies are needed to validate these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal performance analysis of an electrochromic vacuum glazing with low emittance coatings

Thermal performance of an electrochromic (EC) vacuum glazing (VG) was modelled under ASTM standard winter conditions. The EC VG comprised three 0.5 m by 0.5 m glass panes with a 0.12 mm wide evacuated space between two 4 mm thick panes sealed contiguously by a 6 mm wide indium based edge seal with either one or two low-emittance (low-e) coatings supported by a 0.32 mm diameter square pillar grid spaced at 25 mm. The third glass pane on which the 0.1 mm thick EC layer was deposited was sealed to the evacuated glass unit. The whole unit was rebated by 10 mm within a solid wood frame. The low-e coating absorbed 10% of solar energy incident on it. With the EC VG installed with the EC component facing the outdoor environment, for an incident solar radiation of 300 W m{sup -2}, simulations demonstrated that when the EC layer is opaque for winter conditions, the temperature of the inside glass pane is higher than the indoor air temperature, due to solar radiation absorbed by the low-e coatings and the EC layer, the EC VG is a heat source with heat transferred from the glazing to the interior environment. When the emittance was lower to 0.02, the outdoor and indoor glass pane temperatures of the glazing with single and two low-e coatings are very close to each other. For an insolation of 1000 W m{sup -2}, the outdoor glass pane temperature exceeds the indoor glass pane temperature, consequentially the outdoor glass pane transfers heat to the indoor glass pane. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cytotoxic, genotoxic and cell-cycle disruptive effects of thio-dimethylarsinate in cultured human cells and the role of glutathione

Thio-dimethylarsinate (thio-DMA), a recently discovered urine metabolite in humans, was investigated for its cytotoxic, genotoxic and cell-cycle disruptive effects in the cultured human hepatocarcinoma cell line, HepG2, and Syrian hamster embryo cells. In addition, the role of glutathione (GSH) on the cytotoxic effects of thio-DMA was investigated in terms of the effects of GSH depletion and the effects of exogenously added GSH. LC{sub 50} values of arsenicals for cells incubated for 48 h were 0.026 mM for thio-DMA, 0.343 mM for DMA and 3.66 mM for dithio-DMA. Depletion of cell GSH reduced the cytotoxic effects of thio-DMA. The cytotoxic effects of 0.02 mM and 0.05 mM thio-DMA were enhanced markedly when used in combination with 1 to 3 mM GSH, but decreased again when combined with 5 mM GSH. These results suggested that cytotoxic intermediates were generated by the interaction of thio-DMA with GSH, while an excessive amount of GSH suppressed the generation of these intermediates. Flow-cytometry showed that thio-DMA was an inducer of cells with 4N DNA and hypo 2N DNA. The results also demonstrated that cells arrested in the mitotic phase had abnormalities in their spindle organization and centrosome integrity. In addition, cells arrested in mitosis by thio-DMA had chromosome structural aberrations, such as chromatid gaps, chromatid breaks and chromatid exchanges. Moreover, the cytotoxic effects of thio-DMA may in part be associated with an apoptotic mode of cell death that was evaluated by the appearance of nucleosome level DNA fragmentations and an 85-kDa cleavage fragment of poly (ADP-ribose) polymerase. These findings suggest that the presence of thio-DMA in human urine has implications for human health in terms of arsenic metabolism and toxicity.

60 APPLIED LIFE SCIENCES↗

Kinetics of Fe(II)-catalyzed transformation of 6-line ferrihydrite under anaerobic flow conditions

