Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Comparative analysis of methods for integrating various environmental impacts as a single index in life cycle assessment

Previous studies have proposed several methods for integrating characterized environmental impacts as a single index in life cycle assessment. Each of them, however, may lead to different results. This study presents internal and external normalization methods, weighting factors proposed by panel methods, and a monetary valuation based on an endpoint life cycle impact assessment method as the integration methods. Furthermore, this study investigates the differences among the integration methods and identifies the causes of the differences through a case study in which five elementary school buildings were used. As a result, when using internal normalization with weighting factors, the weighting factors had a significant influence on the total environmental impacts whereas the normalization had little influence on the total environmental impacts. When using external normalization with weighting factors, the normalization had more significant influence on the total environmental impacts than weighing factors. Due to such differences, the ranking of the five buildings varied depending on the integration methods. The ranking calculated by the monetary valuation method was significantly different from that calculated by the normalization and weighting process. The results aid decision makers in understanding the differences among these integration methods, and, finally, help them select the method most appropriate for the goal at hand.

54 ENVIRONMENTAL SCIENCES↗

Methods for land use impact assessment: A review

Many types of methods to assess land use impact have been developed. Nevertheless a systematic synthesis of all these approaches is necessary to highlight the most commonly used and most effective methods. Given the growing interest in this area of research, a review of the different methods of assessing land use impact (LUI) was performed using bibliometric analysis. One hundred eighty seven articles of agricultural and biological science, and environmental sciences were examined. According to our results, the most frequently used land use assessment methods are Life-Cycle Assessment, Material Flow Analysis/Input–Output Analysis, Environmental Impact Assessment and Ecological Footprint. Comparison of the methods allowed their specific features to be identified and to arrive at the conclusion that a combination of several methods is the best basis for a comprehensive analysis of land use impact assessment. - Highlights: • We identified the most frequently used methods in land use impact assessment. • A comparison of the methods based on several criteria was carried out. • Agricultural land use is by far the most common area of study within the methods. • Incentive driven methods, like LCA, arouse the most interest in this field.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of methods and improvement of predictions for specification properties of petroleum-based and alternative aviation fuels

To support our research and process modeling for liquid fuels, including blends, from petroleum and synthetic sources such as from biomass intermediates, we evaluated composition-based prediction methods and improved predictions for five key specification properties of petroleum-based and alternative aviation fuels, namely distillation temperatures (10 % distilled, t 10 , and final boiling point, t FBP ), density, flash point, net heat of combustion, and freezing point. The types of fuels included were petroleum-based jet fuels, jet-fuel surrogate mixtures, synthetic blending components obtained from different sources, and blends of Jet A with many synthetic blending components. Expanded datasets to update associated parameters allowed significant improvements for one of the prediction methods used in earlier work, namely the Modified Weighted Average method published initially by Shi et al. By considering the importance of lighter compounds for flash points and heavier compounds for freezing points, the revised Modified Weighted Average method was further improved. For liquid density, the revised Modified Weighted Average method gave the best overall results. The revised Modified Weighted Average method, the American Society for Testing and Materials D7215 method, and the D7215 method modified by another group gave comparable results for flash point, while the revised Modified Weighted Average and D3338 methods gave the best results for net heat of combustion. Freezing point was well predicted using the revised Modified Weighted Average method and showed the most significant improvements over current predictions. Distillation temperature t 10 was not well predicted, while t FBP was predicted with a mean absolute error comparable to experimental reproducibility.

09 BIOMASS FUELS↗

Dissipation-preserving spectral element method for damped seismic wave equations

This article describes the extension of the conformal symplectic method to solve the damped acoustic wave equation and the elastic wave equations in the framework of the spectral element method. The conformal symplectic method is a variation of conventional symplectic methods to treat non-conservative time evolution problems, which has superior behaviors in long-time stability and dissipation preservation. To reveal the intrinsic dissipative properties of the model equations, we first reformulate the original systems in their equivalent conformal multi-symplectic structures and derive the corresponding conformal symplectic conservation laws. We thereafter separate each system into a conservative Hamiltonian system and a purely dissipative ordinary differential equation system. Based on the splitting methodology, we solve the two subsystems respectively. The dissipative one is cheaply solved by its analytic solution. While for the conservative system, we combine a fourth-order symplectic Nyström method in time and the spectral element method in space to cover the circumstances in realistic geological structures involving complex free-surface topography. The Strang composition method is adopted thereby to concatenate the corresponding two parts of solutions and generate the completed conformal symplectic method. A relative larger Courant number than that of the traditional Newmark scheme is found in the numerical experiments in conjunction with a spatial sampling of approximately 5 points per wavelength. A benchmark test for the damped acoustic wave equation validates the effectiveness of our proposed method in precisely capturing dissipation rate. The classical Lamb problem is used to demonstrate the ability of modeling Rayleigh wave in elastic wave propagation. More comprehensive numerical experiments are presented to investigate the long-time simulation, low dispersion and energy conservation properties of the conformal symplectic methods in both the attenuating homogeneous and heterogeneous media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of Carbonyl Groups in Pyrolysis Bio-oils Using Potentiometric Titration: Review and Comparison of Methods