The readsorption of ferrous ions produced by the abiotic and microbially-mediated reductive dissolution of iron oxy-hydroxides drives a series of transformations of the host minerals. To further understand the mechanisms by which these transformations occur and their kinetics within a microporous flow environment, flow-through experiments were conducted in which capillary tubes packed with ferrihydrite-coated glass spheres were injected with inorganic Fe(II) solutions under circumneutral pH conditions at 25 C. Synchrotron X-ray diffraction was used to identify the secondary phase(s) formed and to provide data for quantitative kinetic analysis. At concentrations at and above 1.8 mM Fe(II) in the injection solution, magnetite was the only secondary phase formed (no intermediates were detected), with complete transformation following a nonlinear rate law requiring 28 hours and 150 hours of reaction at 18 and 1.8 mM Fe(II), respectively. However, when the injection solution consisted of 0.36 mM Fe(II), goethite was the predominant reaction product and formed much more slowly according to a linear rate law, while only minor magnetite was formed. When the rates are normalized based on the time to react half of the ferrihydrite on a reduced time plot, it is apparent that the 1.8 mM and 18 mM input Fe(II) experiments can be described by the same reaction mechanism, while the 0.36 input Fe(II) experiment is distinct. The analysis of the transformation kinetics suggest that the transformations involved an electron transfer reaction between the aqueous as well as sorbed Fe(II) and ferrihydrite acting as a semiconductor, rather than a simple dissolution and recrystallization mechanism. A transformation mechanism involving sorbed inner sphere Fe(II) alone is not supported, since the essentially equal coverage of sorption sites in the 18 mM and 1.8 mM Fe(II) injections cannot explain the difference in the transformation rates observed.

54 ENVIRONMENTAL SCIENCES↗

Intra-Annual and Interannual Dynamics of Evaporation Over Western Lake Erie

Evaporation (E) is a critical component of the water and energy budget in lake systems yet is challenging to quantify directly and continuously. We examined the magnitude and changes of E and its drivers over Lake Erie - the shallowest and most southern lake of the Laurentian Great Lakes. We deployed two eddy-covariance tower sites in the western Lake Erie Basin - one located nearshore (CB) and one offshore (LI) - from September 2011 through May 2016. Monthly E varied from 5 to 120 mm, with maximum E occurring in August–October. The annual E was 635 ± 42 (±SD) mm at CB and 604 ± 32 mm at LI. Mean winter (October–March) E was 189 ± 61 mm at CB and 178 ± 25 mm at LI, accounting for 29.8% and 29.4% of annual E. Mean daily E was 1.8 mm during the coldest month (January) and 7.4 mm in the warmest month (July). Monthly E exhibited a strong positive linear relationship to the product of wind speed and vapor pressure deficit. Pronounced seasonal patterns in surface energy fluxes were observed with a 2-month lag in E from R n , due to the lake's heat storage. This lag was shorter than reports regarding other Great Lakes. Difference in E between the offshore and nearshore sites reflected within-lake spatial heterogeneity, likely attributable to climatic and bathymetric differences between them. These findings suggest that predictive models need to consider lake-specific heat storage and spatial heterogeneity in order to accurately simulate lake E and its seasonal dynamics.

54 ENVIRONMENTAL SCIENCES↗

Viral potential to modulate microbial methane metabolism varies by habitat

Methane is a potent greenhouse gas contributing to global warming. Microorganisms largely drive the biogeochemical cycling of methane, yet little is known about viral contributions to methane metabolism (MM). We analyzed 982 publicly available metagenomes from host-associated and environmental habitats containing microbial MM genes, expanding the known MM auxiliary metabolic genes (AMGs) from three to 24, including seven genes exclusive to MM pathways. These AMGs are recovered on 911 viral contigs predicted to infect 14 prokaryotic phyla including Halobacteriota, Methanobacteriota, and Thermoproteota. Of those 24, most were encoded by viruses from rumen (16/24), with substantially fewer by viruses from environmental habitats (0–7/24). To search for additional MM AMGs from an environmental habitat, we generate metagenomes from methane-rich sediments in Vrana Lake, Croatia. Therein, we find diverse viral communities, with most viruses predicted to infect methanogens and methanotrophs and some encoding 13 AMGs that can modulate host metabolisms. However, none of these AMGs directly participate in MM pathways. Together these findings suggest that the extent to which viruses use AMGs to modulate host metabolic processes (e.g., MM) varies depending on the ecological properties of the habitat in which they dwell and is not always predictable by habitat biogeochemical properties.

59 BASIC BIOLOGICAL SCIENCES↗

Roll Casting of Al-25%Si

Strip casting of Al-25%Si strip was tried using an unequal diameter twin roll caster. The diameter of the lower roll (large roll) was 1000 mm and the diameter of the upper roll (small roll) was 250 mm. Roll material was mild steel. The sound strip could be cast at the speeds ranging from 8 m/min to 12 m/min. The strip did not stick to the roll without the parting material. The primary Si, which existed at centre area of the thickness direction, was larger than that which existed at other area. The size of the primary Si was smaller than 0.2 mm. Eutectic Si was smaller 5 {mu}m. The as-cast strip was ranging from 2 mm to 3 mm thick and its width was 100 mm. The as-cast strip could be hot rolled down to 1 mm. The hot rolled strip was cold rolled. The primary Si became smaller and the pore occurred around the primary Si after the rolling.

36 MATERIALS SCIENCE↗

Phoswich scintillator for proton and gamma radiation of high energy

We present here a Phoswich scintillator design to achieve both high resolution gamma ray detection, and good efficiency for high energy protons. There are recent developments of new high resolution scintillator materials. Especially the LaBr3(Ce) and LaCl3(Ce) crystals have very good energy resolution in the order of 3% for 662 keV gamma radiation. In addition, these materials exhibit a very good light output (63 and 32 photons/keV respectively).A demonstrator detector in the form of an Al cylinder of 24 mm diameter and a total length of 80 mm with 2 mm wall thickness, containing a LaBr3(Ce) crystal of 20 mm diameter and 30 mm length directly coupled to a LaCl3(Ce) crystal of 50 mm length, and closed with a glass window of 5 mm, was delivered by Saint Gobain. To the glass window a Hamamatsu R5380 Photomultiplier tube (PMT) was coupled using silicon optical grease.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffusion studies on permeable nitroxyl spin probe through lipid bilayer membrane

Electron spin resonance (ESR) studies were carried out for 2mM {sup 14}N labeled deutrated permeable 3- methoxycarbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) in pure water, 1 mM, 2 mM, 3 mM and 4 mM concentration of MC-PROXYL in 300 mM concentration of liposomal solution by using a L-band ESR spectrometer. The ESR parameters such as linewidth, hyperfine coupling constant, g-factor, partition parameter and permeability were reported. The partition parameter and permeability values indicate the maximum spin distribution in the lipid phase at 2 mM concentration. This study illustrates that ESR can be used to differentiate between the intra and extra-membrane water by loading the liposome vesicles with a lipid-permeable nitroxyl spin probe. From the ESR results, the radical concentration was optimized as 2 mM in liposomal solution for ESR phantom studies and experiments.

36 MATERIALS SCIENCE↗

CW/Pulsed H{sup −} ion beam generation with PKU Cs-free 2.45 GHz microwave driven ion source

Circular accelerators used for positron emission tomography (PET, i.e. accelerator used for make radio isotopes) need several mA of CW H- ion beam for their routine operation. Other facilities, like Space Radio-Environment Simulate Assembly (SPRESA), require less than 10 mA pulsed mode H{sup −} beam. Caesium free negative hydrogen ion source is a good choice for those facilities because of its compact structure, easy operation and low cost. Up to now, there is no H{sup −} source able to produce very intense H{sup −} beams with important variation of the duty factor{sup [1]}. Recently, a new version of 2.45 GHz microwave H{sup −} ion source was designed at PKU, based on lessons learnt from the previous one. This non cesiated source is very compact thanks to its permanent magnet configuration. Special attention was paid on the design of the discharge chamber structure, electron dumping and extraction system. Source test to produce H{sup −} ion beams in pulsed and CW mode was carried out on PKU ion source test bench. In CW mode, a 10.8 mA/30keV H{sup −} beam with rms emittance about 0.16 π·mm·mrad has been obtained with only 500 W rf power. The power efficiency reaches 21 mA/kW. In pulsed mode with duty factor of 10% (100Hz/1ms), this compact source can easily deliver 20 mA H{sup −} ion beam at 35 keV with rms emittance about 0.2 π·mm·mrad when RF power is set at 2.2 kW (peak power). Several hour successive running operation in both modes and totaling more than 200 hours proves its high quality. The outside dimension of this new H{sup −} source body is ϕ116 mm × 124 mm, and the entire H{sup −} source infrastructure, including rf matching section, plasma chamber and extraction system, is ϕ310 × 180 mm. The high voltage region is limited with in a ϕ310 mm × 230 mm diagram. Details are given in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large-volume multianvil cells designed for chemical synthesis at high pressures