Carbonyl compounds present in bio-oils are known to be responsible for bio-oil property changes upon storage and during upgrading. As such, carbonyl content has previously been used as a method of tracking bio-oil aging and condensation reactions with less variability than viscosity measurements. Given the importance of carbonyls in bio-oils, accurate analytical methods for their quantification are very important for the bio-oil community. Potentiometric titration methods based on carbonyl oximation have long been used for the determination of carbonyl content in pyrolysis bio-oils. Here in this study, we present a modification of the traditional carbonyl oximation procedures that results in less reaction time, smaller sample size, higher precision, and more accurate carbonyl determinations. Some compounds such as carbohydrates are not measured by the traditional method (modified Nicolaides method), resulting in low estimations of the carbonyl content. Furthermore, we have shown that reaction completion for the traditional method can take up to 300 hours. The new method presented here (the modified Faix method) reduces the reaction time to 2 hours, uses triethanolamine (TEA) in the place of pyridine, and requires a smaller sample size for the analysis. Carbonyl contents determined using this new method are consistently higher than when using the traditional titration methods.

09 BIOMASS FUELS↗

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple attenuation to reflection seismic data using Radon filter and Wave Equation Multiple Rejection (WEMR) method

Separation between signal and noise, incoherent or coherent, is important in seismic data processing. Although we have processed the seismic data, the coherent noise is still mixing with the primary signal. Multiple reflections are a kind of coherent noise. In this research, we processed seismic data to attenuate multiple reflections in the both synthetic and real seismic data of Mentawai. There are several methods to attenuate multiple reflection, one of them is Radon filter method that discriminates between primary reflection and multiple reflection in the τ-p domain based on move out difference between primary reflection and multiple reflection. However, in case where the move out difference is too small, the Radon filter method is not enough to attenuate the multiple reflections. The Radon filter also produces the artifacts on the gathers data. Except the Radon filter method, we also use the Wave Equation Multiple Elimination (WEMR) method to attenuate the long period multiple reflection. The WEMR method can attenuate the long period multiple reflection based on wave equation inversion. Refer to the inversion of wave equation and the magnitude of the seismic wave amplitude that observed on the free surface, we get the water bottom reflectivity which is used to eliminate the multiple reflections. The WEMR method does not depend on the move out difference to attenuate the long period multiple reflection. Therefore, the WEMR method can be applied to the seismic data which has small move out difference as the Mentawai seismic data. The small move out difference on the Mentawai seismic data is caused by the restrictiveness of far offset, which is only 705 meter. We compared the real free multiple stacking data after processing with Radon filter and WEMR process. The conclusion is the WEMR method can more attenuate the long period multiple reflection than the Radon filter method on the real (Mentawai) seismic data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE APPLICATION OF CONTINUOUS WAVELET TRANSFORM BASED FOREGROUND SUBTRACTION METHOD IN 21 cm SKY SURVEYS

We propose a continuous wavelet transform based non-parametric foreground subtraction method for the detection of redshifted 21 cm signal from the epoch of reionization. This method works based on the assumption that the foreground spectra are smooth in frequency domain, while the 21 cm signal spectrum is full of saw-tooth-like structures, thus their characteristic scales are significantly different. We can distinguish them in the wavelet coefficient space easily and perform the foreground subtraction. Compared with the traditional spectral fitting based method, our method is more tolerant to complex foregrounds. Furthermore, we also find that when the instrument has uncorrected response error, our method can also work significantly better than the spectral fitting based method. Our method can obtain similar results with the Wp smoothing method, which is also a non-parametric method, but our method consumes much less computing time.