Two multianvil cell assemblies with octahedral edge lengths (OEL) of 18 and 25 mm have been developed, which allow sample volumes of up to 153 and 387 mm{sup 3}, respectively. Pressure calibrations were performed at room temperature and 1200 C using quenched samples, and at variable temperature using in situ synchrotron measurements. These calibrations employed 25.4 mm tungsten carbide anvils with a truncation edge length of 12 mm for the 18 mm OEL cell (18/12 configuration) and 15 mm for the 25 mm OEL cell (25/15 configuration) and yielded sample pressures of up to 10 and 7.5 GPa, respectively, at loads approaching 800 t. The measured thermal gradients at 1200 C vary between 5-10 C/mm (18/12) and 15-20 C/mm (25/15). By combining large sample/reaction volumes with minimal thermal gradients, the new multianvil cell assemblies are especially useful for chemical synthesis at high-pressure, high-temperature conditions.

47 OTHER INSTRUMENTATION↗

NATURE OF W51e2: MASSIVE CORES AT DIFFERENT PHASES OF STAR FORMATION

We present high-resolution continuum images of the W51e2 complex processed from archival data of the Submillimeter Array (SMA) at 0.85 and 1.3 mm and the Very Large Array at 7 and 13 mm. We also made line images and profiles of W51e2 for three hydrogen radio recombination lines (RRLs; H26alpha, H53alpha, and H66alpha) and absorption of two molecular lines of HCN(4-3) and CO(2-1). At least four distinct continuum components have been detected in the 3'' region of W51e2 from the SMA continuum images at 0.85 and 1.3 mm with resolutions of 0.''3 x 0.''2 and 1.''4 x 0.''7, respectively. The west component, W51e2-W, coincides with the ultracompact H II region reported from previous radio observations. The H26alpha line observation reveals an unresolved hyper-compact ionized core (<0.''06 or <310 AU) with a high electron temperature of 1.2 x 10{sup 4} K, with the corresponding emission measure EM>7 x 10{sup 10} pc cm{sup -6} and the electron density N{sub e} >7 x 10{sup 6} cm{sup -3}. The inferred Lyman continuum flux implies that the H II region W51e2-W requires a newly formed massive star, an O8 star or a cluster of B-type stars, to maintain the ionization. W51e2-E, the brightest component at 0.85 mm, is located 0.''9 east from the hyper-compact ionized core. It has a total mass of {approx}140 M{sub sun} according to our spectral energy distribution analysis and a large infall rate of >1.3 x 10{sup -3} M{sub sun} yr{sup -1} inferred from the absorption of HCN. W51e2-E appears to be the accretion center in W51e2. Given the fact that no free-free emission and no RRLs have been detected, the massive core of W51e2-E appears to host one or more growing massive proto-stars. Located 2'' northwest from W51e2-E, W51e2-NW is detected in the continuum emission at 0.85 and 1.3 mm. No continuum emission has been detected at lambda>= 7 mm. Along with the maser activities previously observed, our analysis suggests that W51e2-NW is at an earlier phase of star formation. W51e2-N is located 2'' north of W51e2-E and has only been detected at 1.3 mm with a lower angular resolution ({approx}1''), suggesting that it is a primordial, massive gas clump in the W51e2 complex.

74 ATOMIC AND MOLECULAR PHYSICS↗

GLOBAL SPECTRAL ENERGY DISTRIBUTION OF THE CRAB NEBULA IN THE PROSPECT OF THE PLANCK SATELLITE POLARIZATION CALIBRATION

Within the framework of the Planck satellite polarization calibration, we present a study of the Crab Nebula spectral energy distribution (SED) over more than six decades in frequency ranging from 1 to 10{sup 6} GHz (from 299 to 2.99 x 10{sup -4} mm). The Planck satellite mission observes the sky from 30 to 857 GHz (from 9.99 to 0.3498 mm) and therefore we focus on the millimeter region. We use radio and submillimeter data from the WMAP satellite between 23 and 94 GHz (from 13 to 3.18 mm), from the Archeops balloon experiment between 143 (2.1 mm) and 545 GHz (0.55 mm), and a compendium of other Crab Nebula observations. The Crab SED is compared to models including three main components: synchrotron that is responsible for the emission at low and high frequencies, dust that explains the excess of flux observed by the IRAS satellite, and an extra component on the millimeter regime. From this analysis, we conclude that the unpolarized emission of the Crab Nebula at microwave and millimeter wavelengths is the same synchrotron emission as the one observed in the radio domain. Therefore, we expect the millimeter emission of the Crab Nebula to be polarized with the same degree of polarization and orientation as the radio emission. We set upper limits on the possible errors induced by any millimeter extra component on the reconstruction of the degree and angle of polarization at the percent level as a maximum. This result strongly supports the choice by the Planck collaboration of the Crab Nebula emission for performing polarization cross-checks in the range 30 (299 mm) to 353 GHz (0.849 mm).

79 ASTRONOMY AND ASTROPHYSICS↗

RADIO IMAGING OF THE NGC 2024 FIR 5/6 REGION: A HYPERCOMPACT H II REGION CANDIDATE IN ORION

The NGC 2024 FIR 5/6 region was observed in the 6.9 mm continuum with an angular resolution of about 1.5 arcsec. The 6.9 mm continuum map shows four compact sources, FIR 5w, 5e, 6c, and 6n, as well as an extended structure of the ionization front associated with the optical nebulosity. FIR 6c has a source size of about 0.4 arcsec or 150 AU. The spectral energy distribution (SED) of FIR 6c is peculiar: rising steeply around 6.9 mm and flat around 1 mm. The possibility of a hypercompact H II region is explored. If the millimeter flux of FIR 6c comes from hot ionized gas heated by a single object at the center, the central object may be a B1 star of about 5800 solar luminosities and about 13 solar masses. The 6.9 mm continuum of FIR 6n may be a mixture of free-free emission and dust continuum emission. Archival data show that both FIR 6n and 6c exhibit water maser activity, suggesting the existence of shocked gas around them. The 6.9 mm continuum emission from FIR 5w has a size of about 1.8 arcsec or 760 AU. The SEDs suggest that the 6.9 mm emission of FIR 5w and 5e comes from dust, and the masses of the dense molecular gas are about 0.6 and 0.5 solar masses, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Extremely bright submillimeter galaxies beyond the Lupus-I star-forming region

We report detections of two candidate distant submillimeter galaxies (SMGs), MM J154506.4−344318 and MM J154132.7−350320, which are discovered in the AzTEC/ASTE 1.1 mm survey toward the Lupus-I star-forming region. The two objects have 1.1 mm flux densities of 43.9 and 27.1 mJy, and have Herschel/SPIRE counterparts as well. The Submillimeter Array counterpart to the former SMG is identified at 890 μm and 1.3 mm. Photometric redshift estimates using all available data from the mid-infrared to the radio suggest that the redshifts of the two SMGs are z{sub photo}≃4–5 and 3, respectively. Near-infrared objects are found very close to the SMGs and they are consistent with low-z ellipticals, suggesting that the high apparent luminosities can be attributed to gravitational magnification. The cumulative number counts at S{sub 1.1mm}⩾25 mJy, combined with the other two 1.1 mm brightest sources, are 0.70{sub −0.34}{sup +0.56} deg{sup −2}, which is consistent with a model prediction that accounts for flux magnification due to strong gravitational lensing. Unexpectedly, a z>3 SMG and a Galactic dense starless core (e.g., a first hydrostatic core) could be similar in the mid-infrared to millimeter spectral energy distributions and spatial structures at least at ≳1′′. This indicates that it is necessary to distinguish the two possibilities by means of broadband photometry from the optical to centimeter and spectroscopy to determine the redshift, when a compact object is identified toward Galactic star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