79 ASTRONOMY AND ASTROPHYSICS↗

Explicit Integration of Extremely Stiff Reaction Networks: Asymptotic Methods

We show that, even for extremely stiff systems, explicit integration may compete in both accuracy and speed with implicit methods if algebraic methods are used to stabilize the numerical integration. The stabilizing algebra differs for systems well removed from equilibrium and those near equilibrium. This paper introduces a quantitative distinction between these two regimes and addresses the former case in depth, presenting explicit asymptotic methods appropriate when the system is extremely stiff but only weakly equilibrated. A second paper [1] examines quasi-steady-state methods as an alternative to asymptotic methods in systems well away from equilibrium and a third paper [2] extends these methods to equilibrium conditions in extremely stiff systems using partial equilibrium methods. All three papers present systematic evidence for timesteps competitive with implicit methods. Because explicit methods can execute a timestep faster than an implicit method, our results imply that algebraically stabilized explicit algorithms may offer a means to integration of larger networks than have been feasible previously in various disciplines.

Guidry, Mike W↗

Identifying strengths and weaknesses of methods for computational network inference from single-cell RNA-seq data

Single-cell RNA-sequencing (scRNA-seq) offers unparalleled insight into the transcriptional programs of different cellular states by measuring the transcriptome of thousands of individual cells. An emerging problem in the analysis of scRNA-seq is the inference of transcriptional gene regulatory networks and a number of methods with different learning frameworks have been developed to address this problem. Here, we present an expanded benchmarking study of eleven recent network inference methods on seven published scRNA-seq datasets in human, mouse, and yeast considering different types of gold standard networks and evaluation metrics. We evaluate methods based on their computing requirements as well as on their ability to recover the network structure. We find that, while most methods have a modest recovery of experimentally derived interactions based on global metrics such as Area Under the Precision Recall curve, methods are able to capture targets of regulators that are relevant to the system under study. Among the top performing methods that use only expression were SCENIC, PIDC, MERLIN or Correlation. Addition of prior biological knowledge and the estimation of transcription factor activities resulted in the best overall performance with the Inferelator and MERLIN methods that use prior knowledge outperforming methods that use expression alone. We found that imputation for network inference did not improve network inference accuracy and could be detrimental. Comparisons of inferred networks for comparable bulk conditions showed that the networks inferred from scRNA-seq datasets are often better or at par with the networks inferred from bulk datasets. Our analysis should be beneficial in selecting methods for network inference. At the same time, this highlights the need for improved methods and better gold standards for regulatory network inference from scRNAseq datasets.

59 BASIC BIOLOGICAL SCIENCES↗

A comprehensive review of the lipid cubic phase or in meso method for crystallizing membrane and soluble proteins and complexes

A comprehensive and up-to-date review of the lipid cubic phase or in meso method for crystallizing membrane and soluble proteins and complexes is reported. Recent applications of the method for in situ serial crystallography at X-ray free-electron lasers and synchrotrons are described. The lipid cubic phase or in meso method is a robust approach for crystallizing membrane proteins for structure determination. The uptake of the method is such that it is experiencing what can only be described as explosive growth. This timely, comprehensive and up-to-date review introduces the reader to the practice of in meso crystallogenesis, to the associated challenges and to their solutions. A model of how crystallization comes about mechanistically is presented for a more rational approach to crystallization. The possible involvement of the lamellar and inverted hexagonal phases in crystallogenesis and the application of the method to water-soluble, monotopic and lipid-anchored proteins are addressed. How to set up trials manually and automatically with a robot is introduced with reference to open-access online videos that provide a practical guide to all aspects of the method. These range from protein reconstitution to crystal harvesting from the hosting mesophase, which is noted for its viscosity and stickiness. The sponge phase, as an alternative medium in which to perform crystallization, is described. The compatibility of the method with additive lipids, detergents, precipitant-screen components and materials carried along with the protein such as denaturants and reducing agents is considered. The powerful host and additive lipid-screening strategies are described along with how samples that have low protein concentration and cell-free expressed protein can be used. Assaying the protein reconstituted in the bilayer of the cubic phase for function is an important element of quality control and is detailed. Host lipid design for crystallization at low temperatures and for large proteins and complexes is outlined. Experimental phasing by heavy-atom derivatization, soaking or co-crystallization is routine and the approaches that have been implemented to date are described. An overview and a breakdown by family and function of the close to 200 published structures that have been obtained using in meso-grown crystals are given. Recommendations for conducting the screening process to give a more productive outcome are summarized. The fact that the in meso method also works with soluble proteins should not be overlooked. Recent applications of the method for in situ serial crystallography at X-ray free-electron lasers and synchrotrons are described. The review ends with a view to the future and to the bright prospects for the method, which continues to contribute to our understanding of the molecular mechanisms of some of nature’s most valued proteinaceous robots.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy

Purpose: Accurate measurement of the three-dimensional (3D) rigid body and surface kinematics of the natural human knee is essential for many clinical applications. Existing techniques are limited either in their accuracy or lack more realistic experimental evaluation of the measurement errors. The purposes of the study were to develop a volumetric model-based 2D to 3D registration method, called the weighted edge-matching score (WEMS) method, for measuring natural knee kinematics with single-plane fluoroscopy to determine experimentally the measurement errors and to compare its performance with that of pattern intensity (PI) and gradient difference (GD) methods. Methods: The WEMS method gives higher priority to matching of longer edges of the digitally reconstructed radiograph and fluoroscopic images. The measurement errors of the methods were evaluated based on a human cadaveric knee at 11 flexion positions. Results: The accuracy of the WEMS method was determined experimentally to be less than 0.77 mm for the in-plane translations, 3.06 mm for out-of-plane translation, and 1.13 deg. for all rotations, which is better than that of the PI and GD methods. Conclusions: A new volumetric model-based 2D to 3D registration method has been developed for measuring 3D in vivo kinematics of natural knee joints with single-plane fluoroscopy. With the equipment used in the current study, the accuracy of the WEMS method is considered acceptable for the measurement of the 3D kinematics of the natural knee in clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe

Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method. The BT filter thickness estimates resulting from the dual energy scans on the breast CT system were equivalent to the manufacturing specifications. The clinical CT evaluation produced data conceptually similar to previous computer simulations and plausible relative attenuation profiles were observed. Conclusions: The COBRA method is a fast and accurate method for BT filter characterization, which requires a simple experimental setup in a clinical environment. Because of the ease of data acquisition, multienergy scans can be acquired which allow characterization of the BT filter thickness.

60 APPLIED LIFE SCIENCES↗

Characterizing the marker-dye correction for Gafchromic EBT2 film: A comparison of three analysis methods

Purpose: Gafchromic EBT2 film has a yellow marker dye incorporated into the active layer of the film that can be used to correct the film response for small variations in thickness. This work characterizes the effect of the marker-dye correction on the uniformity and uncertainty of dose measurements with EBT2 film. The effect of variations in time postexposure on the uniformity of EBT2 is also investigated. Methods: EBT2 films were used to measure the flatness of a {sup 60}Co field to provide a high-spatial resolution evaluation of the film uniformity. As a reference, the flatness of the {sup 60}Co field was also measured with Kodak EDR2 films. The EBT2 films were digitized with a flatbed document scanner 24, 48, and 72 h postexposure, and the images were analyzed using three methods: (1) the manufacturer-recommended marker-dye correction, (2) an in-house marker-dye correction, and (3) a net optical density (OD) measurement in the red color channel. The field flatness was calculated from orthogonal profiles through the center of the field using each analysis method, and the results were compared with the EDR2 measurements. Uncertainty was propagated through a dose calculation for each analysis method. The change in the measured field flatness for increasing times postexposure was also determined. Results: Both marker-dye correction methods improved the field flatness measured with EBT2 film relative to the net OD method, with a maximum improvement of 1% using the manufacturer-recommended correction. However, the manufacturer-recommended correction also resulted in a dose uncertainty an order of magnitude greater than the other two methods. The in-house marker-dye correction lowered the dose uncertainty relative to the net OD method. The measured field flatness did not exhibit any unidirectional change with increasing time postexposure and showed a maximum change of 0.3%. Conclusions: The marker dye in EBT2 can be used to improve the response uniformity of the film. Depending on the film analysis method used, however, application of a marker-dye correction can improve or degrade the dose uncertainty relative to the net OD method. The uniformity of EBT2 was found to be independent of the time postexposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A characterization of robust radiation therapy treatment planning methods-from expected value to worst case optimization

Purpose: To characterize a class of optimization formulations used to handle systematic and random errors in radiation therapy, and to study the differences between the methods within this class. Methods: The class of robust methods that can be formulated as minimax stochastic programs is studied. This class generalizes many previously used methods, ranging between optimization of the expected and the worst case objective value. The robust methods are used to plan intensity-modulated proton therapy (IMPT) treatments for a case subject to systematic setup and range errors, random setup errors with and without uncertain probability distribution, and combinations thereof. As reference, plans resulting from a conventional method that uses a margin to account for errors are shown. Results: For all types of errors, target coverage robustness increased with the conservativeness of the method. For systematic errors, best case organ at risk (OAR) doses increased and worst case doses decreased with the conservativeness. Accounting for random errors of fixed probability distribution resulted in heterogeneous dose. The heterogeneities were reduced when uncertainty in the probability distribution was accounted for. Doing so, the OAR doses decreased with the conservativeness. All robust methods studied resulted in more robust target coverage and lower OAR doses than the conventional method. Conclusions: Accounting for uncertainties is essential to ensure plan quality in complex radiation therapy such as IMPT. The utilization of more information than conventional in the optimization can lead to robust target coverage and low OAR doses. Increased target coverage robustness can be achieved by more conservative methods.

60 APPLIED LIFE SCIENCES↗

A method for multichannel dosimetry with EBT3 radiochromic films

Purpose: An improved method for multichannel dosimetry is presented. This method explicitly takes into account the information provided by the unexposed image of the film. Methods: The method calculates the dose by applying a couple of perturbations to the scanned dose, one dependent and the other independent on the color channel. The method has been compared with previous multichannel and two single channel methods (red and green) against measurements using two different tests: first, five percentage depth dose profiles covering a wide range of doses; second, the dose map perpendicular to the beam axis for a 15 × 15cm{sup 2} square field. Finally, the results of 30 IMRT quality assurances tests are presented. All tests have been evaluated using the gamma analysis. Results: The coefficient of variation was found to be similar for all methods in a wide range of doses. The results of the proposed method are more in agreement with the experimental measurements and with the treatment planning system. Furthermore, the differences in the mean gamma pass rates are statistically significant. Conclusions: The improved multichannel dosimetric method is able to remove many of the common disturbances usually present in radiochromic films and improves the gamma analysis results compared with the other three methods.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-484: A New Method of Aligning Patient Setup Lasers in Radiation Therapy

Purpose: To develop a new method to align the patient setup lasers in radiation therapy and examine its validity and effectiveness. Methods: The new laser alignment method was realized by a device composed of both a metallic base plate and few acrylic transparent plates with a cross hair line on each of them. The holders of radiochromic films were prepared in the device to find a radiation isocenter. The right laser positions could be found optically by matching the shadows of all the cross hairs in the gantry head and the device. The repeatability and reproducibility (R and R) of laser alignments and the dependency of the alignment on the position error of the light source were evaluated by comparing the standard deviations and the means of the measured laser positions. After aligning the lasers optically, a radiation isocenter was found by a collimator spoke shot and the gantry spoke shot, and then the lasers were parallely translated to the isocenter. Results: In the R and R test, the standard deviation was 1.14 mm for the new method whereas it was 1.49 mm or 2.76 mm for the conventional method with either high- or low-precision levels. In the test of the dependency on the position error of the light source, the mean laser position was shifted by 5.3 mm corresponding to the shift of the light source, 4.8 mm for the new method, but for the conventional method the laser position was shifted more than 7 times than that. The positional shift could be corrected by a parallel translation to the isocenter in the new method. Conclusion: A new laser alignment method was devised for radiation therapy and tested successfully. The method enabled us to align the lasers easily and accurately without repetition, and all lasers could be finally aligned to the radiation isocenter.

60 APPLIED LIFE SCIENCES↗

A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform

Purpose: In digital x-ray radiography, an antiscatter grid is inserted between the patient and the image receptor to reduce scattered radiation. If the antiscatter grid is used in a stationary way, gridline artifacts will appear in the final image. In most of the gridline removal image processing methods, the useful information with spatial frequencies close to that of the gridline is usually lost or degraded. In this study, a new stationary gridline suppression method is designed to preserve more of the useful information. Methods: The method is as follows. The input image is first recursively decomposed into several smaller subimages using a multiscale 2D discrete wavelet transform. The decomposition process stops when the gridline signal is found to be greater than a threshold in one or several of these subimages using a gridline detection module. An automatic Gaussian band-stop filter is then applied to the detected subimages to remove the gridline signal. Finally, the restored image is achieved using the corresponding 2D inverse discrete wavelet transform. Results: The processed images show that the proposed method can remove the gridline signal efficiently while maintaining the image details. The spectra of a 1D Fourier transform of the processed images demonstrate that, compared with some existing gridline removal methods, the proposed method has better information preservation after the removal of the gridline artifacts. Additionally, the performance speed is relatively high. Conclusions: The experimental results demonstrate the efficiency of the proposed method. Compared with some existing gridline removal methods, the proposed method can preserve more information within an acceptable execution time.

60 APPLIED LIFE SCIENCES↗